Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Ann Surg ; 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39145388

RESUMO

OBJECTIVE: Define recommendations for work-life integration and wellness and provide a pathway for supporting, teaching, and strengthening the skills needed to live as an authentic, empathic, compassionate, emotionally intelligent surgeon who provides the best care to patients. SUMMARY BACKGROUND DATA: Burnout is common during surgical residency. It is important to assess how we are addressing the human needs in surgical trainees. We report the recommendations of the work-life integration, wellness, and resilience subcommittee of the Blue Ribbon Committee II. METHODS: We met monthly via a virtual format and established the needs of the surgical trainee according to Maslow's Triangle. Barriers to meeting needs were identified, classified (local, state, national, etc.), and assigned to "easy" or "hard to address." Recommendations were developed for each Maslow's Triangle level and organized into 1-2- and 3-5-year goals. The Blue Ribbon Committee II (BRCII) narrowed these down to 6 recommendations that were included in a Delphi Analysis with 80% consensus needed to be included in the BRCII paper. RESULTS: Six recommendations were developed by the BRCII and four met consensus. Final recommendations addressed resident wages, a culture of belonging, workplace safety, and reporting mistreatment. CONCLUSION: Creating a culture of belonging by focusing on program culture through accountability, safety, and collaboration can lead surgical training programs to train highly successful surgeons.

2.
BJU Int ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38881297

RESUMO

OBJECTIVE: To investigate whether preoperative body morphometry analysis can identify patients at risk of parastomal hernia (PH), which is a common complication after radical cystectomy (RC). PATIENTS AND METHODS: All patients who underwent RC between 2010 and 2020 with available cross-sectional imaging preoperatively and at 1 and 2 years postoperatively were included. Skeletal muscle mass and total fat mass (FM) were determined from preoperative axial computed tomography images obtained at the level of the L3 vertebral body using Aquarius Intuition software. Sarcopenia and obesity were assigned based on consensus definitions of skeletal muscle index (SMI) and FM index (FMI). PH were graded using both the Moreno-Matias and European Hernia Society criteria. Binary logistic regression and recursive partitioning were used to identify patients at risk of PH. The Kaplan-Meier method with log-rank and Cox proportional hazards models included clinical and image-based parameters to identify predictors of PH-free survival. RESULTS: A total of 367 patients were included in the final analysis, with 159 (43%) developing a PH. When utilising binary logistic regression, high FMI (odds ratio [OR] 1.63, P < 0.001) and low SMI (OR 0.96, P = 0.039) were primary drivers of risk of PH. A simplified model that only relied upon FMI, SMI, and preoperative albumin improved the classification of patients at risk of PH. On Kaplan-Meier analysis, patients who were obese or obese and sarcopenic had significantly worse PH-free survival (P < 0.001). CONCLUSION: Body morphometry analysis identified FMI and SMI to be the most consistent predictors of PH after RC.

3.
J Surg Res ; 300: 1-7, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38788481

RESUMO

INTRODUCTION: The COVID-19 pandemic resulted in modifications to resident selection. The success of these new recruitment strategies as well as the impact on trainee attrition and competency is unknown. We previously evaluated how selection of general surgery applicants changed early in the pandemic. Here we supplement that work by reporting further modifications to the recruitment process and the perceived impact on resident attrition and competency. METHODS: An anonymous cross-sectional survey sent via the Association of Program Directors in Surgery listserv in June 2022 to programs directors (PDs) at Accreditation Council for Graduate Medical Education accredited general surgery programs. Surveys contained demographic questions, 5-point Likert scale questions evaluating factors related to recruitment and match process, and postgraduate year 1 performance. RESULTS: 60 PDs responded to the survey. PDs continue to value the same post-COVID factors related to determining a resident's commitment to surgery but began to shift back to nonvirtual based strategies to recruit applicants in this new interview cycle. PD commentary frequently noted desire to return to in-person interviewing. 5.4% of postgraduate year 1s comprising this first class of residents who underwent virtual-only interviews and rotations did not reach Accreditation Council for Graduate Medical Education level 1 milestones, similar to prior years. The attrition rate amongst this class increased from 1.3% to 2.7%. CONCLUSIONS: The attrition rate for postgraduate year 1 categorical general surgery residents has increased since the onset of the pandemic. The recruitment strategies adopted early in the pandemic have not maintained their initial perceived impact.


Assuntos
COVID-19 , Cirurgia Geral , Internato e Residência , Seleção de Pessoal , COVID-19/epidemiologia , Humanos , Internato e Residência/estatística & dados numéricos , Estudos Transversais , Cirurgia Geral/educação , Seguimentos , Inquéritos e Questionários , Educação de Pós-Graduação em Medicina , Feminino , Masculino , Competência Clínica/estatística & dados numéricos
4.
Surg Endosc ; 38(5): 2871-2878, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38609587

RESUMO

BACKGROUND: The use of mesh is standard of care for large ventral hernias repaired on an elective basis. The most used type of mesh includes synthetic polypropylene mesh; however, there has been an increase in the usage of a new polyester self-gripping mesh, and there are limited data regarding its efficacy for ventral hernia. The purpose of the study is to determine whether there is a difference in surgical site occurrence (SSO), surgical site infection (SSI), surgical site occurrence requiring procedural intervention (SSOPI), and recurrence at 30 days after ventral hernia repair (VHR) using self-gripping (SGM) versus non-self-gripping mesh (NSGM). METHODS: We performed a retrospective study from January 2014 to April 2022 using the Abdominal Core Health Quality Collaborative (ACHQC). We collected data on patients over 18 years of age who underwent elective open VHR using SGM or NSGM and whom had 30-day follow-up. Propensity matching was utilized to control for variables including hernia width, body mass index, age, ASA, and mesh location. Data were analyzed to identify differences in SSO, SSI, SSOPI, and recurrence at 30 days. RESULTS: 9038 patients were identified. After propensity matching, 1766 patients were included in the study population. Patients with SGM had similar demographic and clinical characteristics compared to NSGM. The mean hernia width to mesh width ratio was 8 cm:18 cm with NSGM and 7 cm:15 cm with SGM (p = 0.63). There was no difference in 30-day rates of recurrence, SSI or SSO. The rate of SSOPI was also found to be 5.4% in the nonself-gripping group compared to 3.1% in the self-gripping mesh group (p < .005). There was no difference in patient-reported outcomes at 30 days. CONCLUSIONS: In patients undergoing ventral hernia repair with mesh, self-gripping mesh is a safe type of mesh to use. Use of self-gripping mesh may be associated with lower rates of SSOPI when compared to nonself-gripping mesh.


Assuntos
Hérnia Ventral , Herniorrafia , Recidiva , Telas Cirúrgicas , Humanos , Hérnia Ventral/cirurgia , Estudos Retrospectivos , Masculino , Feminino , Herniorrafia/métodos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/epidemiologia , Adulto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
5.
Surg Endosc ; 38(4): 2019-2026, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38424284

RESUMO

INTRODUCTION: Intraperitoneal onlay mesh (IPOM) placement for small to medium-sized hernias has garnered negative attention due to perceived long-term risk of mesh-related complications. However, sparse data exists supporting such claims after minimally invasive (MIS) IPOM repairs and most is hindered by the lack of long-term follow-up. We sought to report long-term outcomes and mesh-related complications of MIS IPOM ventral hernia repairs. METHODS AND PROCEDURES: Adult patients who underwent MIS IPOM ventral hernia repair at our institution were identified in the Abdominal Core Health Quality Collaborative database from October 2013 to October 2020. Outcomes included hernia recurrence and mesh-related complications or reoperations up to 6 years postoperatively. RESULTS: A total of 325 patients were identified. The majority (97.2%) of cases were elective, non-recurrent (74.5%), and CDC class I (99.4%). Mean hernia width was 4.16 ± 3.86 cm. Median follow-up was 3.6 (IQR 2.8-5) years. Surgeon-entered or patient-reported follow-up was available for 253 (77.8%) patients at 3 years or greater postoperatively. One patient experienced an early small bowel obstruction and was reoperated on within 30 days. Two-hundred forty-five radiographic examinations were available up to 6 years postoperatively. Twenty-seven patients had hernia recurrence on radiographic examination up to 6 years postoperatively. During long-term follow-up, two mesh-related complications required reoperations: mesh removed for chronic pain and mesh removal at the time of colon surgery for perforated cancer. Sixteen additional patients required reoperation within 6 years for the following reasons: hernia recurrence (n = 5), unrelated intraabdominal pathology (n = 9), obstructed port site hernia (n = 1), and adhesive bowel obstruction unrelated to the prosthesis (n = 1). The rate of reoperation due to intraperitoneal mesh complications was 0.62% (2/325) with up to 6 year follow-up. CONCLUSION: Intraperitoneal mesh for repair of small to medium-sized hernias has an extremely low rate of long-term mesh-related complications. It remains a safe and durable option for hernia surgeons.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Hérnia Ventral , Hérnia Incisional , Obstrução Intestinal , Laparoscopia , Adulto , Humanos , Telas Cirúrgicas/efeitos adversos , Hérnia Ventral/cirurgia , Herniorrafia/efeitos adversos , Próteses e Implantes , Obstrução Intestinal/cirurgia , Hérnia Incisional/cirurgia , Recidiva
6.
Surg Endosc ; 38(9): 5338-5342, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39026006

RESUMO

BACKGROUND: Gender representation trends at the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) Annual Meetings and the effect of the 2018 'We R SAGES' initiatives are unknown. We assessed gender trends in oral presentations at the SAGES Annual Meeting between 2012 and 2022 with a focus on assessing the impact of the 2018 initiatives. METHODS: Abstracts selected for oral presentations from 2012 to 2022 were reviewed for presenter and first, second, and senior author gender. Gender was categorized as woman, man, or unknown using public professional profiles. Subsequent publications were identified using search engines. The primary outcome was the temporal trend of proportion of women in each role using interrupted time series analysis. Secondary outcomes included publication rates based on first and senior author genders in 2012-2018 versus 2019-2022. RESULTS: 1605 abstracts were reviewed. The proportion of women increased linearly in all categories: presenter (2.4%/year, R2 = 0.91), first author (2.4%/year, R2 = 0.90), senior author (2%/year, R2 = 0.65), and overall (2.2%, R2 = 0.91), (p < 0.01 for all). Prior to 2018, the proportion of women increased annually for presenters (coefficient: 0.026, 95% CI [0.016, 0.037], p = 0.002) and first authors (coefficient: 0.026, 95% CI [0.016, 0.037], p = 0.002), but there was no significant increase after 2018 (p > 0.05). Female second author proportion increased annually prior to 2018 (coefficient: 0.012, 95% CI [0.003, 0.021], p = 0.042) and increased by 0.139 (95% CI [0.070, 0.208], p = 0.006) in 2018. Annual female senior author proportion did not significantly change after 2018 (p > 0.05). 1198 (75.2%) abstracts led to publications. Women were as likely as men to be first (79% vs 77%, p = 0.284) or senior author (79% vs 77%, p = 0.702) in abstracts culminating in publications. There was no difference in woman first author publication rate before and after 2018 (80% vs 79%, p = 1.000), but woman senior author publication rate increased after 2018 (71% vs 83%, p = 0.032). CONCLUSION: There was an upward trend in women surgeons' presentations and associated publications in the SAGES Annual Meetings over the last decade.


Assuntos
Congressos como Assunto , Médicas , Sociedades Médicas , Humanos , Feminino , Congressos como Assunto/estatística & dados numéricos , Sociedades Médicas/estatística & dados numéricos , Estudos Transversais , Médicas/estatística & dados numéricos , Masculino , Estados Unidos , Autoria , Gastroenterologia/estatística & dados numéricos
7.
Surg Endosc ; 38(7): 4006-4013, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38862822

RESUMO

BACKGROUND: Mediumweight (40-60 g/m2) polypropylene (MWPP) mesh has been shown to be safe and effective in CDC class II-III retromuscular ventral hernia repairs (RMVHR). However, MWPP has the potential to fracture, and it is possible that heavyweight (> 75 g/m2) polypropylene mesh has similar outcomes in this context. However, there is limited data on HWPP mesh performance in clean-contaminated and contaminated scenarios. We aimed to compare HWPP to MWPP mesh in CDC class II-III wounds during open RMVHR. METHODS: The Abdominal Core Health Quality Collaborative database was retrospectively queried for a cohort of patients who underwent open RMVHR with MWPP or HWPP mesh placed in CDC class II/III wounds from 2012 to 2023. Mesh types were compared using a 3:1 propensity score-matched analysis. Covariates for matching included CDC classification, BMI, diabetes, smoking within 1 year, hernia, and mesh width. Primary outcome of interest included wound complications. Secondary outcomes included reoperations and readmissions at 30 days. RESULTS: A total of 1496 patients received MWPP or HWPP (1378 vs. 118, respectively) in contaminated RMVHR. After propensity score matching, 351 patients remained in the mediumweight and 117 in the heavyweight mesh group. There were no significant differences in surgical site infection (SSI) rates (13.4% vs. 14.5%, p = 0.877), including deep SSIs (0.3% vs. 0%, p = 1), surgical site occurrence rates (17.9% vs. 22.2%, p = 0.377), surgical site occurrence requiring procedural intervention (16% vs. 17.9%, p = 0.719), mesh removal (0.3% vs. 0%, p = 1), reoperations (4.6% vs. 2.6%, p = 0.428), or readmissions (12.3% vs. 9.4%, p = 0.504) at 30 days. CONCLUSION: HWPP mesh was not associated with increased wound morbidity, mesh excisions, reoperations, or readmissions in the early postoperative period compared with MWPP mesh in open RMVHR for CDC II/III cases. Longer follow-up will be necessary to determine if HWPP mesh may be a suitable alternative to MWPP mesh in contaminated scenarios.


Assuntos
Hérnia Ventral , Herniorrafia , Polipropilenos , Telas Cirúrgicas , Infecção da Ferida Cirúrgica , Humanos , Hérnia Ventral/cirurgia , Estudos Retrospectivos , Telas Cirúrgicas/efeitos adversos , Masculino , Feminino , Herniorrafia/métodos , Herniorrafia/efeitos adversos , Pessoa de Meia-Idade , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Idoso , Resultado do Tratamento , Readmissão do Paciente/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
8.
Surg Endosc ; 38(6): 3433-3440, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38710888

RESUMO

INTRODUCTION: Fixation of mesh during minimally invasive inguinal hernia repair is thought to contribute to chronic post-herniorrhaphy groin pain (CGP). In contrast to permanent tacks, absorbable tacks are hypothesized to minimize the likelihood of CGP. This study aimed to compare the rates of CGP after laparoscopic inguinal hernia repair between absorbable versus permanent fixation at maximum follow-up. METHODS: This is a post hoc analysis of a randomized controlled trial in patients undergoing laparoscopic inguinal hernia repair (NCT03835351). All patients were contacted at maximum follow-up after surgery to administer EuraHS quality of life (QoL) surveys. The pain and restriction of activity subdomains of the survey were utilized. The primary outcome was rate of CGP, as defined by a EuraHS QoL pain domain score ≥ 4 measured at ≥ 1 year postoperatively. The secondary outcomes were pain and restriction of activity domain scores and hernia recurrence at maximum follow-up. RESULTS: A total of 338 patients were contacted at a mean follow-up of 28 ± 11 months. 181 patients received permanent tacks and 157 patients received absorbable tacks during their repair. At maximum follow-up, the rates of CGP (27 [15%] vs 28 [18%], P = 0.47), average pain scores (1.78 ± 4.38 vs 2.32 ± 5.40, P = 0.22), restriction of activity scores (1.39 ± 4.32 vs 2.48 ± 7.45, P = 0.18), and the number of patients who reported an inguinal bulge (18 [9.9%] vs 15 [9.5%], P = 0.9) were similar between patients with permanent versus absorbable tacks. On multivariable analysis, there was no significant difference in the odds of CGP between the two groups (OR 1.23, 95% CI [0.60, 2.50]). CONCLUSION: Mesh fixation with permanent tacks does not appear to increase the risk of CGP after laparoscopic inguinal hernia repair when compared to fixation with absorbable tacks. Prospective trials are needed to further evaluate this relationship.


Assuntos
Implantes Absorvíveis , Dor Crônica , Virilha , Hérnia Inguinal , Herniorrafia , Laparoscopia , Dor Pós-Operatória , Telas Cirúrgicas , Humanos , Hérnia Inguinal/cirurgia , Laparoscopia/métodos , Laparoscopia/efeitos adversos , Herniorrafia/métodos , Herniorrafia/efeitos adversos , Masculino , Dor Pós-Operatória/etiologia , Pessoa de Meia-Idade , Feminino , Virilha/cirurgia , Dor Crônica/etiologia , Idoso , Qualidade de Vida , Seguimentos , Adulto
9.
Ann Surg ; 277(4): e900-e906, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35793810

RESUMO

OBJECTIVE: We aimed to report long-term clinical and patient-reported outcomes of transversus abdominis release (TAR) with permanent synthetic mesh performed in a high-volume abdominal wall reconstruction practice. SUMMARY BACKGROUND DATA: Despite increasing utilization of TAR in abdominal wall reconstruction, long-term clinical and patient-reported outcomes remain uncertain. METHODS: Prospectively collected registry data from the Cleveland Clinic Center for Abdominal Core Health were analyzed retrospectively. Patients undergoing elective, open VHR with TAR and permanent synthetic mesh implantation between August 2014 and March 2020 with 30-day clinical and ≥1 year clinical or patient-reported outcome follow-up were included. Outcomes included composite hernia recurrence, characterized by patient-reported bulges and recurrent hernias noted on physical exam or imaging, as well as hernia-specific quality of life and pain. RESULTS: A total of 1203 patients were included. Median age was 60 years [interquartile range (IQR): 52-67], median body mass index was 32 kg/m 2 (IQR: 28-36), median hernia width was 15 cm (IQR: 12-19), and 57% of hernias were recurrent. Fascial reapproximation was achieved in 92%. At a median follow-up of 2 years (IQR: 1-4), the overall composite hernia recurrence rate was 26%, with sensitivity analysis yielding best-case and worst-case estimates of 5% and 28%, respectively. Patients experienced improved hernia-specific quality of life and pain regardless of recurrence outcome; however, those who did not recur experienced more substantial improvement. CONCLUSIONS: TAR with permanent synthetic mesh remains a valuable, versatile technique; however, surgeon and patient expectations should be tempered regarding long-term durability. Despite a high rate of recurrence, patients experience measurable improvements in quality of life.


Assuntos
Parede Abdominal , Hérnia Ventral , Humanos , Pessoa de Meia-Idade , Hérnia Ventral/cirurgia , Estudos Retrospectivos , Telas Cirúrgicas , Qualidade de Vida , Resultado do Tratamento , Herniorrafia/métodos , Músculos Abdominais/cirurgia , Medidas de Resultados Relatados pelo Paciente , Dor , Recidiva , Parede Abdominal/cirurgia
10.
Surg Endosc ; 37(11): 8799-8803, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37592045

RESUMO

INTRODUCTION: Core abdominal injury (CAI) is a broad term that describes injuries resulting from repetitive loading of the pubis that leads to inflammation, rupture, or destabilization of the core muscles from the pubic bone. There is no clear recommendation on the surgical approach to CAI. We aimed to describe how hernia surgeons within the Abdominal Core Health Quality Collaborative (ACHQC) address this problem surgically and the short-term outcomes. METHODS: We queried the ACHQC registry for patients undergoing surgery for isolated CAI and concomitant inguinal hernias (IH) and CAI. Operative approach and quality of life (using EuraHS survey scores) was abstracted. RESULTS: A total of 29,451 patients underwent surgery for IHs, CAIs, or both within the registry. Twenty patients underwent surgery for isolated CAI (median age 29, 90% males). Eleven patients (55%) underwent surgery with mesh (four Lichtenstein, three TAPP, and four TEP). Nine patients (45%) underwent tissue-based repairs (four closure of floor, one Bassini, one McVay, one Shouldice, one femoral exploration, and one laparoscopic-to-open conversion). There were no postoperative complications or reoperations within 30 days. EuraHS scores showed improvement at 30 days from baseline (median 29 [6.75-41.75] from 42 [29.42-57.61]). Sixty patients had both IHs and CAIs (median age 31, 97% males). All patients received mesh. Thirty-one patients (52%) underwent open surgery (23 Lichtenstein, 1 plug, 7 TREPP) and 29 underwent minimally invasive repairs (23 TAPP, 6 TEP). There was one seroma at 30 days. EuraHS scores showed improvement at 30 days from baseline (median 16 [5.17-27.33] from 37.5 [26.44-46.58]). CONCLUSIONS: Despite technical variability, CAIs with or without concomitant IH generally undergo operations commonly used for IH repairs. Within our series, there was inconsistency with approach and mesh placement. Future work should be focused on standardizing the approach to CAI and capturing long-term data within the ACHQC.


Assuntos
Traumatismos Abdominais , Hérnia Inguinal , Laparoscopia , Masculino , Humanos , Adulto , Feminino , Herniorrafia/métodos , Qualidade de Vida , Telas Cirúrgicas , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Laparoscopia/métodos , Hérnia Inguinal/cirurgia , Traumatismos Abdominais/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA