Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Opt Express ; 30(9): 14461-14477, 2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35473188

RESUMO

A large and increasing number of scientific domains pushes for high neutron imaging resolution achieved in reasonable times. Here we present the principle, design and performance of a detector based on infinity corrected optics combined with a crystalline Gd3Ga5O12 : Eu scintillator, which provides an isotropic sub-4 µm true resolution. The exposure times are only of a few minutes per image. This is made possible also by the uniquely intense cold neutron flux available at the imaging beamline NeXT-Grenoble. These comparatively rapid acquisitions are compatible with multiple high quality tomographic acquisitions, opening new venues for in-operando testing, as briefly exemplified here.

2.
ChemSusChem ; 12(12): 2732-2739, 2019 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-30908849

RESUMO

Electrocatalytically active materials on the industrial as well as on the laboratory scale may suffer from chemical instability during operation, air exposure, or storage in the electrolyte. A strategy to recover the loss of electrocatalytic activity is presented. Oxygen-depolarized cathodes (ODC), analogous to those that are utilized in industrial brine electrolysis, are analyzed: the catalytic activity of the electrodes upon storage (4 weeks) under industrial process conditions (30 wt % NaOH, without operation) diminishes. This phenomenon occurs as a consequence of surface oxidation and pore blockage, as revealed by scanning electron microscopy, focused ion beam milling, X-ray photoelectron spectroscopy, and Raman spectroscopy. Potentiodynamic cycling of the oxidized electrodes to highly reductive potentials and the formation of "nascent" hydrogen re-reduces the electrode material, ultimately recovering the former catalytic activity.

3.
Materials (Basel) ; 12(8)2019 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-31003446

RESUMO

Oxygen-depolarized cathodes are a novel concept to be used in chlor-alkali electrolysis in order to generate significant energy savings. In these porous gas diffusion electrodes, hydrophilic and catalytically active microsized silver grains and a hydrophobic polytetrafluoroethylene cobweb structure are combined to obtain the optimum amount of three-phase boundaries between the highly alkaline electrolyte and the oxygen gas phase to achieve high current densities. However, the direct correlation between specific electrode structure and electrochemical performance is difficult. In this work, we report on the successful design and adaptation of an in-operando cell for X-ray (micro-computed tomography, synchrotron) and neutron imaging of an operating oxygen-depolarized cathode under realistic operation conditions, enabling the investigation of the electrolyte invasion into, and distribution inside, the porous electrode for the first time.

4.
Materials (Basel) ; 12(17)2019 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-31443453

RESUMO

Operando laboratory X-ray radiographies were carried out for imaging of two different silver-based gas diffusion electrodes containing an electroconductive Ni mesh structure, one gas diffusion electrode composed of 95 wt.% Ag and 5 wt.% polytetrafluoroethylene and one composed of 97 wt.% Ag and 3 wt.% polytetrafluoroethylene, under different operating parameters. Thereby, correlations of their electrochemical behavior and the transport of the 30 wt.% NaOH electrolyte through the gas diffusion electrodes were revealed. The work was divided into two parts. In the first step, the microstructure of the gas diffusion electrodes was analyzed ex situ by a combination of focused ion beam technology and synchrotron as well as laboratory X-ray tomography and radiography. In the second step, operando laboratory X-ray radiographies were performed during chronoamperometric measurements at different potentials. The combination of the ex situ microstructural analyses and the operando measurements reveals the impact of the microstructure on the electrolyte transport through the gas diffusion electrodes. Hence, an impact of the Ni mesh structure within the gas diffusion electrode on the droplet formation could be shown. Moreover, it could be observed that increasing overpotentials cause increasing electrolyte transport velocities and faster droplet formation due to electrowetting. In general, higher electrolyte transport velocities were found for the gas diffusion electrode with 97 wt.% Ag in contrast to that with 95 wt.% Ag.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA