Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Biochim Biophys Acta ; 453(1): 192-9, 1976 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-11823

RESUMO

The use of an iridium microelectrode 0.5 mm in diameter is proposed for measuring the pH gradient in polyacrylamide gels after isoelectric focusing. The electrode exhibits a perfectly linear potential/pH relationship; thus it can be used directly in conjunction with a pH meter using the pH scale for readings. pH equilibrium values are rapidly reached (10-15 s) and pI determinations are obtainable with good accuracy (better than 0.1 pH).


Assuntos
Proteínas , Calorimetria , Estudos de Avaliação como Assunto , Géis , Concentração de Íons de Hidrogênio , Irídio , Focalização Isoelétrica/métodos , Microeletrodos , Proteínas/isolamento & purificação , Temperatura , Termodinâmica
2.
J Pharm Biomed Anal ; 1(1): 47-53, 1983.
Artigo em Inglês | MEDLINE | ID: mdl-16867833

RESUMO

A rugged, low resistance silver-silver sulphide solid-state electrode for determining pharmaceuticals as authentic samples or in dosage forms by potentiometric titration is described. Sodium tetraphenylborate, mercury(II) acetate and silver nitrate (0.01) M were employed as titrants in the analysis of cationic surfactants (cetylpyridinium chloride, benzethonium chloride, benzalkonium chloride and chlorhexidine salts), antithyroid drugs (methimazole and propylthiouracil) or sodium halides respectively.

3.
Farmaco ; 45(6 Suppl): 707-14, 1990 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2400521

RESUMO

A precise and accurate differential pulse polarographic method was developed for the determination of flubendazole in dosage forms without any prior extraction procedure of interference from the other stated ingredients. A UV spectroscopic procedure was also described and used as reference method. Analyses were generally performed at the 4 micrograms ml-1 flubendazole level. Flubendazole or its dosage forms were dissolved in 70% perchloric acid and diluted with a pH 2.6 sodium phosphate-citric acid buffer as polarographic supporting electrolyte or spectrophotometric solvent. The peak potential occurred at about -0.9 V (vs. Ag/AgCl reference electrode), depending on the pH of the assayed solution. The irreversible electrochemical reduction involved the transfer of two electrons. The UV absorption spectrum showed a sharp maximum at 237 nm with a specific extinction coefficient of 886. No advantage was found in the use of first and second-order derivative spectrophotometry.


Assuntos
Mebendazol/análogos & derivados , Indicadores e Reagentes , Mebendazol/análise , Polarografia , Pós , Espectrofotometria Ultravioleta , Suspensões , Comprimidos
4.
J Med Eng Technol ; 5(2): 86-8, 1981 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7277452

RESUMO

An iridium-iridium oxide electrode for in vivo monitoring of blood pH changes is described. Because of its small size, sensitivity, flexibility, strength and fast response, this electrode is suitable for acute implantation even in the small vessels of animals such as rats or guinea pigs, allowing continuous pH monitoring anywhere in the central arteries or veins. Excellent noise-free records have been obtained in the in vivo experiments in animals.


Assuntos
Sangue , Irídio , Microeletrodos , Monitorização Fisiológica/instrumentação , Animais , Feminino , Cobaias , Concentração de Íons de Hidrogênio , Masculino
5.
J Med Eng Technol ; 8(5): 221-3, 1984.
Artigo em Inglês | MEDLINE | ID: mdl-6527372

RESUMO

An iridium-iridium oxide electrode for in vivo pH measurement of the distal oesophagus is described. It is small and flexible so it is well accepted by patients for long-term pH monitoring. The electrode also offers the possibility of including another electrode and/or a pressure sensor for simultaneous detection of two or more parameters--gastric pH or oesophageal pressure for example. A clinical study was performed on 15 healthy volunteers and the results were checked on a DGC Nova 4/S computer, showing less than 0.005% of tension in mV out of the established range in a period of 24 h pH monitoring. The volunteers' results were compared with the normal values obtained by DeMeester using a glass electrode on a similar, healthy group of American patients and no significant differences were observed. Owing to its small size, reliability, fast response to pH changes, durability and its easy storage, the Ir/IrO2 electrode is ideal for long-term pH monitoring of the upper gastro-intestinal tract.


Assuntos
Eletrodos , Esôfago/análise , Determinação da Acidez Gástrica/instrumentação , Refluxo Gastroesofágico/diagnóstico , Adolescente , Adulto , Feminino , Humanos , Concentração de Íons de Hidrogênio , Irídio , Masculino
7.
J Pharm Biomed Anal ; 1(2): 223-8, 1983.
Artigo em Inglês | MEDLINE | ID: mdl-16867822
9.
Planta ; 211(3): 384-9, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10987557

RESUMO

A simple procedure is described for the fabrication of micrometer to nanometer-scale platinum electrodes to be used in a vibrating oxygen-selective system. The electrode was prepared by etching a fine platinum wire and insulating it with an electrophoretic paint. The dimensions allowed this electrode to be used with the "vibrating probe technique" in exploratory studies aimed at mapping and measuring the patterns of net influxes as well as effluxes of oxygen in Olea europaea L. leaves and roots with spatial and temporal resolutions of a few microns and a few seconds, respectively. The magnitude and spatial localisation of O2 influxes in roots was characterised by two distinct peaks. The first, in the division zone, averaged 38 +/- 5 nmol m(-2) s(-1); the second, in the elongation region, averaged 68 +/- 6 nmol m(-2) s(-1). Long-term records of oxygen influx in the elongation region of the root showed an oscillatory regime characterised by a fast oscillation with periods of about 8-9 min. In leaves, the system allowed the measurement of real-time changes in O2 evolution following changes in light. Furthermore, it was possible to obtain "topographical" images of the photosynthetically generated oxygen diffusing through different stomata from a region of the leaf of 120 microm x 120 microm. The combination of topographic and electrochemical information at the micrometer scale makes the system an efficient tool for studying biological phenomena involving oxygen diffusion.


Assuntos
Oxigênio/metabolismo , Plantas Comestíveis/fisiologia , Cinética , Luz , Potenciais da Membrana , Microeletrodos , Folhas de Planta/metabolismo , Brotos de Planta/metabolismo , Polarografia/métodos , Fatores de Tempo , Árvores/fisiologia
10.
Poumon Coeur ; 33(4): 259-63, 1977.
Artigo em Francês | MEDLINE | ID: mdl-335378

RESUMO

Parts of rat lung tissue have been examined by means of a scanning electron microscope after either chemical or physical fixage. Chemical fixage produces retraction on the tissue structures and the alveoles appear of irregular shape. Physical fixage gives the possibility to observe lung morphology without distorsions; details reproduced are in this case very clear and in a shape which appears very close to the original conditions.


Assuntos
Pulmão/anatomia & histologia , Microscopia Eletrônica de Varredura , Animais , Técnicas Histológicas , Ratos
11.
Pacing Clin Electrophysiol ; 1(4): 448-57, 1978 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-95637

RESUMO

A cardiac pacemaker capable of responding to blood acidosis by change in its stimulation rate allows adjustment to a patient's metabolic needs. The blood pH is sensed by an iridium oxide electrode in the right atrium. During exercise, the venous pH decreases and the paced ventricular rate increases. If acidosis persists, the paced rate gradually returns to baseline and reaches it after about 70 minutes. A pH-triggered pacemaker has been implanted in a 72-year-old male. The pacemaker remained responsive one year after implant, increasing rate during exercise, cold pressor stress, ischemia of the arms and emotional stress.


Assuntos
Análise Química do Sangue/instrumentação , Marca-Passo Artificial , Idoso , Animais , Braço/irrigação sanguínea , Temperatura Baixa , Eletrodos Implantados , Estudos de Avaliação como Assunto , Teste de Esforço , Humanos , Concentração de Íons de Hidrogênio , Irídio , Isquemia/fisiopatologia , Masculino , Monitorização Fisiológica , Ratos , Estresse Psicológico/fisiopatologia , Veias
12.
Pharm Acta Helv ; 64(4): 125-8, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2726993

RESUMO

A differential pulse polarographic method requiring little sample separation was developed for the determination of isosorbide-5-mononitrate in tablet dosage form with the standard addition technique and without interference from common excipients. Britton-Welford buffer (pH 3.0) was used as the supporting electrolyte, the single peak occurring at -0.36 V vs. a reference Ag/AgCl electrode. The irreversible, diffusion controlled, two-electron reduction process at the dropping mercury electrode permits a precise and accurate determination of the active ingredient in the 0.4-20 microgram/ml concentration range.


Assuntos
Dinitrato de Isossorbida/análogos & derivados , Indicadores e Reagentes , Dinitrato de Isossorbida/análise , Polarografia , Comprimidos
13.
Poumon Coeur ; 32(3): 131-5, 1976.
Artigo em Francês | MEDLINE | ID: mdl-951351

RESUMO

The effect of citidin-diphosphocholine and of phospholipids treatments on the elastic properties as well as on the washing liquid physical-chemical properties of rat lungs is studied. Significant increase of the compliance and decrease of the tendency to collapse of the airways are observed after treatment with citidin-diphosphocholine.


Assuntos
Colina/análogos & derivados , Citidina Difosfato Colina/farmacologia , Complacência Pulmonar/efeitos dos fármacos , Fosfolipídeos/farmacologia , Animais , Pulmão/efeitos dos fármacos , Masculino , Ratos , Irrigação Terapêutica/métodos
14.
G Ital Cardiol ; 8 Suppl 1: 252-8, 1978.
Artigo em Italiano | MEDLINE | ID: mdl-39016

RESUMO

The Authors have selected the variations of blood pH to drive the pacing rate according to the new biological balance created by exercise. The clinical tests performed on the patients who have had a pH-triggered pacemaker implanted one year previously demonstrated that: a) during physical exercise there is an increase of cardiac rate triggered by the pacemaker, comparable with that noted when sinus rhythm is present; b) situations causing an increased production of cathecolamines and thus a pH variation--Cold Pressor Test, Ischaemic Test, as well as emotional stress--cause an increase of the stimulation rate of pH triggered pacemaker.


Assuntos
Sangue/metabolismo , Estimulação Cardíaca Artificial/métodos , Concentração de Íons de Hidrogênio , Catecolaminas/fisiologia , Temperatura Baixa , Teste de Esforço , Humanos , Marca-Passo Artificial , Fluxo Sanguíneo Regional , Estresse Psicológico/fisiopatologia , Sistema Vasomotor/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA