Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Comput Biol Med ; 181: 109062, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39205344

RESUMO

We propose a state-of-the-art deep learning approach for accurate electrocardiogram (ECG) signal analysis, addressing both waveform delineation and beat type classification tasks. For beat type classification, we integrated two novel schemes into the deep learning model, significantly enhancing its performance. The first scheme is an adaptive beat segmentation method that determines the optimal duration for each heartbeat based on RR-intervals, mitigating segmenting errors from conventional fixed-period segmentation. The second scheme incorporates relative heart rate information of the target beat compared to neighboring beats, improving the model's ability to accurately detect premature atrial contractions (PACs) that are easily confused with normal beats due to similar morphology. Extensive evaluations on the PhysioNet QT Database, MIT-BIH Arrhythmia Database, and real-world wearable device data demonstrated the proposed approach's superior capabilities over existing methods in both tasks. The proposed approach achieved sensitivities of 99.81% for normal beats, 99.08% for premature ventricular contractions, and 97.83% for PACs in beat type classification. For waveform delineation, we achieved F1-scores of 0.9842 for non-waveform, 0.9798 for P-waves, 0.9749 for QRS complexes, and 0.9848 for T-waves. It significantly outperforms existing methods in PAC detection while maintaining high performance across both tasks. The integration of aforementioned two schemes into the deep learning model improved the accuracy of normal sinus rhythms and arrhythmia detection.


Assuntos
Aprendizado Profundo , Eletrocardiografia , Frequência Cardíaca , Processamento de Sinais Assistido por Computador , Humanos , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Bases de Dados Factuais , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico
2.
IEEE Trans Biomed Eng ; 71(2): 456-466, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37682653

RESUMO

OBJECTIVE: We propose an efficient approach based on a convolutional denoising autoencoder (CDA) network to reduce motion and noise artifacts (MNA) from corrupted atrial fibrillation (AF) and non-AF photoplethysmography (PPG) data segments so that an accurate PPG-signal-derived heart rate can be obtained. Our method's main innovation is the optimization of the CDA performance for both rhythms using more AF than non-AF data for training the AF-specific CDA model and vice versa for the non-AF CDA network. METHODS: To evaluate this unconventional training scheme, our proposed network was trained and tested on 25-sec PPG data segments from 48 subjects from two different databases-the Pulsewatch dataset and Stanford University's publicly available PPG dataset. In total, our dataset contains 10,773 data segments: 7,001 segments for training and 3,772 independent segments from out-of-sample subjects for testing. RESULTS: Using real-life corrupted PPG segments, our approach significantly reduced the average heart rate root mean square error (RMSE) of the reconstructed PPG segments by 45.74% and 23% compared to the corrupted non-AF and AF data, respectively. Further, our approach exhibited lower RMSE, and higher sensitivity and PPV for detected peaks compared to the reconstructed data produced by the alternative methods. CONCLUSION: These results show the promise of our approach as a reliable denoising method, which should be used prior to AF detection algorithms for an accurate cardiac health monitoring involving wearable devices. SIGNIFICANCE: PPG signals collected from wearables are vulnerable to MNA, which limits their use as a reliable measurement, particularly in uncontrolled real-life environments.


Assuntos
Fibrilação Atrial , Fotopletismografia , Humanos , Fotopletismografia/métodos , Fibrilação Atrial/diagnóstico , Frequência Cardíaca/fisiologia , Monitorização Fisiológica , Movimento (Física) , Algoritmos , Processamento de Sinais Assistido por Computador , Artefatos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA