Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Biomed Microdevices ; 25(3): 31, 2023 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-37584876

RESUMO

Local field potentials, the extracellular electrical activities from brain regions, provide clinically relevant information about the status of neurophysiological conditions, including epilepsy. In this study, a 13-channel silicon-based single-shank microelectrode array (MEA) was designed and fabricated to record local field potentials (LFPs) from the different depths of a rat's brain. A titanium/gold layer was patterned as electrodes on an oxidized silicon substrate, and silicon dioxide was deposited as a passivation layer. The fabricated array was implanted in the somatosensory cortex of the right hemisphere of an anesthetized rat. The developed MEA was interfaced with an OpenBCI Cyton Daisy Biosensing Board to acquire the local field potentials. The LFPs were acquired at three different neurophysiological conditions, including baseline signals, chemically-induced epileptiform discharges, and recovered baseline signals after anti-epileptic drug (AED) administration. Further, time-frequency analyses were performed on the acquired biopotentials to study the difference in spatiotemporal features. The processed signals and time-frequency analyses clearly distinguish between pre-convulsant and post-AED baselines and evoked epileptiform discharges.


Assuntos
Encéfalo , Roedores , Ratos , Animais , Microeletrodos , Encéfalo/fisiologia
2.
J Acoust Soc Am ; 154(6): 3833-3841, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38109407

RESUMO

Hermite-scan (H-scan) imaging is a tissue characterization technique based on the analysis of raw ultrasound radio frequency (RF) echoes. It matches the RF echoes to Gaussian-weighted Hermite polynomials of various orders to extract information related to scatterer diameter. It provides a color map of large and small scatterers in the red and blue H-scan image channels, respectively. H-scan has been previously reported for characterizing breast, pancreatic, and thyroid tumors. The present work evaluated H-scan imaging to differentiate glioblastoma tumors from normal brain tissue ex vivo. First, we conducted 2-D numerical simulations using the k-wave toolbox to assess the performance of parameters derived from H-scan images of acoustic scatterers (15-150 µm diameters) and concentrations (0.2%-1% w/v). We found that the parameter intensity-weighted percentage of red (IWPR) was sensitive to changes in scatterer diameters independent of concentration. Next, we assessed the feasibility of using the IWPR parameter for differentiating glioblastoma and normal brain tissues (n = 11 samples per group). The IWPR parameter estimates for normal tissue (44.1% ± 1.4%) were significantly different (p < 0.0001) from those for glioblastoma (36.2% ± 0.65%). These findings advance the development of H-scan imaging for potential use in differentiating glioblastoma tumors from normal brain tissue during resection surgery.


Assuntos
Glioblastoma , Humanos , Glioblastoma/diagnóstico por imagem , Ultrassonografia/métodos , Distribuição Normal , Algoritmos , Encéfalo/diagnóstico por imagem
3.
Biomed Microdevices ; 24(4): 31, 2022 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-36138255

RESUMO

Electrocorticography signals, the intracranial recording of electrical signatures of the brain, are recorded by non-penetrating planar electrode arrays placed on the cortical surface. Flexible electrode arrays minimize the tissue damage upon implantation. This work shows the design and development of a 32-channel flexible microelectrode array to record electrocorticography signals from the rat's brain. The array was fabricated on a biocompatible flexible polyimide substrate. A titanium/gold layer was patterned as electrodes, and a thin polyimide layer was used for insulation. The fabricated microelectrode array was mounted on the exposed somatosensory cortex of the right hemisphere of a rat after craniotomy and incision of the dura. The signals were recorded using OpenBCI Cyton Daisy Biosensing Boards. The array faithfully recorded the baseline electrocorticography signals, the induced epileptic activities after applying a convulsant, and the recovered baseline signals after applying an antiepileptic drug. The signals recorded by such fabricated microelectrode array from anesthetized rats demonstrate its potential to monitor electrical signatures corresponding to epilepsy. Finally, the time-frequency analyses highlight the difference in spatiotemporal features of baseline and evoked epileptic discharges.


Assuntos
Eletrocorticografia , Titânio , Animais , Anticonvulsivantes , Convulsivantes , Eletrodos Implantados , Ouro , Microeletrodos , Ratos , Roedores
4.
Biotechnol Bioeng ; 119(6): 1578-1597, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35244212

RESUMO

Directing cellular functionalities using biomaterial-based bioelectronic stimulation remains a significant constraint in translating research outcomes to address specific clinical needs. Electrical stimulation is now being clinically used as a therapeutic treatment option to promote bone tissue regeneration and to improve neuromuscular functionalities. However, the nature of the electrical waveforms during the stimulation and underlying biophysical rationale are still not scientifically well explored. Furthermore, bone-mimicking implant-based bioelectrical regulation of osteoinductivity has not been translated to clinics. The present study demonstrates the role of the electrical stimulation waveform to direct differentiation of stem cells on an electroactive polymeric substrate, using monophasic direct current (DC), square waveform, and biphasic waveform. In this regard, an in-house electrical stimulation device has been fabricated for the uninterrupted delivery of programmed electrical signals to stem cells in culture. To provide a functional platform for stem cells to differentiate, barium titanate (BaTiO3 , BT) reinforced poly(vinylidene difluoride) (PVDF) has been developed with mechanical properties similar to bone. The electrical stimulation of human mesenchymal stem cells (hMSCs) on PVDF/BT composite inhibited proliferation rate at day 7, indicating early commitment for differentiation. The phenotypical characteristics of DC stimulated hMSCs provided signatures of differentiation towards osteogenic lineage, which was subsequently confirmed using alkaline phosphatase assay, collagen deposition, matrix mineralization, and genetic expression. Our findings suggest that DC stimulation induced early osteogenesis in hMSCs with a higher level of intracellular reactive oxygen species (ROS), whereas the stimulation with square wave directed late osteogenesis with a lower ROS regeneration. In summary, the present study critically analyzes the role of electrical stimulation waveforms in regulating osteogenesis, without external biochemical differentiation inducers, on a bone-mimicking functional biomaterial substrate. Such a strategy can potentially be adopted to develop orthopedic implant-based bioelectronic medicine for bone regeneration.


Assuntos
Células-Tronco Mesenquimais , Osteogênese , Compostos de Bário , Materiais Biocompatíveis/química , Diferenciação Celular/fisiologia , Proliferação de Células , Células Cultivadas , Estimulação Elétrica , Polímeros de Fluorcarboneto , Humanos , Osteogênese/fisiologia , Polivinil , Espécies Reativas de Oxigênio/metabolismo , Titânio
5.
J Microelectromech Syst ; 26(1): 264-272, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28190945

RESUMO

Atrial fibrillation (AFib) is a significant healthcare problem caused by the uneven and rapid discharge of electrical signals from pulmonary veins (PVs). The technique of radiofrequency (RF) ablation can block these abnormal electrical signals by ablating myocardial sleeves inside PVs. Catheter contact force measurement during RF ablation can reduce the rate of AFib recurrence, since it helps to determine effective contact of the catheter with the tissue, thereby resulting in effective power delivery for ablation. This paper presents the development of a three-dimensional (3D) force sensor to provide the real-time measurement of tri-axial catheter contact force. The 3D force sensor consists of a plastic cubic bead and five flexible force sensors. Each flexible force sensor was made of a PEDOT:PSS strain gauge and a PDMS bump on a flexible PDMS substrate. Calibration results show that the fabricated sensor has a linear response in the force range required for RF ablation. To evaluate its working performance, the fabricated sensor was pressed against gelatin tissue by a micromanipulator and also integrated on a catheter tip to test it within deionized water flow. Both experiments simulated the ventricular environment and proved the validity of applying the 3D force sensor in RF ablation.

6.
J Micromech Microeng ; 25(7)2015 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-26526747

RESUMO

The use of flexible micro-electro-mechanical systems (MEMS) based device provides a unique opportunity in bio-medical robotics such as characterization of normal and malignant tissues. This paper reports on design and development of a flexible MEMS-based sensor array integrating mechanical and electrical sensors on the same platform to enable the study of the change in electro-mechanical properties of the benign and cancerous breast tissues. In this work, we present the analysis for the electrical characterization of the tissue specimens and also demonstrate the feasibility of using the sensor for mechanical characterization of the tissue specimens. Eight strain gauges acting as mechanical sensors were fabricated using poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) conducting polymer on poly(dimethylsiloxane) (PDMS) as the substrate material. Eight electrical sensors were fabricated using SU-8 pillars on gold (Au) pads which were patterned on the strain gauges separated by a thin insulator (SiO2 1.0µm). These pillars were coated with gold to make it conducting. The electromechanical sensors are integrated on the same substrate. The sensor array covers 180µm × 180µm area and the size of the complete device is 20mm in diameter. The diameter of each breast tissue core used in the present study was 1mm and the thickness was 8µm. The region of interest was 200µm × 200µm. Microindentation technique was used to characterize the mechanical properties of the breast tissues. The sensor is integrated with conducting SU-8 pillars to study the electrical property of the tissue. Through electro-mechanical characterization studies using this MEMS-based sensor, we were able to measure the accuracy of the fabricated device and ascertain the difference between benign and cancer breast tissue specimens.

7.
Microsc Microanal ; 21(5): 1224-35, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26343283

RESUMO

Atomic force microscopy (AFM) and other forms of scanning probe microscopy have been successfully used to assess biomechanical and bioelectrical characteristics of individual cells. When extending such approaches to heterogeneous tissue, there exists the added challenge of traversing the tissue while directing the probe to the exact location of the targeted biological components under study. Such maneuvers are extremely challenging owing to the relatively small field of view, limited availability of reliable visual cues, and lack of context. In this study we designed a system that leverages the visual topology of the serial tissue sections of interest to help guide robotic control of the AFM stage to provide the requisite navigational support. The process begins by mapping the whole-slide image of a stained specimen with a well-matched, consecutive section of unstained section of tissue in a piecewise fashion. The morphological characteristics and localization of any biomarkers in the stained section can be used to position the AFM probe in the unstained tissue at regions of interest where the AFM measurements are acquired. This general approach can be utilized in various forms of microscopy for navigation assistance in tissue specimens.


Assuntos
Neoplasias da Mama/patologia , Microscopia de Força Atômica/métodos , Robótica/métodos , Feminino , Humanos , Microtomia , Coloração e Rotulagem
8.
Sens Actuators B Chem ; 199: 259-268, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25013305

RESUMO

Micro-Electro-Mechanical-Systems (MEMS) are desirable for use within medical diagnostics because of their capacity to manipulate and analyze biological materials at the microscale. Biosensors can be incorporated into portable lab-on-a-chip devices to quickly and reliably perform diagnostics procedure on laboratory and clinical samples. In this paper, electrical impedance-based measurements were used to distinguish between benign and cancerous breast tissues using microchips in a real-time and label-free manner. Two different microchips having inter-digited electrodes (10 µm width with 10 µm spacing and 10 µm width with 30 µm spacing) were used for measuring the impedance of breast tissues. The system employs Agilent E4980A precision impedance analyzer. The impedance magnitude and phase were collected over a frequency range of 100 Hz to 2 MHz. The benign group and cancer group showed clearly distinguishable impedance properties. At 200 kHz, the difference in impedance of benign and cancerous breast tissue was significantly higher (3110 Ω) in the case of microchips having 10 µm spacing compared to microchip having 30 µm spacing (568 Ω).

9.
J Biophotonics ; : e202400114, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39032125

RESUMO

The assessment of the transformation zone is a critical step toward diagnosis of cervical cancer. This work involves the development of a portable, label-free transvaginal multispectral diffuse optical imaging (MDOI) imaging probe to estimate the transformation zone. The images were acquired from N = 5 (N = 1 normal, N = 2 premalignant, and N = 2 malignant) patients. Key parameters such as spectral contrast ratio (ρ) at 545 and 450 nm were higher in premalignant (0.29, 0.25 for 450 nm and 0.30, 0.17 for 545 nm) as compared to the normal patients (0.13 and 0.14 for 450 and 545 nm, respectively). The threshold for the spectral intensity ratio R610/R450 and R610/R545 can also be used as a marker to correlate with the new and original squamous columnar junction (SCJ), respectively. The pilot study highlights the use of new markers such as spectral contrast ratio (ρ) and spectral intensity ratio (R610/R450 and R610/R545) images.

10.
ACS Appl Mater Interfaces ; 16(19): 24321-24340, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38700914

RESUMO

In current clinical practices related to orthopedics, dental, and cardiovascular surgeries, a number of biomaterial coatings, such as hydroxyapatite (HAp), diamond-like carbon (DLC), have been used in combination with metallic substrates (stainless steel, Ti6Al4V alloy, etc.). Although SiBCN coatings are widely explored in material science for diverse applications, their potential remains largely unexplored for biomedical applications. With this motivation, the present work reports the development of SiBxCyNzOm coatings on a Ti6Al4V substrate, employing a reactive radiofrequency (RF) magnetron sputtering technique. Three different coating compositions (Si0.27B0.10C0.31N0.07O0.24, Si0.23B0.06C0.21N0.22O0.27, and Si0.20B0.05C0.19N0.20O0.35) were obtained using a Si2BC2N target and varying nitrogen flow rates. The hydrophilic properties of the as-synthesized coatings were rationalized in terms of an increase in the number of oxygen-containing functional groups (OH and NO) on the surface, as probed using XPS and FTIR analyses. Furthermore, the cellular monoculture of SVEC4-10 endothelial cells and L929 fibroblasts established good cytocompatibility. More importantly, the coculture system of SVEC4-10 and L929, in the absence of growth factors, demonstrated clear cellular phenotypical changes, with extensive sprouting leading to tube-like morphologies on the coating surfaces, when stimulated using a customized cell stimulator (StimuCell) with 1.15 V/cm direct current (DC) electric field strength for 1 h. In addition, the hemocompatibility assessment using human blood samples revealed clinically acceptable hemolysis, less erythrocyte adhesion, shorter plasma recalcification, and reduced risk for thrombosis on the SiBxCyNzOm coatings, when compared to uncoated Ti6Al4V. Taken together, the present study unambiguously establishes excellent cytocompatibility, hemocompatibility, and defines the preangiogenic properties of SiBxCyNzOm bioceramic coatings for potential biomedical applications.


Assuntos
Ligas , Materiais Revestidos Biocompatíveis , Teste de Materiais , Titânio , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Ligas/química , Ligas/farmacologia , Titânio/química , Titânio/farmacologia , Humanos , Animais , Camundongos , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/citologia , Linhagem Celular , Propriedades de Superfície , Fibroblastos/efeitos dos fármacos , Fibroblastos/citologia , Neovascularização Fisiológica/efeitos dos fármacos
11.
J Breath Res ; 17(2)2023 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-36634360

RESUMO

Early disease detection is often correlated with a reduction in mortality rate and improved prognosis. Currently, techniques like biopsy and imaging that are used to screen chronic diseases are invasive, costly or inaccessible to a large population. Thus, a non-invasive disease screening technology is the need of the hour. Existing non-invasive methods like gas chromatography-mass spectrometry, selected-ion flow-tube mass spectrometry, and proton transfer reaction-mass-spectrometry are expensive. These techniques necessitate experienced operators, making them unsuitable for a large population. Various non-invasive sources are available for disease detection, of which exhaled breath is preferred as it contains different volatile organic compounds (VOCs) that reflect the biochemical reactions in the human body. Disease screening by exhaled breath VOC analysis can revolutionize the healthcare industry. This review focuses on exhaled breath VOC biomarkers for screening various diseases with a particular emphasis on liver diseases and head and neck cancer as examples of diseases related to metabolic disorders and diseases unrelated to metabolic disorders, respectively. Single sensor and sensor array-based (Electronic Nose) approaches for exhaled breath VOC detection are briefly described, along with the machine learning techniques used for pattern recognition.


Assuntos
Testes Respiratórios , Compostos Orgânicos Voláteis , Humanos , Testes Respiratórios/métodos , Compostos Orgânicos Voláteis/análise , Biomarcadores/análise , Expiração , Aprendizado de Máquina
12.
J Biomed Mater Res A ; 111(3): 340-353, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36403282

RESUMO

The present study reports the impact of the interplay between electroactive properties of the biomaterials and electrical stimulation (ES) toward the cell proliferation, migration and maturation of osteoprogenitors (preosteoblasts; MC3T3-E1) on the electroactive poly (vinylidene difluoride) (PVDF)-based composites. The barium titanate (BaTiO3; BT; 30 wt%) and multiwalled carbon nanotubes (MWCNT; 3 wt%) were introduced into the PVDF via melt mixing, which led to an enhancement of the dielectric permittivity, electrical conductivity, and surface roughness. We also present the design and development of an in-house customized 12-well plate-based device for providing different types (DC, square, biphasic) of ES to cells in culture in a programmable manner. In the presence of ES of 1 V cm-1 , biophysical stimulation experiments performed using 12-well plate-based device revealed that PVDF composite (PVDF/30BT/3MWCNT) can facilitate the enhanced adhesion and proliferation of the MC3T3-E1 in non-osteogenic media, with respect to non-stimulated conditions. Importantly, MC3T3-E1 cells demonstrated significantly better migration and differentiation on the PVDF/30BT/3MWCNT under ES when compared to ES-free culture conditions. Similar enhancement with respect to alkaline phosphatase activity, intracellular Ca2+ concentration, and calcium deposition in MC3T3-E1 cells was recorded, when pre-osteoblasts were grown for 21 days on electroactive substrates. All these observations supported the activation of osteo-differentiation fates, which were further promoted in the osteogenic medium. The present study demonstrates that the synergistic interactions of ES with piezoelectric PVDF-based polymer composite can potentially enhance the proliferation, migration, and osteogenesis of the pre-osteoblast cells, rendering it a promising bioengineering strategy for bone tissue engineering.


Assuntos
Materiais Biocompatíveis , Nanotubos de Carbono , Materiais Biocompatíveis/metabolismo , Osteoblastos , Diferenciação Celular , Osteogênese
13.
IEEE Rev Biomed Eng ; 16: 687-705, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35687618

RESUMO

Breast cancer is a leading cause of mortality among women. The patient's survival rate is uncertain due to the limitations in the accuracy of diagnosis and effective monitoring during cancer treatment. The key to efficaciously controlling cancer on a larger scale is effective diagnosis at an early stage of cancer by distinguishing the vital signatures of the diseased from the normal breast tissue. The breast tissue is a heterogeneous turbid media that exhibits multifaceted bulk tissue properties. Various sensing modalities can yield distinct tissue behavior for cancer and adjacent normal tissues, serving as a basis for cancer diagnosis. A novel multimodal diagnostic tool that can concurrently assess the optical, electrical, and mechanical bulk tissue properties can substantially augment the clinical findings such as histopathology, potentially aiding the clinician to establish an accurate and rapid diagnosis of cancer. This review aims to discuss the clinical and engineering aspects along with the unmet challenges of these physical sensing modalities, primarily in the field of optical, electrical, and mechanical. The challenges of combining two or more of these sensing modalities that can significantly enhance the effectiveness of the clinical diagnostic tools are further investigated.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico , Tecnologia Biomédica
14.
J Biol Eng ; 17(1): 68, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37957665

RESUMO

BACKGROUND: Technologies for quick and label-free diagnosis of malignancies from breast tissues have the potential to be a significant adjunct to routine diagnostics. The biophysical phenotypes of breast tissues, such as its electrical, thermal, and mechanical properties (ETM), have the potential to serve as novel markers to differentiate between normal, benign, and malignant tissue. RESULTS: We report a system-of-biochips (SoB) integrated into a semi-automated mechatronic system that can characterize breast biopsy tissues using electro-thermo-mechanical sensing. The SoB, fabricated on silicon using microfabrication techniques, can measure the electrical impedance (Z), thermal conductivity (K), mechanical stiffness (k), and viscoelastic stress relaxation (%R) of the samples. The key sensing elements of the biochips include interdigitated electrodes, resistance temperature detectors, microheaters, and a micromachined diaphragm with piezoresistive bridges. Multi-modal ETM measurements performed on formalin-fixed tumour and adjacent normal breast biopsy samples from N = 14 subjects were able to differentiate between invasive ductal carcinoma (malignant), fibroadenoma (benign), and adjacent normal (healthy) tissues with a root mean square error of 0.2419 using a Gaussian process classifier. Carcinoma tissues were observed to have the highest mean impedance (110018.8 ± 20293.8 Ω) and stiffness (0.076 ± 0.009 kNm-1) and the lowest thermal conductivity (0.189 ± 0.019 Wm-1 K-1) amongst the three groups, while the fibroadenoma samples had the highest percentage relaxation in normalized load (47.8 ± 5.12%). CONCLUSIONS: The work presents a novel strategy to characterize the multi-modal biophysical phenotype of breast biopsy tissues to aid in cancer diagnosis from small-sized tumour samples. The methodology envisions to supplement the existing technology gap in the analysis of breast tissue samples in the pathology laboratories to aid the diagnostic workflow.

15.
Artigo em Inglês | MEDLINE | ID: mdl-38082710

RESUMO

Objective measurement of the lumen area demands an intraoperative diagnostic tool to aid on-site decision-making. We present a compliant mechanism-based unfurling actuator assembly integrated with a shaft connected to a motorized encoder to translate torque from the user at the proximal end to the actuator at the distal end. The actuator assembly has flexible arms coiled inside a cylindrical casing that moves radially outward upon actuation. Leveraging 3D printing of flexible materials, the unfurling actuator's four-arm design enables patency measurements in circumferential tracheal stenosis of varying grades. The rotary encoder output is correlated with the radially outward movement of the unfurling arms to estimate the lumen diameter. The measurement stability is analyzed using process control charts; data distribution over ten iterations reveals nearly 100% of process data falls between ±3 sigma (Upper and Lower control limits). Comparing measurements from the tool with direct measurement (vernier caliper) and ImageJ analysis, one-way ANOVA for circular morphology yields no significant differences in diameter p = 0.974 and area measurements p = 0.975.Clinical Relevance- Central airway narrowing reduces the effective lumen area in the tracheal and bronchial segments. Grading the degree of narrowing is often based on a suspicion index. A quick but thorough assessment of the airway caliber is essential in emergent or planned intubation, whether congenital, iatrogenic, or idiopathic tracheal stenosis.


Assuntos
Estenose Traqueal , Humanos , Torque , Intubação
16.
J Neurosci Methods ; 392: 109864, 2023 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-37080434

RESUMO

One of the characteristic features of adolescence is risk-taking behavioural traits. Uncontrolled risk-taking without proper assessment may have harmful impact on mental health later in life. Therefore, it is essential to identify it early for the preventable health problems. In the present study, we have designed a novel paradigm, viz. Risky Decision-taking Task (RDTT), to evaluate the spontaneous risk-taking behavioural repertoire in adolescent rodents. The task was designed based on both risk and cognitive factors. To validate and compare the risk-taking tendency, we have used early maternal separation and isolation (MS) stress model, as it is known to increase anxiety and curiosity-like behaviour at adolescence. We have used Sprague-Dawley rats of both sexes. Rats were exposed to MS stress for 10 days daily for six hours during stress hyporesponsive period (SHRP) from postnatal day 4-13. These rats were subjected to RDTT during adolescence. This task is a reward-based task where the latency to collect reward in the presence or absence of a risk factor is assessed. It consists of habituation, training to find the location of small and large rewards, reward preference for small and large reward and testing period under risky situation. Rats were trained individually to retrieve the valuation-based rewards under the risky, but innate aversive environments. The results from RDTT showed that as compared to controls, MS rats from both sexes showed reduced latency to collect large reward in the presence of a risk element and a reduced risk-index which is indicative of a higher risk-taking tendency in these rats. In addition, MS rats showed a trend towards anxiety-like behaviour as compared to controls in the Light-Dark Test. These results together show decreased risk latency for the large reward and reduced risk assessment in MS rats which is suggestive of more risk-taking tendency in these rats. Thus, we propose that RDTT paradigm can be used to evaluate the spontaneous risk-taking behavioural repertoire based on innate, spontaneous aversion and cognitive factors in rats.


Assuntos
Tomada de Decisões , Estresse Psicológico , Animais , Feminino , Masculino , Ratos , Privação Materna , Ratos Sprague-Dawley , Recompensa , Assunção de Riscos
17.
PLoS One ; 18(9): e0291972, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37747904

RESUMO

The high prevalence of oral potentially-malignant disorders exhibits diverse severity and risk of malignant transformation, which mandates a Point-of-Care diagnostic tool. Low patient compliance for biopsies underscores the need for minimally-invasive diagnosis. Oral cytology, an apt method, is not clinically applicable due to a lack of definitive diagnostic criteria and subjective interpretation. The primary objective of this study was to identify and evaluate the efficacy of biomarkers for cytology-based delineation of high-risk oral lesions. A comprehensive systematic review and meta-analysis of biomarkers recognized a panel of markers (n: 10) delineating dysplastic oral lesions. In this observational cross sectional study, immunohistochemical validation (n: 131) identified a four-marker panel, CD44, Cyclin D1, SNA-1, and MAA, with the best sensitivity (>75%; AUC>0.75) in delineating benign, hyperplasia, and mild-dysplasia (Low Risk Lesions; LRL) from moderate-severe dysplasia (High Grade Dysplasia: HGD) along with cancer. Independent validation by cytology (n: 133) showed that expression of SNA-1 and CD44 significantly delineate HGD and cancer with high sensitivity (>83%). Multiplex validation in another cohort (n: 138), integrated with a machine learning model incorporating clinical parameters, further improved the sensitivity and specificity (>88%). Additionally, image automation with SNA-1 profiled data set also provided a high sensitivity (sensitivity: 86%). In the present study, cytology with a two-marker panel, detecting aberrant glycosylation and a glycoprotein, provided efficient risk stratification of oral lesions. Our study indicated that use of a two-biomarker panel (CD44/SNA-1) integrated with clinical parameters or SNA-1 with automated image analysis (Sensitivity >85%) or multiplexed two-marker panel analysis (Sensitivity: >90%) provided efficient risk stratification of oral lesions, indicating the significance of biomarker-integrated cytopathology in the development of a Point-of-care assay.


Assuntos
Bioensaio , Receptores de Hialuronatos , Humanos , Hiperplasia/diagnóstico , Automação , Biópsia , Glicosilação , Estudos Observacionais como Assunto
18.
ACS Omega ; 7(38): 34177-34189, 2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36188250

RESUMO

Metallic nanostructures are considered attractive candidates for designing novel biosensors due to their enormously significant surface area, accelerated kinetics, and improved affinity. Controllable morphological tuning of metallic nanostructures on sensing interfaces is crucial for attaining clinically relevant sensitivity and exquisite selectivity in a complex biological environment. Therefore, a facile, convenient, and robust one-step electroreduction method was employed to develop different morphological variants of palladium (Pd) nanostructures supported onto oxidized carbon nanotubes to facilitate label-free electrochemical immunosensing of HER2. The morphological and structural attributes of the synthesized Pd nanostructures were thoroughly investigated using scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and atomic force microscopy techniques. In-depth electrochemical investigations revealed an intimate correlation between the nanostructured sensor and electrochemical response, suggesting the suitability of hierarchical palladium nanostructures supported onto carbon nanotubes [Pd(-0.1 V)/CNT] for sensitive detection of HER2. The high surface area of hierarchical Pd nanostructures enabled an ultrasensitive electrochemical response toward HER2 (detection limit: 1 ng/mL) with a wide detection range of 10 to 100 ng/mL. The ease of surface modification, sensitivity, and reliable electrochemical response in human plasma samples suggested the enormous potential of Pd nanostructuring for chip-level point-of-care screening of HER2-positive breast cancer patients.

19.
J Biophotonics ; 15(3): e202100282, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34846777

RESUMO

A robust, affordable and portable light emitting diode-based diagnostic tools (POLS-NIRDx) using a polarization-sensitive (linear as well as circular polarization) technique were designed and developed to quantify the degree of linear polarization (DOLP), degree of circular polarization (DOCP). The study was performed on malignant (invasive ductal carcinoma) and adjacent normal ex-vivo biopsy tissues excised from N = 10 patients at the operating wavelengths of 850 and 940 nm. The average DOLP and DOCP values were lower for malignant than adjacent normal while operating at 850 and 940 nm. The highest accuracy was observed for DOLP (100%) and DOCP (80%) while operating at 850 nm, which reduced (80% for DOLP and 65% for DOCP) at 940 nm. This pilot study can be utilized as a differentiating factor to delineate malignant tissues from adjacent normal tissues.


Assuntos
Neoplasias da Mama , Biópsia , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Projetos Piloto , Análise Espectral
20.
Microsyst Nanoeng ; 8: 1, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35087680

RESUMO

The rapid and label-free diagnosis of malignancies in ex vivo breast biopsy tissues has significant utility in pathology laboratories and operating rooms. We report a MEMS-based platform integrated with microchips that performs phenotyping of breast biopsy tissues using electrothermal sensing. The microchip, fabricated on a silicon substrate, incorporates a platinum microheater, interdigitated electrodes (IDEs), and resistance temperature detectors (RTDs) as on-chip sensing elements. The microchips are integrated onto the platform using a slide-fit contact enabling quick replacement for biological measurements. The bulk resistivity (ρ B ), surface resistivity (ρ S ), and thermal conductivity (k) of deparaffinized and formalin-fixed paired tumor and adjacent normal breast biopsy samples from N = 8 patients were measured. For formalin-fixed samples, the mean ρ B for tumors showed a statistically significant fold change of 4.42 (P = 0.014) when the tissue was heated from 25 °C to 37 °C compared to the adjacent normal tissue, which showed a fold change of 3.47. The mean ρ S measurements also showed a similar trend. The mean k of the formalin-fixed tumor tissues was 0.309 ± 0.02 W m-1 K-1 compared to a significantly higher k of 0.563 ± 0.028 W m-1 K-1 for the adjacent normal tissues. A similar trend was observed in ρ B, ρ S, and k for the deparaffinized tissue samples. An analysis of a combination of ρ B , ρ S , and k using Fisher's combined probability test and linear regression suggests the advantage of using all three parameters simultaneously for distinguishing tumors from adjacent normal tissues with higher statistical significance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA