Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Gerontol Geriatr Med ; 10: 23337214241237119, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38487275

RESUMO

Grab bars facilitate bathing and reduce the risk of falls during bathing. Suction cup handholds and rim-mounted tub rails are an alternative to grab bars. The objective of this study was to determine whether older adults could install handholds and tub rails effectively to support bathing transfers. Participants installed rim-mounted tub rails and suction cup handholds in a simulated bathroom environment. Installation location and mechanical loading performance were evaluated. Participant perceptions during device installation and a bathing transfer were characterized. While 85% of suction cup handholds met loading requirements, more than half of participants installed the suction cup handhold in an unexpected location based on existing guidance documents. No rim-mounted tub rails were successfully installed. Participants were confident that the devices had been installed effectively. Suction cup handholds and rim mounted tub rails are easy to install, but clients may need additional guidance regarding where, and how to install them.

2.
J Clin Monit Comput ; 27(3): 303-11, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23413133

RESUMO

UNLABELLED: Sleep apnea (SA) is a very common disease with serious health consequences, yet is very under-diagnosed, partially because of the high cost and limited accessibility of in-laboratory polysomnography (PSG). The purpose of this work is to introduce a newly developed portable system for the diagnosis of SA at home that is both reliable and easy to use. The system includes personal devices for recording breath sounds and airflow during sleep and diagnostic algorithms to process the recorded data. The data capturing device consists of a wearable face frame with an embedded electronic module featuring a unidirectional microphone, a differential microphone preamplifier, a microcontroller with an onboard differential analogue to digital converter, and a microSD memory card. The device provides continuous data capturing for 8 h. Upon completion of the recording session, the memory card is returned to a location for acoustic analysis. We recruited 49 subjects who used the device independently at home, after which each subject answered a usability questionnaire. Random data samples were selected to measure the signal-to-noise ratio (SNR) as a gauge of hardware functionality. A subset of 11 subjects used the device on 2 different nights and their results were compared to examine diagnostic reproducibility. Independent of those, system's performance was evaluated against PSG in the lab environment in 32 subject. The overall success rate of applying the device in un-attended settings was 94 % and the overall rating for ease-of-use was 'excellent'. Signal examination showed excellent capturing of breath sounds with an average SNR of 31.7 dB. Nine of the 11 (82 %) subjects had equivalent results on both nights, which is consistent with reported inter-night variability. The system showed 96 % correlation with simultaneously performed in-lab PSG. CONCLUSION: Our results suggest excellent usability and performance of this system and provide a strong rationale to further improve it and test its robustness in a larger study.


Assuntos
Monitorização Ambulatorial/instrumentação , Polissonografia/instrumentação , Síndromes da Apneia do Sono/diagnóstico , Acústica , Algoritmos , Diagnóstico por Computador/instrumentação , Diagnóstico por Computador/estatística & dados numéricos , Desenho de Equipamento , Humanos , Monitorização Ambulatorial/estatística & dados numéricos , Polissonografia/estatística & dados numéricos , Reprodutibilidade dos Testes , Sons Respiratórios , Razão Sinal-Ruído
3.
Syst Rev ; 10(1): 316, 2021 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-34930448

RESUMO

BACKGROUND: Whether due to aging, disability, injury, or other circumstances, an increasing number of Canadians experience functional limitations that reduce their ability to participate in activities of daily life. While the built environment has become increasingly accessible, existing Canadian evacuation guidelines lack comprehensive strategies for evacuating individuals with functional limitations from buildings during emergencies. To inform guideline revisions, a map of existing solutions for evacuating such individuals is required. Therefore, this scoping review aims to provide an account of solutions that have been reported to safely evacuate individuals with functional limitations from the built environment. METHODS: We will conduct a scoping review using the Arksey and O'Malley methodological framework. To identify potentially relevant studies, comprehensive searches (from January 2002 onwards) of the CINAHL, Ei Compendex, Inspec, Embase, MEDLINE, KCI, RSCI, SciELO CI, Web of Science Collection, and Scopus databases will be performed. Using a set of inclusion and exclusion criteria, two reviewers will independently (1) classify identified studies as relevant, irrelevant, or maybe relevant by evaluating their titles and abstracts and (2) classify the relevant and maybe relevant studies as included or excluded by evaluating their full-text. From each included study, data on publication information, study purpose, methodological details, evacuation information, and outcomes will be extracted using a set of data extraction items. We will present a numerical summary of the key characteristics of the included studies. For each evacuation activity, reported evacuation solutions will be summarized, and citations provided for functional limitations that are targeted by a given evacuation solution. To inform Canadian evacuation guideline revisions, we will tabulate evacuation activities common to different types of buildings and emergencies. DISCUSSION: To our knowledge, this will be the first scoping review to identify the state and use of solutions for evacuating individuals with functional limitations from the built environment. Identifying solutions that enable all individuals to safely evacuate from different types of buildings will allow us to inform recommendations for the revision of evacuation guidelines in Canada and other jurisdictions. The findings of this scoping review will be published in a peer-reviewed journal, presented at relevant conferences, and made publicly available on the internet. SYSTEMATIC REVIEW REGISTRATION: Open Science Framework: osf.io/jefgy.


Assuntos
Projetos de Pesquisa , Literatura de Revisão como Assunto , Canadá , Humanos
4.
Am J Infect Control ; 47(4): 376-380, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30502113

RESUMO

BACKGROUND: Improving hand hygiene compliance among healthcare professionals is the most effective way to reduce healthcare-acquired infections. Electronic systems developed to increase hand hygiene performance show promise but might not maintain staff participation over time. In this study, we investigated an intermittent deployment strategy to overcome potentially declining participation levels. METHODS: An electronic monitoring system was deployed 3times at 6-month intervals on a musculoskeletal rehabilitation nursing unit in Toronto. Each deployment lasted 4 consecutive weeks. Each wall-mounted soap and hand rub dispenser was outfitted with an activation counter to assess the impact of system deployments on overall handwashing activity. RESULTS: System deployments took place in October 2016, April 2017, and October 2017. A total of 76,130 opportunities were recorded, with an aggregate hand hygiene performance of 67.43%. A total of 515,156 dispenser activations were recorded. There was a significant increase in aggregate dispenser use with every deployment and a decrease over several weeks following each withdrawal. Participation was high at the beginning of each deployment and declined during each deployment but was restored to a high level with the start of the next deployment. CONCLUSIONS: Intermittent deployment of an electronic monitoring intervention counteracts potential declines in participation rates sometimes seen with continuous system use. However, adoption of this strategy requires the acceptance of lower periods of performance between each deployment.


Assuntos
Técnicas de Observação do Comportamento/métodos , Terapia Comportamental/métodos , Infecção Hospitalar/prevenção & controle , Eletrônica Médica/métodos , Higiene das Mãos/métodos , Pessoal de Saúde , Controle de Infecções/métodos , Canadá , Fidelidade a Diretrizes/estatística & dados numéricos , Humanos
5.
Am J Infect Control ; 47(1): 38-44, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30195406

RESUMO

BACKGROUND: Hand hygiene (HH) compliance in health care is usually measured against versions of the World Health Organization's "Your 5 Moments" guidelines using direct observation. Such techniques result in small samples that are influenced by the presence of an observer. This study demonstrates that continuous electronic monitoring of individuals can overcome these limitations. METHODS: An electronic real-time prompting system collected HH data on a musculoskeletal rehabilitation unit for 12 weeks between October 2016 and October 2017. Aggregate and professional group scores and the distributions of individuals' performance within groups were analyzed. Soiled utility room exits were monitored and compared with performance at patient rooms. Duration of patient room visits and the number of consecutive missed opportunities were calculated. RESULTS: Overall, 76,130 patient room and 1,448 soiled utility room HH opportunities were recorded from 98 health care professionals. Aggregate unit performance for patient and soiled utility rooms were both 67%, although individual compliance varied greatly. The number of hand wash events that occurred while inside patient rooms increased with longer visits, whereas HH performance at patient room exit decreased. Eighty-three percent of missed HH opportunities occurred as part of a series of missed events, not in isolation. CONCLUSIONS: Continuous collection of HH data that includes temporal, spatial, and personnel details provides information on actual HH practices, whereas direct observation or dispenser counts show only aggregate trends.


Assuntos
Coleta de Dados , Equipamentos e Provisões Elétricas , Fidelidade a Diretrizes , Higiene das Mãos/métodos , Instalações de Saúde , Controle de Infecções/métodos , Estudos Transversais , Humanos
6.
Am J Infect Control ; 46(7): 768-774, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29502882

RESUMO

BACKGROUND: Poor hand hygiene by health care workers is a major cause of nosocomial infections. This research evaluated the ability of an electronic monitoring system with real-time prompting capability to change hand hygiene behaviors. METHODS: Handwashing activity was measured by counting dispenser activations on a single nursing unit before, during, and after installation of the system. The effect of changing the prompt duration on hand hygiene performance was determined by a cluster-randomized trial on 3 nursing units with 1 acting as control. Sustainability of performance and participation was observed on 4 nursing units over a year. All staff were eligible to participate. RESULTS: Between June 2015 and December 2016, a total of 459,376 hand hygiene opportunities and 330,740 handwashing events from 511 staff members were recorded. Dispenser activation counts were significantly influenced by use of the system (χ2[3] = 75.76; P < .0001). Hand hygiene performance dropped from 62.61% to 24.94% (odds ratio, 0.36; 95% confidence interval, 0.34-0.38) when the prompting feature was removed. Staff participation had a negative trajectory of -0.72% (P < .001), whereas change in average performance was -0.18% (P < .001) per week for the year. CONCLUSIONS: Use of electronic monitoring with real-time prompts of 20 seconds' duration nearly doubles handwashing activity and causes handwashing to occur sooner after entering a patient room. These improvements are sustainable over a year.


Assuntos
Infecção Hospitalar/prevenção & controle , Fidelidade a Diretrizes , Higiene das Mãos , Controle de Infecções , Eletrônica , Desinfecção das Mãos , Pessoal de Saúde , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA