Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Am Heart J ; 270: 13-22, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38253304

RESUMO

BACKGROUND: Safety and feasibility of transcatheter aortic valve replacement (TAVR) without balloon aortic valvuloplasty (BAV) using the SAPIEN 3 balloon-expandable device has been previously demonstrated. The impact on long-term valve hemodynamic performances and outcomes remains however unknown. We evaluate long-term clinical and hemodynamic results according to the implant strategy (direct TAVR vs BAV pre-TAVR) in patients included in the DIRECTAVI randomized trial (NCT02729519). METHODS: Clinical and echocardiographic follow-up until January 2023 was performed for all patients included in the DIRECTAVI trial since 2016 (n = 228). The primary endpoint was incidence of moderate/severe hemodynamic valve deterioration (HVD), according to the Valve Academic Research defined Consortium-3 criteria (increase in mean gradient ≥10 mmHg resulting in a final mean gradient ≥20 mmHg, or new/worsening aortic regurgitation of 1 grade resulting in ≥ moderate aortic regurgitation). RESULTS: Median follow-up was 3.8 (2.2-4.7) years. Mean age at follow-up was 87 ± 6.7 years. No difference in incidence of HVD in the direct implantation group compared to the BAV group was found (incidence of 1.97 per 100 person-years and 1.45 per 100 person-years, respectively, P = 0.6). Prevalence of predicted prothesis-patient mismatch was low (n = 13 [11.4%] in the direct TAVR group vs n = 15 [13.2%] in BAV group) and similar between both groups (P = .7). Major outcomes including death, stroke, hospitalization for heart failure and pacemaker implantation were similar between both groups, (P = .4, P = .7, P = .3, and P = .3 respectively). CONCLUSION: Direct implantation of the balloon-expandable device in TAVR was not associated with an increased risk of moderate/severe HVD or major outcomes up to 6-year follow-up. These results guarantee wide use of direct balloon-expandable valve implantation, when feasible. CLINICAL TRIALS REGISTRATION NUMBER: NCT05140317.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Seguimentos , Insuficiência da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Tempo , Desenho de Prótese , Valvuloplastia com Balão/efeitos adversos
2.
J Interv Cardiol ; 2023: 8907315, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38125031

RESUMO

Objectives: The aim of this postmarket clinical study was to assess the safety and efficacy of the latest generation polymer-free sirolimus-eluting stents (PF-SES) in an all-comers population comparing outcomes in stable coronary artery disease (CAD) versus acute coronary syndrome (ACS) in France. Background: The efficacy and safety of the first-generation PF-SES have already been demonstrated by randomized controlled trials and "all-comers" observational studies. Methods: For this all-comers observational, prospective, multicenter study, 1456 patients were recruited in 22 French centers. The primary endpoint was target lesion revascularization (TLR) rate at 12 months and secondary endpoints included major adverse cardiac events (MACE) and bleeding. Results: 895 patients had stable CAD and 561 had ACS. At 12 months, 2% of patients had a TLR, with similar rates between stable CAD and ACS (1.9% vs 2.2%, p = 0.7). The overall MACE rate was 5.2% with an expected higher rate in patients with ACS as compared to those with stable CAD (7.3% vs 3.9%, p = 0.007). The overall bleeding event rate was 4.5%, with similar rates in stable CAD as compared to ACS patients (3.8% vs 5.6%, p = 0.3). Dual antiplatelet therapy (DAPT) interruptions prior to the recommended duration occurred in 41.7% of patients with no increase in MACE rates as compared to patients who did not prematurely interrupt DAPT (3.9% vs 6.1%, p = 0.073). Conclusions: The latest generation PF-SES is associated with low clinical event rates in these all-comers patients. There was a high rate of prematurely terminated DAPT, without any effect on MACE at 12 months. This trial is registered with NCT03809715.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Stents Farmacológicos , Sirolimo , Humanos , Síndrome Coronariana Aguda/cirurgia , Síndrome Coronariana Aguda/tratamento farmacológico , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/tratamento farmacológico , Stents Farmacológicos/efeitos adversos , Hemorragia/induzido quimicamente , Hospitais , Polímeros , Estudos Prospectivos , Sirolimo/efeitos adversos , Resultado do Tratamento , Terapia Antiplaquetária Dupla
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA