Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Langmuir ; 37(15): 4639-4646, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33826341

RESUMO

We report the stress-strain effect of a stretchable natural rubber (NR)-calcium phosphate composite on the surface wettability (SW) using an innovative approach coupling a uniaxial tensile micromachine, goniometer, and microscope. In situ contact angle measurements in real time were performed during mechanical tension. Our results show that SW is guided by the stress-strain relationship with two different characteristics, depending on the static or dynamic experiments. The results evidenced the limits of the classical theory of wetting. Furthermore, based on the mechanically tunable SW of the system associated with the cytocompatibility of the NR composite, we have modeled such a system for application as a cell support. From the experimental surface energy value, our proposed 3D modeling numerical simulation predicted a window of opportunities for cell-NR survival under mechanical stimuli. The presented data and the thermodynamics-based theoretical approach enable not only accurate correlation of SW with mechanical properties of the NR composite but also provide huge potential for future cell supportability in view of tissue engineering.

2.
Int J Mol Sci ; 18(10)2017 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-29065466

RESUMO

Maintenance of mesenchymal stem cells (MSCs) requires a tissue-specific microenvironment (i.e., niche), which is poorly represented by the typical plastic substrate used for two-dimensional growth of MSCs in a tissue culture flask. The objective of this study was to address the potential use of collagen-based medical devices (HEMOCOLLAGENE®, Saint-Maur-des-Fossés, France) as mimetic niche for MSCs with the ability to preserve human MSC stemness in vitro. With a chemical composition similar to type I collagen, HEMOCOLLAGENE® foam presented a porous and interconnected structure (>90%) and a relative low elastic modulus of around 60 kPa. Biological studies revealed an apparently inert microenvironment of HEMOCOLLAGENE® foam, where 80% of cultured human MSCs remained viable, adopted a flattened morphology, and maintained their undifferentiated state with basal secretory activity. Thus, three-dimensional HEMOCOLLAGENE® foams present an in vitro model that mimics the MSC niche with the capacity to support viable and quiescent MSCs within a low stiffness collagen I scaffold simulating Wharton's jelly. These results suggest that haemostatic foam may be a useful and versatile carrier for MSC transplantation for regenerative medicine applications.


Assuntos
Microambiente Celular , Colágeno , Células-Tronco Mesenquimais , Preservação Biológica/métodos , Medicina Regenerativa/instrumentação , Humanos
3.
Lasers Med Sci ; 30(7): 1985-90, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25380666

RESUMO

Tendinopathy is a common disease with a variety of treatments and therapies. Laser therapy appears as an alternative treatment. Here, we investigate the effects of laser irradiation in an experimental model of tendinitis induced by collagenase injection on rats' Achilles tendon, verifying its action in important inflammatory markers. Male Wistar rats were used and divided into five groups: control saline (C), non-treated tendinitis (NT) and tendinitis treated with sodium diclofenac (D) or laser (1 J) and (3 J). The tendinitis was induced by collagenase (100 µg/tendon) on the Achilles tendon, which was removed for further analyses. The gene expression for COX-2; TNF-α; IL-6; and IL-10 (RT-PCR) was measured. The laser irradiation (660 nm, 100 mW, 3 J) used in the treatment of the tendinitis induced by collagenase in Achilles tendon in rats was effective in the reduction of important pro-inflammatory markers such as IL-6 and TNF-α, becoming a promising tool for the treatment of tendon diseases.


Assuntos
Tendão do Calcâneo/efeitos da radiação , Expressão Gênica/efeitos da radiação , Terapia com Luz de Baixa Intensidade , Tendinopatia/radioterapia , Tendão do Calcâneo/metabolismo , Tendão do Calcâneo/patologia , Animais , Anti-Inflamatórios não Esteroides/uso terapêutico , Colagenases , Ciclo-Oxigenase 2/genética , Ciclo-Oxigenase 2/metabolismo , Diclofenaco/uso terapêutico , Modelos Animais de Doenças , Interleucina-10/genética , Interleucina-10/metabolismo , Interleucina-6/genética , Interleucina-6/metabolismo , Masculino , Ratos , Ratos Wistar , Tendinopatia/induzido quimicamente , Tendinopatia/metabolismo , Fator de Necrose Tumoral alfa/genética , Fator de Necrose Tumoral alfa/metabolismo
4.
J Mech Behav Biomed Mater ; 160: 106743, 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39307076

RESUMO

Despite major instrumental developments over the last decade, endodontic files are still not infallible. It is well known that NiTi rotary files can break without any visible sign of deformation. Instrument breakage under combined flexion-torsion loading is still common in clinical practice. Unfortunately, breakage of this type of instrument mainly occurs in narrow canals, through pinching in the apical region. When such an incident occurs, the endodontist must adopt a debris retrieval strategy that is both stressful and not guaranteed success. This study proposes a new method for experimental damage detection leading to the fracture of Ni-Ti shape memory alloy endodontic files. It is based on the acoustic emission (AE) technique and mechanical parameters measured in real-time and image analysis. It has been shown that the AE results correlate with the damage observations and torque and force measurements recorded during the tests. Having carried out numerous root canal treatment on resin blocks, it appears that this new detection and analysis technique can be used to analyze and anticipate the first signs of damage leading to endodontic file failure. The technological development of such a method, at the level of the engine itself, associated with the act in service procedure, would constitute a revolution in the field of endodontics.

5.
J Mech Behav Biomed Mater ; 126: 104981, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34915358

RESUMO

Wharton's jelly (WJ) is a mucous connective tissue of the umbilical cord. It shows high healing capabilities, mainly attributed to the chemical composition and to the presence of stem cells, growth factors and peptides. Although WJ biological properties are well documented in vitro and in vivo, there is still a lack of mechanical data on this tissue, which is paramount for its use as a biomaterial for medical applications. In this study, mechanical responses of ten WJ samples within close physiological conditions were registered undergoing quasi static cyclic tensile tests followed by a load up to failure. This protocol aimed on one hand to provide biomechanical data to feed predictive numerical models and on the other hand increase WJ knowledge in view of its potential use in biomedical field. In spite of the WJ harvest, the resulting viscous nonlinear elastic response obtained is fully in tune with the literature confirming the database quality. A side of the knowledge improvement on WJ mechanical response, this paper provides accurate data that will enhance predictive simulation work such as finite element analysis. The mechanical step-through brought by the analytical nonlinear characterization over cyclic and ultimate loads is to predict WJ behavior. Actually, principal component analysis highlighted its quality while pointing out indicators, such as failure or hydration criteria, as well as models' limitations.


Assuntos
Células-Tronco Mesenquimais , Geleia de Wharton , Diferenciação Celular , Proliferação de Células , Células Cultivadas , Humanos , Cordão Umbilical
6.
J Biomech Eng ; 133(6): 065001, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21744936

RESUMO

Tissue engineering offers an interesting alternative to current anterior cruciate ligament (ACL) surgeries. Indeed, a tissue-engineered solution could ideally overcome the long-term complications due to actual ACL reconstruction by being gradually replaced by biological tissue. Key requirements concerning the ideal scaffold for ligament tissue engineering are numerous and concern its mechanical properties, biochemical nature, and morphology. This study is aimed at predicting the morphology of a novel scaffold for ligament tissue engineering, based on multilayer braided biodegradable copoly(lactic acid-co-(e-caprolactone)) (PLCL) fibers The process used to create the scaffold is briefly presented, and the degradations of the material before and after the scaffold processing are compared. The process offers varying parameters, such as the number of layers in the scaffold, the pitch length of the braid, and the fibers' diameter. The prediction of the morphology in terms of pore size distribution and pores interconnectivity as a function of these parameters is performed numerically using an original method based on a virtual scaffold. The virtual scaffold geometry and the prediction of pore size distribution are evaluated by comparison with experimental results. The presented process permits creation of a tailorable scaffold for ligament tissue engineering using basic equipment and from minimum amounts of raw material. The virtual scaffold geometry closely mimics the geometry of real scaffolds, and the prediction of the pore size distribution is found to be in good accordance with measurements on real scaffolds. The scaffold offers an interconnected network of pores the sizes of which are adjustable by playing on the process parameters and are able to match the ideal pore size reported for tissue ingrowth. The adjustability of the presented scaffold could permit its application in both classical ACL reconstructions and anatomical double-bundle reconstructions. The precise knowledge of the scaffold morphology using the virtual scaffold will be useful to interpret the activity of cells once it will be seeded into the scaffold. An interesting perspective of the present work is to perform a similar study aiming at predicting the mechanical response of the scaffold according to the same process parameters, by implanting the virtual scaffold into a finite element algorithm.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirurgia , Engenharia Tecidual , Alicerces Teciduais , Ligamento Cruzado Anterior/fisiopatologia , Materiais Biocompatíveis/química , Fenômenos Biomecânicos , Engenharia Biomédica , Simulação por Computador , Humanos , Poliésteres/química , Alicerces Teciduais/química , Interface Usuário-Computador
7.
J Biomech Eng ; 132(11): 111002, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21034143

RESUMO

Although the mechanical properties of ligament and tendon are well documented in research literature, very few unified mechanical formulations can describe a wide range of different loadings. The aim of this study was to propose a new model, which can describe tendon responses to various solicitations such as cycles of loading, unloading, and reloading or successive relaxations at different strain levels. In this work, experiments with cycles of loading and reloading at increasing strain level and sequences of relaxation were performed on white New Zealand rabbit Achilles tendons. We presented a local formulation of thermodynamic evolution outside equilibrium at a representative element volume scale to describe the tendon's macroscopic behavior based on the notion of relaxed stress. It was shown that the model corresponds quite well to the experimental data. This work concludes with the complexity of tendons' mechanical properties due to various microphysical mechanisms of deformation involved in loading such as the recruitment of collagen fibers, the rearrangement of the microstructure (i.e., collagens type I and III, proteoglycans, and water), and the evolution of relaxed stress linked to these mechanisms.


Assuntos
Tendão do Calcâneo/fisiologia , Modelos Biológicos , Algoritmos , Animais , Fenômenos Biomecânicos , Engenharia Biomédica , Colágeno/fisiologia , Módulo de Elasticidade , Elasticidade , Técnicas In Vitro , Dinâmica não Linear , Coelhos , Estresse Mecânico , Termodinâmica , Viscosidade
8.
Proc Inst Mech Eng H ; 234(3): 265-272, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32126905

RESUMO

The usage of finite element method techniques gives a possibility to replace time-consuming experiments or imitate physical process in the ear by numerical simulation. Especially, the research of spatial motion of ossicular chain in the middle ear is of high interest for the oto-surgeons and engineers. It is known that the most affected bone from the ossicular chain is the incus. After the cholesteatoma operation and tympanoplasty, the affected incus is removed or sacrificed; thus, the possibility of transducing noise lays on the stapes, new titanium or other material prosthesis. In this case, the affected incus was removed because of the cholesteatoma that was lying in front of it in the tympanic cavity. The removed incus with the affected long process passed micro-computed tomography. The computer-aided design systems allowed redesigning a 'healthy' incus with an intact long process. In this way, it was possible to evaluate the influence of damaged long process of incus in the vibrational analysis. This article analyses the problems of mechanical behaviour of injured and healthy human incus. The numerical simulation has demonstrated that the features of healthy incus and analysed injured incus do not differ significantly, especially at low (about 500 Hz) frequencies. It explains why there is no impact of cholesteatoma on hearing for a long time in the audiogram.


Assuntos
Análise de Elementos Finitos , Bigorna/lesões , Fenômenos Mecânicos , Fenômenos Biomecânicos , Humanos , Imageamento Tridimensional , Bigorna/diagnóstico por imagem , Tomografia Computadorizada por Raios X
9.
Biomed Mater Eng ; 18(4-5): 283-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19065035

RESUMO

Bioreactors are defined as devices in which biological and/or biochemical processes develop under closely monitored and tightly controlled environmental and operating conditions (e.g. pH, temperature, mechanical conditions, nutrient supply and waste removal). In functional tissue engineering of musculoskeletal tissues, a bioreactor capable of controlling dynamic loading plays a determinant role. It has been shown that mechanical stretching promotes the expression of type I and III collagens, fibronectin, tenascin-C in cultured ligament fibroblasts (J.C.-H. Goh et al., Tissue Eng. 9 (2003), S31) and that human bone marrow mesenchymal stem cells (hBMMSC) - even in the absence of biochemical regulators - could be induced to differentiate into ligament-like fibroblast by the application of physiologically relevant cyclic strains (G. Vunjak-Novakovic et al., Ann. Rev. Biomed. Eng. 6 (2004), 131; H.A. Awad et al., Tissue Eng. 5 (1999), 267; R.G. Young et al., J. Orthop. Res. 16 (1998), 406). Different bioreactors are commercially available but they are too generic to be used for a given tissue, each tissue showing specific mechanical loading properties. In the case of ligament tissue engineering, the design of a bioreactor is still an open question. Our group proposes a bioreactor allowing cyclic traction-torsion on a scaffold seeded with stem cells.


Assuntos
Reatores Biológicos , Técnicas de Cultura de Células/instrumentação , Ligamentos/citologia , Ligamentos/crescimento & desenvolvimento , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/fisiologia , Engenharia Tecidual/instrumentação , Animais , Técnicas de Cultura de Células/métodos , Diferenciação Celular , Células Cultivadas , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas de Cultura de Órgãos/instrumentação , Técnicas de Cultura de Órgãos/métodos , Ratos , Ratos Wistar , Engenharia Tecidual/métodos
10.
J Biomater Appl ; 32(9): 1276-1288, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29409376

RESUMO

Poly(lactide-co-ε-caprolactone) (PLCL) has been reported to be a good candidate for tissue engineering because of its good biocompatibility. Particularly, a braided PLCL scaffold (PLL/PCL ratio = 85/15) has been recently designed and partially validated for ligament tissue engineering. In the present study, we assessed the in vivo biocompatibility of acellular and cellularised scaffolds in a rat model. We then determined its in vitro biocompatibility using stem cells issued from both bone marrow and Wharton Jelly. From a biological point of view, the scaffold was shown to be suitable for tissue engineering in all these cases. Secondly, while the initial mechanical properties of this scaffold have been previously reported to be adapted to load-bearing applications, we studied the evolution in time of the mechanical properties of PLCL fibres due to hydrolytic degradation. Results for isolated PLCL fibres were extrapolated to the fibrous scaffold using a previously developed numerical model. It was shown that no accumulation of plastic strain was to be expected for a load-bearing application such as anterior cruciate ligament tissue engineering. However, PLCL fibres exhibited a non-expected brittle behaviour after two months. This may involve a potential risk of premature failure of the scaffold, unless tissue growth compensates this change in mechanical properties. This combined study emphasises the need to characterise the properties of biomaterials in a pluridisciplinary approach, since biological and mechanical characterisations led in this case to different conclusions concerning the suitability of this scaffold for load-bearing applications.


Assuntos
Materiais Biocompatíveis/química , Poliésteres/química , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Animais , Células Cultivadas , Humanos , Hidrólise , Teste de Materiais , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Ratos Nus , Resistência à Tração
11.
J Tissue Eng Regen Med ; 12(2): 360-369, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28486755

RESUMO

Scaffolds laden with stem cells are a promising approach for articular cartilage repair. Investigations have shown that implantation of artificial matrices, growth factors or chondrocytes can stimulate cartilage formation, but no existing strategies apply mechanical stimulation on stratified scaffolds to mimic the cartilage environment. The purpose of this study was to adapt a spraying method for stratified cartilage engineering and to stimulate the biosubstitute. Human mesenchymal stem cells from bone marrow were seeded in an alginate (Alg)/hyaluronic acid (HA) or Alg/hydroxyapatite (Hap) gel to direct cartilage and hypertrophic cartilage/subchondral bone differentiation, respectively, in different layers within a single scaffold. Homogeneous or composite stratified scaffolds were cultured for 28 days and cell viability and differentiation were assessed. The heterogeneous scaffold was stimulated daily. The mechanical behaviour of the stratified scaffolds were investigated by plane-strain compression tests. Results showed that the spraying process did not affect cell viability. Moreover, cell differentiation driven by the microenvironment was increased with loading: in the layer with Alg/HA, a specific extracellular matrix of cartilage, composed of glycosaminoglycans and type II collagen was observed, and in the Alg/Hap layer more collagen X was detected. Hap seemed to drive cells to a hypertrophic chondrocytic phenotype and increased mechanical resistance of the scaffold. In conclusion, mechanical stimulations will allow for the production of a stratified biosubstitute, laden with human mesenchymal stem cells from bone marrow, which is capable in vivo to mimic all depths of chondral defects, thanks to an efficient combination of stem cells, biomaterial compositions and mechanical loading.


Assuntos
Diferenciação Celular , Células-Tronco Mesenquimais/citologia , Estresse Mecânico , Alicerces Teciduais/química , Idoso , Alginatos/farmacologia , Materiais Biocompatíveis/farmacologia , Diferenciação Celular/efeitos dos fármacos , Condrogênese/efeitos dos fármacos , Durapatita/farmacologia , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Pessoa de Meia-Idade
12.
Bioengineering (Basel) ; 4(1)2017 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-28952494

RESUMO

Cells respond to their mechanical environment in different ways: while their response in terms of differentiation and proliferation has been widely studied, the question of the direction in which cells align when subject to a complex mechanical loading in a 3D environment is still widely open. In the present paper, we formulate the hypothesis that the cells orientate in the direction of unitary stretch computed from the right Cauchy-Green tensor in a given mechanical environment. The implications of this hypothesis are studied in different simple cases corresponding to either the available in vitro experimental data or physiological conditions, starting from finite element analysis results to computed preferential cellular orientation. The present contribution is a first step to the formulation of a deeper understanding of the orientation of cells within or at the surface of any 3D scaffold subject to any complex load. It is believed that these initial preferential directions have strong implications as far as the anisotropy of biological structures is concerned.

13.
Biomed Mater Eng ; 28(s1): S193-S200, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28372295

RESUMO

Once articular cartilage is damaged, it has poor ability to heal. At present, alginate-based hydrogels have 3D-dimensional physical structures with great potential for applications in carilage tissue engineering. For osteochondral defect, it will be necessary to use stratified scaffold to mimic zonal organization of cartilage. This study aims to compare the characteristics of alginate (Alg)/hyaluronic acid (HA) hydrogels which will mimic cartilage with alginate (Alg)/hydroxyapatite (Hap) hydrogels which will mimic subchondral bone. In this work, we fabricated the 3D-Alg/HA and Alg/Hap hydrogel scaffolds by the original spraying method. From the physical-mechanical properties, we compared mechanical behaviour of Alg/HA and Alg/Hap hydrogel scaffolds, which were examined using indentation testing and viscosity behaviour. This results showed that the Alg/Hap hydrogels exhibited a relative high mechanical strength, as well as the viscosity of Alg/Hap hydrogels is slight slower than Alg/HA hydrogels. However, autoclaving has more deleterious effect on the mechanical and viscosity properties of Alg/HA and Alg/Hap hydrogels. Cytotoxicity was evaluated through the culture of hydrogel beads-laden Wharton's jelly mesenchymal stem cells (WJ-MSC). In addition, the chondrogenic differentiation of WJ-MSC encapsulated into Alg/HA and Alg/Hap hydrogels were performed by histological analyzing during 30 days of culture. From these results, the percentage of living cells for Alg/Hap is significantly higher than Alg/HA, which also is associated with the results of shear viscosity. Both of hydrogels exhibited differentiate into chondrocyte matrix as collagen and proteoglycans. In conclusion, Alg/Hap hydrogels presented better mechanical property, cytocompatibility and differentiation characteristics than Alg/HA hydrogels.


Assuntos
Alginatos/química , Substitutos Ósseos/química , Durapatita/química , Ácido Hialurônico/química , Células-Tronco Mesenquimais/citologia , Geleia de Wharton/citologia , Proliferação de Células , Sobrevivência Celular , Células Cultivadas , Ácido Glucurônico/química , Ácidos Hexurônicos/química , Humanos , Hidrogéis/química , Teste de Materiais , Engenharia Tecidual/métodos , Viscosidade
14.
J Mech Behav Biomed Mater ; 68: 134-143, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28161663

RESUMO

Alginate-based hydrogel scaffolds are widely used in the field of cartilage regeneration and repair. If the effect of autoclaving on the alginate powder is well known, it is not the same for the possible effects of the sterilization UV treatment on the properties of the hydrogel after polymerization. To select an effective sterilization treatment of alginate-based materials, one must find what are inter-relationship between the characteristics (chemical, physical and mechanical) of alginate-based hydrogel during sterilization, and what consequences have affected on cell behavior. In this study, we investigated the influence of UV sterilization treatments (UV-1 and UV-2: 25 and 50min, respectively) and autoclaving to obtain alginate (Alg)/hyaluronic acid (HA) hydrogel, as well as further evaluated the relationship between physicochemical properties and cell behavior of Alg/HA hydrogel after UVs and autoclaving. The physicochemical properties of this mixture at the powder or polymerized states were analyzed using ATR-FTIR, HPLC-SEC, rheological, indentation testing and sterility testing. The cell behaviors of hydrogels were evaluated by cell viability and proliferation, and chondrogenic differentiation. The effects of treatment parameters and their correlation with the others characteristics were determined statistically by Principal Component Analysis (PCA). In this study, we have shown that the cell behavior in alginate-based hydrogels was not only regulated by physicochemical properties (as molar mass or/and viscosity), but also associated with the controlling of sterilization time. It can provide a basis for choosing an effective method of sterilization, which can keep the mechanical or physical-chemical properties of Alg-based hydrogel scaffold and maintain its cytocompatibility and its ability to induce chondrogenesis from mesenchymal stem cells.


Assuntos
Alginatos/química , Condrogênese , Hidrogéis/química , Células-Tronco Mesenquimais/citologia , Esterilização , Diferenciação Celular , Proliferação de Células , Sobrevivência Celular , Células Cultivadas , Ácido Glucurônico/química , Ácidos Hexurônicos/química , Humanos
15.
Stem Cell Res Ther ; 8(1): 161, 2017 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-28676126

RESUMO

BACKGROUND: The umbilical cord is becoming a notable alternative to bone marrow (BM) as a source of mesenchymal stromal cells (MSC). Although age-dependent variations in BM-MSC are well described, less data are available for MSC isolated from Wharton's jelly (WJ-MSC). We initiated a study to identify whether obstetric factors influenced MSC properties. We aimed to evaluate the correlation between a large number of obstetric factors collected during pregnancy and until peripartum (related to the mother, the labor and delivery, and the newborn) with WJ-MSC proliferation and chondrogenic differentiation parameters. METHODS: Correlations were made between 27 obstetric factors and 8 biological indicators including doubling time at passage (P)1 and P2, the percentage of proteoglycans and collagens, and the relative transcriptional expression of Sox-9, aggrecans, and total type 2 collagen (Coll2T). RESULTS: Amongst the obstetric factors considered, birth weight, the number of amenorrhea weeks, placental weight, normal pregnancy, and the absence of preeclampsia were identified as relevant factors for cell expansion, using multivariate linear regression analysis. Since all the above parameters are related to term, we concluded that WJ-MSC from healthy, full-term infants exhibit greater proliferation capacity. As for chondrogenesis, we also observed that obstetric factors influencing proliferation seemed beneficial, with no negative impact on MSC differentiation. CONCLUSIONS: Awareness of obstetric factors influencing the proliferation and/or differentiation of WJ-MSC will make it possible to define criteria for collecting optimal umbilical cords with the aim of decreasing the variability of WJ-MSC batches produced for clinical use in cell and tissue engineering.


Assuntos
Amenorreia , Peso ao Nascer , Diferenciação Celular , Proliferação de Células , Condrogênese , Células-Tronco Mesenquimais/metabolismo , Cordão Umbilical/metabolismo , Adulto , Colágeno Tipo II/metabolismo , Feminino , Humanos , Células-Tronco Mesenquimais/citologia , Gravidez , Fatores de Risco , Fatores de Transcrição SOX9/metabolismo , Cordão Umbilical/citologia
16.
J Mech Behav Biomed Mater ; 29: 272-85, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24126100

RESUMO

For three decades, low level laser therapy (LLLT) has been used for treatment of tendinitis as well as other musculoskeletal diseases. Nevertheless, the biological mechanisms involved remain not completely understood. In this work, the effects of LLLT and of the widely used nonsteroidal anti-inflammatory drug, diclofenac, have been compared in the case of collagenase-induced Achilles tendinitis. Wistar rats were treated with diclofenac or laser therapy. The tensile behavior of tendons was characterized through successive loading-unloading sequences. The method considered 11 characteristic parameters to describe the mechanical behavior. It was shown that during the acute inflammatory process of the tendon, the mechanical properties were significantly correlated to the high levels of MMP-3, MMP-9 and MMP-13 expression presented in a previous paper (Marcos, R.L., et al., 2012). The treatment by non-steroidal anti-inflammatory drugs such as diclofenac sodium produces a low protective effect and can affect the short-term biochemical and biomechanical properties. On the contrary, it is shown that LLLT exhibits the best results in terms of MMPs reduction and mechanical properties recovery. Thus, LLLT looks to be a promising and consistent treatment for tendinopathies.


Assuntos
Tendão do Calcâneo/efeitos da radiação , Terapia com Luz de Baixa Intensidade , Fenômenos Mecânicos , Tendinopatia/radioterapia , Tendão do Calcâneo/metabolismo , Animais , Fenômenos Biomecânicos/efeitos da radiação , Regulação Enzimológica da Expressão Gênica/efeitos da radiação , Masculino , Metaloproteinases da Matriz/metabolismo , Ratos , Ratos Wistar
17.
J Mech Behav Biomed Mater ; 40: 222-233, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25243672

RESUMO

The use of biodegradable scaffolds seeded with cells in order to regenerate functional tissue-engineered substitutes offers interesting alternative to common medical approaches for ligament repair. Particularly, finite element (FE) method enables the ability to predict and optimise both the macroscopic behaviour of these scaffolds and the local mechanic signals that control the cell activity. In this study, we investigate the ability of a dedicated FE code to predict the geometrical evolution of a new braided and biodegradable polymer scaffold for ligament tissue engineering by comparing scaffold geometries issued from FE simulations and from X-ray tomographic imaging during a tensile test. Moreover, we compare two types of FE simulations the initial geometries of which are issued either from X-ray imaging or from a computed idealised configuration. We report that the dedicated FE simulations from an idealised reference configuration can be reasonably used in the future to predict the global and local mechanical behaviour of the braided scaffold. A valuable and original dialog between the fields of experimental and numerical characterisation of such fibrous media is thus achieved. In the future, this approach should enable to improve accurate characterisation of local and global behaviour of tissue-engineering scaffolds.


Assuntos
Materiais Biocompatíveis , Ligamentos , Teste de Materiais , Alicerces Teciduais , Fenômenos Biomecânicos , Análise de Elementos Finitos , Polímeros , Engenharia Tecidual/métodos , Tomografia por Raios X
18.
J Mech Behav Biomed Mater ; 12: 184-96, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22836026

RESUMO

An adapted scaffold for Anterior Cruciate Ligament (ACL) tissue engineering must match biological, morphological and biomechanical requirements. Computer-aided tissue engineering consists of finding the most appropriate scaffold regarding a specific application by using numerical tools. In the present study, the biomechanical behavior of a new multilayer braided scaffold adapted to computer-aided tissue engineering is computed by using a dedicated Finite Element (FE) code. Among different copoly(lactic acid-co-(ε-caprolactone)) (PLCL) fibers tested in the present study, PLCL fibers with a lactic acid/ε-caprolactone ratio of 85/15 were selected as a constitutive material for the scaffold considering its strength and deformability. The mechanical behavior of these fibers was utilized as material input in a Finite Element (FE) code which considers contact/friction interactions between fibers within a large deformation framework. An initial geometry issued from the braiding process was then computed and was found to be representative of the actual scaffold geometry. Comparisons between simulated tensile tests and experimental data show that the method enables to predict the tensile response of the multilayer braided scaffold as a function of different process parameters. As a result, the present approach constitutes a valuable tool in order to determine the configuration which best fits the biomechanical requirements needed to restore the knee function during the rehabilitation period. The developed approach also allows the mechanical stimuli due to external loading to be quantified, and will be used to perform further mechanobiological analyses of the scaffold under dynamic culture.


Assuntos
Ligamento Cruzado Anterior/fisiopatologia , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Algoritmos , Ligamento Cruzado Anterior/fisiologia , Materiais Biocompatíveis/química , Fenômenos Biomecânicos , Caproatos/química , Simulação por Computador , Humanos , Joelho/fisiopatologia , Lactonas/química , Teste de Materiais , Polímeros/química , Software , Estresse Mecânico , Resistência à Tração
19.
J Orthop Res ; 30(12): 1945-51, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22674405

RESUMO

NSAIDs are widely prescribed and used over the years to treat tendon injuries despite its well-known long-term side effects. In the last years several animal and human trials have shown that low-level laser therapy (LLLT) presents modulatory effects on inflammatory markers, however the mechanisms involved are not fully understood. The aim of this study was to evaluate the short-term effects of LLLT or sodium diclofenac treatments on biochemical markers and biomechanical properties of inflamed Achilles tendons. Wistar rats Achilles tendons (n = 6/group) were injected with saline (control) or collagenase at peritendinous area of Achilles tendons. After 1 h animals were treated with two different doses of LLLT (810 nm, 1 and 3 J) at the sites of the injections, or with intramuscular sodium diclofenac. Regarding biochemical analyses, LLLT significantly decreased (p < 0.05) COX-2, TNF-α, MMP-3, MMP-9, and MMP-13 gene expression, as well as prostaglandin E(2) (PGE(2) ) production when compared to collagenase group. Interestingly, diclofenac treatment only decreased PGE(2) levels. Biomechanical properties were preserved in the laser-treated groups when compared to collagenase and diclofenac groups. We conclude that LLLT was able to reduce tendon inflammation and to preserve tendon resistance and elasticity.


Assuntos
Tendão do Calcâneo/patologia , Colagenases/metabolismo , Terapia com Luz de Baixa Intensidade/métodos , Tendinopatia/radioterapia , Animais , Anti-Inflamatórios não Esteroides/farmacologia , Bioquímica/métodos , Fenômenos Biomecânicos , Colagenases/química , Ciclo-Oxigenase 2/metabolismo , Diclofenaco/farmacologia , Dinoprostona/metabolismo , Inflamação , Masculino , Metaloproteinases da Matriz/biossíntese , Ratos , Ratos Wistar , Tendinopatia/etiologia , Fator de Necrose Tumoral alfa/biossíntese
20.
J Biomater Sci Polym Ed ; 21(13): 1737-60, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20557686

RESUMO

We have designed a composite scaffold for potential use in tendon or ligament tissue engineering. The composite scaffold was made of a cellularized alginate gel that encapsulated a knitted structure. Our hypothesis was that the alginate would act as a cell carrier and deliver cells to the injury site while the knitted structure would provide mechanical strength to the composite construct. The mechanical behaviour and the degradation profile of the poly(lactic-co-glycolic acid) knitted scaffolds were evaluated. We found that our scaffolds had an elastic modulus of 750 MPa and that they lost their physical integrity within 7 weeks of in vitro incubation. Autologous rabbit mesenchymal stem cell seeded composite scaffolds were implanted in a 1-cm-long defect created in the rabbit tendon, and the biomechanical properties and the morphology of the regenerated tissues were evaluated after 13 weeks. The regenerated tendons presented higher normalized elastic modulus of (60%) when compared with naturally healed tendons (40%). The histological study showed a higher cell density and vascularization in the regenerated tendons.


Assuntos
Tendão do Calcâneo/citologia , Tendão do Calcâneo/efeitos dos fármacos , Ácido Láctico/química , Ácido Láctico/farmacologia , Ácido Poliglicólico/química , Ácido Poliglicólico/farmacologia , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Tendão do Calcâneo/metabolismo , Tendão do Calcâneo/fisiologia , Alginatos/química , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Feminino , Ácido Glucurônico/química , Ácidos Hexurônicos/química , Concentração de Íons de Hidrogênio , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Coelhos , Regeneração/efeitos dos fármacos , Resistência à Tração/efeitos dos fármacos , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA