Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Clin Immunol ; 265: 110295, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38914359

RESUMO

Assessing T-cell independent antibody response to polysaccharide vaccines is crucial for diagnosing humoral immune deficiencies. However, immunocompetence criteria based on S. pneumoniae vaccination remain unclear. We evaluated IgG antibody vaccine response in healthy individuals to establish interpretive criteria. Pre- and 4-week post-vaccination sera were collected from 79 adults. Antibody concentrations to PNEUMOVAX 23 serotypes were measured using a multiplexed platform. Immunocompetence was determined by fold increase in post-vaccination response, percentage of serotypes achieving 4- or 2-fold antibody ratio, and post-vaccination concentration ≥ 1.3 µg/mL. Immunogenicity varied widely across the 23 serotypes (26.6% to 94.9% for ≥4-fold increase, 51.9% to 98.7% for ≥2-fold increase). Immunocompetence based on historic criteria of ≥4-fold increase in antibody ratio to ≥70% of serotypes was low (72.2%), but increased to 98.7% with criteria of at least a 2-fold increase and/or post-vaccination concentration ≥ 1.3 µg/mL. Current criteria for assessing immunocompetence may be overly stringent and require updating.

2.
Ann Allergy Asthma Immunol ; 128(1): 61-67.e4, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34391898

RESUMO

BACKGROUND: Testing for common variable immunodeficiency (CVID) requires evaluation of specific antibody responses to vaccines. Current practice of evaluating pneumococcal serotype-specific immunoglobulin (Ig)G levels after Pneumovax (P23) has several limitations and is not accurate for patients already on immunoglobulin replacement. In contrast, the enzyme-linked immunospot (ELISPOT) assay can be interpreted in patients on immunoglobulin replacement as ex vivo measurement of specific antibody-secreting cells (ASCs). OBJECTIVE: To optimize and test an ELISPOT assay to evaluate vaccination response to P23 and compare with P23 serotype-specific IgG for patients on intravenous immunoglobulin (IVIG). METHODS: We prospectively enrolled a total of 15 adults: normal controls (n = 8), patients with CVID on IVIG replacement (n = 2), patients on IVIG replacement for recurrent infections who did not meet diagnostic criteria for CVID, considered IgG deficiency (n = 2), and patients without immunodeficiency on high-dose IVIG for other diagnosis (n = 3). We measured P23 serotype-specific IgG before and 4 weeks after P23 and ELISPOT ASCs before and 1 week after P23 (with B-cell subpopulation analysis by flow cytometry in patients on IVIG). RESULTS: Normal controls had a vaccination response by P23 serotype-specific IgG, whereas patients on IVIG did not. Except for true patients with CVID on IVIG, a P23 ELISPOT ASC response was found in normal controls (highest) and most patients on IVIG for recurrent infections or other diagnosis. CONCLUSION: Our pilot study suggests that an optimized ELISPOT protocol has utility to evaluate the P23-specific antibody response after vaccination. Our ELISPOT assay seemed reliable for patients on IVIG and may help differentiate true patients with CVID from those with a less stringent diagnosis while on IVIG.


Assuntos
Imunodeficiência de Variável Comum , ELISPOT , Imunoglobulinas Intravenosas , Síndromes de Imunodeficiência , Vacinas Pneumocócicas/imunologia , Adulto , Imunodeficiência de Variável Comum/diagnóstico , Humanos , Imunogenicidade da Vacina , Imunoglobulinas Intravenosas/uso terapêutico , Síndromes de Imunodeficiência/diagnóstico , Projetos Piloto , Reinfecção
3.
Cytokine ; 142: 155478, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33667962

RESUMO

Coronavirus disease 2019 (COVID-19) is a rapidly evolving infectious/inflammatory disorder which has turned into a global pandemic. With severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) as its etiologic agent, severe COVID-19 cases usually develop uncontrolled inflammatory responses and cytokine storm-like syndromes. Measuring serum levels of pro-inflammatory cytokines (e.g., IL-6 and others) as inflammatory biomarkers may have several potential applications in the management of COVID-19, including risk assessment, monitoring of disease progression, determination of prognosis, selection of therapy and prediction of response to treatment.This is especially true for pediatric patients with COVID-19 associated Kawasaki-like disease and similar syndromes. In this report, we review the current knowledge of COVID-19 associated cytokines, their roles in host immune and inflammatory responses, the clinical significance and utility of cytokine immunoassays in adult and pediatric COVID-19 patients, as well as the challenges and pitfalls in implementation and interpretation of cytokine immunoassays. Given that cytokines are implicated in different immunological disorders and diseases, it is challenging to interpret the multiplex cytokine data for COVID-19 patients. Also, it should be taken into consideration that biological and technical variables may affect the commutability of cytokine immunoassays and enhance complexity of cytokine immunoassay interpretation. It is recommended that the same method, platform and laboratory should be used when monitoring differences in cytokine levels between groups of individuals or for the same individual over time. It may be important to correlate cytokine profiling data with the SARS-CoV-2 nucleic acid amplification testing and imaging observations to make an accurate interpretation of the inflammatory status and disease progression in COVID-19 patients.


Assuntos
COVID-19 , Síndrome da Liberação de Citocina , Citocinas/imunologia , SARS-CoV-2/imunologia , Adulto , COVID-19/diagnóstico , COVID-19/imunologia , Teste de Ácido Nucleico para COVID-19 , Criança , Síndrome da Liberação de Citocina/diagnóstico , Síndrome da Liberação de Citocina/imunologia , Humanos , Imunoensaio
4.
Eur J Neurol ; 28(5): 1771-1773, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33253468

RESUMO

BACKGROUND AND PURPOSE: Primary autoimmune cerebellar ataxia (PACA) in the absence of another triggering disease represents an emerging category of neurological illness. We report such a case whose ataxia was markedly responsive to plasma exchange. We analyzed patient serum for the presence of IgM or IgG anticerebellar neuronal antibodies. METHODS: Case presentation: rat cerebellar slice cultures incubated with patient sera were studied for IgG and IgM antibody uptake, intracellular binding, and neuronal death. Patient serum was evaluated for anti-myelin associated glycoprotein (anti-MAG) and associated anti-glycolipid antibodies. RESULTS: Antibodies were taken up by viable cerebellar neurons and bound to intracellular antigens. Uptake and predominantly nuclear binding of IgG were seen in granule cells whereas cytoplasmic binding of IgM was observed predominantly in Purkinje cells. Intracellular antibody accumulation was not accompanied by neuronal death, consistent with the patient's excellent clinical response to plasma exchange. Anti-MAG or other associated anti-glycolipid antibodies were not detected. CONCLUSIONS: PACA may be associated with both IgG and IgM antibodies reactive with cerebellar neuronal antigens. Our patient's response to plasma exchange supports a role for antineuronal antibodies in disease pathogenesis and emphasizes the need for rapid diagnosis and treatment.


Assuntos
Ataxia Cerebelar , Autoanticorpos , Humanos , Imunoglobulina G , Imunoglobulina M , Glicoproteína Associada a Mielina , Células de Purkinje/metabolismo
5.
Clin Chem Lab Med ; 58(9): 1489-1497, 2020 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-32271157

RESUMO

Background: The indirect immunofluorescence assay (IFA) using HEp-2 cell substrates is the preferred method by some for detecting antinuclear antibodies (ANA) as it demonstrates a number of characteristic staining patterns that reflect the cellular components bound as well as semi-quantitative results. Lack of harmonized nomenclature for HEp-2 IFA patterns, subjectivity in interpretation and variability in the number of patterns reported by different laboratories pose significant harmonization challenges. The main objectives of this study were to assess current practice in laboratory assessment of HEp-2 IFA, identify gaps and define strategies to improve reading, interpretation and reporting. Methods: We developed and administered a 24-item survey based on four domains: educational and professional background of participants, current practice of HEp-2 IFA testing and training, gap assessment and the perceived value of International Consensus on Antinuclear Antibody Patterns (ICAP) and other factors in HEp-2 IFA assessment. The Association of Medical Laboratory Immunologists (AMLI) and American Society for Clinical Pathology administered the survey from April 1 to June 30, 2018, to members involved in ANA testing. This report summarizes the survey results and discussion from a dry workshop held during the 2019 AMLI annual meeting. Results: One hundred and seventy-nine (n = 179) responses were obtained where a significant number were clinical laboratory scientists (46%), laboratory directors (24%), supervisors (13%) or others (17%). A majority of respondents agreed on the need to standardize nomenclature and reporting of HEp-2 IFA results. About 55% were aware of the ICAP initiative; however, among those aware, a significant majority thought its guidance on HEp-2 IFA nomenclature and reporting is of value to clinical laboratories. To improve ICAP awareness and further enhance HEp-2 IFA assessment, increased collaboration between ICAP and the clinical laboratory community was suggested with emphasis on education and availability of reference materials. Conclusions: Based on these suggestions, future efforts to optimize HEp-2 IFA reading, interpretation and reporting would benefit from more hands-on training of laboratory personnel as well as continuous collaboration between professional organizations, in vitro diagnostic manufacturers and clinical laboratories.


Assuntos
Anticorpos Antinucleares/sangue , Doenças Autoimunes/diagnóstico , Técnica Indireta de Fluorescência para Anticorpo/métodos , Técnica Indireta de Fluorescência para Anticorpo/normas , Laboratórios/normas , Humanos , Inquéritos e Questionários , Estados Unidos
6.
Clin Immunol ; 150(2): 201-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24440645

RESUMO

Src-like adaptor protein (SLAP) adapts c-Cbl, an E3 ubiquitin ligase, to activated components of the BCR signaling complex regulating BCR levels and signaling in developing B cells. Based on this function, we asked whether SLAP deficiency could decrease the threshold for tolerance and eliminate development of autoreactive B cells in two models of autoantibody production. First, we sensitized mice with a dsDNA mimetope that causes an anti-dsDNA response. Despite equivalent production of anti-peptide antibodies compared to BALB/c controls, SLAP(-/-) mice did not produce anti-dsDNA. Second, we used the 56R tolerance model. SLAP(-/-) 56R mice had decreased levels of dsDNA-reactive antibodies compared to 56R mice due to skewed light chain usage. Thus, SLAP is a critical regulator of B-cell development and function and its deficiency leads to decreased autoreactive B cells that are otherwise maintained by inefficient receptor editing or failed negative selection.


Assuntos
Anticorpos Antinucleares/biossíntese , DNA/imunologia , Proteínas Proto-Oncogênicas pp60(c-src)/deficiência , Animais , Anticorpos Antinucleares/imunologia , Subpopulações de Linfócitos B/imunologia , Subpopulações de Linfócitos B/metabolismo , Feminino , Cadeias Pesadas de Imunoglobulinas/imunologia , Cadeias Pesadas de Imunoglobulinas/metabolismo , Cadeias kappa de Imunoglobulina/imunologia , Cadeias kappa de Imunoglobulina/metabolismo , Cadeias lambda de Imunoglobulina/imunologia , Cadeias lambda de Imunoglobulina/metabolismo , Camundongos , Camundongos Knockout , Proteínas Proto-Oncogênicas pp60(c-src)/genética , Receptores de Antígenos de Linfócitos B/metabolismo
7.
J Immunol Methods ; 529: 113681, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38701879

RESUMO

Cerebrospinal fluid (CSF) is a critical body fluid to examine in attempts to discover potential biomarkers for neuroinflammatory and other disorders of the central nervous system (CNS). Serum and/or plasma cytokine levels have been associated with a variety of inflammatory conditions, and some have been shown to be actionable therapeutic targets. Less is known, however, about cytokine levels in CSF. Serum and plasma cytokine testing is widely available in clinical and research laboratories, but cytokine testing in CSF is extremely limited and if performed, accompanied by a disclaimer that it is an unvalidated specimen type. In this study, we validate CSF as a suitable specimen type and determine normal reference intervals for multiple cytokines as well as a soluble cytokine receptor. CSF was validated as a specimen type for testing using a laboratory developed multiplexed cytokine assay previously validated to measure 13 cytokines/markers in serum and plasma. Performance parameters including specimen dilution, specimen interference, linearity and precision were examined. Reference intervals were established using 197 normal and control CSF specimens by non-parametric quantile-based methods. CSF cytokine analysis demonstrated within and between run precision of <10% and < 20% CV, respectively and linearity of ±15% for all analytes throughout the analytical measurement range of the assay. Reference intervals for the 13 cytokines/markers were established from 197 normal and control CSF specimens (78 Male; mean 44.8 y ± 21.7 SD, 119 Female; mean 42.8 y ± 20.3 SD). Cytokine concentrations in CSF from normal donors and controls were less than the lower limit of quantitation of our assay for 6 of the 13 measured cytokines/markers. The chemokine IL8 demonstrated the highest concentration of all analytes measured. CSF demonstrated acceptable performance as a specimen type in our multiplexed cytokine assay. By validating CSF as a specimen type and establishing normal reference intervals for cytokine concentrations in CSF, their potential as biomarkers for infectious, autoimmune and other inflammatory CNS disorders can be more appropriately investigated.


Assuntos
Biomarcadores , Citocinas , Humanos , Citocinas/líquido cefalorraquidiano , Citocinas/sangue , Valores de Referência , Feminino , Masculino , Adulto , Biomarcadores/líquido cefalorraquidiano , Biomarcadores/sangue , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Reprodutibilidade dos Testes , Adolescente
8.
J Immunol Methods ; 526: 113627, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38311009

RESUMO

OBJECTIVES: To compare 3 different methods for the detection of antibodies against muscle-specific kinase (MuSK). METHODS: MuSK antibody testing was performed in 237 serum samples by enzyme-linked immunosorbent assay (ELISA) and fixed cell-based assay (f-CBA-IFA). One hundred and forty-eight (148) of the sera had previously been tested by RIA during clinical testing: 47 MuSK antibody positive and 101 MuSK antibody negative. Of the MuSK RIA negative antibodies, 46 tested positive for other neural antibodies. Additionally, 89 sera were subsequently tested by all three methods: 70 healthy controls and 19 sera positive for other neural antibodies. RESULTS: Qualitative inter-assay agreement based on tiered RIA values was 100% for results of 1.00 nmol/L or greater by both methods; 81% and 94% for results between 0.21 and 0.99 nmol/L by ELISA and f-CBA-IFA, respectively; and 0% for results of 0.04-0.20 nmol/L by both methods. Negative results showed 100% agreement between RIA and both ELISA and f-CBA-IFA (n = 55). None of the controls positive for other neural autoantibodies or healthy controls were positive in any assay. CONCLUSION: Overall, excellent agreement was observed between the 3 methods used to detect antibodies against MuSK. Both the f-CBA-IFA and ELISA performed comparably to RIA and exhibited excellent overall accuracy for MuSK IgG detection, with the f-CBA-IFA demonstrating higher agreement between positive samples with the RIA than the ELISA without identifying false positives in the control samples. Advantages of non-radioactive methods for the detection of MuSK antibodies include reduced handling and disposal of hazardous materials, potential for automation and the reagents having a longer shelf-life, reducing costs associated with both workflow and lot validations. Thus, commercially available ELISA and transfected cell-based assays are viable alternatives to the traditional radioactive assay used for serologic determination of MuSK IgG.


Assuntos
Miastenia Gravis , Humanos , Receptores Colinérgicos , Receptores Proteína Tirosina Quinases , Autoanticorpos , Ensaio de Imunoadsorção Enzimática , Anticorpos Monoclonais Humanizados , Imunoglobulina G , Músculos
9.
J Immunol ; 186(4): 2273-81, 2011 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-21248251

RESUMO

To test if manipulating TCR complex-mediated signaling (TCR signaling) could treat autoimmune disease, we generated the double SKG Src-like adapter protein (SLAP) knockout (DSSKO) mouse model. The SKG mutation in ZAP70 and SLAP have opposing functions on the regulation of TCR signaling. The combination of these two mutations alters TCR signaling in the context of a defined genetic background, uniform environmental conditions, and a well-characterized signaling disruption. In contrast to SKG mice, DSSKO mice do not develop zymosan-induced chronic autoimmune arthritis. This arthritis prevention is not due to significant alterations in thymocyte development or repertoire selection but instead enhanced numbers of regulatory T cells (Tregs) and decreased numbers of Th17 cells skewing the ratio of Tregs to autoreactive effector T cells. Treg depletion and/or functional blockade led to the development of arthritis in DSSKO mice. In vitro suppression of effector T cell proliferation was also enhanced, demonstrating that DSSKO mice have increased numbers of Tregs with increased function. Understanding how TCR signals influence development, expansion, and function of Tregs in DSSKO mice could advance our ability to manipulate Treg biology to treat ultimately autoimmune disease.


Assuntos
Artrite Experimental/prevenção & controle , Doenças Autoimunes/prevenção & controle , Proteínas Proto-Oncogênicas pp60(c-src)/deficiência , Linfócitos T Reguladores/imunologia , Linfócitos T Reguladores/patologia , Regulação para Cima/genética , Regulação para Cima/imunologia , Animais , Artrite Experimental/genética , Artrite Experimental/imunologia , Doenças Autoimunes/genética , Doenças Autoimunes/imunologia , Doença Crônica , Modelos Animais de Doenças , Contagem de Linfócitos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Knockout , Camundongos Transgênicos , Proteínas Proto-Oncogênicas pp60(c-src)/genética , Proteína-Tirosina Quinase ZAP-70/genética
10.
Arch Pathol Lab Med ; 147(12): 1461-1465, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36897998

RESUMO

CONTEXT.­: Antibodies to U1 ribonucleoprotein (U1RNP) were first described more than 50 years ago, and although clinically relevant for antinuclear antibody-associated connective tissue disease (ANA-CTD), test results are challenging to interpret. OBJECTIVE.­: To evaluate the impact of anti-U1RNP analyte diversity in the assessment of patients at risk for ANA-CTD. DESIGN.­: Two multiplex assays for U1RNP (Smith [Sm]/RNP and RNP68/A) were used to test serum specimens from consecutive patients (n = 498) under evaluation for CTD in a single academic center. Discrepant specimens were further tested for Sm/RNP antibody by enzyme-linked immunosorbent assay and the BioPlex multiplex assay. Data were evaluated for antibody positivity per analyte and their method of detection, correlations between analytes, and impact on clinical diagnoses through retrospective chart review. RESULTS.­: Of the 498 patients tested, 47 (9.4%) were positive in the RNP68/A (BioPlex) and 15 (3.0%) were positive in the Sm/RNP (Theradiag) immunoassays. U1RNP-CTD, other ANA-CTD, and no ANA-CTD were diagnosed in 34% (16 of 47), 12.8% (6 of 47), and 53.2% (25 of 47) of the cases, respectively. The prevalence of antibody by method in patients with U1RNP-CTD was 100.0% (16 of 16), 85.7% (12 of 14), 81.5% (13 of 16), and 87.5% (14 of 16) for RNP68/A, Sm/RNP BioPlex, Sm/RNP Theradiag, and Sm/RNP Inova, respectively. For other ANA-CTD and no ANA-CTD, the highest prevalence was observed with RNP68/A; all others had comparable performance. CONCLUSIONS.­: In this study, the overall performance characteristics of Sm/RNP antibody assays were comparable; however, the RNP68/A immunoassay was very sensitive but less specific. In the absence of harmonization, reporting the type of U1RNP analyte in clinical testing may be useful in guiding interpretation and interassay correlations.


Assuntos
Anticorpos Antinucleares , Doenças do Tecido Conjuntivo , Humanos , Relevância Clínica , Estudos Retrospectivos , Ensaio de Imunoadsorção Enzimática , Doenças do Tecido Conjuntivo/diagnóstico , Ribonucleoproteínas
11.
Front Neurol ; 14: 1192644, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37503513

RESUMO

Introduction: As recognition of myelin oligodendrocyte glycoprotein (MOG) antibody-associated disease becomes more widespread, the importance of appropriately ordering and interpreting diagnostic testing for this antibody increases. Several assays are commercially available for MOG testing, and based on a few small studies with very few discrepant results, some have suggested that live cell-based assays (CBA) are superior to fixed CBA for clinical MOG antibody testing. We aimed to determine the real-world agreement between a fixed and live CBA for MOG using two of the most commonly available commercial testing platforms. Methods: We compared paired clinical samples tested at two national clinical reference laboratories and determined the real-world agreement between the fixed CBA and live CBA. Results: Of 322 paired samples tested on both platforms, 53 were positive and 246 were negative by both methodologies (agreement 92.9%, Cohen's kappa 0.78, [0.69-0.86]). Spearman correlation coefficient was 0.80 (p < 0.0001). Of the discrepant results, only 1 of 14 results positive by the live CBA had a titer greater than 1:100, and only 1 of 9 results positive by the fixed CBA had a titer of greater than 1:80. Lower titers on the fixed CBA correlate to higher titers on the live CBA. Conclusion: Overall, there is excellent agreement between fixed and live CBA for MOG antibody testing in a real-world clinical laboratory setting. Clinicians should be aware of which method they use to assess any given patient, as titers are comparable, but not identical between the assays.

12.
J Immunol Methods ; 510: 113350, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36067869

RESUMO

Diagnostic vaccination is an integral component in the evaluation of patients suspected to have a B cell or humoral deficiency. Evaluation of antibody production in response to both protein- and polysaccharide-based vaccines aids in distinguishing between specific categories of humoral deficiency. Although assessment of pneumococcal polysaccharide responses is widely available and included in diagnostic guidelines, significant variability still exists in the measurement and interpretation of these responses. Interpretation can also be complicated by age, vaccination history and treatment with immunoglobulin replacement therapy. Despite the challenges and limitations of evaluating pneumococcal polysaccharide vaccine responses, it can provide valuable diagnostic and prognostic information to guide therapeutic intervention. Future efforts are needed to further standardize measurement and interpretation of pneumococcal antibody responses to vaccination and to identify and establish other methods and/or vaccines as alternatives to pneumococcal vaccination to address the challenges in certain patient populations.


Assuntos
Síndromes de Imunodeficiência , Polissacarídeos Bacterianos , Anticorpos Antibacterianos , Humanos , Imunoglobulina G , Síndromes de Imunodeficiência/diagnóstico , Vacinas Pneumocócicas/uso terapêutico , Streptococcus pneumoniae , Vacinação
13.
Autoimmun Rev ; 21(6): 103100, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35452854

RESUMO

OBJECTIVE: To determine the impact of myeloperoxidase (MPO) and proteinase 3 (PR3) antigen-specific immunoassays in the stratification of patients at-risk for anti-neutrophil cytoplasmic antibodies (ANCA)-associated vasculitides (AAV) at diagnosis. METHODS: A Medline search was conducted to identify diagnostic accuracy studies using PR3-ANCA or MPO-ANCA for the evaluation of granulomatosis with polyangiitis (GPA), microscopic polyangiitis (MPA), and eosinophilic granulomatosis with polyangiitis (EGPA). Studies estimates were pooled using the bivariate method. RESULTS: Diagnostic accuracy varied by analyte and AAV subtype. PR3-ANCA had greater sensitivity than MPO-ANCA for GPA (74% vs 11%, p < 0.001) and MPO-ANCA greater sensitivity for MPA (73% vs 7%, p < 0.001). Specificities of both MPO-ANCA and PR3-ANCA were consistently high (mean 97%, range: 93-99%) for both AAV subtypes. There was insufficient data to perform meta-analysis for the diagnostic accuracy of EPGA. CONCLUSION: These results validate the use of high quality MPO-ANCA and PR3-ANCA immunoassays to screen patients at-risk for AAV as well as to categorize disease as GPA or MPA subtype. However, caution must be exercised in doing so, since some assays may not have optimal performance. Each laboratory should validate appropriate algorithms based on the tests used and testing population.


Assuntos
Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos , Síndrome de Churg-Strauss , Granulomatose com Poliangiite , Poliangiite Microscópica , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/diagnóstico , Anticorpos Anticitoplasma de Neutrófilos , Síndrome de Churg-Strauss/diagnóstico , Granulomatose com Poliangiite/diagnóstico , Humanos , Imunoensaio , Mieloblastina , Peroxidase
14.
J Immunol Methods ; 496: 113102, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34298066

RESUMO

BACKGROUND: In this study, we assessed the performance characteristics of a laboratory-developed radioimmunoassay (RIA) to detect N-type voltage-gated calcium channel (N-VGCC) antibodies found in several autoimmune neurologic diseases. METHODS: Four hundred and forty-five (n = 445) sera were evaluated, including 156 sera (50 positive and 106 negative for N-VGCC antibodies) previously tested at Mayo Clinic Laboratories (MCL) and 289 controls (n = 187 disease and n = 102 healthy). Specimens were analyzed with the RIA using N-VGCC labeled with 125I-ω-conotoxin GVIA. The RIA was compared to the predicate MCL assay using a tiered positive predictive value (PPV) approach. Other performance characteristics evaluated included specificity, precision, interference, and stability. RESULTS: Qualitative inter-laboratory agreement based on tiered PPVs was 100% for results >1.00 nmol/L (71% PPV), 48% for results of 0.10-0.99 nmol/L (24% PPV) and 22% for results of 0.04-0.10 nmol/L (19% PPV). Negative results showed 90% agreement (n = 106). Specificity in controls positive for other neural autoantibodies and healthy controls were 87% and 100%, respectively. Acceptable results were observed for other performance characteristics. CONCLUSIONS: Inter-laboratory correlations demonstrate equivalence between assays with some discrepancies between low positive results. Collaborative efforts aimed at assessing the clinical spectrum associated with these antibodies and consensus for harmonizing test performance are required for optimal categorization of patients.


Assuntos
Autoanticorpos/sangue , Autoimunidade , Canais de Cálcio Tipo N/imunologia , Síndrome Miastênica de Lambert-Eaton/diagnóstico , Radioimunoensaio , Testes Sorológicos , Adulto , Idoso , Especificidade de Anticorpos , Biomarcadores/sangue , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Síndrome Miastênica de Lambert-Eaton/sangue , Síndrome Miastênica de Lambert-Eaton/imunologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
15.
Auto Immun Highlights ; 12(1): 4, 2021 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-33640027

RESUMO

BACKGROUND: To evaluate the interpretation and reporting of antinuclear antibodies (ANA) by indirect immunofluorescence assay (IFA) using HEp-2 substrates based on common practice and guidance by the International Consensus on ANA patterns (ICAP). METHOD: Participants included two groups [16 clinical laboratories (CL) and 8 in vitro diagnostic manufacturers (IVD)] recruited via an email sent to the Association of Medical Laboratory Immunologists (AMLI) membership. Twelve (n = 12) pre-qualified specimens were distributed to participants for testing, interpretation and reporting HEp-2 IFA. Results obtained were analyzed for accuracy with the intended and consensus response for three main categorical patterns (nuclear, cytoplasmic and mitotic), common patterns and ICAP report nomenclatures. The distributions of antibody titers of specimens were also compared. RESULTS: Laboratories differed in the categorical patterns reported; 8 reporting all patterns, 3 reporting only nuclear patterns and 5 reporting nuclear patterns with various combinations of other patterns. For all participants, accuracy with the intended response for the categorical nuclear pattern was excellent at 99% [95% confidence interval (CI): 97-100%] compared to 78% [95% CI 67-88%] for the cytoplasmic, and 93% [95% CI 86%-100%] for mitotic patterns. The accuracy was 13% greater for the common nomenclature [87%, 95% CI 82-90%] compared to the ICAP nomenclature [74%, 95% CI 68-79%] for all participants. Participants reporting all three main categories demonstrated better performances compared to those reporting 2 or less categorical patterns. The average accuracies varied between participant groups, however, with the lowest and most variable performances for cytoplasmic pattern specimens. The reported titers for all specimens varied, with the least variability for nuclear patterns and most titer variability associated with cytoplasmic patterns. CONCLUSIONS: Our study demonstrated significant accuracy for all participants in identifying the categorical nuclear staining as well as traditional pattern assignments for nuclear patterns. However, there was less consistency in reporting cytoplasmic and mitotic patterns, with implications for assigning competencies and training for clinical laboratory personnel.

16.
Mult Scler Int ; 2021: 8692328, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34621549

RESUMO

OBJECTIVE: Aquaporin-4 (AQP4) serum autoantibodies are detected by a variety of methods. The highest sensitivity is achieved with cell-based assays, but the enzyme-linked immunosorbent assay (ELISA) is still commonly utilized by clinicians worldwide. METHODS: We performed a retrospective review to identify all patients at the University of Utah who had AQP4 ELISA testing at ARUP Laboratories from 2010 to 2017. We then reviewed their diagnostic evaluation and final diagnosis based on the ELISA titer result. RESULTS: A total of 750 tests for the AQP4 ELISA were analyzed, and 47 unique patients with positive titers were identified. Less than half of these patients (49%) met the clinical criteria for neuromyelitis optica spectrum disorder (NMOSD). In cases of low positive titers (3.0-7.9 U/mL, n = 19), the most common final diagnosis was multiple sclerosis (52.6%). In the moderate positive cohort (8.0-79.9 U/mL, n = 14), only a little more than half the cohort (64.3%) had NMOSD. In cases with high positives (80-160 U/mL, n = 14), 100% of patients met clinical criteria for NMOSD. CONCLUSIONS: Our data illustrates diagnostic uncertainty associated with the AQP4 ELISA, an assay that is still commonly ordered by clinicians despite the availability of more sensitive and specific tests to detect AQP4 autoantibodies in patients suspected of having NMOSD. In particular, low positive titer AQP4 ELISA results are particularly nonspecific for the diagnosis of NMOSD. The importance of accessibility to both sensitive and specific AQP4 testing cannot be overemphasized in clinical practice.

17.
J Immunol Methods ; 492: 112994, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33626382

RESUMO

The annual meeting of the Association of Medical Laboratory Immunologists (AMLI) was convened virtually over the month of August. Prior to the emergence of the COVID-19 pandemic, AMLI's scientific committee had chosen the following topics as the focus of its 2020 meeting: Histocompatibility Testing and Transplant Immunology; Secondary Immunodeficiency and Immunotherapy Monitoring; ANA Update; and Emerging Infectious Diseases and New Algorithms for Testing. Given the central role of the discipline in the evaluation of the host response to infection, it was apt to add a separate session on antibody testing for SARS-CoV-2 infections to the original program. The current report provides an overview of the subjects discussed in the course of this meeting.


Assuntos
Alergia e Imunologia , COVID-19/imunologia , Imunoterapia/métodos , SARS-CoV-2/fisiologia , Sociedades Médicas , Algoritmos , Animais , Processos Grupais , Teste de Histocompatibilidade , Interações Hospedeiro-Patógeno , Humanos , Laboratórios , Pandemias , SARS-CoV-2/química , Imunologia de Transplantes , Realidade Virtual
18.
PLoS One ; 14(2): e0210675, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30730971

RESUMO

The role of extracellular vesicles (EVs), specifically exosomes, in intercellular communication likely plays a key role in placental orchestration of pregnancy and maternal immune sensing of the fetus. While murine models are powerful tools to study pregnancy and maternal-fetal immune interactions, in contrast to human placental exosomes, the content of murine placental and pregnancy exosomes remains largely understudied. Using a recently developed in vitro culture technique, murine trophoblast stem cells derived from B6 mice were differentiated into syncytial-like cells. EVs from the conditioned media, as well as from pregnant and non-pregnant sera, were enriched for exosomes. The RNA composition of these murine trophoblast-derived and pregnancy-associated exosome-enriched-EVs (ExoE-EVs) was determined using RNA-sequencing analysis and expression levels confirmed by qRT-PCR. Differentially abundant miRNAs were detected in syncytial differentiated ExoE-EVs, particularly from the X chromosome cluster (mmu-miR-322-3p, mmu-miR-322-5p, mmu-miR-503-5p, mmu-miR-542-3p, and mmu-miR-450a-5p). These were confirmed to be increased in pregnant mouse sera ExoE-EVs by qRT-PCR analysis. Interestingly, fifteen miRNAs were only present within the pregnancy-derived ExoE-EVs compared to non-pregnant controls. Mmu-miR-292-3p and mmu-miR-183-5p were noted to be some of the most abundant miRNAs in syncytial ExoE-EVs and were also present at higher levels in pregnant versus non-pregnant sera ExoE-EVs. The bioinformatics tool, MultiMir, was employed to query publicly available databases of predicted miRNA-target interactions. This analysis reveals that the X-chromosome miRNAs are predicted to target ubiquitin-mediated proteolysis and intracellular signaling pathways. Knowing the cargo of placental and pregnancy-specific ExoE-EVs as well as the predicted biological targets informs studies using murine models to examine not only maternal-fetal immune interactions but also the physiologic consequences of placental-maternal communication.


Assuntos
Exoma , Vesículas Extracelulares/metabolismo , MicroRNAs/metabolismo , Gravidez/fisiologia , Trofoblastos/metabolismo , Animais , Vesículas Extracelulares/imunologia , Feminino , Camundongos , MicroRNAs/imunologia , Trofoblastos/imunologia
19.
Cytometry B Clin Cytom ; 96(4): 266-274, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31173473

RESUMO

BACKGROUND: Mass cytometry can differentiate more channels than conventional flow cytometry. However, for clinical use, standardization and agreement with well-established methods is paramount. We compared mass cytometry to standard clinical flow cytometry. METHODS: Mass and flow cytometry were performed in parallel on peripheral blood samples from 25 healthy individuals. Antibody staining was performed on the same samples at the same time, and analyzed for granulocyte, monocyte, lymphocyte, T, B, NK, CD4 and CD8 percentages. Validation parameters included comparison to flow cytometry, inter- and intra-assay precision and establishment of reference intervals. RESULTS: There was a positive correlation between mass and flow cytometry for the eight populations studied (R2 between 0.26 and 0.97). Slopes of the best-fit lines varied from 0.50 to 1.21 (fluorescence/mass). No significant differences in variance were found (F-test, P > 0.05). However, paired t-tests were significantly different for four of the eight markers (granulocytes, NK cells, T cells and CD4 cells), resulting in different reference intervals. Signal intensities were correlated for monocytes, lymphocytes, T, CD4 and CD8 cells (R2 = 0.41-0.57). The mass cytometry intra-assay precisions were 0.7-8.5% and inter-assay precisions 1.5-13.8%. CONCLUSION: Mass and flow cytometry evaluations of whole blood for major cell populations correlate with similar precision and signal intensity. However, for clinical use, separate reference interval studies are required. Cell population identification should rely on gating strategies that take advantage of the characteristics offered by each method. © 2019 International Clinical Cytometry Society.


Assuntos
Técnicas de Laboratório Clínico , Citometria de Fluxo , Adolescente , Adulto , Criança , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
20.
Exp Mol Pathol ; 85(1): 28-39, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18486939

RESUMO

B10.S mice have been considered resistant to experimental autoimmune encephalomyelitis, an animal model of multiple sclerosis. However, sensitization with a myelin oligodendrocyte glycoprotein (MOG) peptide, MOG(92-106), induced clinical signs in 30% of mice and central nervous system (CNS) pathology in 93% of mice. Symptomatic mice had more demyelination, inflammation, perivascular cuffing and axonal damage in the CNS compared to asymptomatic mice, but no strong correlations between CNS pathology and clinical score were found. Interestingly, the ratio of B cells to T cells in cellular infiltrates correlated with clinical score. This suggests that the balance between B and T cells contributes to expression of clinical signs.


Assuntos
Linfócitos B/imunologia , Encefalomielite Autoimune Experimental/imunologia , Tolerância Imunológica , Camundongos , Esclerose Múltipla/imunologia , Glicoproteína Associada a Mielina/imunologia , Linfócitos T/imunologia , Animais , Formação de Anticorpos , Axônios/imunologia , Axônios/patologia , Sistema Nervoso Central/imunologia , Sistema Nervoso Central/patologia , Encefalomielite Autoimune Experimental/patologia , Imunoglobulinas/imunologia , Camundongos Endogâmicos , Esclerose Múltipla/patologia , Proteínas da Mielina , Glicoproteína Associada a Mielina/genética , Glicoproteína Mielina-Oligodendrócito
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA