Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Prosthet Dent ; 128(4): 688-694, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33750574

RESUMO

STATEMENT OF PROBLEM: Although the 2D analysis of prosthesis cementation space has been popular, its correlation with volumetric comparison (3D data) of cement space is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the cement space in computer-aided design and computer-aided manufacturing (CAD-CAM) crowns of different materials and correlate 2D measurements of cement space with their corresponding 3D values (volume of cement space) by using microcomputed tomography (µCT) analysis of regions of interest. MATERIAL AND METHODS: Ten molar crowns were milled in lithium disilicate (LD), resin nanoceramic (RN), and zirconia (Z) ceramics. Silicone replicas were produced and used as the analog cement layer and scanned with a desktop X-ray microfocus CT scanner. Twenty-eight slices were evaluated in 3 regions: marginal, axial, and occlusal (n=84 measurement points/specimen). After 3D reconstruction of the cement space, the volume was calculated. Data were statistically evaluated through 2-way ANOVA and Bonferroni test (α=.05). The Pearson correlation test was used to investigate the correlation between the 2D and 3D data. RESULTS: The volumes of the occlusal (LD 10 ±1 mm3; RN 9 ±1 mm3) and axial regions (LD 9 ±2 mm3; RN 8 ±1 mm3) were significantly higher than the volume of the marginal region for LD and RN specimens (LD 6 ±2 mm3; RN 4 ±1 mm3) (both P<.001). For the Z group, the axial region had the highest volume (19 ±2 mm3), followed by the volumes of the occlusal (15 ±1 mm3) and marginal regions (12 ±1 mm3). The Pearson correlation test determined a moderate positive correlation of the marginal area (r=0.606, P<.001) and of the axial region (r=0.588, P<.001). However, a moderate negative correlation was found between volume and thickness of the occlusal area (r=-0.437, P=.016). CONCLUSIONS: Z showed more volume of cement space, as well as thicker cement space than LD and RN. The µCT analysis is an efficient method of analyzing cement thickness and volume in ceramic crowns at the selected regions of interest. A moderate positive correlation was found between the 2D and 3D analyses for the axial and marginal regions of ceramic crowns.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Microtomografia por Raio-X , Coroas , Desenho Assistido por Computador , Porcelana Dentária , Materiais Dentários , Cerâmica , Cimentos Dentários/uso terapêutico , Cimentos de Ionômeros de Vidro
2.
J Prosthet Dent ; 124(1): 87.e1-87.e6, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32238276

RESUMO

STATEMENT OF PROBLEM: Identical computer-aided design (CAD) parameters may be used to mill a variety of ceramic materials for computer-aided design and computer-aided manufacture (CAD-CAM) crowns. Whether milled crown spacing matches the designed parameters when more than a single evaluation method is applied is unknown. PURPOSE: The purpose of this in vitro study was to correlate the stereomicroscope and the microcomputer tomography (µCT) 2-dimensional analysis of the cementation space with the replica technique in assessing 3 different ceramic materials. MATERIAL AND METHODS: The specimens were milled in lithium disilicate, resin nanoceramic, and zirconia (n=30). The cement space was measured at the marginal, axial, and occlusal regions. One hundred twenty measurements of each material were used to correlate the methodologies. Data were statistically evaluated with 2-way repeated measures ANOVA and the Tukey test (α=.05). The Pearson correlation coefficient was used for each region for both methodologies (µCT and optical microscopy) separately. RESULTS: For the µCT analysis, no differences were observed (P>.05) among the materials, but the axial region showed a positive correlation with the marginal (r=0.957) and occlusal regions (r=0.349); the same was observed between the occlusal and marginal regions (r=0.338). However, for stereomicroscope evaluation, resin nanoceramic and zirconia present similar cementation space (P=960), both being different from lithium disilicate (P<.05). The marginal region presented a positive correlation with axial (r=0.149) and occlusal regions (r=0.344), but the axial region showed negative correlation with the occlusal surface (r=-0.205). CONCLUSIONS: The measurements of the scanned replicas were accurate when thinner sections were under measurement. Although the same space parameters were set in the CAD software program, definitive internal dimensions varied among the milled crowns.


Assuntos
Cimentação , Adaptação Marginal Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária
3.
J Prosthodont ; 28(2): e552-e556, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29961986

RESUMO

PURPOSE: To evaluate the pullout resistance of CAD/CAM implant-supported crowns cemented with provisional and definitive cements on Ti-base implant abutments. MATERIALS AND METHODS: Sixty crowns were milled for use in Ti-base implant abutments and divided (n = 15/group) according to material, as follows: (a) [Pr] Temporary acrylic resin; (b) [Co-Cr] Cobalt-Chromium alloy; (c) [Zr] polycrystalline zirconia; and (d) [Ti] titanium. The cementation was performed with RelyX Temp NE (RxT) cement or RelyX U200 self-etching resin cement, under a 50 N (5 kg) load for 10 minutes. Twenty-four hours after cementation, the crowns were subjected to the pullout test in a universal test machine, at a 1.0 mm/min crosshead speed. The tests were performed first without cement to evaluate frictional resistance (Baseline), then with provisional cement (RelyX Temp NE without cement again (Baseline After RxT), and finally with resin cement (U200). The results were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: Data evaluation as a function of cement type demonstrated the superiority of resin-based cements relative to provisional and baseline groups (p < 0.01). While Co-Cr crowns presented the highest pullout strength values, Pr showed the lowest values (data collapsed over cement) (p < 0.001). Retentiveness data as a function of both factors demonstrated similar pullout resistance between groups without cement (p < 0.001), except Zr baseline. Also, Co-Cr presented higher pullout strength compared to other materials. CONCLUSIONS: Self-adhesive resin cement exhibited superior retention compared to temporary cement, regardless of crown material. Co-Cr and titanium presented higher levels of retention to Ti-base abutment after being cemented.


Assuntos
Cimentação/métodos , Desenho Assistido por Computador , Coroas , Dente Suporte , Materiais Dentários/química , Ligas de Cromo/química , Teste de Materiais , Cimentos de Resina/química , Titânio/química , Zircônio/química
4.
ACS Biomater Sci Eng ; 10(5): 3097-3107, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38591966

RESUMO

To develop a peri-implantitis model in a Gottingen minipig and evaluate the effect of local application of salicylic acid poly(anhydride-ester) (SAPAE) on peri-implantitis progression in healthy, metabolic syndrome (MS), and type-2 diabetes mellitus (T2DM) subjects. Eighteen animals were allocated to three groups: (i) control, (ii) MS (diet for obesity induction), and (iii) T2DM (diet plus streptozotocin for T2DM induction). Maxillary and mandible premolars and first molar were extracted. After 3 months of healing, four implants per side were placed in both jaws of each animal. After 2 months, peri-implantitis was induced by plaque formation using silk ligatures. SAPAE polymer was mixed with mineral oil (3.75 mg/µL) and topically applied biweekly for up to 60 days to halt peri-implantitis progression. Periodontal probing was used to assess pocket depth over time, followed by histomorphologic analysis of harvested samples. The adopted protocol resulted in the onset of peri-implantitis, with healthy minipigs taking twice as long to reach the same level of probing depth relative to MS and T2DM subjects (∼3.0 mm), irrespective of jaw. In a qualitative analysis, SAPAE therapy revealed decreased levels of inflammation in the normoglycemic, MS, and T2DM groups. SAPAE application around implants significantly reduced the progression of peri-implantitis after ∼15 days of therapy, with ∼30% lower probing depth for all systemic conditions and similar rates of probing depth increase per week between the control and SAPAE groups. MS and T2DM conditions presented a faster progression of the peri-implant pocket depth. SAPAE treatment reduced peri-implantitis progression in healthy, MS, and T2DM groups.


Assuntos
Peri-Implantite , Ácido Salicílico , Porco Miniatura , Animais , Suínos , Peri-Implantite/tratamento farmacológico , Peri-Implantite/patologia , Ácido Salicílico/administração & dosagem , Ácido Salicílico/farmacologia , Ácido Salicílico/uso terapêutico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Modelos Animais de Doenças , Progressão da Doença , Hiperglicemia/tratamento farmacológico , Masculino , Diabetes Mellitus Experimental/tratamento farmacológico , Síndrome Metabólica/tratamento farmacológico , Síndrome Metabólica/metabolismo , Implantes Dentários
5.
J Appl Oral Sci ; 28: e20200343, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33263647

RESUMO

OBJECTIVE: An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (µCT). METHODOLOGY: Volumetric and linear (central and marginal) gaps of four Ti-base abutments (n=10/group): (i) Odontofix LTDA (OD), (ii) Singular Implants (SING), (iii) EFF Dental Components (EFF), and (iv) Control Group (S.I.N implants) compatible with an implant system (Strong SW, S.I.N Implants) were measured using µCT reconstructed polyvinyl siloxane replicas. RESULTS: The results showed significantly lower volume gap for Control S.I.N (0.67±0.29 mm3) and SING (0.69±0.28 mm3) Ti-base abutments relative to OD (1.42±0.28 mm3) and EFF groups (1.04±0.28 mm3) (p<0.033), without significant difference between them (p=0.936). While gap values were homogenous in the central region, EFF presented a significantly higher marginal gap. Accordingly, the Control S.I.N and Singular Ti-base abutments showed improved volumetric and marginal fit relative to Odontofix and EFF. CONCLUSION: The method of manufacturing abutments influenced the misfit at the implant-abutment interface.


Assuntos
Dente Suporte , Implantes Dentários , Projeto do Implante Dentário-Pivô , Técnicas de Réplica , Titânio , Microtomografia por Raio-X
6.
J Appl Oral Sci ; 27: e20180351, 2019 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-31365707

RESUMO

OBJECTIVE: Since the transmittance of ceramics can influence the degree of conversion (DC) of resin cements, ceramics composition and shade should be considered in the selection of resin cement. This in vitro study aimed to evaluate the effect of the transmittance of different composition, opacities and shades of ceramics on the degree of conversion of two dual-cured resin cements. METHODOLOGY: Sixty discs were prepared from low translucency (LT) and medium opacity (MO) lithium disilicate ceramic, and zirconia ceramic (Z). Each group was subdivided into 5 subgroups (n=4) in shades A2, A3.5, B2, C2 and D3. The transmittance measurement was performed in a spectrophotometer. The Variolink II and Rely X U200 resin cements were photoactivated by LED (1400 mW/cm2) for 40 s through the ceramic discs and without the discs (control group). The DC was measured with infrared FTIR spectroscopy, immediately after light activation. Data were analyzed with Kruskall-Wallis and one-way ANOVA, following post-hoc comparisons by Tukey test and Pearson's correlation test (P<0.05). RESULTS: LT ceramic exhibited higher transmittance values compared to MO and Z ceramics. LTA2 and LTB2 showed statistically higher transmittance values compared to MOA2, MOA3.5 and ZA3.5. For Variolink II, the ceramic interposition did not influence the DC, since there were no statistical differences between groups with ceramic interposition and the control group. For Rely X U200 cement, the interposition of some ceramics types/shades (LTA3.5, MOA2, MOA3.5 and ZA3.5) significantly decreased the DC values compared to control group. A positive correlation was found between the ceramic transmittance and DC values of both tested cements. Conclusions. The transmittance and DC values of the cements were influenced by composition and shades of the ceramics. The higher the transmittance of ceramics, the higher the DC values for both cements.


Assuntos
Porcelana Dentária/química , Cimentos de Resina/química , Zircônio/química , Análise de Variância , Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Transição de Fase , Polimerização , Valores de Referência , Reprodutibilidade dos Testes , Espectrofotometria/métodos , Estatísticas não Paramétricas
7.
J. appl. oral sci ; 28: e20200343, 2020. graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1143144

RESUMO

Abstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology: Volumetric and linear (central and marginal) gaps of four Ti-base abutments (n=10/group): (i) Odontofix LTDA (OD), (ii) Singular Implants (SING), (iii) EFF Dental Components (EFF), and (iv) Control Group (S.I.N implants) compatible with an implant system (Strong SW, S.I.N Implants) were measured using μCT reconstructed polyvinyl siloxane replicas. Results: The results showed significantly lower volume gap for Control S.I.N (0.67±0.29 mm3) and SING (0.69±0.28 mm3) Ti-base abutments relative to OD (1.42±0.28 mm3) and EFF groups (1.04±0.28 mm3) (p<0.033), without significant difference between them (p=0.936). While gap values were homogenous in the central region, EFF presented a significantly higher marginal gap. Accordingly, the Control S.I.N and Singular Ti-base abutments showed improved volumetric and marginal fit relative to Odontofix and EFF. Conclusion: The method of manufacturing abutments influenced the misfit at the implant-abutment interface.


Assuntos
Implantes Dentários , Dente Suporte , Titânio , Técnicas de Réplica , Microtomografia por Raio-X , Projeto do Implante Dentário-Pivô
8.
J. appl. oral sci ; 27: e20180351, 2019. graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1012511

RESUMO

Abstract Objective Since the transmittance of ceramics can influence the degree of conversion (DC) of resin cements, ceramics composition and shade should be considered in the selection of resin cement. This in vitro study aimed to evaluate the effect of the transmittance of different composition, opacities and shades of ceramics on the degree of conversion of two dual-cured resin cements. Methodology Sixty discs were prepared from low translucency (LT) and medium opacity (MO) lithium disilicate ceramic, and zirconia ceramic (Z). Each group was subdivided into 5 subgroups (n=4) in shades A2, A3.5, B2, C2 and D3. The transmittance measurement was performed in a spectrophotometer. The Variolink II and Rely X U200 resin cements were photoactivated by LED (1400 mW/cm2) for 40 s through the ceramic discs and without the discs (control group). The DC was measured with infrared FTIR spectroscopy, immediately after light activation. Data were analyzed with Kruskall-Wallis and one-way ANOVA, following post-hoc comparisons by Tukey test and Pearson's correlation test (P<0.05). Results LT ceramic exhibited higher transmittance values compared to MO and Z ceramics. LTA2 and LTB2 showed statistically higher transmittance values compared to MOA2, MOA3.5 and ZA3.5. For Variolink II, the ceramic interposition did not influence the DC, since there were no statistical differences between groups with ceramic interposition and the control group. For Rely X U200 cement, the interposition of some ceramics types/shades (LTA3.5, MOA2, MOA3.5 and ZA3.5) significantly decreased the DC values compared to control group. A positive correlation was found between the ceramic transmittance and DC values of both tested cements. Conclusions. The transmittance and DC values of the cements were influenced by composition and shades of the ceramics. The higher the transmittance of ceramics, the higher the DC values for both cements.


Assuntos
Zircônio/química , Cimentos de Resina/química , Porcelana Dentária/química , Valores de Referência , Espectrofotometria/métodos , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Transição de Fase , Cura Luminosa de Adesivos Dentários , Lâmpadas de Polimerização Dentária , Polimerização
9.
Perionews ; 8(6): 550-555, nov.-dez. 2014. ilus
Artigo em Português | LILACS | ID: lil-743259

RESUMO

As recessões gengivais são encontradas com bastante frequência na população, gerando, em muitos casos, incômodo estético. Sensibilidade radicular também tem sido relatada, além de maior predisposição à cárie e às lesões não cariosas de abrasão e erosão na superfície radicular desnuda. A fim de alcançar um recobrimento radicular satisfatório, muitas técnicas têm sido propostas, dentre elas os enxertos gengivais livres, enxertos gengivais pediculados ou a associação de ambos. O presente artigo teve por objetivo relatar um caso clínico de recobrimento radicular através da técnica de deslize lateral do retalho associada ao enxerto de tecido conjuntivo subepitelial. O acompanhamento clínico ao longo de um ano mostrou a ocorrência de creeping attachment.


The gingival recessions are found very frequently in the population, generating in many cases, aesthetic complaint. Root sensitivity has also been reported, beyond greater predisposition to caries and non-carious lesions of abrasion and erosion on the denuded root surface. In order to achieve satisfactory root coverage, many techniques have been proposed, among them the free gingival grafts, pedicled gingival grafts or a combination of both. This article aims to report a case of root coverage using the technique of laterally positioned flap associated with the subepithelial connective tissue graft. The one-year clinical follow-up showed the occurrence of creeping attachment.


Assuntos
Humanos , Adulto , Tecido Conjuntivo , Retração Gengival , Gengiva/cirurgia , Periodontia , Transplante de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA