1.
Graefes Arch Clin Exp Ophthalmol ; 261(2): 521-533, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35986778

RESUMO

PURPOSE: The aim of this study was to determine the preoperative characteristics influencing hypotensive efficacy of the XEN45 gel stent in patients with open-angle glaucoma at one-year follow-up. MATERIALS AND METHODS: This was a retrospective multicentre study. All patients who underwent XEN45 gel stent implantation between January 2017 and January 2021 were included. The main study outcome was the assessment of one-year postoperative intraocular pressure (IOP) and glaucoma medication differences according to the number and type of preoperative topical treatments or glaucoma surgery, glaucoma stage and time since diagnosis. Follow-up period was 1-year post-surgery in all cases. IOP reduction and surgery success (not requiring reoperation or pressure failures [IOP > 18 mmHg and < 20% reduction in IOP]), safety and cost savings in topical glaucoma therapy after surgery were secondarily assessed. Linear regression analysis to determine the preoperative parameters influence on 1-year postoperative results was performed. RESULTS: XEN45 gel stent was implanted in 85 patients. One-year postoperative mean IOP dropped from 20.6 ± 4.1 to 13.7 ± 2.8 mmHg (p < 0.0001). Likewise, mean number of topical treatments decreased from 2.05 ± 0.9 to 0.36 ± 0.65 (p < 0.001). Both were mainly influenced by the number of preoperative glaucoma treatments, such that for each one-glaucoma medication increase, postoperative intraocular pressure increased by 1.18 mmHg (95% CI 0.56-1.79, p < 0.0001) and number of glaucoma medications increased by 0.3 (95% CI 0.16-0.43, p < 0.001). Overall success rates (with and without supplemental glaucoma medication use) were 97.6% (95% CI 94.5-100%), 87.1% (95% CI 80.2-87.1%) and 61.2% (95% CI 51.6-72.5%) at 3, 6 months and 1 year after surgery. No sight-threatening adverse events were reported. Mean annual cost savings on medical treatment since surgery reached EUR 251.19 ± 169. 93 euros. CONCLUSIONS: One year after surgery, XEN45 gel implant significantly reduced IOP and number of topical medications with an adequate safety profile being both mainly influenced by the number of preoperative glaucoma treatments.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Desenho de Prótese , Resultado do Tratamento , Glaucoma/cirurgia , Pressão Intraocular , Stents , Estudos Retrospectivos
2.
Graefes Arch Clin Exp Ophthalmol ; 261(5): 1349-1357, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36536223

RESUMO

PURPOSE: This study aims to evaluate the efficacy and safety of the PreserFlo MicroShunt (Santen, Osaka, Japan) in lowering intraocular pressure (IOP) in childhood glaucoma patients with previous failed glaucoma surgeries. METHODS: This is a prospective case review of consecutive PreserFlo procedures performed in childhood glaucoma patients after failed surgeries. Age, sex, diagnosis, and previous glaucoma surgeries, as well as visual acuity, IOP, and treatment in the preoperative visit and all follow-up visits were collected. Outcome measures included IOP reduction from baseline, mean IOP change from baseline at month 6, medication use at 6 months, complications, adverse events, and need for further procedures. RESULTS: Fourteen patients were included, 8 (57%) males and 6 (43%) females; the mean age was 27.5 ± 13.5 years. Nine patients (64%) had at least two trabeculectomies, and 6 patients (43%) had at least one trabeculectomy and a glaucoma drainage implant. The mean IOP change from baseline was 11.3 ± 4.9 mmHg at 12 months. At 12 months, 12 patients (86%) presented ≥ 20% IOP lowering from baseline, and 11 patients (79%) presented ≥ 30%. The mean medication count decreased from 3.9 ± 0.7 (baseline) to 0.7 ± 1.3 (12 months). No intraoperative complications were reported. No adverse events were noted. No secondary filtration surgery was required, although bleb needling was required in one case, 1 month after the surgery. CONCLUSIONS: PreserFlo with MMC can be used successfully to treat uncontrolled IOP in childhood glaucoma cases with previous failed surgeries. Larger studies with longer follow-up are needed to further explore the role of the device in resistant childhood glaucoma cases.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Trabeculectomia , Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Mitomicina/uso terapêutico , Glaucoma/tratamento farmacológico , Trabeculectomia/métodos , Pressão Intraocular , Resultado do Tratamento
3.
Eur J Ophthalmol ; 34(1): 186-192, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37157825

RESUMO

PURPOSE: The aim of this study is to analyze the distribution of visual field (VF) mean defect (MD) in six subgroups of glaucoma patients at baseline and follow-up. METHODS: We assessed glaucoma patients treated in a Spanish tertiary care setting with a follow-up of at least 10 months. We have included 1036 visual fields and the following glaucoma subtypes: open-Angle Glaucoma (OAG); Angle-Closure Glaucoma (ACG); Congenital Glaucoma (CG); Ocular hypertension (OHT); Pseudoexfoliative Glaucoma (PSXG); Pigmentary Glaucoma (PG). We have calculated the baseline MD and the progression MD. We have stratified the MD progression in slow (MD rate > -0.5 dB/year); moderate (MD rate between -0.5 and -1 dB/year) fast (MD rate between -1 and -2 dB/year) and catastrophic (<-2 dB/year) progression and their glaucoma subtype. RESULTS: The glaucoma types with the worse baseline MD were CG and PG. We found significant differences after comparing the baseline MD of CG and OAG, ACG, OHT and between PG and OHT. Concerning the MD progression rate: OAG 73.54% showed slow MD progression rate; 9.85% fast; 7.3% moderate and 9.3% catastrophic. ACG 82.22% slow; 8.89% moderate; 2.22% fast and 6.67% catastrophic. CG 68.83% slow; 9.09% fast; 7.79% moderate and 14.29% catastrophic. OHT 88.6% slow; 6.14% moderate; 4.39% fast and 0.88% catastrophic. PSXG 63.24% slow, 13.24% moderate; 8.8% fast and 14.7% catastrophic. PG 89.29% slow; 3.57% moderate and 7.1% fast. CONCLUSIONS: The CG requires special attention because of its aggressive presentation and progression.


Assuntos
Glaucoma de Ângulo Fechado , Glaucoma de Ângulo Aberto , Glaucoma , Hidroftalmia , Hipertensão Ocular , Humanos , Campos Visuais , Pressão Intraocular , Progressão da Doença , Testes de Campo Visual , Transtornos da Visão , Estudos Retrospectivos
4.
Eye (Lond) ; 37(2): 267-273, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35013610

RESUMO

OBJECTIVE: To evaluate the differences in peripapillary and macular vascular parameters by optical coherence tomography angiography (OCTA) between patients with primary congenital glaucoma (PCG) and healthy controls; and to determine their diagnostic accuracy. MATERIAL AND METHODS: Observational, cross-sectional study including 39 eyes with PCG and 78 healthy eyes. Only one eye per patient was included. All included patients underwent a comprehensive ophthalmic examination and peripapillary and macular analysis were performed by AngioplexTM OCTA (Cirrus HD-OCT 5000) with a 4.5 × 4.5 mm optic nerve head scan and 6 × 6 mm macular scan. Global data and quadrant data from peripapillary vascular parameters and global data and circular sectors data from macular superficial plexus parameters were compared between groups. The glaucoma discrimination capability of these parameters was calculated as areas under the receiver operating characteristics curve (AUC ROC). RESULTS: Mean age was 14.1 ± 8.7 years for the PCG patients and 11.7 ± 6.2 years for controls (p = 0.093). All vascular peripapillary measurements (global and quadrants; all p < 0.001) and all macular measurements (p < 0.042) excepting perfusion density in the inner circle (p = 0.087), were reduced in the PCG group compared to controls. According to AUC ROC, peripapillary (all ≥ 0.706) and macular parameters (all ≥ 0.699) showed good diagnostic capacity. AUC ROC for the most discriminatory measurements corresponding to blood flux index (0.887) and whole macula vascular density (0.855) were similar (p = 0.085). CONCLUSION: Peripapillary and macular vascular parameters by OCTA are decreased in patients with PCG, showing a good capacity to discriminate between normal and glaucomatous eyes.


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Humanos , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Tomografia de Coerência Óptica/métodos , Pressão Intraocular , Estudos Transversais , Campos Visuais , Glaucoma/diagnóstico , Angiofluoresceinografia/métodos , Vasos Retinianos/diagnóstico por imagem
5.
Adv Ther ; 39(9): 3916-3932, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35797002

RESUMO

The surgical management of glaucoma has been revolutionized by the introduction of minimally invasive glaucoma surgery (MIGS). The various MIGS options aim to meaningfully lower intraocular pressure with a better safety profile than traditional glaucoma surgery. The key clinical attributes and the emerging potential of an ab externo MicroShunt (PreserFlo™) are reviewed in the context of published evidence and clinical experience. This novel MicroShunt consists of an 8.5-mm-long tube that is implanted in the eye via an ab externo approach enabling aqueous humor drainage into the sub-Tenon's space through the formation of a bleb, similar in appearance to that created by trabeculectomy. The efficacy and safety of this procedure, the concomitant use of antimetabolites, the impact of tube positioning, and its future value in clinical practice are critically reviewed. Recent evidence has demonstrated the MicroShunt to be less effective than traditional filtration surgery, but with a significant improvement in safety. Cumulative data suggest that the new implant provides tangible clinical benefits to selected patients with glaucoma in need of further intraocular pressure (IOP) lowering. Future research should delineate the precise role of this and other MIGS options in the rapidly evolving glaucoma treatment algorithm.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Trabeculectomia , Humor Aquoso , Glaucoma/tratamento farmacológico , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Tonometria Ocular , Trabeculectomia/métodos
6.
J Glaucoma ; 30(5): 444-450, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33394845

RESUMO

PURPOSE: The purpose of this study was to compare corneal topography and densitometry measurements in patients with primary open-angle glaucoma (POAG) and healthy subjects. PATIENTS AND METHODS: A total of 200 eyes of 75 patients with POAG and 125 healthy controls underwent corneal topography and densitometry (Oculus Pentacam HR). The data compared in the 2 groups were: anterior chamber angle, anterior chamber depth, and anterior chamber volume, keratometry (Kminimum, Kmaximum, and Kmean), central corneal thickness, central anterior elevation, anterior elevation apex, maximum anterior elevation, and posterior elevation apex. Densitometry measurements were made at 3 depths on a 12-mm-diameter circle divided into 4 concentric rings (0 to 2, 2 to 6, 6 to 10, and 10 to 12 mm). The diagnostic capacity of the corneal variables was assessed through the areas under the receiver operating characteristics curve. RESULTS: The corneal density of practically all depth layers and total corneal density were significantly higher in the POAG than the control group (P<0.05). Total corneal density was positively correlated with age (r=0.623; P<0.001) and also showed a good diagnostic capacity for glaucoma [area under the curve=0.617; 95% confidence interval (CI): 0.541-0.697; P<0.001]. In a multiple linear regression designed to assess its relationship with age, sex, central corneal thickness, and Kmean, age emerged as a significant confounder both in controls (coefficient=0.315; P<0.001; 95% CI: 0.246-0.384) and patients (coefficient=0.370; P<0.001; 95% CI: 0.255-0.486). CONCLUSION: Corneal densitometry measurements showed a good diagnostic capacity for POAG suggesting this type of examination could have clinical applications in the diagnosis and management of glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Córnea/diagnóstico por imagem , Topografia da Córnea , Densitometria , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Pressão Intraocular
7.
Can J Ophthalmol ; 56(6): 364-370, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33577755

RESUMO

OBJECTIVE: To describe corneal densitometry, topographic measurements, and biomechanical properties in patients with primary congenital glaucoma (PCG) and healthy patients. To examine correlations between variables and determine their glaucoma diagnostic capacity. METHODS: This was a cross-sectional, case-control study conducted in 50 eyes of 50 patients with PCG (G1) and 40 eyes of 40 healthy patients (G2). The variables determined in each participant were: intraocular pressure, best corrected visual acuity (BCVA), corneal densitometry, topographic data using the Pentacam HR-Scheimpflug imaging system (Oculus Optikgerate GmbH, Wetzlar, Germany), and corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Depew, NY). RESULTS: Overall densitometry was significatively higher in the PCG group (G1: 17.94 ± 4.99 vs G2: 13.25 ± 1.96, p < 0.001). CH (G1: 8.02 ± 11.35 vs G2: 11.35 ± 1.42, p < 0.001) and CRF (G1: 9.48 ± 2.83 vs G2: 10.77 ± 1.34, p < 0.001) were lower in the glaucoma group. Mean posterior, central, and anterior elevation and mean keratometry were higher in G1 (p < 0.05). In the PCG group, overall densitometry showed significant correlation with CH (r = -0.321, p = 0.028) and with BCVA (r = -0.498, p = 0.002). AUCs (areas under the curve) for CH and overall densitometry were high (0.839 and 0.899 respectively) and the best overall densitometry; CH and CRF cutoffs were 14.0, 9.3 and 9.2 respectively. CONCLUSION: Densitometry is increased, and biomechanical corneal properties are decreased in patients with PCG. Densitometry and visual acuity showed a negative and significant correlation, so this measurement could be used as an indirect parameter of BCVA in the clinical practice.


Assuntos
Córnea , Glaucoma , Fenômenos Biomecânicos , Estudos de Casos e Controles , Estudos Transversais , Densitometria , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Tonometria Ocular
8.
J Glaucoma ; 29(10): 864-871, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32769736

RESUMO

PRECIS: In this European study (STAR-II), MINIject, a novel, ab-interno, supraciliary minimally invasive glaucoma surgery device, effectively lowered intraocular pressure (IOP) and the need for IOP-lowering medications in patients with primary open-angle glaucoma. PURPOSE: This study evaluates the safety and performance of a minimally invasive supraciliary glaucoma drainage device (MINIject DO627) for surgical treatment of primary open-angle glaucoma in patients refractory to topical hypotensive medications. METHODS: In a prospective, interventional, single-arm, multicenter, European study (STAR-II), MINIject was successfully implanted in a stand-alone procedure in 29 of 31 patients in 8 sites in 3 countries. The primary endpoint was the success rate 6 months after surgery >60% (defined as diurnal IOP ≤21 and >5 mm Hg with ≥20% IOP reduction from baseline, with/without glaucoma hypotensive medication). ClinicalTrials.gov: NCT03624361. RESULTS: At the 6-month follow-up, the primary endpoint was fulfilled, with 75.9% of patients reaching prospectively defined success. The mean IOP was reduced by 40.2% (9.9 mm Hg) to 14.7±6.0 mm Hg at 6 months from 24.6±3.8 mm Hg at baseline. The use of IOP-lowering medication ingredients was reduced by 63.4% from 2.9±1.2 at baseline to 1.0±1.3. Furthermore, 79.3% of the patients had mean IOP ≤18 mm Hg, 82.8% achieved a ≥20% IOP reduction, and 55.2% were medication free at 6 months. Six device-related serious adverse events were reported in the study eye: IOP increase (3/31 patients, 9.7%), and single reports of eye pain, corneal erosion, and chorioretinal folds (1/31, 3.2%), all of which resolved. There was minimal change to corneal endothelial cell density. CONCLUSION: Ab-interno supraciliary surgical implantation using MINIject DO627 in a stand-alone procedure significantly lowers IOP by 40% at the 6-month follow-up, while reducing the need for IOP-lowering medication.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Implantação de Prótese/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Segurança de Equipamentos , União Europeia , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Prospectivos , Método Simples-Cego , Fatores de Tempo , Tonometria Ocular , Resultado do Tratamento
9.
Acta Ophthalmol ; 98(6): e768-e772, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32043817

RESUMO

PURPOSE: To evaluate the concentrations of pro-inflammatory cytokines in tear and aqueous humour of patients with primary open-angle glaucoma (POAG), relative to healthy controls. METHOD: Tear and aqueous humour samples were collected from 29 healthy controls and 27 POAG patients. Twenty-seven inflammatory cytokines were analysed: interleukin (IL)-1ß, IL-1ra, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL9, IL-10, IL-12, IL-13, IL-15, IL-17, eotaxin, fibroblast growth factor (FGF) basic, granulocyte colony-stimulating factor, granulocyte-monocyte colony-stimulating factor, interferon (IFN)-γ, interferon gamma-induced protein, monocyte chemo-attractant protein-1, macrophage inflammatory protein (MIP)-1α, MIP-1ß, platelet-derived growth factor, regulated on activation normal T cell expressed and secreted, tumour necrosis factor (TNF)-α and vascular endothelial growth factor (VEGF). RESULTS: In tear samples of glaucoma patients, an increase in IL-4, IL-12, IL-15, FGF-basic and VEGF was observed, as well as a decrease in MIP-1a relative to the control group (p < 0.05). IL-5, IL-12, IL-15, IFN-γ and MIP-1a were significantly higher in aqueous humour of glaucoma eyes (p < 0.05). A poor correlation between cytokine levels in tear and aqueous humour was observed. CONCLUSION: The different profiles of inflammatory marker expression of patients with POAG and healthy controls confirm the inflammatory activity of the pathology, indicating that some of them could be used as potential biomarkers of this disease.


Assuntos
Humor Aquoso/metabolismo , Citocinas/metabolismo , Glaucoma de Ângulo Aberto/metabolismo , Lágrimas/metabolismo , Biomarcadores/metabolismo , Estudos de Casos e Controles , Estudos Transversais , Feminino , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Masculino
10.
Cornea ; 39(1): 88-91, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31414996

RESUMO

PURPOSE: To determine corneal topographic, anatomic, and biomechanical properties in patients newly diagnosed with severe obstructive sleep apnea-hypopnea syndrome (OSAHS). METHODS: This is a cross-sectional study including 25 patients recently diagnosed with severe OSAHS (apnea-hypopnea index above 30) and a paired control group of 25 healthy subjects. All patients underwent a complete eye examination with an elevation topography Pentacam Scheimpflug study and a study with Reichert Ocular Response Analyzer, collecting several topographic, anatomic, and biomechanical variables. RESULTS: Fifty eyes of 25 patients (23 of them were men) diagnosed with OSAHS by somnography and the same number of healthy subjects (23 of them were men) were included, with an average age of 64 ± 11 years (range 45-78 years) for cases and an average age of 64 ± 11 years (range 45-81 years) for the controls. No differences were found in keratometry, cylinder, refractive indexes, Bad-D, or pachymetry. The mean corneal volume for cases was 58.64 ± 3.05 mm and for the controls 60.48 ± 3.33 mm (P = 0.005). The mean minimum radius for cases was 7.49 ± 0.31 and for the controls 7.36 ± 0.30 (P = 0.035). The mean elevation in apex for cases was 8.46 ± 5.18 and for the controls 2.38 ± 2.36 (P ≤ 0.001). Two eyes with a topographic diagnosis of keratoconus (KC) and another 6 with subclinical KC were detected using the Pentacam in the OSAHS group. CONCLUSIONS: Many of the corneal topographic and biomechanical variables in patients with severe OSAHS present different values from the general population with a trend toward KC values, such as keratoconus index or paired keratoconus index. Compared with the control group, significant differences were found in corneal volume, corneal elevation, and minimum radius.


Assuntos
Córnea/patologia , Topografia da Córnea/métodos , Pressão Intraocular/fisiologia , Ceratocone/diagnóstico , Apneia Obstrutiva do Sono/complicações , Idoso , Idoso de 80 Anos ou mais , Córnea/fisiopatologia , Estudos Transversais , Elasticidade , Feminino , Seguimentos , Humanos , Ceratocone/etiologia , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Polissonografia , Prognóstico , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/diagnóstico , Fatores de Tempo
11.
J AAPOS ; 23(2): 94.e1-94.e4, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30951827

RESUMO

PURPOSE: To evaluate retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography (SD-OCT) in a population of children diagnosed with primary congenital glaucoma (PCG). METHODS: In this cross-sectional study, 59 eyes of 59 children diagnosed with PCG and 87 eyes of 87 healthy children were evaluated by SD-OCT to measure the RNFL. The global average peripapillary RNFL thickness and sectional RNFL thickness were evaluated in both groups. Differences in global average and sectional thickness were analyzed. RESULTS: Mean age in the PCG group was 9.61 ± 3.23 years; in the control group, 8.47 ± 2.99 years (P = 0.0516). There were statistically significant differences (P < 0.007) in all sectors between both groups. CONCLUSIONS: SD-OCT is a promising tool for evaluating the eyes of children diagnosed with PCG. Future research should examine the test-retest variability of SD-OCT parameters and their ability to diagnose progression in these children.


Assuntos
Glaucoma/congênito , Doenças do Nervo Óptico/congênito , Estudos de Casos e Controles , Criança , Estudos Transversais , Feminino , Glaucoma/patologia , Humanos , Masculino , Fibras Nervosas/patologia , Nervo Óptico/diagnóstico por imagem , Nervo Óptico/patologia , Doenças do Nervo Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/patologia , Tomografia de Coerência Óptica/métodos
12.
J Pediatr Ophthalmol Strabismus ; 54(6): 387-394, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28850641

RESUMO

PURPOSE: To evaluate the effectiveness of quantifying color changes in the optic nerve head in retinal photographs of patients with childhood glaucoma. METHODS: In this observational study, three photographs of the optic nerve head were obtained in 28 patients with childhood glaucoma and 28 age- and sex-matched healthy participants (the childhood glaucoma and control groups, respectively). The Laguna Optic Nerve Head Hemoglobin (ONhE) software (Insoft SL, Tenerife, Spain) was used to determine hemoglobin levels in the optic nerve head. The following parameters were quantified: the hemoglobin levels in the optic nerve head across the whole disc, in 24 sectors (the optic nerve head divided by two concentric rings and eight 45-degree radial sectors), and in the vertical disc diameter (sectors 8 and 20), and the estimated cup-disc ratio and Glaucoma Discriminant Function, which combines the slope of the hemoglobin amount with the mean vertical disc diameter. RESULTS: Patient ages ranged from 9 to 14 years (median: 11 years) in the childhood glaucoma group, and 7 to 13 years (median: 9 years) in the control group (P < .061). Eyes in the childhood glaucoma group showed a significantly higher cup-disc ratio compared to eyes in the control group (0.6 ± 0.2 vs 0.5 ± 0.1, respectively; P < .0001). In the childhood glaucoma group, the Glaucoma Discriminant Function was found to be significantly lower than in the control group (-6.5 ± 31.1 vs 9.4 ± 17.1, respectively; P < .0001). There were no significant differences in the hemoglobin levels in the optic nerve head across the whole disc between eyes in the childhood glaucoma and control groups (58.2% ± 10.9% vs 58.5% ± 6.7%, respectively; P = .847). The Laguna ONhE software showed good reproducibility in measuring percentages of hemoglobin levels in both groups. CONCLUSIONS: The Laguna ONhE software is useful for patients with childhood glaucoma. However, hemoglobin levels in the optic nerve head across the whole disc may have normal values. This method had good reliability and is easy to implement in routine clinical practice. [J Pediatr Ophthalmol Strabismus. 2017;54(6):387-394.].


Assuntos
Glaucoma/metabolismo , Hemoglobinas/metabolismo , Disco Óptico/metabolismo , Adolescente , Biomarcadores/metabolismo , Criança , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular , Masculino , Microscopia Acústica , Disco Óptico/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica , Campos Visuais
13.
Acta Ophthalmol ; 95(2): e107-e112, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27573413

RESUMO

PURPOSE: To determine whether a set of ocular morphometric and biomechanical variables are able to discriminate between healthy volunteers and patients suffering from primary congenital glaucoma (PCG). METHODS: Case-control study in which 66 patients with PCG and 94 age-matched healthy subjects were evaluated using ocular response analyser (ORA) to record corneal biomechanical properties. Topographic corneal variables were obtained using the Pentacam in both groups. To determine the ability to discern between both groups, a multivariate binary logistic model was constructed. The outcome was the diagnosis of PCG and the predictors; the corneal variables analysed along with their first-term interactions. Sensitivity and specificity of this model along with the area under the receiver characteristic operating curve (AUC of ROC) were determined. RESULTS: The best model to discriminate between both groups included the following predictors: corneal hysteresis (CH), corneal resistance factor (CRF), posterior maximum elevation (PME), anterior maximum elevation (AME) and central corneal thickness (CCT). This model, for a cut-point of 50%, presents a sensitivity of 86.67%, a specificity of 86.89% and an AUC of the ROC curve of 93.16% [95% confidence interval (CI): 88.97-97.35]. The adjusted odds ratios of those predictors which showed a significant discriminating capacity were as follows: for CH, 0.27 (95% confidence interval: 0.15-0.46); for CRF, 2.13 (95% CI: 1.33-3.40); for PME, 1.06 (95% CI: 1.01-1.12); and for AME, 1.35 (95% CI: 1.10-1.66). CONCLUSION: Corneal hysteresis (CH), CRF, PME and AME are able to discern between patients with PCG and healthy controls. This fact suggests that there are structural and biomechanical differences between these groups.


Assuntos
Córnea/patologia , Córnea/fisiopatologia , Topografia da Córnea , Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Pré-Escolar , Elasticidade , Feminino , Glaucoma/congênito , Glaucoma/fisiopatologia , Voluntários Saudáveis , Humanos , Masculino , Estudos Retrospectivos
14.
Adv Ther ; 34(2): 378-395, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28000166

RESUMO

The approval of one of the first anti-vascular endothelial growth factor (VEGF) agents for the treatment of neovascular age-related macular degeneration one decade ago marked the beginning of a new era in the management of several sight-threatening retinal diseases. Since then, emerging evidence has demonstrated the utility of these therapies for the treatment of other ocular conditions characterized by elevated VEGF levels. In this article we review current perspectives on the use of anti-VEGF drugs as adjuvant therapy in the management of neovascular glaucoma (NVG). The use of anti-VEGFs for modifying wound healing in glaucoma filtration surgery (GFS) is also reviewed. Selected studies investigating the use of anti-VEGF agents or antimetabolites in GFS or the management of NVG have demonstrated that these agents can improve surgical outcomes. However, anti-VEGF agents have yet to demonstrate specific advantages over the more established agents commonly used today. Further studies are needed to evaluate the duration of action, dosing intervals, and toxicity profile of these treatments.


Assuntos
Bevacizumab/farmacologia , Glaucoma Neovascular/tratamento farmacológico , Ranibizumab/farmacologia , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Inibidores da Angiogênese/farmacologia , Quimioterapia Adjuvante/métodos , Humanos , Resultado do Tratamento
15.
Acta Ophthalmol ; 94(5): e293-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26647905

RESUMO

PURPOSE: To measure the differences in corneal hysteresis (CH) and corneal resistance factor (CRF) in primary congenital glaucoma (PCG) and in control subjects using ocular response analyser (ORA) and also to compare intraocular pressure (IOP) measurements given by ORA against IOP given by Perkins tonometer, a handheld version of Goldman applanation tonometer (GAT), to determine correlation. METHODS: One hundred and eighteen eyes of 78 patients with PCG (group I) and 103 eyes of 53 controls (group II) were evaluated using ORA. In all participants, IOP was measured using the Perkins tonometer. The ORA device uses applanation pressure peaks to generate the corneal-compensated IOP (IOPcc), which is reportedly independent of corneal thickness, and the measurement of Goldman-correlated IOP (IOPg), which is influenced by corneal thickness. RESULTS: The measures in group I were as follows: IOPcc 20.92 ± 5.33; IOPg 18.87 ± 6.67; CH 8.51 ± 2.25; CRF 9.85 ± 3.03; and IOP measured by Goldman 18.32 ± 5.13. The measures in group II were as follows: IOPcc 14.33 ± 2.91; IOPg 14.77 ± 3.00; CH 11.37 ± 1.61; CRF 11.02 ± 1.74; and IOP measured by Goldman 13.74 ± 2.42. The differences of all parameters compared between both groups were statistically significant (p < 0.001 for CH and for all IOP measures and p = 0.001 for CRF). The values of IOPcc, IOPg and IOP measured with Goldman were higher in group I than the values in group II. However, CH and CRF values were lower in group I. CONCLUSION: A decrease in CH and CRF has been observed in patients with PCG compared to controls. Future research should assess how these parameters are modified in PCG and whether they could provide more information about progression.


Assuntos
Córnea/fisiologia , Elasticidade/fisiologia , Hidroftalmia/fisiopatologia , Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Adolescente , Adulto , Fenômenos Biomecânicos , Criança , Pré-Escolar , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS