Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Eur Radiol ; 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38175219

RESUMO

OBJECTIVES: Cardiac motion artifacts hinder the assessment of coronary arteries in coronary computed tomography angiography (CCTA). We investigated the impact of motion compensation reconstruction (MCR) on motion artifacts in CCTA at various heart rates (HR) using a dynamic phantom. MATERIALS AND METHODS: An artificial hollow coronary artery (5-mm diameter lumen) filled with iodinated contrast agent (400 HU at 120 kVp), positioned centrally in an anthropomorphic chest phantom, was scanned using a dual-layer spectral detector CT. The artery was translated at constant horizontal velocities (0-80 mm/s, increment of 10 mm/s). For each velocity, five CCTA scans were repeated using a clinical protocol. Motion artifacts were quantified using the in-plane motion area. Regression analysis was performed to calculate the reduction in motion artifacts provided by MCR, by division of the slopes of non-MCR and MCR fitted lines. RESULTS: Reference mean (95% confidence interval) motion artifact area was 24.9 mm2 (23.8, 26.0). Without MCR, motion artifact areas for velocities exceeding 20 mm/s were significantly larger (up to 57.2 mm2 (40.1, 74.2)) than the reference. With MCR, no significant differences compared to the reference were shown for all velocities, except for 70 mm/s (29.0 mm2 (27.0, 31.0)). The slopes of the fitted data were 0.44 and 0.04 for standard and MCR reconstructions, respectively, resulting in an 11-time motion artifact reduction. CONCLUSION: MCR may improve CCTA assessment in patients by reducing coronary artery motion artifacts, especially in those with elevated HR who cannot receive beta blockers or do not attain the targeted HR. CLINICAL RELEVANCE STATEMENT: This vendor-specific motion compensation reconstruction may improve coronary computed tomography angiography assessment in patients by reduction of coronary artery motion artifacts, especially in those with elevated various heart rates (HR) who cannot receive beta blockers or do not attain the targeted HR. KEY POINTS: • Motion artifacts are known to hinder the assessment of coronary arteries on coronary CT angiography (CCTA), leading to more non-diagnostic scans. • This dynamic phantom study shows that motion compensation reconstruction (MCR) reduces motion artifacts at various velocities, which may help to decrease the number of non-diagnostic scans. • MCR in this study showed to reduce motion artifacts 11-fold.

2.
Eur Radiol ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789792

RESUMO

BACKGROUND: The aim of our current systematic dynamic phantom study was first, to optimize reconstruction parameters of coronary CTA (CCTA) acquired on photon counting CT (PCCT) for coronary artery calcium (CAC) scoring, and second, to assess the feasibility of calculating CAC scores from CCTA, in comparison to reference calcium scoring CT (CSCT) scans. METHODS: In this phantom study, an artificial coronary artery was translated at velocities corresponding to 0, < 60, and 60-75 beats per minute (bpm) within an anthropomorphic phantom. The density of calcifications was 100 (very low), 200 (low), 400 (medium), and 800 (high) mgHA/cm3, respectively. CCTA was reconstructed with the following parameters: virtual non-iodine (VNI), with and without iterative reconstruction (QIR level 2, QIR off, respectively); kernels Qr36 and Qr44f; slice thickness/increment 3.0/1.5 mm and 0.4/0.2 mm. The agreement in risk group classification between CACCCTA and CACCSCT scoring was measured using Cohen weighted linear κ with 95% CI. RESULTS: For CCTA reconstructed with 0.4 mm slice thickness, calcium detectability was perfect (100%). At < 60 bpm, CACCCTA of low, and medium density calcification was underestimated by 53%, and 15%, respectively. However, CACCCTA was not significantly different from CACCSCT of very low, and high-density calcifications. The best risk agreement was achieved when CCTA was reconstructed with QIR off, Qr44f, and 0.4 mm slice thickness (κ = 0.762, 95% CI 0.671-0.853). CONCLUSION: In this dynamic phantom study, the detection of calcifications with different densities was excellent with CCTA on PCCT using thin-slice VNI reconstruction. Agatston scores were underestimated compared to CSCT but agreement in risk classification was substantial. CLINICAL RELEVANCE STATEMENT: Photon counting CT may enable the implementation of coronary artery calcium scoring from coronary CTA in daily clinical practice. KEY POINTS: Photon-counting CTA allows for excellent detectability of low-density calcifications at all heart rates. Coronary artery calcium scoring from coronary CTA acquired on photon counting CT is feasible, although improvement is needed. Adoption of the standard acquisition and reconstruction protocol for calcium scoring is needed for improved quantification of coronary artery calcium to fully employ the potential of photon counting CT.

3.
J Nucl Cardiol ; 30(1): 239-250, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35708853

RESUMO

BACKGROUND: Coronary artery calcium is a well-known predictor of major adverse cardiac events and is usually scored manually from dedicated, ECG-triggered calcium scoring CT (CSCT) scans. In clinical practice, a myocardial perfusion PET scan is accompanied by a non-ECG triggered low dose CT (LDCT) scan. In this study, we investigated the accuracy of patients' cardiovascular risk categorisation based on manual, visual, and automatic AI calcium scoring using the LDCT scan. METHODS: We retrospectively enrolled 213 patients. Each patient received a 13N-ammonia PET scan, an LDCT scan, and a CSCT scan as the gold standard. All LDCT and CSCT scans were scored manually, visually, and automatically. For the manual scoring, we used vendor recommended software (Syngo.via, Siemens). For visual scoring a 6-points risk scale was used (0; 1-10; 11-100; 101-400; 401-100; > 1 000 Agatston score). The automatic scoring was performed with deep learning software (Syngo.via, Siemens). All manual and automatic Agatston scores were converted to the 6-point risk scale. Manual CSCT scoring was used as a reference. RESULTS: The agreement of manual and automatic LDCT scoring with the reference was low [weighted kappa 0.59 (95% CI 0.53-0.65); 0.50 (95% CI 0.44-0.56), respectively], but the agreement of visual LDCT scoring was strong [0.82 (95% CI 0.77-0.86)]. CONCLUSIONS: Compared with the gold standard manual CSCT scoring, visual LDCT scoring outperformed manual LDCT and automatic LDCT scoring.


Assuntos
Cálcio , Doença da Artéria Coronariana , Humanos , Amônia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Vasos Coronários , Tomografia por Emissão de Pósitrons
4.
Eur Heart J ; 43(12): 1251-1264, 2022 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-34932122

RESUMO

AIMS: Exercise increases arrhythmia risk and cardiomyopathy progression in arrhythmogenic right ventricular cardiomyopathy (ARVC) patients, but the mechanisms remain unknown. We investigated transcriptomic changes caused by endurance training in mice deficient in plakophilin-2 (PKP2cKO), a desmosomal protein important for intercalated disc formation, commonly mutated in ARVC and controls. METHODS AND RESULTS: Exercise alone caused transcriptional downregulation of genes coding intercalated disk proteins. The changes converged with those in sedentary and in exercised PKP2cKO mice. PKP2 loss caused cardiac contractile deficit, decreased muscle mass and increased functional/transcriptomic signatures of apoptosis, despite increased fractional shortening and calcium transient amplitude in single myocytes. Exercise accelerated cardiac dysfunction, an effect dampened by pre-training animals prior to PKP2-KO. Consistent with PKP2-dependent muscle mass deficit, cardiac dimensions in human athletes carrying PKP2 mutations were reduced, compared to matched controls. CONCLUSIONS: We speculate that exercise challenges a cardiomyocyte "desmosomal reserve" which, if impaired genetically (e.g., PKP2 loss), accelerates progression of cardiomyopathy.


Assuntos
Displasia Arritmogênica Ventricular Direita , Condicionamento Físico Animal , Placofilinas , Animais , Displasia Arritmogênica Ventricular Direita/genética , Humanos , Camundongos , Camundongos Knockout , Mutação , Miocárdio/metabolismo , Miócitos Cardíacos/fisiologia , Placofilinas/genética , Placofilinas/metabolismo
5.
Eur J Nucl Med Mol Imaging ; 49(10): 3430-3451, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35376992

RESUMO

PURPOSE: Consensus on optimal imaging procedure for vascular graft/endograft infection (VGEI) is still lacking and the choice of a diagnostic test is often based on the experience of single centres. This document provides evidence-based recommendations aiming at defining which imaging modality may be preferred in different clinical settings and post-surgical time window. METHODS: This working group includes 6 nuclear medicine physicians appointed by the European Association of Nuclear Medicine, 4 vascular surgeons, and 2 radiologists. Vascular surgeons formulated 5 clinical questions that were converted into 10 statements and addressed through a systematic analysis of available literature by using PICOs (Population/problem-Intervention/Indicator-Comparator-Outcome) strategy. Each consensus statement was scored for level of evidence and for recommendation grade, according to the Oxford Centre for Evidence-based Medicine criteria. RESULTS: Sixty-six articles, published from January 2000 up to December 2021, were analysed and used for evidence-based recommendations. CONCLUSION: Computed tomography angiography (CTA) is the first-line imaging modality in suspected VGEI but nuclear medicine modalities are often needed to confirm or exclude the infection. Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) has very high negative predictive value but it should be performed preferably at least 4 months after surgery to avoid false positive results. Radiolabelled white blood cell (WBC) scintigraphy, given its high diagnostic accuracy, can be performed at any time after surgery. PREAMBLE: The European Association of Nuclear Medicine (EANM) is a professional no-profit medical association that facilitates communication worldwide between individuals pursuing clinical and research excellence in nuclear medicine. The EANM was founded in 1985. EANM members are physicians, technologists, and scientists specializing in the research and practice of nuclear medicine. The EANM will periodically define new guidelines for nuclear medicine practice to help advance the science of nuclear medicine and to improve the quality of service to patients throughout the world. Existing practice guidelines will be reviewed for revision or renewal, as appropriate, on their fifth anniversary or sooner, if indicated. Each practice guideline, representing a policy statement by the EANM, has undergone a thorough consensus process in which it has been subjected to extensive review. The EANM recognizes that the safe and effective use of diagnostic nuclear medicine imaging requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guideline by those entities not providing these services is not authorized. These guidelines are an educational tool designed to assist practitioners in providing appropriate care for patients. They are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. For these reasons and those set forth below, the EANM suggests caution against the use of the current consensus document in litigation in which the clinical decisions of a practitioner are called into question. The ultimate judgement regarding the propriety of any specific procedure or course of action must be made by the physician or medical physicist in the light of all the circumstances presented. Thus, there is no implication that an approach differing from the consensus document, standing alone, is below the standard of care. To the contrary, a conscientious practitioner may responsibly adopt a course of action different from that set forth in the consensus document when, in the reasonable judgement of the practitioner, such course of action is indicated by the condition of the patient, limitations of available resources, or advances in knowledge or technology subsequent to publication of the consensus document. The practice of medicine includes both the art and the science of the prevention, diagnosis, alleviation, and treatment of disease. The variety and complexity of human conditions make it impossible to always reach the most appropriate diagnosis or to predict with certainty a particular response to treatment. Therefore, it should be recognized that adherence to this consensus document will not ensure an accurate diagnosis or a successful outcome. All that should be expected is that the practitioner will follow a reasonable course of action based on current knowledge, available resources, and the needs of the patient, to deliver effective and safe medical care. The sole purpose of this consensus document is to assist practitioners in achieving this objective.


Assuntos
Medicina Nuclear , Consenso , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Cintilografia
6.
Ann Vasc Surg ; 84: 225-238, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35104593

RESUMO

BACKGROUND: The existing literature on mycotic aortic aneurysm is scarce and focuses on treatment. This study evaluates the clinical characteristics, diagnostics, treatment and outcome of patients with a mycotic abdominal aortic aneurysm treated in a tertiary referral center. METHODS: A retrospective cohort study was conducted including all patients with a proven mycotic abdominal aortic aneurysm admitted between May 2010 and July 2020. Primary outcome was mortality and secondary outcome included complications such as vascular graft/endograft infection. RESULTS: Twenty-four patients with a mycotic abdominal aortic aneurysm were included. Patients had a mean age of 68 ± 9 years and 20 (83%) were male. Thirteen patients (57%) had positive preoperative blood cultures. Streptococcus pneumoniae was most frequently isolated by blood culturing, pus, and vascular, or perivascular tissue cultures (17%). In 19 (83%) patients the mycotic abdominal aortic aneurysm was located infrarenally, in three (13%) patients suprarenally, and in one (4%) patient juxtarenally. Median follow-up was 20 (7-42) months. In 8 patients (33%) vascular graft and or endograft infection was diagnosed after surgical repair. Ten (42%) patients died during the follow-up period. The main causes of death were vascular graft/endograft infection-related (n = 4) and rupture of the mycotic abdominal aortic aneurysm (n = 3). No patient characteristics could be identified as predictive for mortality. CONCLUSIONS: This study shows a large variation in presentation, diagnostic approaches, and surgical and antibiotic treatment of mycotic abdominal aortic aneurysm. The detailed information about the diagnostic approaches to this rare disease and its antibiotic and/or other treatment contributes to existing knowledge of mycotic abdominal aortic aneurysm. Because of the individual variation patients should be discussed in a multidisciplinary team with a vascular surgeon, infectious disease specialist, and clinical microbiologist.


Assuntos
Aneurisma Infectado , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aneurisma Infectado/diagnóstico por imagem , Aneurisma Infectado/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/etiologia , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
7.
Circulation ; 141(16): 1338-1350, 2020 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-32310695

RESUMO

Physical activity and exercise training are effective strategies for reducing the risk of cardiovascular events, but multiple studies have reported an increased prevalence of coronary atherosclerosis, usually measured as coronary artery calcification, among athletes who are middle-aged and older. Our review of the medical literature demonstrates that the prevalence of coronary artery calcification and atherosclerotic plaques, which are strong predictors for future cardiovascular morbidity and mortality, was higher in athletes compared with controls, and was higher in the most active athletes compared with less active athletes. However, analysis of plaque morphology revealed fewer mixed plaques and more often only calcified plaques among athletes, suggesting a more benign composition of atherosclerotic plaques. This review describes the effects of physical activity and exercise training on coronary atherosclerosis in athletes who are middle-aged and older and aims to contribute to the understanding of the potential adverse effects of the highest doses of exercise training on the coronary arteries. For this purpose, we will review the association between exercise and coronary atherosclerosis measured using computed tomography, discuss the potential underlying mechanisms for exercise-induced coronary atherosclerosis, determine the clinical relevance of coronary atherosclerosis in middle-aged athletes and describe strategies for the clinical management of athletes with coronary atherosclerosis to guide physicians in clinical decision making and treatment of athletes with elevated coronary artery calcification scores.


Assuntos
Atletas , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Exercício Físico , Placa Aterosclerótica , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/mortalidade , Placa Aterosclerótica/fisiopatologia , Placa Aterosclerótica/terapia , Prevalência , Fatores de Risco , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/mortalidade , Calcificação Vascular/fisiopatologia , Calcificação Vascular/terapia
8.
Radiology ; 294(3): 538-545, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31961241

RESUMO

Background Myocardial oxygenation imaging could help determine the presence of microvascular dysfunction associated with increased cardiovascular risk. However, it is challenging to depict the potentially small oxygenation alterations with current noninvasive cardiac MRI blood oxygen level-dependent (BOLD) techniques. Purpose To demonstrate the cardiac application of a gradient-echo spin-echo (GESE) echo-planar imaging sequence for dynamic and quantitative heartbeat-to-heartbeat BOLD MRI and evaluate the sequence in populations both healthy and with hypertension in combination with a breath hold-induced CO2 intervention. Materials and Methods GESE echo-planar imaging sequence was performed in 18 healthy participants and in eight prospectively recruited participants with hypertension on a 3.0-T MRI system. T2 and T2* maps were calculated per heartbeat with a four-parameter fitting technique. Septal regions of interests were used to determine T2 and T2* values per heartbeat and examined over the course of a breath hold to determine BOLD changes. T2 and T2* changes of healthy participants and participants with hypertension were compared by using a nonparametric Mann-Whitney test. Results GESE echo-planar imaging approach gave spatially stable T2 and T2* maps per heartbeat for healthy participants and participants with hypertension, with mean T2 values of 43 msec ± 5 (standard deviation) and 46 msec ± 9, respectively, and mean T2* values of 28 msec ± 5 and 22 msec ± 5, respectively. The healthy participants exhibited increasing T2 and T2* values over the course of a breath hold with a mean positive slope of 0.2 msec per heartbeat ± 0.1 for T2 and 0.2 msec per heartbeat ± 0.1 for T2*, whereas for participants with hypertension these dynamic T2 and T2* values had a mean negative slope of -0.2 msec per heartbeat ± 0.2 for T2 and -0.1 msec per heartbeat ± 0.2 for T2*. The difference in these mean slopes between healthy participants and participants with hypertension was significant for both T2 (P < .001) and T2* (P < .001). Conclusion Gradient-echo spin-echo echo-planar imaging sequence provided quantitative T2 and T2* maps per heartbeat and enabled dynamic heartbeat-to-heartbeat blood oxygen level-dependent (BOLD)-response imaging by analyzing changes in T2 and T2* over the time of a breath-hold intervention. This approach could identify differences in the BOLD response between healthy participants and participants with hypertension. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Friedrich in this issue.


Assuntos
Imagem Ecoplanar/métodos , Coração/diagnóstico por imagem , Oxigênio/sangue , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
J Nucl Cardiol ; 27(2): 592-608, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-30066279

RESUMO

BACKGROUND: Multimodality imaging is recommended to diagnose infective endocarditis. Value of additional imaging to echocardiography in patients selected by a previously proposed flowchart has not been evaluated. METHODS: An observational single-center study was performed. Adult patients suspected of endocarditis/device infection were prospectively and consecutively enrolled from March 2016 to August 2017. Adherence to a diagnostic imaging-in-endocarditis-flowchart was evaluated in 176 patients. Imaging techniques were compared head-to-head in 46 patients receiving echocardiography (transthoracic plus transesophageal), multi-detector computed tomography angiography (MDCTA), and 18F-fluorodeoxyglucose positron emission tomography (FDG-PET/CT). RESULTS: 69% of patients (121/176) adhered to the flowchart. Sensitivity of echocardiography, MDCTA, FDG-PET/CT in patients without prosthesis was 71%, 57%, 29% (86% when combined), while specificity was 100%, 75%, 100%, respectively. Sensitivity in patients with prosthesis was 75%, 75%, 83%, respectively (100% when combined), while specificity was 86% for all three modalities. Echocardiography performed best in the assessment of vegetations, morphological valve abnormalities/dehiscence, septum defects, and fistula formation. MDCTA performed best in the assessment of abscesses and ventricular assist device infection. FDG-PET/CT performed best in the assessment of cardiac device infection, extracardiac infectious foci, and alternative diagnoses. CONCLUSIONS: This study demonstrates that the evaluated imaging-in-endocarditis-flowchart is applicable in daily clinical practice. Echocardiography, MDCTA, and FDG-PET/CT provide relevant complementary diagnostic information, particularly in patients with intracardiac prosthetic material.


Assuntos
Endocardite Bacteriana/diagnóstico por imagem , Endocardite/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Desfibriladores Implantáveis , Ecocardiografia , Feminino , Fluordesoxiglucose F18 , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Marca-Passo Artificial , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Infecções Relacionadas à Prótese , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Design de Software , Adulto Jovem
10.
J Nucl Cardiol ; 26(6): 1904-1913, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30834496

RESUMO

Noninvasive imaging modalities offer the possibility to dynamically evaluate cardiac motion during the cardiac cycle by means of ECG-gated acquisitions. Such motion characterization along with orientation, segmentation preprocessing, and ultimately, phase analysis, can provide quantitative estimates of ventricular mechanical synchrony. Current evidence on the role of mechanical synchrony evaluation is mainly available for echocardiography and gated single-photon emission computed tomography, but less is known about the utilization of gated positron emission tomography (PET). Although data available are sparse, there is indication that mechanical synchrony evaluation can be of diagnostic and prognostic values in patients with known or suspected coronary artery disease-related myocardial ischemia, prediction of response to cardiac resynchronization therapy, and estimation of risk for adverse cardiac events in patients' heart failure. As such, the evaluation of mechanical ventricular synchrony through phase analysis of gated acquisitions represents a value addition to modern cardiac PET imaging modality, which warrants further research and development in the evaluation of patients with cardiovascular disease.


Assuntos
Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Disfunção Ventricular Esquerda/diagnóstico por imagem , Terapia de Ressincronização Cardíaca , Doença da Artéria Coronariana , Imagem do Acúmulo Cardíaco de Comporta , Insuficiência Cardíaca , Humanos , Imagem de Perfusão do Miocárdio , Prognóstico , Compostos Radiofarmacêuticos , Valores de Referência , Risco , Tomografia Computadorizada de Emissão de Fóton Único
11.
Circulation ; 136(2): 138-148, 2017 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-28450347

RESUMO

BACKGROUND: Higher levels of physical activity are associated with a lower risk of cardiovascular events. Nevertheless, there is debate on the dose-response relationship of exercise and cardiovascular disease outcomes and whether high volumes of exercise may accelerate coronary atherosclerosis. We aimed to determine the relationship between lifelong exercise volumes and coronary atherosclerosis. METHODS: Middle-aged men engaged in competitive or recreational leisure sports underwent a noncontrast and contrast-enhanced computed tomography scan to assess coronary artery calcification (CAC) and plaque characteristics. Participants reported lifelong exercise history patterns. Exercise volumes were multiplied by metabolic equivalent of task (MET) scores to calculate MET-minutes per week. Participants' activity was categorized as <1000, 1000 to 2000, or >2000 MET-min/wk. RESULTS: A total of 284 men (age, 55±7 years) were included. CAC was present in 150 of 284 participants (53%) with a median CAC score of 35.8 (interquartile range, 9.3-145.8). Athletes with a lifelong exercise volume >2000 MET-min/wk (n=75) had a significantly higher CAC score (9.4 [interquartile range, 0-60.9] versus 0 [interquartile range, 0-43.5]; P=0.02) and prevalence of CAC (68%; adjusted odds ratio [ORadjusted]=3.2; 95% confidence interval [CI], 1.6-6.6) and plaque (77%; ORadjusted=3.3; 95% CI, 1.6-7.1) compared with <1000 MET-min/wk (n=88; 43% and 56%, respectively). Very vigorous intensity exercise (≥9 MET) was associated with CAC (ORadjusted=1.47; 95% CI, 1.14-1.91) and plaque (ORadjusted=1.56; 95% CI, 1.17-2.08). Among participants with CAC>0, there was no difference in CAC score (P=0.20), area (P=0.21), density (P=0.25), and regions of interest (P=0.20) across exercise volume groups. Among participants with plaque, the most active group (>2000 MET-min/wk) had a lower prevalence of mixed plaques (48% versus 69%; ORadjusted=0.35; 95% CI, 0.15-0.85) and more often had only calcified plaques (38% versus 16%; ORadjusted=3.57; 95% CI, 1.28-9.97) compared with the least active group (<1000 MET-min/wk). CONCLUSIONS: Participants in the >2000 MET-min/wk group had a higher prevalence of CAC and atherosclerotic plaques. The most active group, however, had a more benign composition of plaques, with fewer mixed plaques and more often only calcified plaques. These observations may explain the increased longevity typical of endurance athletes despite the presence of more coronary atherosclerotic plaque in the most active participants.


Assuntos
Atletas , Doença da Artéria Coronariana/diagnóstico por imagem , Exercício Físico/fisiologia , Longevidade/fisiologia , Doença da Artéria Coronariana/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Fatores de Tempo , Tomografia Computadorizada por Raios X/tendências
13.
J Magn Reson Imaging ; 47(4): 891-912, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29131444

RESUMO

BACKGROUND: Although cardiac MR and T1 mapping are increasingly used to diagnose diffuse fibrosis based cardiac diseases, studies reporting T1 values in healthy and diseased myocardium, particular in nonischemic cardiomyopathies (NICM) and populations with increased cardiovascular risk, seem contradictory. PURPOSE: To determine the range of native myocardial T1 value ranges in patients with NICM and populations with increased cardiovascular risk. STUDY TYPE: Systemic review and meta-analysis. POPULATION: Patients with NICM, including hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (DCM), and patients with myocarditis (MC), iron overload, amyloidosis, Fabry disease, and populations with hypertension (HT), diabetes mellitus (DM), and obesity. FIELD STRENGTH/SEQUENCE: (Shortened) modified Look-Locker inversion-recovery MR sequence at 1.5 or 3T. ASSESSMENT: PubMed and Embase were searched following the PRISMA guidelines. STATISTICAL TESTS: The summary of standard mean difference (SMD) between the diseased and a healthy control populations was generated using a random-effects model in combination with meta-regression analysis. RESULTS: The SMD for HCM, DCM, and MC patients were significantly increased (1.41, 1.48, and 1.96, respectively, P < 0.01) compared with healthy controls. The SMD for HT patients with and without left-ventricle hypertrophy (LVH) together was significantly increased (0.19, P = 0.04), while for HT patients without LVH the SMD was zero (0.03, P = 0.52). The number of studies on amyloidosis, iron overload, Fabry disease, and HT patients with LVH did not meet the requirement to perform a meta-analysis. However, most studies reported a significantly increased T1 for amyloidosis and HT patients with LVH and a significant decreased T1 for iron overload and Fabry disease patients. DATA CONCLUSIONS: Native T1 mapping by using an (Sh)MOLLI sequence can potentially assess myocardial changes in HCM, DCM, MC, iron overload, amyloidosis, and Fabry disease compared to controls. In addition, it can help to diagnose left-ventricular remodeling in HT patients. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:891-912.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cardiomiopatias/patologia , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/patologia , Coração/diagnóstico por imagem , Humanos , Miocárdio/patologia , Valores de Referência , Fatores de Risco
14.
MAGMA ; 30(3): 239-254, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27981396

RESUMO

OBJECTIVES: Early detection of iron loading is affected by the reproducibility of myocardial contour assessment. A novel semi-automatic myocardial segmentation method is presented on contrast-optimized composite images and compared to the results of manual drawing. MATERIALS AND METHODS: Fifty-one short-axis slices at basal, mid-ventricular and apical locations from 17 patients were acquired by bright blood multi-gradient echo MRI. Four observers produced semi-automatic and manual myocardial contours on contrast-optimized composite images. The semi-automatic segmentation method relies on vector field convolution active contours to generate the endocardial contour. After creating radial pixel clusters on the myocardial wall, a combination of pixel-wise coefficient of variance (CoV) assessment and k-means clustering establishes the epicardial contour for each segment. RESULTS: Compared to manual drawing, semi-automatic myocardial segmentation lowers the variability of T2* quantification within and between observers (CoV of 12.05 vs. 13.86% and 14.43 vs. 16.01%) by improving contour reproducibility (P < 0.001). In the presence of iron loading, semi-automatic segmentation also lowers the T2* variability within and between observers (CoV of 13.14 vs. 15.19% and 15.91 vs. 17.28%). CONCLUSION: Application of semi-automatic myocardial segmentation on contrast-optimized composite images improves the reproducibility of T2* quantification.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Sobrecarga de Ferro/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Algoritmos , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
MAGMA ; 29(1): 17-27, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26530323

RESUMO

OBJECTIVES: Reproducibility of myocardial contour determination in cardiac magnetic resonance imaging is important, especially when determining T2* values per myocardial segment as a prognostic factor of heart failure or thalassemia. A method creating a composite image with contrasts optimized for drawing myocardial contours is introduced and compared with the standard method on a single image. MATERIALS AND METHODS: A total of 36 short-axis slices from bright-blood multigradient echo (MGE) T2* scans of 21 patients were acquired at eight echo times. Four observers drew free-hand myocardial contours on one manually selected T2* image (method 1) and on one image composed by blending three images acquired at TEs providing optimum contrast-to-noise ratio between the myocardium and its surrounding regions (method 2). RESULTS: Myocardial contouring by method 2 met higher interobserver reproducibility than method 1 (P < 0.001) with smaller Coefficient of variance (CoV) of T2* values in the presence of myocardial iron accumulation (9.79 vs. 15.91%) and in both global myocardial and mid-ventricular septum regions (12.29 vs. 16.88 and 5.76 vs. 8.16%, respectively). CONCLUSION: The use of contrast-optimized composite images in MGE data analysis improves reproducibility of myocardial contour determination, leading to increased consistency in the calculated T2* values enhancing the diagnostic impact of this measure of iron overload.


Assuntos
Meios de Contraste/química , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Adolescente , Adulto , Algoritmos , Feminino , Coração/fisiologia , Humanos , Ferro , Sobrecarga de Ferro/diagnóstico , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
16.
Med Phys ; 51(6): 4297-4310, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38323867

RESUMO

BACKGROUND: Cardiovascular disease is the most common cause of death worldwide, including infection and inflammation related conditions. Multiple studies have demonstrated potential advantages of hybrid positron emission tomography combined with computed tomography (PET/CT) as an adjunct to current clinical inflammatory and infectious biochemical markers. To quantitatively analyze vascular diseases at PET/CT, robust segmentation of the aorta is necessary. However, manual segmentation is extremely time-consuming and labor-intensive. PURPOSE: To investigate the feasibility and accuracy of an automated tool to segment and quantify multiple parts of the diseased aorta on unenhanced low-dose computed tomography (LDCT) as an anatomical reference for PET-assessed vascular disease. METHODS: A software pipeline was developed including automated segmentation using a 3D U-Net, calcium scoring, PET uptake quantification, background measurement, radiomics feature extraction, and 2D surface visualization of vessel wall calcium and tracer uptake distribution. To train the 3D U-Net, 352 non-contrast LDCTs from (2-[18F]FDG and Na[18F]F) PET/CTs performed in patients with various vascular pathologies with manual segmentation of the ascending aorta, aortic arch, descending aorta, and abdominal aorta were used. The last 22 consecutive scans were used as a hold-out internal test set. The remaining dataset was randomly split into training (n = 264; 80%) and validation (n = 66; 20%) sets. Further evaluation was performed on an external test set of 49 PET/CTs. The dice similarity coefficient (DSC) and Hausdorff distance (HD) were used to assess segmentation performance. Automatically obtained calcium scores and uptake values were compared with manual scoring obtained using clinical softwares (syngo.via and Affinity Viewer) in six patient images. intraclass correlation coefficients (ICC) were calculated to validate calcium and uptake values. RESULTS: Fully automated segmentation of the aorta using a 3D U-Net was feasible in LDCT obtained from PET/CT scans. The external test set yielded a DSC of 0.867 ± 0.030 and HD of 1.0 [0.6-1.4] mm, similar to an open-source model with a DSC of 0.864 ± 0.023 and HD of 1.4 [1.0-1.8] mm. Quantification of calcium and uptake values were in excellent agreement with clinical software (ICC: 1.00 [1.00-1.00] and 0.99 [0.93-1.00] for calcium and uptake values, respectively). CONCLUSIONS: We present an automated pipeline to segment the ascending aorta, aortic arch, descending aorta, and abdominal aorta on LDCT from PET/CT and to accurately provide uptake values, calcium scores, background measurement, radiomics features, and a 2D visualization. We call this algorithm SEQUOIA (SEgmentation, QUantification, and visualizatiOn of the dIseased Aorta) and is available at https://github.com/UMCG-CVI/SEQUOIA. This model could augment the utility of aortic evaluation at PET/CT studies tremendously, irrespective of the tracer, and potentially provide fast and reliable quantification of cardiovascular diseases in clinical practice, both for primary diagnosis and disease monitoring.


Assuntos
Automação , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Processamento de Imagem Assistida por Computador/métodos , Aorta/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Feminino , Estudos de Viabilidade , Masculino
17.
Biology (Basel) ; 12(2)2023 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-36829528

RESUMO

Vascular graft and endograft infections (VGEI) cause a serious morbidity and mortality burden. 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) imaging is frequently used in the diagnostic workup, but the additional value of abnormal (18F-FDG active and/or enlarged) locoregional lymph nodes is unknown. In this retrospective study, the additional diagnostic value of abnormal locoregional lymph nodes on 18F-FDG PET/CT imaging for VGEI was evaluated, including 54 patients with a culture-proven VGEI (defined according to the Management of Aortic Graft Infection [MAGIC] group classification) and 25 patients without VGEI. 18F-FDG PET/CT was qualitatively and quantitatively assessed for tracer uptake and pattern at the location of the vascular graft, and locoregional lymph node uptake and enlargement (>10 mm). 18F-FDG uptake intensity and pattern independently predicted the presence of VGEI by logistic regression (Χ2: 46.19, p < 0.001), with an OR of 7.38 (95% CI [1.65, 32.92], p = 0.009) and 18.32 (95% CI [3.95, 84.88], p < 0.001), respectively. Single visual assessment of abnormal locoregional lymph nodes predicted the presence of VGEI with a sensitivity of 35%, specificity of 96%, PPV of 95%, and NPV of 41%. The visual assessment of abnormal lymph nodes after qualitative assessment of 18F-FDG uptake intensity and pattern at the vascular graft location did not independently predict the presence of VGEI by logistic regression (Χ2: 3.60, p = 0.058; OR: 8.25, 95% CI [0.74, 63.37], p = 0.096). In conclusion, detection of abnormal locoregional lymph nodes on 18F-FDG PET/CT has a high specificity (96%) and PPV (95%) for VGEI. However, it did not add to currently used 18F-FDG PET/CT interpretation criteria.

18.
Int J Infect Dis ; 126: 22-27, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36375692

RESUMO

A vascular graft or endograft infection (VGEI) is a severe complication that can occur after vascular graft or endograft surgery and is associated with high morbidity and mortality rates. A multidisciplinary approach, consisting of a team of vascular surgeons, infectious diseases specialists, medical microbiologists, radiologists, nuclear medicine specialists, and hospital pharmacists, is needed to adequately diagnose and treat VGEI. A structured diagnostic, antibiotic, and surgical treatment algorithm helps clinical decision making and ultimately aims to improve the clinical outcome of patients with a VGEI.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Infecções Relacionadas à Prótese , Doenças Vasculares , Enxerto Vascular , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/cirurgia , Procedimentos Endovasculares/efeitos adversos , Doenças Vasculares/etiologia , Resultado do Tratamento
19.
Diagnostics (Basel) ; 13(10)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37238153

RESUMO

Inflammatory abdominal aortic aneurysms (iAAA) are a form of noninfectious aortitis in patients with abdominal aortic aneurysms (AAA). Ultrasound could help to detect iAAA early. This retrospective observational study assessed the potential of using ultrasound to detect iAAA in a case series of iAAA patients, and the diagnostic value of ultrasound to detect iAAA in consecutive patients in a follow-up for AAA, referred to as a feasibility study. In both studies, diagnosis of iAAA was based on a cuff surrounding the aneurysm using CT (golden standard). The case series included 13 patients (age 64 (61; 72) years; 100% male). The feasibility study included 157 patients (age 75 (67; 80) years; 84% male). In the case series, all iAAA patients showed a cuff surrounding the aortic wall on ultrasound. In the feasibility study with AAA patients, ultrasound yielded no cuff in 147 (93.6%; CT negative in all cases), a typic cuff in 8 (5.1%; CT positive in all cases), and an inconclusive cuff in 2 (1.3%; CT negative in both cases) patients. Sensitivity and specificity were 100% and 98.7%, respectively. This study indicates that iAAA can be identified with ultrasound, and safely ruled out. In positive ultrasound cases, additional CT imaging might still be warranted.

20.
Int J Antimicrob Agents ; 61(2): 106711, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36642232

RESUMO

OBJECTIVES: Voriconazole therapeutic drug monitoring (TDM) is recommended based on retrospective data and limited prospective studies. This study aimed to investigate whether TDM-guided voriconazole treatment is superior to standard treatment for invasive aspergillosis. METHODS: A multicentre (n = 10), prospective, cluster randomised, crossover clinical trial was performed in haematological patients aged ≥18 years treated with voriconazole. All patients received standard voriconazole dose at the start of treatment. Blood/serum/plasma was periodically collected after treatment initiation of voriconazole and repeated during treatment in both groups. The TDM group had measured voriconazole concentrations reported back, with dose adjustments made as appropriate, while the non-TDM group had voriconazole concentrations measured only after study completion. The composite primary endpoint included response to treatment and voriconazole treatment discontinuation due to an adverse drug reaction related to voriconazole within 28 days after treatment initiation. RESULTS: In total, 189 patients were enrolled in the study. For the composite primary endpoint, 74 patients were included in the non-TDM group and 68 patients in the TDM group. Here, no significant difference was found between both groups (P = 0.678). However, more trough concentrations were found within the generally accepted range of 1-6 mg/L for the TDM group (74.0%) compared with the non-TDM group (64.0%) (P < 0.001). CONCLUSIONS: In this trial, TDM-guided dosing of voriconazole did not show improved treatment outcome compared with standard dosing. We believe that these findings should open up the discussion for an approach to voriconazole TDM that includes drug exposure, pathogen susceptibility and host defence. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov registration no. NCT00893555.


Assuntos
Aspergilose , Infecções Fúngicas Invasivas , Humanos , Adolescente , Adulto , Voriconazol/efeitos adversos , Estudos Prospectivos , Antifúngicos/efeitos adversos , Monitoramento de Medicamentos , Estudos Retrospectivos , Aspergilose/tratamento farmacológico , Infecções Fúngicas Invasivas/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA