Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 333
Filtrar
1.
Int J Obes (Lond) ; 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849462

RESUMO

BACKGROUND: Preliminary data suggests that obesity might hasten the decline in mRNA vaccine-induced immunity against SARS-CoV-2. However, whether this renders individuals with obesity more susceptible to long COVID symptoms post-vaccination remains uncertain. Given sleep's critical role in immunity, exploring the associations between obesity, probable long COVID symptoms, and sleep disturbances is essential. METHODS: We analyzed data from a survey of 5919 adults aged 18 to 89, all of whom received two SARS-CoV-2 mRNA vaccinations. Participants were categorized into normal weight, overweight, and obesity groups based on ethnicity-specific BMI cutoffs. The probability of long COVID was evaluated using the Post-Acute Sequelae of SARS-CoV-2 (PASC) score, as our survey did not permit confirmation of acute SARS-CoV-2 infection through methods such as antibody testing. Additionally, sleep patterns were assessed through questionnaires. RESULTS: Participants with obesity exhibited a significantly higher adjusted odds ratio (OR) of having a PASC score of 12 or higher, indicative of probable long COVID in our study, compared to those with normal weight (OR: 1.55, 95% CI: 1.05, 2.28). No significant difference was observed for overweight individuals (OR: 0.92 [95% CI: 0.63, 1.33]). Both obesity and probable long COVID were associated with increased odds of experiencing a heightened sleep burden, such as the presence of obstructive sleep apnea or insomnia (P < 0.001). However, no significant interaction between BMI and probable long COVID status was found. CONCLUSIONS: Even post-vaccination, individuals with obesity may encounter a heightened risk of experiencing prolonged COVID-19 symptoms. However, confirming our observations necessitates comprehensive studies incorporating rigorous COVID infection testing, such as antibody assays - unavailable in our anonymous survey. Additionally, it is noteworthy that the correlation between probable long COVID and sleep disturbances appears to be independent of BMI.

2.
J Sleep Res ; : e14200, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531656

RESUMO

The accreditation of sleep centres aims to ensure high-quality diagnosis and management of sleep centres. European accreditation standards were introduced in 2006, and were aimed at centres offering inpatient polysomnography and vigilance tests (Mean Sleep Latency Test and Maintenance of Wakefulness Test). Since then, the practice of sleep medicine has evolved, with greater use of ambulatory polysomnography and polygraphy. As a result, in many sleep centres, actual clinical practice, although of a high standard, is no longer in accordance with the published guidelines. The current criteria have been revised with the introduction of level-based criteria. Level 1 and 2 centres offer full diagnostic testing in a laboratory-based setting. Level 1 practices will usually be university affiliated, and have a full teaching and active research role. Level 3 and 4 practices may offer both inpatient and ambulatory testing. Level 3 practices perform polysomnography, while level 4 practices (usually monodisciplinary and focussed on sleep apnea) perform polygraphy only. The role of the medical and paramedical team, training, appropriate equipment, patient care pathways and patient management according to national/European recommendations is underlined for accreditation at each level. It is anticipated that the guidelines will be reviewed and if necessary revised after 4 years.

3.
J Sleep Res ; 33(1): e14019, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37646341

RESUMO

Poor sleep quality or sleep deprivation may be related to decreased bone mineral density. We aimed to assess whether associations of sleep characteristics and bone turnover or strength are present in adults from the general population and whether these are independent of common risk factors such as sex, age, and obesity. A total of 1037 participants from the Study of Health in Pomerania-TREND underwent laboratory-based polysomnography and quantitative ultrasound measurements at the heel. Of these participants, 804 completed standardised questionnaires to assess daytime sleepiness, insomnia, and sleep quality. Serum concentrations of two bone turnover markers, intact amino-terminal propeptide of type 1 procollagen (P1NP) and carboxy-terminal telopeptide of type 1 collagen (CTX) were measured. Cross-sectional associations of polysomnography variables (total sleep time, sleep efficiency, time spent wake after sleep onset, oxygen desaturation index, apnea-hypopnea index, and obstructive sleep apnea [OSA]), as well as sleep questionnaire scores with the bone turnover markers and the ultrasound-based stiffness index were assessed in linear regression models. In adjusted models, higher insomnia scores and lower sleep quality scores were related to a higher bone turnover in women but not in men. However, associations between polysomnography variables or questionnaire scores and the stiffness index were absent. Our study provides limited evidence for relationships between sleep characteristics and bone turnover and strength independent of common risk factors for OSA and osteoporosis. Nevertheless, women reporting poor sleep or insomnia in combination with risk factors for osteoporosis might benefit from an evaluation of bone health.


Assuntos
Osteoporose , Apneia Obstrutiva do Sono , Distúrbios do Início e da Manutenção do Sono , Masculino , Adulto , Humanos , Feminino , Distúrbios do Início e da Manutenção do Sono/epidemiologia , Estudos Transversais , Sono , Remodelação Óssea
4.
J Sleep Res ; 33(1): e14020, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37709966

RESUMO

Obstructive sleep apnea is a highly prevalent sleep-related breathing disorder, resulting in a disturbed breathing pattern, changes in blood gases, abnormal autonomic regulation, metabolic fluctuation, poor neurocognitive performance, and increased cardiovascular risk. With broad inter-individual differences recognised in risk factors, clinical symptoms, gene expression, physiological characteristics, and health outcomes, various obstructive sleep apnea subtypes have been identified. Therapeutic efficacy and its impact on outcomes, particularly for cardiovascular consequences, may also vary depending on these features in obstructive sleep apnea. A number of interventions such as positive airway pressure therapies, oral appliance, surgical treatment, and pharmaceutical options are available in clinical practice. Selecting an effective obstructive sleep apnea treatment and therapy is a challenging medical decision due to obstructive sleep apnea heterogeneity and numerous treatment modalities. Thus, an objective marker for clinical evaluation is warranted to estimate the treatment response in patients with obstructive sleep apnea. Currently, while the Apnea-Hypopnea Index is used for severity assessment of obstructive sleep apnea and still considered a major guide to diagnosis and managements of obstructive sleep apnea, the Apnea-Hypopnea Index is not a robust marker of symptoms, function, or outcome improvement. Abnormal cardiac autonomic modulation can provide additional insight to better understand obstructive sleep apnea phenotyping. Heart rate variability is a reliable neurocardiac tool to assess altered autonomic function and can also provide cardiovascular information in obstructive sleep apnea. Beyond the Apnea-Hypopnea Index, this review aims to discuss the role of heart rate variability as an indicator and predictor of therapeutic efficacy to different modalities in order to optimise tailored treatment for obstructive sleep apnea.


Assuntos
Sistema Nervoso Autônomo , Apneia Obstrutiva do Sono , Humanos , Frequência Cardíaca/fisiologia , Resultado do Tratamento , Fatores de Risco
5.
J Sleep Res ; : e14235, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38873908

RESUMO

Sleep trackers are used widely by patients with sleep complaints, however their metrological validation is often poor and relies on healthy subjects. We assessed the metrological validity of two commercially available sleep trackers (Withings Activité/Fitbit Alta HR) through a prospective observational monocentric study, in adult patients referred for polysomnography (PSG). We compared the total sleep time (TST), REM time, REM latency, nonREM1 + 2 time, nonREM3 time, and wake after sleep onset (WASO). We report absolute and relative errors, Bland-Altman representations, and a contingency table of times spent in sleep stages with respect to PSG. Sixty-five patients were included (final sample size 58 for Withings and 52 for Fitbit). Both devices gave a relatively accurate sleep start time with a median absolute error of 5 (IQR -43; 27) min for Withings and -2.0 (-12.5; 4.2) min for Fitbit but both overestimated TST. Withings tended to underestimate WASO with a median absolute error of -25.0 (-61.5; -8.5) min, while Fitbit tended to overestimate it (median absolute error 10 (-18; 43) min. Withings underestimated light sleep and overestimated deep sleep, while Fitbit overestimated light and REM sleep and underestimated deep sleep. The overall kappas for concordance of each epoch between PSG and devices were low: 0.12 (95%CI 0.117-0.121) for Withings and VPSG indications 0.07 (95%CI 0.067-0.071) for Fitbit, as well as kappas for each VPSG indication 0.07 (95%CI 0.067-0.071). Thus, commercially available sleep trackers are not reliable for sleep architecture in patients with sleep complaints/pathologies and should not replace actigraphy and/or PSG.

6.
J Sleep Res ; : e14165, 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38366677

RESUMO

The association between nightmare frequency (NMF) and suicidal ideation (SI) is well known, yet the impact of the COVID-19 pandemic on this relation is inconsistent. This study aimed to investigate changes in NMF, SI, and their association during the COVID-19 pandemic. Data were collected in 16 countries using a harmonised questionnaire. The sample included 9328 individuals (4848 women; age M[SD] = 46.85 [17.75] years), and 17.60% reported previous COVID-19. Overall, SI was significantly 2% lower during the pandemic vs. before, and this was consistent across genders and ages. Most countries/regions demonstrated decreases in SI during this pandemic, with Austria (-9.57%), Sweden (-6.18%), and Bulgaria (-5.14%) exhibiting significant declines in SI, but Italy (1.45%) and Portugal (2.45%) demonstrated non-significant increases. Suicidal ideation was more common in participants with long-COVID (21.10%) vs. short-COVID (12.40%), though SI did not vary by COVID-19 history. Nightmare frequency increased by 4.50% during the pandemic and was significantly higher in those with previous COVID-19 (14.50% vs. 10.70%), during infection (23.00% vs. 8.10%), and in those with long-COVID (18.00% vs. 8.50%). The relation between NMF and SI was not significantly stronger during the pandemic than prior (rs = 0.18 vs. 0.14; z = 2.80). Frequent nightmares during the pandemic increased the likelihood of reporting SI (OR = 1.57, 95% CI 1.20-2.05), while frequent dream recall during the pandemic served a protective effect (OR = 0.74, 95% CI 0.59-0.94). These findings have important implications for identifying those at risk of suicide and may offer a potential pathway for suicide prevention.

7.
Chaos ; 34(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38572945

RESUMO

Interactions between the cardiac and respiratory systems play a pivotal role in physiological functioning. Nonetheless, the intricacies of cardio-respiratory couplings, such as cardio-respiratory phase synchronization (CRPS) and cardio-respiratory coordination (CRC), remain elusive, and an automated algorithm for CRC detection is lacking. This paper introduces an automated CRC detection algorithm, which allowed us to conduct a comprehensive comparison of CRPS and CRC during sleep for the first time using an extensive database. We found that CRPS is more sensitive to sleep-stage transitions, and intriguingly, there is a negative correlation between the degree of CRPS and CRC when fluctuations in breathing frequency are high. This comparative analysis holds promise in assisting researchers in gaining deeper insights into the mechanics of and distinctions between these two physiological phenomena. Additionally, the automated algorithms we devised have the potential to offer valuable insights into the clinical applications of CRC and CRPS.


Assuntos
Coração , Fases do Sono , Frequência Cardíaca/fisiologia , Fases do Sono/fisiologia , Sono/fisiologia , Respiração
8.
Eur Respir J ; 61(1)2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36609518

RESUMO

For more than three decades, type III devices have been used in the diagnosis of sleep disordered breathing in supervised as well as unsupervised settings. They have satisfactory positive and negative predictive values for detecting obstructive and central sleep apnoea in populations with moderately high pre-test probability of symptoms associated with these events. However, standardisation of commercially available type III devices has never been undertaken and the technical specifications can vary widely. None have been subjected to the same rigorous processes as most other diagnostic modalities in the medical field. Although type III devices do not include acquisition of electroencephalographic signals overnight, the minimum number of physical sensors required to allow for respiratory event scoring using standards outlined by the American Academy of Sleep Medicine remains debatable. This technical standard summarises data on type III studies published since 2007 from multiple perspectives in both adult and paediatric sleep practice. Most importantly, it aims to provide a framework for considering current type III device limitations in the diagnosis of sleep disordered breathing while raising research- and practice-related questions aimed at improving our use of these devices in the present and future.


Assuntos
Síndromes da Apneia do Sono , Apneia do Sono Tipo Central , Apneia Obstrutiva do Sono , Criança , Adulto , Humanos , Síndromes da Apneia do Sono/diagnóstico , Sono , Eletroencefalografia
9.
J Sleep Res ; 32(3): e13801, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36579627

RESUMO

Obstructive sleep apnea is a common disorder that leads to sleep fragmentation and is potentially bidirectionally related to a variety of comorbidities, including an increased risk of heart failure and stroke. It is often considered a consequence of anatomical abnormalities, especially in the head and neck, but its pathophysiology is likely to be multifactorial in origin. With geometric morphometrics, and a large sample of adults from the Study for Health in Pomerania, we explore the association of craniofacial morphology to the apnea-hypopnea index used as an estimate of obstructive sleep apnea severity. We show that craniofacial size and asymmetry, an aspect of morphological variation seldom analysed in obstructive sleep apnea research, are both uncorrelated to apnea-hypopnea index. In contrast, as in previous analyses, we find evidence that brachycephaly and larger nasal proportions might be associated to obstructive sleep apnea severity. However, this correlational signal is weak and completely disappears when age-related shape variation is statistically controlled for. Our findings suggest that previous work might need to be re-evaluated, and urge researchers to take into account the role of confounders to avoid potentially spurious findings in association studies.


Assuntos
Craniossinostoses , Insuficiência Cardíaca , Apneia Obstrutiva do Sono , Adulto , Humanos , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/etiologia , Comorbidade , Insuficiência Cardíaca/complicações , Pescoço , Craniossinostoses/complicações
10.
J Sleep Res ; : e14125, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38084019

RESUMO

Obstructive sleep apnea increases morbidity and mortality risks. The most common treatment is continuous positive airway pressure, with nasal mask usage being important, but not always optimal. While most research on treatment adherence focuses on the patient, the bed partner's involvement may be detrimental. Our study aim is to obtain a European-wide picture of the bed partner's attitude and support towards continuous positive airway pressure therapy, including effects on relationship satisfaction and intimacy. The English translation of a German bed partner questionnaire, assessing relationship satisfaction and three major components (general attitude, perceived mask looks, intimacy effects) was distributed within the European Sleep Apnea Database Network and translated in participating countries' local language. Data were collected for 2 years. In total, 10 European countries (13 sleep centres) participated with 1546 questionnaires. Overall, 91% of bed partners had a positive attitude towards continuous positive airway pressure therapy, 86% perceived mask looks not negative, 64% stated no negative intimacy effects. More specifically, 71% mentioned improved sleep quality, 68% supported nightly device usage. For 41% of bed partners, relationship satisfaction increased (no change for 47%). These results were significantly more pronounced in Eastern/Southern Europe compared with Middle Europe, especially regarding intimacy effects. However, increased continuous positive airway pressure therapy length affected attitude negatively. These results provide necessary information to improve treatment strategies by including educational couple-focused approaches. Among others, we revealed that negative intimacy effects are not considered a barrier to continuous positive airway pressure adherence. These results may inspire more research identifying regional gaps with need for treatment adjustments.

11.
J Sleep Res ; 32(3): e13789, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36398720

RESUMO

Recent investigations show that many people affected by SARS-CoV2 (COVID-19) report persistent symptoms 2-3 months from the onset of the infection. Here, we report the Italian findings from the second International COVID-19 Sleep Study survey, aiming to investigate sleep and dream alterations in participants with post-acute symptoms, and identify the best determinants of these alterations among patients with long-COVID. Data from 383 participants who have had COVID-19 were collected through a web-survey (May-November 2021). Descriptive analyses were performed to outline the sociodemographic characteristics of long-COVID (N = 270, with at least two long-lasting symptoms) and short-COVID (N = 113, with none or one long-lasting symptom) participants. They were then compared concerning sleep and dream measures. We performed multiple linear regressions considering as dependent variables sleep and dream parameters discriminating the long-COVID group. Age, gender, work status, financial burden, COVID-19 severity and the level of care were significantly different between long-COVID and short-COVID subjects. The long-COVID group showed greater sleep alterations (sleep quality, daytime sleepiness, sleep inertia, naps, insomnia, sleep apnea, nightmares) compared with the short-COVID group. We also found that the number of long-COVID symptoms, psychological factors and age were the best explanatory variables of sleep and oneiric alterations. Our findings highlight that sleep alterations are part of the clinical presentation of the long-COVID syndrome. Moreover, psychological status and the number of post-acute symptoms should be considered as state-like variables modulating the sleep problems in long-COVID individuals. Finally, according to previous investigations, oneiric alterations are confirmed as a reliable mental health index.


Assuntos
COVID-19 , Síndrome de COVID-19 Pós-Aguda , Humanos , RNA Viral , SARS-CoV-2 , Sono
12.
J Sleep Res ; 32(1): e13613, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35474255

RESUMO

There has been increasing concern about the long-term impact of coronavirus disease 2019 (COVID-19) as evidenced by anecdotal case reports of acute-onset parkinsonism and the polysomnographic feature of increased rapid eye movement sleep electromyographic activity. This study aimed to determine the prevalence and correlates of dream-enactment behaviours, a hallmark of rapid eye movement sleep behaviour disorder, which is a prodrome of α-synucleinopathy. This online survey was conducted between May and August 2020 in 15 countries/regions targeting adult participants (aged ≥18 years) from the general population with a harmonised structured questionnaire on sleep patterns and disorders, COVID-19 diagnosis and symptoms. We assessed dream-enactment behaviours using the Rapid Eye Movement Sleep Behaviour Disorder Single-Question Screen with an additional question on their frequency. Among 26,539 respondents, 21,870 (82.2%) answered all items that were analysed in this study (mean [SD] age 41.6 [15.8] years; female sex 65.5%). The weighted prevalence of lifetime and weekly dream-enactment behaviours was 19.4% and 3.1% and were found to be 1.8- and 2.9-times higher in COVID-19-positive cases, respectively. Both lifetime and weekly dream-enactment behaviours were associated with young age, male sex, smoking, alcohol consumption, higher physical activity level, nightmares, COVID-19 diagnosis, olfactory impairment, obstructive sleep apnea symptoms, mood, and post-traumatic stress disorder features. Among COVID-19-positive cases, weekly dream-enactment behaviours were positively associated with the severity of COVID-19. Dream-enactment behaviours are common among the general population during the COVID-19 pandemic and further increase among patients with COVID-19. Further studies are needed to investigate the potential neurodegenerative effect of COVID-19.


Assuntos
COVID-19 , Transtorno do Comportamento do Sono REM , Adulto , Humanos , Masculino , Feminino , Adolescente , Transtorno do Comportamento do Sono REM/diagnóstico , Transtorno do Comportamento do Sono REM/epidemiologia , Transtorno do Comportamento do Sono REM/complicações , Pandemias , Teste para COVID-19 , COVID-19/epidemiologia , Sonhos
13.
J Sleep Res ; 32(1): e13754, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36208038

RESUMO

Many people report suffering from post-acute sequelae of COVID-19 or "long-COVID", but there are still open questions on what actually constitutes long-COVID and how prevalent it is. The current definition of post-acute sequelae of COVID-19 is based on voting using the Delphi-method by the WHO post-COVID-19 working group. It emphasizes long-lasting fatigue, shortness of breath and cognitive dysfunction as the core symptoms of post-acute sequelae of COVID-19. In this international survey study consisting of 13,628 subjects aged 18-99 years from 16 countries of Asia, Europe, North America and South America (May-Dec 2021), we show that post-acute sequelae of COVID-19 symptoms were more prevalent amongst the more severe COVID-19 cases, i.e. those requiring hospitalisation for COVID-19. We also found that long-lasting sleep symptoms are at the core of post-acute sequelae of COVID-19 and associate with the COVID-19 severity when COVID-19 cases are compared with COVID-negative cases. Specifically, fatigue (61.3%), insomnia symptoms (49.6%) and excessive daytime sleepiness (35.8%) were highly prevalent amongst respondents reporting long-lasting symptoms after hospitalisation for COVID-19. Understanding the importance of sleep-related symptoms in post-acute sequelae of COVID-19 has a clinical relevance when diagnosing and treating long-COVID.


Assuntos
COVID-19 , Distúrbios do Sono por Sonolência Excessiva , Distúrbios do Início e da Manutenção do Sono , Humanos , Sono , Distúrbios do Sono por Sonolência Excessiva/diagnóstico , Fadiga , Distúrbios do Início e da Manutenção do Sono/etiologia , Distúrbios do Início e da Manutenção do Sono/complicações , Síndrome de COVID-19 Pós-Aguda
14.
Sleep Breath ; 27(4): 1315-1323, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36269514

RESUMO

PURPOSE: Despite polysomnography being the gold standard method of diagnosing obstructive sleep apnea (OSA), it is time-consuming and has long waiting lists. Alternative methods including questionnaires and portable sleep devices have been developed to increase the speed of diagnosis. However, most questionnaires such as the STOP-BANG questionnaire (SBQ) are limited due to low specificity. This study evaluated the value of SBQ to screen for OSA and compared it with the oxygen desaturation index (ODI) and their combination. METHODS: This retrospective study included patients who completed the SBQ and underwent a night at the sleep lab or home sleep testing. The ODI was extracted from these sleep study reports. The combination of SBQ with ODI and their individual scores were compared with apnea-hypopnea index (AHI) in terms of their accuracy in diagnosing OSA. Sensitivity, specificity, and area under the curve (AUC) for different severities of OSA were calculated and compared. RESULTS: Among 132 patients, SBQ showed a sensitivity of 0.9 and a specificity of 0.3 to screen for OSA. As the severity of OSA increased, the sensitivity increased whilst specificity decreased for both measurements. ODI achieved an increased specificity of 0.8 and could correctly diagnose OSA 86% of the time which was better than SBQ's 60%. For all severities of OSA, ODI alone displayed a larger AUC than SBQ and similar AUC to their combination. CONCLUSION: ODI produced a higher specificity and AUC than SBQ. Furthermore, ODI combined with SBQ failed to increase diagnostic value. Therefore, ODI may be the preferred way to initially screen patients for OSA as an easy-to-use alternative compared to SBQ.


Assuntos
Oxigênio , Apneia Obstrutiva do Sono , Humanos , Estudos Retrospectivos , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/epidemiologia , Alemanha , Inquéritos e Questionários , Programas de Rastreamento/métodos
15.
Sleep Breath ; 27(1): 283-289, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35486312

RESUMO

OBJECTIVE: This study aimed to evaluate the effect of sacubitril-valsartan (SV) on central apneas (CA) and obstructive apneas (OA) in patients with heart failure with reduced ejection fraction (HFrEF). METHODS: In patients with HFrEF, SV initiation was titrated to the highest tolerable dosage. Patients were evaluated with portable apnea monitoring, echocardiography, and cardiopulmonary exercise testing at baseline and 3 months later. RESULTS: Of a total of 18 patients, 9 (50%) had OA, 7 (39%) had CA, and 2 (11%) had normal breathing. SV therapy was related to a reduction in NT-pro BNP and an improvement in LV function after 3 months. Portable apnea monitoring revealed a significant decrease of the respiratory event index (REI) after treatment with SV (20 ± 23 events/h to 7 ± 7 events/h, p = 0.003). When subgrouping according to type of apneas, REI, and time spent below 90% saturation (T90) decreased in patients with CA and OA (all p < 0.05). CONCLUSION: In this prospective study, SV treatment for 3 months in patients with CA and OA is associated with a significant decrease in REI.


Assuntos
Obstrução das Vias Respiratórias , Insuficiência Cardíaca , Síndromes da Apneia do Sono , Apneia do Sono Tipo Central , Apneia Obstrutiva do Sono , Humanos , Insuficiência Cardíaca/tratamento farmacológico , Estudos Prospectivos , Volume Sistólico , Apneia Obstrutiva do Sono/tratamento farmacológico , Apneia do Sono Tipo Central/tratamento farmacológico
16.
Sleep Breath ; 27(4): 1455-1463, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36472730

RESUMO

PURPOSE: To investigate the cross-sectional associations of daytime sleepiness with coronary plaque volume and composition in patients with obstructive sleep apnea (OSA), and whether or not these associations are modified by age, gender, and obesity. METHODS: Patients who were confirmed with OSA through respiratory polygraphy and also underwent coronary CTA at a tertiary hospital were consecutively enrolled. The interval between the sleep monitoring and coronary CTA scan was < 3 months. Every patient completed the Epworth sleepiness scale (ESS) to assess daytime sleepiness, and an ESS score of ≥ 11 was recognized as excessive daytime sleepiness (EDS). Coronary plaque volume and composition were measured using semi-automatic software. RESULTS: Of the 394 patients with OSA (median [IQR] age, 56.0 [49.0-64.0] years; median [IQR] body mass index, 27.9 [25.5-30.2] kg/m2; median [IQR] apnea-hypopnea index, 21.3 [11.7, 36.3] events/h), a total of 200 patients had EDS. In the overall participants, a significant dose-response relationship between ESS scores and low-attenuation plaque volume was found in the fully adjusted model (P = 0.019). Further analysis demonstrated that there was a significant interactive effect of ESS levels and obesity on coronary plaque volume (all P values for interaction analysis < 0.05). Specifically, ESS levels were associated with total plaque volume, volumes of noncalcified, low-attenuation, and calcified plaque (P = 0.008, 0.006, 0.005, and 0.043 respectively) in obese patients with OSA. CONCLUSION: Daytime sleepiness is significantly correlated with increased coronary plaque burden among patients with OSA. Thus, clinicians should recognize that patients with OSA reporting high ESS scores, especially those with obesity, are more prone to experience adverse coronary events.


Assuntos
Distúrbios do Sono por Sonolência Excessiva , Apneia Obstrutiva do Sono , Humanos , Pessoa de Meia-Idade , Estudos Transversais , Distúrbios do Sono por Sonolência Excessiva/diagnóstico , Distúrbios do Sono por Sonolência Excessiva/epidemiologia , Distúrbios do Sono por Sonolência Excessiva/complicações , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/complicações , Obesidade/complicações , Inquéritos e Questionários
17.
Sleep Breath ; 27(4): 1411-1418, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36414783

RESUMO

OBJECTIVES: The emergence of sleep disturbances in response to major stressful events has been previously documented. Heart rate variability (HRV) is an objective marker that provides insight into autonomic nervous system dynamics. The aim of the present study was to examine the preliminary effectiveness of a one-shot session of cognitive behavioral therapy for insomnia (CBT-I) for frontline healthcare providers with acute insomnia. METHODS: This study was conducted from 2020 to 2021 on healthcare workers with insomnia. The healthcare workers were randomly allocated to receive either one-shot cognitive behavioral therapy or routine care. Insomnia severity index (ISI) and heart rate variability were assessed before and 1 month after the interventions. RESULTS: Among 57 patients (n = 31 in the intervention group and n = 26 in the control group), mean (± SD) age of both groups were 34.6 (± 9.5) and 36.6 (± 6.9), respectively. Most participants in both groups were female (81% and 65% in the intervention and control groups, respectively; p-value = 0.10). Insomnia severity index score decreased in the intervention group from 13.3 to 6.7 (p < 0.001). The change before and after the intervention was significant between the two groups for HF-normalized unit (high-frequency power band [0.15-0.40 Hz] in the normalized unit) and LF/HF (the ratio of low frequency to high frequency). HF-normalized unit increased in the intervention group (35.8 ± 21.5 vs. 45.6 ± 19.8 before and after the intervention, respectively), and decreased in the control group (43.9 ± 16.5 vs. 39.8 ± 18.5, before and after the intervention, respectively). CONCLUSION: The findings suggest that a single-shot session of cognitive behavioral therapy for insomnia is effective in managing acute insomnia symptoms in healthcare workers.


Assuntos
COVID-19 , Terapia Cognitivo-Comportamental , Distúrbios do Início e da Manutenção do Sono , Humanos , Feminino , Masculino , Distúrbios do Início e da Manutenção do Sono/terapia , Frequência Cardíaca , Pandemias , Pessoal de Saúde , Resultado do Tratamento
18.
Sleep Breath ; 27(3): 1027-1032, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35978055

RESUMO

OBJECTIVE: Central sleep apnea (CSA) is associated with increased morbidity and mortality in patients with heart failure (HF). We aimed to explore the effectiveness of phrenic nerve stimulation (PNS) on CSA in patients with HF. METHODS: This was a prospective and non-randomized study. The stimulation lead was inserted into the right brachiocephalic vein and attached to a proprietary neurostimulator. Monitoring was conducted during the implantation process, and all individuals underwent two-night polysomnography. RESULTS: A total of nine subjects with HF and CSA were enrolled in our center. There was a significant decrease in the apnea-hypopnea index (41 ± 18 vs 29 ± 25, p = 0.02) and an increase in mean arterial oxygen saturation (SaO2) (93% ± 1% vs 95% ± 2%, p = 0.03) after PNS treatment. We did not observe any significant differences of oxygen desaturation index (ODI) and SaO2 < 90% (T90) following PNS. Unilateral phrenic nerve stimulation might also categorically improve the severity of sleep apnea. CONCLUSION: In our non-randomized study, PNS may serve as a therapeutic approach for CSA in patients with HF.


Assuntos
Terapia por Estimulação Elétrica , Insuficiência Cardíaca , Apneia do Sono Tipo Central , Humanos , Resultado do Tratamento , Nervo Frênico , Apneia do Sono Tipo Central/terapia , Apneia do Sono Tipo Central/complicações , Estudos Prospectivos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia
19.
Sleep Breath ; 27(2): 459-467, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35486311

RESUMO

PURPOSE: Socioeconomic factors are known to modulate health. Concerning sleep apnea, influences of income, education, work, and living in a partnership are established. However, results differ between national and ethnic groups. Results also differ between various clinical studies and population-based approaches. The goal of our study was to determine if such factors can be verified in the population of Pomerania, Germany. METHODS: A subgroup from the participants of the population-based Study of Health in Pomerania volunteered for an overnight polysomnography. Their data were subjected to an ordinal regressions analysis with age, sex, body mass index (BMI), income, education, work, and life partner as predictors for the apnea-hypopnea index. RESULTS: Among the subgroup (N = 1209) from the population-based study (N = 4420), significant effects were found for age, sex, and BMI. There were no significant effects for any of the socioeconomic factors. CONCLUSION: Significant effects for well-established factors as age, sex, and BMI show that our study design has sufficient power to verify meaningful associations with sleep apnea. The lack of significant effects for the socioeconomic factors suggests their clinical irrelevance in the tested population.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia , Síndromes da Apneia do Sono/complicações , Fatores Socioeconômicos , Polissonografia/métodos , Alemanha , Índice de Massa Corporal
20.
BMC Public Health ; 23(1): 2352, 2023 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-38017498

RESUMO

BACKGROUND: Self-rated health (SRH) is widely recognized as a clinically significant predictor of subsequent mortality risk. Although COVID-19 may impair SRH, this relationship has not been extensively examined. The present study aimed to examine the correlation between habitual sleep duration, changes in sleep duration after infection, and SRH in subjects who have experienced SARS-CoV-2 infection. METHODS: Participants from 16 countries participated in the International COVID Sleep Study-II (ICOSS-II) online survey in 2021. A total of 10,794 of these participants were included in the analysis, including 1,509 COVID-19 individuals (who reported that they had tested positive for COVID-19). SRH was evaluated using a 0-100 linear visual analog scale. Habitual sleep durations of < 6 h and > 9 h were defined as short and long habitual sleep duration, respectively. Changes in habitual sleep duration after infection of ≤ -2 h and ≥ 1 h were defined as decreased or increased, respectively. RESULTS: Participants with COVID-19 had lower SRH scores than non-infected participants, and those with more severe COVID-19 had a tendency towards even lower SRH scores. In a multivariate regression analysis of participants who had experienced COVID-19, both decreased and increased habitual sleep duration after infection were significantly associated with lower SRH after controlling for sleep quality (ß = -0.056 and -0.058, respectively, both p < 0.05); however, associations between current short or long habitual sleep duration and SRH were negligible. Multinomial logistic regression analysis showed that decreased habitual sleep duration was significantly related to increased fatigue (odds ratio [OR] = 1.824, p < 0.01), shortness of breath (OR = 1.725, p < 0.05), diarrhea/nausea/vomiting (OR = 2.636, p < 0.01), and hallucinations (OR = 5.091, p < 0.05), while increased habitual sleep duration was significantly related to increased fatigue (OR = 1.900, p < 0.01). CONCLUSIONS: Changes in habitual sleep duration following SARS-CoV-2 infection were associated with lower SRH. Decreased or increased habitual sleep duration might have a bidirectional relation with post-COVID-19 symptoms. Further research is needed to better understand the mechanisms underlying these relationships for in order to improve SRH in individuals with COVID-19.


Assuntos
COVID-19 , Duração do Sono , Humanos , COVID-19/epidemiologia , SARS-CoV-2 , Inquéritos e Questionários , Fadiga/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA