Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 203
Filtrar
1.
Opt Lett ; 49(3): 522-525, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300049

RESUMO

Spatial light modulators (SLMs) have become an indispensable element in modern optics for their versatile performance in many applications. Among various types of SLMs, such as digital micromirror devices (DMD), liquid crystal-based phase-only spatial light modulators (LC-SLMs), and deformable mirrors (DM), LC-SLMs are often the method of choice due to their high efficiency, precise phase modulation, and abundant number of effective pixels. In general, for research grade applications, an additional SLM calibration step is required due to fabrication imperfection resulting in non-flat liquid crystal panels and varying phase responses over the SLM area. Here, we demonstrate a straightforward approach for reference-free orthogonal calibration of an arbitrary number of SLM subregions which only requires the same measurement time as global calibration. The proposed method requires minimal optical elements and can be applied to any optical setup as is. As a benchmark performance test, we achieved a 2.2-fold enhancement in correction efficiency for wavefront shaping through scattering media utilizing the calibrated 2160 subregions of the SLM, in comparison with a single global look-up table (LUT).

2.
Gastrointest Endosc ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38583543

RESUMO

BACKGROUND AND AIMS: Endobiliary radiofrequency ablation (RFA) is an emerging endoscopic palliative adjunctive therapy used for the local treatment of unresectable malignant biliary obstruction (MBO). However, irregular ablation ranges caused by insufficient electrode-to-bile duct contact pose a significant obstacle. The aim was to investigate the feasibility of a self-expandable stent (SES)-based electrode with a customized RFA generator in the porcine liver and common bile duct (CBD). METHODS: A SES-RFA system with polarity-switching was developed to perform endobiliary RFA. The ablation ranges of 20 ablation protocols were evaluated to validate the feasibility of the newly developed RFA system in the porcine liver. Nine of the 20 ablation protocols were selected for evaluation in the porcine CBD with cholangiography, endoscopy, and histological and immunohistochemical analysis. RESULTS: The SES-RFA system with polarity-switching was successfully constructed and demonstrated high accuracy and reproducibility. The ablation area was clearly identified between the two SESs. The ablation ranges and degree of mucosal damage including TUNEL- and HSP70-positive depositions increased proportionally with ablation protocols in the porcine liver and CBD (all P < .05). Ablation length and depth linearly increased with ablation protocols from 8.74 ± 0.25 to 31.25 ± 0.67 mm and 1.61 ± 0.09 to 11.94 ± 0.44 mm, respectively. CONCLUSIONS: The SES-RFA system with polarity-switching between electrodes provided an even circumferential area of ablation and enhanced ablation depth between the electrodes. This novel endobiliary RFA system is a promising modality for local ablation in patients with unresectable MBO.

3.
J Pineal Res ; 76(1): e12921, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37846173

RESUMO

Evidence suggests that the neuroprotective effects of melatonin involve both receptor-dependent and -independent actions. However, little is known about the effects of melatonin receptor activation on the kainate (KA) neurotoxicity. This study examined the effects of repeated post-KA treatment with ramelteon, a selective agonist of melatonin receptors, on neuronal loss, cognitive impairment, and depression-like behaviors following KA-induced seizures. The expression of melatonin receptors decreased in neurons, whereas it was induced in astrocytes 3 and 7 days after seizures elicited by KA (0.12 µg/µL) in the hippocampus of mice. Ramelteon (3 or 10 mg/kg, i.p.) and melatonin (10 mg/kg, i.p.) mitigated KA-induced oxidative stress and impairment of glutathione homeostasis and promoted the nuclear translocation and DNA binding activity of Nrf2 in the hippocampus after KA treatment. Ramelteon and melatonin also attenuated microglial activation but did not significantly affect astroglial activation induced by KA, despite the astroglial induction of melatonin receptors after KA treatment. However, ramelteon attenuated KA-induced proinflammatory phenotypic changes in astrocytes. Considering the reciprocal regulation of astroglial and microglial activation, these results suggest ramelteon inhibits microglial activation by regulating astrocyte phenotypic changes. These effects were accompanied by the attenuation of the nuclear translocation and DNA binding activity of nuclear factor κB (NFκB) induced by KA. Consequently, ramelteon attenuated the KA-induced hippocampal neuronal loss, memory impairment, and depression-like behaviors; the effects were comparable to those of melatonin. These results suggest that ramelteon-mediated activation of melatonin receptors provides neuroprotection against KA-induced neurotoxicity in the mouse hippocampus by activating Nrf2 signaling to attenuate oxidative stress and restore glutathione homeostasis and by inhibiting NFκB signaling to attenuate neuroinflammatory changes.


Assuntos
Indenos , Melatonina , Camundongos , Animais , Melatonina/farmacologia , Melatonina/metabolismo , Receptores de Melatonina/metabolismo , Ácido Caínico/toxicidade , Ácido Caínico/metabolismo , Fator 2 Relacionado a NF-E2/metabolismo , Hipocampo , Convulsões/induzido quimicamente , Convulsões/tratamento farmacológico , Convulsões/metabolismo , Glutationa/metabolismo , DNA
4.
BMC Gastroenterol ; 24(1): 14, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172745

RESUMO

PURPOSE: To explore the value of clinical application with the whole process computed tomography (CT) guided percutaneous gastrostomy in esophageal tumor patients. MATERIALS AND METHODS: A consecutive series of 32 esophageal tumor patients in whom endoscopic gastrostomy or fluoroscopy guided gastrostomy were considered too dangerous or impossible due to the esophagus complete obstruction, complicate esophageal mediastinal fistula, esophageal trachea fistula or severe heart disease. All of the 32 patients were included in this study from 2 medical center and underwent the gastrostomy under whole process CT guided. RESULTS: All of the gastrostomy procedure was finished successfully under whole process CT guided and the technical success rate was 100%. The average time for each operation was 27 min. No serious complications occurred and the minor complications occurred in 3 patients, including local infection, severe hyperplasia of granulation tissue and tube dislodgment. There were no procedure related deaths. CONCLUSION: The technical success rate of whole process CT guided percutaneous gastrostomy is high and the complication is low. This technique can be used feasible and effectively in some special patients.


Assuntos
Neoplasias Esofágicas , Gastrostomia , Humanos , Gastrostomia/métodos , Endoscopia , Fluoroscopia/métodos , Neoplasias Esofágicas/complicações , Neoplasias Esofágicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos
5.
Neuroradiology ; 66(5): 825-834, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38438630

RESUMO

PURPOSE: The elastase-induced aneurysm (EIA) model in rabbits has been proposed for translational research; however, the adjustment of aneurysm neck size remains challenging. In this study, the technical feasibility and safety of balloon neck-plasty to create a wide-necked aneurysm in rabbit EIA model were investigated. METHODS: Male New Zealand White rabbits (N = 15) were randomly assigned to three groups: group A, EIA creation without neck-plasty; group B, neck-plasty immediately after EIA creation; group C, neck-plasty 4 weeks after EIA creation. The diameter of balloon used for neck-plasty was determined 1 mm larger than origin carotid artery diameter. All rabbits were euthanized 4 weeks after their final surgery. Aneurysm neck, height, dome-to-neck (D/N) ratio, and histologic parameters were compared among the groups. RESULTS: Aneurysm creation was technically successful in 14 out of 15 rabbits (93.3%), with one rabbit experiencing mortality due to an adverse anesthetic event during the surgery. Saccular and wide-necked aneurysms were successfully created in all rabbits. Aneurysm neck was significantly greater in groups B and C compared to group A (all P < .05). D/N ratio was significantly lower in groups B and C compared to group A (all P < .05). Additionally, tunica media thickness, vessel area, and luminal area were significantly greater in groups B and C compared to group A (all P < .05). These variables were found to be significantly greater in group B compared to group C (all P < .05). CONCLUSION: The creation of a wide-necked aneurysm using balloon neck-plasty after elastase induction in rabbits has been determined to be technically feasible and safe.


Assuntos
Aneurisma Intracraniano , Masculino , Coelhos , Animais , Aneurisma Intracraniano/patologia , Elastase Pancreática/efeitos adversos , Modelos Animais de Doenças , Artéria Carótida Primitiva
6.
Small ; 18(25): e2200316, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35570584

RESUMO

To circumvent the limitations of conventional cancer immunotherapy, it is critical to prime antigen-presenting cells (APCs) to initiate the cancer-immune cycle. Here, the authors develop a metal-phenolic network (MPN)-based immunoactive nanoparticle in combination with irreversible electroporation (IRE) for an effective cancer immunotherapy. The MPN nanoparticles are synthesized by coordinating tannic acid with manganese (Mn) ions, and subsequent coating with CpG-oligodeoxynucleotides (CpG-ODNs) via hydrogen bonding. The CpG-ODN-coated Mn-phenolic network (CMP) nanoparticles are effectively internalized into macrophages, a type of APCs, and successfully trigger M1 polarization to promote release of proinflammatory cytokines. Notably, the CMP nanoparticles demonstrate an extended retention time period than the free CpG-ODN in the tumor. The tumor microenvironment tailored bipolar IRE, enhances the therapeutic efficacy by significantly broadening the ablation zone, which further increases immunogenic cell death (ICD). Ultimately, the simultaneous CMP nanoparticles and IRE treatment successfully inhibit tumor growth and prolong survival in a mouse tumor model. Thus, CMP nanoparticles are empowered with Mn and CpG-ODN immunomodulators and the tumor microenvironment tailored bipolar IRE will be a new tool for effective cancer immunotherapy to treat intractable malignancies.


Assuntos
Nanopartículas , Neoplasias , Animais , Camundongos , Eletroporação , Imunoterapia , Neoplasias/terapia , Microambiente Tumoral
7.
Nat Mater ; 20(3): 385-394, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33398120

RESUMO

Polymeric materials have been used to realize optical systems that, through periodic variations of their structural or optical properties, interact with light-generating holographic signals. Complex holographic systems can also be dynamically controlled through exposure to external stimuli, yet they usually contain only a single type of holographic mode. Here, we report a conjugated organogel that reversibly displays three modes of holograms in a single architecture. Using dithering mask lithography, we realized two-dimensional patterns with varying cross-linking densities on a conjugated polydiacetylene. In protic solvents, the organogel contracts anisotropically to develop optical and structural heterogeneities along the third dimension, displaying holograms in the form of three-dimensional full parallax signals, both in fluorescence and bright-field microscopy imaging. In aprotic solvents, these heterogeneities diminish as organogels expand, recovering the two-dimensional periodicity to display a third hologram mode based on iridescent structural colours. Our study presents a next-generation hologram manufacturing method for multilevel encryption technologies.

8.
Ann Surg Oncol ; 28(7): 3983-3993, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33140254

RESUMO

BACKGROUND: Despite surgical resection, early lung adenocarcinoma has a recurrence rate of 20-50%. No clear predictive markers for recurrence of early lung adenocarcinoma are available. Targeted next-generation sequencing (NGS) is rarely used to identify recurrence-related genes. We aimed to identify genetic alterations that can predict recurrence, by comparing the molecular profiles of patient groups with and without recurrence. METHODS: Tissues from 230 patients with resected stage I-II lung adenocarcinoma (median follow-up: 49 months) were analyzed via targeted NGS for 207 cancer-related genes. The recurrence-free survival according to the number and type of mutation was estimated using the Kaplan-Meier method. Independent predictive biomarkers related to recurrence were identified using the Cox proportional hazards model. RESULTS: Recurrence was observed in 64 patients (27.8%). In multivariate analysis adjusted for age, sex, smoking history, stage, surgical mode, and visceral pleural invasion, the CTNNB1 mutation and fusion genes (ALK, ROS1, RET) were negative prognostic factors for recurrence in early-stage lung adenocarcinoma (HR 4.47, p = 0.001; HR 2.73, p = 0.009). EGFR mutation was a favorable factor (HR 0.51, p = 0.016), but the CTNNB1/EGFR co-mutations were negative predictors (HR 19.2, p < 0.001). TP53 mutation was a negative predictor compared with EGFR mutation for recurrence (HR 5.24, p = 0.02). CONCLUSIONS: Targeted NGS can provide valuable information to predict recurrence and identify patients at high recurrence risk, facilitating selection of the treatment strategy among close monitoring and adjuvant-targeted therapy. Larger datasets are required to validate these findings.


Assuntos
Adenocarcinoma de Pulmão , Neoplasias Pulmonares , Adenocarcinoma de Pulmão/genética , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Neoplasias Pulmonares/genética , Mutação , Recidiva Local de Neoplasia/genética , Recidiva Local de Neoplasia/cirurgia , Prognóstico
9.
Surg Endosc ; 35(7): 3492-3505, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32681374

RESUMO

BACKGROUND: Time of diagnosis (TOD) of benign esophageal perforation is regarded as an important risk factor for clinical outcome, although convincing evidence is lacking. The aim of this study is to assess whether time between onset of perforation and diagnosis is associated with clinical outcome in patients with iatrogenic esophageal perforation (IEP) and Boerhaave's syndrome (BS). METHODS: We searched MEDLINE, Embase and Cochrane library through June 2018 to identify studies. Authors were invited to share individual patient data and a meta-analysis was performed (PROSPERO: CRD42018093473). Patients were subdivided in early (≤ 24 h) and late (> 24 h) TOD and compared with mixed effects multivariable analysis while adjusting age, gender, location of perforation, initial treatment and center. Primary outcome was overall mortality. Secondary outcomes were length of hospital stay, re-interventions and ICU admission. RESULTS: Our meta-analysis included IPD of 25 studies including 576 patients with IEP and 384 with BS. In IEP, early TOD was not associated with overall mortality (8% vs. 13%, OR 2.1, 95% CI 0.8-5.1), but was associated with a 23% decrease in ICU admissions (46% vs. 69%, OR 3.0, 95% CI 1.2-7.2), a 22% decrease in re-interventions (23% vs. 45%, OR 2.8, 95% CI 1.2-6.7) and a 36% decrease in length of hospital stay (14 vs. 22 days, p < 0.001), compared with late TOD. In BS, no associations between TOD and outcomes were found. When combining IEP and BS, early TOD was associated with a 6% decrease in overall mortality (10% vs. 16%, OR 2.1, 95% CI 1.1-3.9), a 19% decrease in re-interventions (26% vs. 45%, OR 1.9, 95% CI 1.1-3.2) and a 35% decrease in mean length of hospital stay (16 vs. 22 days, p = 0.001), compared with late TOD. CONCLUSIONS: This individual patient data meta-analysis confirms the general opinion that an early (≤ 24 h) compared to a late diagnosis (> 24 h) in benign esophageal perforations, particularly in IEP, is associated with improved clinical outcome.


Assuntos
Perfuração Esofágica , Doenças do Mediastino , Diagnóstico Precoce , Perfuração Esofágica/diagnóstico , Perfuração Esofágica/etiologia , Perfuração Esofágica/cirurgia , Humanos , Tempo de Internação , Fatores de Risco
10.
Acta Radiol ; 62(3): 329-333, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32517532

RESUMO

BACKGROUND: Although the effectiveness of percutaneous radiologic gastrojejunostomy (PRGJ) has been reported, a detailed description of the indications and clinical effectiveness of temporary PRGJ is still limited. PURPOSE: To evaluate the clinical effectiveness and technical feasibility of temporary PRGJ using the modified Chiba-needle technique with single gastropexy. MATERIAL AND METHODS: Temporary PRGJ using the modified Chiba-needle technique with single gastropexy was performed in 27 consecutive patients (19 men, 8 women; mean age = 61 years; age range = 32-77 years) for esophageal perforation (n = 18) or postoperative gastroparesis (n = 9). Outcomes analyzed included the technical and clinical success, procedure-related complications, and the tube indwelling period. RESULTS: Technical and clinical success was achieved in all 27 patients. All the tubes were electively removed 19-364 days (mean indwelling period = 104 days) after confirmation of the possibility of oral intake. Asymptomatic pneumoperitoneum occurred in 2/27 (7.4%) patients as minor complications and was resolved spontaneously by the time of the one-week follow-up. There were no major complications. During the follow-up period, a total of 11 tube changes were performed in seven patients for an elective tube change within a six-month interval (n = 5) or because of tube occlusion (n = 6). CONCLUSION: Temporary PRGJ using the modified Chiba-needle technique with a single gastropexy was clinically effective and technically feasible in patients with esophageal perforation or gastroparesis. It can provide adequate enteral nutrition during its temporary placement.


Assuntos
Perfuração Esofágica/cirurgia , Derivação Gástrica/métodos , Gastroparesia/cirurgia , Gastropexia/métodos , Adulto , Idoso , Nutrição Enteral , Perfuração Esofágica/diagnóstico , Perfuração Esofágica/etiologia , Estudos de Viabilidade , Feminino , Gastroparesia/diagnóstico , Gastroparesia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
11.
Acta Radiol ; 62(8): 1097-1103, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32811158

RESUMO

BACKGROUND: While removing urinary tract foreign bodies is mostly performed through retrograde cystoscopy, antegrade removal using interventional procedures is reported less frequently. PURPOSE: To evaluate the safety and effectiveness of percutaneous antegrade removal of urinary tract foreign bodies. MATERIAL AND METHODS: A total of 14 consecutive patients (age range 9-80 years) who percutaneous antegrade removal of urinary tract foreign bodies between January 2001 and March 2020 were reviewed. Detailed removal procedures and complications were reviewed retrospectively. RESULTS: Types of foreign bodies were sheared percutaneous nephrostomy (PCN) catheters (n = 5), sheared double J stents (n = 3), migrated ureteral catheters (n = 3), embolization coils (n = 2), and a 0.018-inch guide wire (n = 1). The mean and median indwelling times (range 0-306 days) of the foreign bodies were 58.3 and 1.5 days, respectively. Computed tomography (CT) scans were conducted in six patients, and the extent and nature of the foreign bodies were well-visualized on CT scans. The removal access was new PCN access (n = 8), the tract missing PCN catheter (n = 3), pre-existing PCN access (n = 2), and percutaneous dissection (n = 1). The removal success rate was 92.9% (13/14) with either a simple (n = 8) or modified (n = 4; combination of a snare and guide wire is used) snare technique or a direct forceps grasp (n = 1). The mean procedure time for successful cases was 14.2 min (range 7-25 min). Procedure-related hematoma with (n = 2) or without (n = 1) renal pelvis injury occurred in three patients, which were all self-limited within one week. CONCLUSION: Percutaneous antegrade removal is safe and effective for urinary tract foreign bodies.


Assuntos
Corpos Estranhos/cirurgia , Sistema Urinário , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Corpos Estranhos/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Nefrostomia Percutânea/métodos , Estudos Retrospectivos , Stents , Tomografia Computadorizada por Raios X , Cateteres Urinários , Sistema Urinário/diagnóstico por imagem , Sistema Urinário/cirurgia , Adulto Jovem
12.
Nano Lett ; 20(5): 3435-3441, 2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-32343588

RESUMO

Voltage control of interfacial magnetism has been greatly highlighted in spintronics research for many years, as it might enable ultralow power technologies. Among a few suggested approaches, magneto-ionic control of magnetism has demonstrated large modulation of magnetic anisotropy. Moreover, the recent demonstration of magneto-ionic devices using hydrogen ions presented relatively fast magnetization toggle switching, tsw ∼ 100 ms, at room temperature. However, the operation speed may need to be significantly improved to be used for modern electronic devices. Here, we demonstrate that the speed of proton-induced magnetization toggle switching largely depends on proton-conducting oxides. We achieve ∼1 ms reliable (>103 cycles) switching using yttria-stabilized zirconia (YSZ), which is ∼100 times faster than the state-of-the-art magneto-ionic devices reported to date at room temperature. Our results suggest that further engineering of the proton-conducting materials could bring substantial improvement that may enable new low-power computing scheme based on magneto-ionics.

13.
Nat Methods ; 14(6): 581-583, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28481364

RESUMO

Adaptive optics can correct for optical aberrations. We developed multi-pupil adaptive optics (MPAO), which enables simultaneous wavefront correction over a field of view of 450 × 450 µm2 and expands the correction area to nine times that of conventional methods. MPAO's ability to perform spatially independent wavefront control further enables 3D nonplanar imaging. We applied MPAO to in vivo structural and functional imaging in the mouse brain.


Assuntos
Encéfalo/citologia , Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Lentes , Microscopia de Fluorescência/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Camundongos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Opt Lett ; 45(13): 3381-3384, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32630850

RESUMO

Focusing through scattering media is a subject of great interest due to its direct impact in the field of biomedical optics. However, the greatest barrier currently limiting direct applications is the fact that most scattering media that we wish to deliver light through are dynamic. To focus or deliver light through dynamic scattering media, using a digital micromirror device (DMD) has been demonstrated to be a potential solution, as it enables fast modulation speeds. However, since a DMD is a binary amplitude modulator, the large number of controlled modes needed to acquire adequate focus enhancement has limited optimal usage. Here we demonstrate a novel (to the best of our knowledge) scheme to use the "thrown-away" components of light to effectively use a binary amplitude DMD as a binary phase modulator, thereby increasing the correction efficiency by a factor of two. Our concept can be applied to any iterative optimization algorithm and can speed up the iterative optimization process by increasing the enhancement factor, rather than the measurement or modulation speeds.

15.
Breast Cancer Res Treat ; 173(2): 385-395, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30350268

RESUMO

PURPOSE: Triple-negative breast cancer (TNBC) accounts for 10-20% of all diagnosed BCs and it is enriched in BRCA1 mutation. Guidelines for Western countries suggest that BRCA 1/2 genetic testing should be done for patients with TNBC diagnosed less than 60 years, but there is lack of evidence supporting genetic testing in Asian populations. We determined the prevalence of germline BRCA 1/2 mutations among unselected Korean patients with TNBC and analyzed oncologic outcomes. METHODS: From among 1628 women with TNBC who underwent surgery at Samsung Medical Center (SMC) between Jul 2008 and Jan 2016, 999 samples were available in the SMC biobank for testing germline BRCA 1/2 mutations using next-generation DNA sequencing. RESULTS: Overall, 131 Korean patients (13.1%) had BRCA 1/2 mutations: 97 (9.7%) were in BRCA 1, and 35 (3.5%) were in BRCA 2. One patient had both BRCA 1 and BRCA 2 mutations. Overall, 68 distinct pathologic or likely pathogenic variants (43 BRCA1 and 25 BRCA2) were found. Among those diagnosed at ≤ 60 years, the prevalence of BRCA 1/2 mutation was 14.5%. The mean age of diagnosis of BRCA1/2 mutation carriers was significantly younger than that of non-carriers (45.6 vs. 50.1 years, p < 0.0001). The median follow-up duration was 53.6 months. There were no significant differences in disease-free survival, overall survival, or breast cancer-specific survival (p = 0.799, 0.092, and 0.124, respectively) between BRCA 1/2 carriers and non-carriers, although BRCA 1/2 carriers showed significantly worse contralateral breast cancer-free survival (p < 0.0001) than non-carriers. CONCLUSION: In unselected TNBC patients, we found BRCA 1/2 mutations in 13.1% of overall patients and 14.5% of patients ≤ 60 years. We suggest that Korean women with TNBC diagnosed at ≤ 60 years should be tested for BRCA1/2 mutation.


Assuntos
Proteína BRCA1/genética , Proteína BRCA2/genética , Testes Genéticos/estatística & dados numéricos , Neoplasias de Mama Triplo Negativas/genética , Adulto , Fatores Etários , Povo Asiático/genética , Povo Asiático/estatística & dados numéricos , Análise Mutacional de DNA , Intervalo Livre de Doença , Feminino , Seguimentos , Testes Genéticos/métodos , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Estimativa de Kaplan-Meier , Pessoa de Meia-Idade , República da Coreia/epidemiologia , Estudos Retrospectivos , Neoplasias de Mama Triplo Negativas/diagnóstico , Neoplasias de Mama Triplo Negativas/mortalidade
16.
Opt Lett ; 44(24): 5985-5988, 2019 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-32628199

RESUMO

Imaging through temporally changing aberrations is a common challenge that can be found in many different fields such as astronomy, long-range surveillance, and deep tissue bioimaging. Based on the notions originally developed in speckle interferometry, time-varying aberrations can be used to our advantage to obtain diffraction-limited resolution images through turbulence via bispectrum analysis. However, due to the heavy computational load brought on by the triple correlation and the phase extraction process, widespread use has been limited. Here, we demonstrate a Fourier domain subsampling scheme that can accelerate the speed of bispectrum analysis by more than 2 orders of magnitude. In contrast to other approaches for parallelization such as those based on Radon transform or image segmentation, our proposed method enables diffraction-limited imaging without suffering from resolution loss or image artifacts.

17.
J Vasc Interv Radiol ; 30(10): 1562-1566, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31409566

RESUMO

PURPOSE: To prospectively evaluate the midterm outcomes of fluoroscopic eustachian tube (E-tube) balloon dilation by using a flexible guide wire in patients with obstructive E-tube dysfunction. MATERIALS AND METHODS: From October 2016 to September 2017, adult outpatients with persistent otitis media who were unable to perform the Valsalva maneuver were prospectively enrolled. The analysis included 32 E-tubes from 31 patients (18 women, 13 men; mean age, 47 years old, range 25-72 years). Participants underwent fluoroscopic E-tube balloon dilation with a 0.035-inch flexible guide wire and a 6- × 20-mm balloon catheter. Clinical examinations to check for the ability to perform the Valsalva maneuver and otomicroscopy were conducted at 1 week and then at 1, 3, 12, and 18 months after the procedure. RESULTS: Balloon dilation was technically successful in all E-tubes. The mean time required for the procedure was 6.9 minutes (range, 5.8-10.3 minutes). The Valsalva maneuver was successful in opening 25 of 32 E-tubes (78.1%) at 3 months after balloon dilation. During the median follow-up of 15.9 months, failure of the Valsalva maneuver occurred in 4 of 25 improved E-tubes (16%), yielding a 2-year patency rate of 84%. CONCLUSIONS: The fluoroscopic balloon dilation results were encouraging, and using a flexible guide wire for E-tube balloon dilation did not cause a false passage.


Assuntos
Cateterismo/instrumentação , Catéteres , Otopatias/terapia , Tuba Auditiva/fisiopatologia , Radiografia Intervencionista , Adulto , Idoso , Cateterismo/efeitos adversos , Dilatação , Otopatias/diagnóstico por imagem , Otopatias/fisiopatologia , Desenho de Equipamento , Tuba Auditiva/diagnóstico por imagem , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
19.
Radiology ; 286(1): 140-148, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28787263

RESUMO

Purpose To investigate the use of sirolimus-eluting biodegradable stents (SEBSs) to suppress granulation tissue formation after stent placement in a rat urethral model. Materials and Methods All experiments were approved by the animal research committee. A total of 36 male Sprague-Dawley rats were randomized into three equal groups after biodegradable stent placement. Group A received control biodegradable stents. Groups B and C received stents coated with 90 µg/cm2 and 450 µg/cm2 sirolimus, respectively. Six rats in each group were sacrificed after 4 weeks; the remaining rats were sacrificed after 12 weeks. The therapeutic effectiveness of SEBSs was assessed by comparing the results of retrograde urethrography and histologic examination. Analysis of variance with post hoc comparisons was used to evaluate statistical differences. Results SEBS placement was technically successful in all rats. Urethrographic and histologic examinations revealed significantly less granulation tissue formation at both time points in the rats receiving SEBSs (groups B and C) compared with those that received control stents (group A) (P < .05 for all). There were no significant differences in urethrographic and histologic findings between groups B and C (P > .05 for all). However, the mean number of epithelial layers in group B was higher than that in group C at 4 weeks after stent placement (P < .001). Apoptosis increased in group C compared with groups A and B (P < .05 for all). Conclusion The use of SEBSs suppressed granulation tissue formation secondary to stent placement in a rat urethral model; local therapy with SEBSs may be used to decrease stent-related granulation tissue formation. © RSNA, 2017.


Assuntos
Stents Farmacológicos , Poliésteres/farmacologia , Sirolimo/farmacologia , Uretra/efeitos dos fármacos , Animais , Antibióticos Antineoplásicos/farmacologia , Masculino , Ratos , Ratos Sprague-Dawley , Uretra/citologia , Uretra/patologia
20.
Eur Radiol ; 28(3): 910-919, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28956124

RESUMO

OBJECTIVES: To prospectively evaluate the technical feasibility and safety of fluoroscopy-guided balloon dilation in patients with Eustachian tube (ET) dysfunction. METHODS: Patients who could not do a Valsalva manoeuvre for more than 6 months and diagnosed with chronic otitis media or ET dysfunction were prospectively enrolled. A 0.035-in. guide wire and 6-mm long balloon catheter with a diameter of 2 mm were used to dilate the cartilaginous portion of the ET under fluoroscopic guidance. The balloon was inflated by manual injection twice for 1 min each time. Clinical outcomes were assessed by the patient's ability to perform a Valsalva manoeuvre, and symptoms were assessed using the 7-item Eustachian Tube Dysfunction Questionnaire (ETDQ-7) score. RESULTS: Balloon dilation was attempted in a total of ten adult patients from October 2016 to March 2017. Technical success was achieved in all procedures (10/10). Ninety percent (9/10) of the balloons were fully dilated without waist deformity. There were no major complications. All patients were able to perform a Valsalva manoeuvre at the time of their last visit and/or improvement of at least one ETDQ-7 score. CONCLUSION: Fluoroscopy-guided balloon dilation seems to be technically feasible and safe in the treatment of ET dysfunction. KEY POINTS: • Fluoroscopy-guided balloon dilation without general anaesthesia was well-tolerated in all patients. • Location of the balloon catheter can be monitored during the procedure. • Inflation state of the balloon catheter can be monitored during the procedure. • Using guide-wire during the procedure would prevent false passage creation. • All patients had clinical improvement within 3 months after balloon dilation.


Assuntos
Dilatação/métodos , Endoscopia/métodos , Tuba Auditiva , Fluoroscopia/métodos , Otite Média/terapia , Adulto , Idoso , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Otite Média/diagnóstico , Inquéritos e Questionários , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA