Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Adv Model Earth Syst ; 14(4): e2021MS002699, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35860306

RESUMO

The Hamburg Aerosol Module version 2.3 (HAM2.3) from the ECHAM6.3-HAM2.3 global atmosphere-aerosol model is coupled to the recently developed icosahedral nonhydrostatic ICON-A (icon-aes-1.3.00) global atmosphere model to yield the new ICON-A-HAM2.3 atmosphere-aerosol model. The ICON-A and ECHAM6.3 host models use different dynamical cores, parameterizations of vertical mixing due to sub-grid scale turbulence, and parameter settings for radiation balance tuning. Here, we study the role of the different host models for simulated aerosol optical thickness (AOT) and evaluate impacts of using HAM2.3 and the ECHAM6-HAM2.3 two-moment cloud microphysics scheme on several meteorological variables. Sensitivity runs show that a positive AOT bias over the subtropical oceans is remedied in ICON-A-HAM2.3 because of a different default setting of a parameter in the moist convection parameterization of the host models. The global mean AOT is biased low compared to MODIS satellite instrument retrievals in ICON-A-HAM2.3 and ECHAM6.3-HAM2.3, but the bias is larger in ICON-A-HAM2.3 because negative AOT biases over the Amazon, the African rain forest, and the northern Indian Ocean are no longer compensated by high biases over the sub-tropical oceans. ICON-A-HAM2.3 shows a moderate improvement with respect to AOT observations at AERONET sites. A multivariable bias score combining biases of several meteorological variables into a single number is larger in ICON-A-HAM2.3 compared to standard ICON-A and standard ECHAM6.3. In the tropics, this multivariable bias is of similar magnitude in ICON-A-HAM2.3 and in ECHAM6.3-HAM2.3. In the extra-tropics, a smaller multivariable bias is found for ICON-A-HAM2.3 than for ECHAM6.3-HAM2.3.

2.
Parkinsonism Relat Disord ; 8(4): 277-84, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12039423

RESUMO

BACKGROUND: Autonomic dysfunction occurs in Parkinson's disease (PD), but few studies have addressed it in a comprehensive manner. METHODS: Autonomic symptoms were evaluated by a questionnaire in sixty-eight subjects (44 patients and 24 controls). RESULTS: PD patients experienced higher frequency and severity of autonomic dysfunction. When all autonomic symptoms were pooled into an aggregate score, differences between patients and controls were highly statistically significant (p<0.0001). 'Increased salivation', 'frequency of dysphagia', decreased 'BM (bowel movement) frequency', i.e. constipation, and 'orthostatic dizziness' were more frequent in PD patients (p<0.05). A prediction model to determine the predictors of autonomic dysfunction was unsuccessful. CONCLUSION: Differences in the prevalence of autonomic symptoms in PD and non-parkinsonian controls are apparent from this study.


Assuntos
Doenças do Sistema Nervoso Autônomo/etiologia , Doença de Parkinson/complicações , Idoso , Doenças do Sistema Nervoso Autônomo/epidemiologia , Doenças do Sistema Nervoso Autônomo/fisiopatologia , Feminino , Gastroenteropatias/epidemiologia , Gastroenteropatias/etiologia , Inquéritos Epidemiológicos , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/fisiopatologia , Prevalência , Valores de Referência , Análise de Regressão , Índice de Gravidade de Doença
3.
Rev Sci Instrum ; 82(2): 023705, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21361599

RESUMO

A noncontact atomic force microscope (nc-AFM) operating in magnetic fields up to ±7 T and liquid helium temperatures is presented in this article. In many common AFM experiments the cantilever is mounted parallel to the sample surface, while in our system the cantilever is assembled perpendicular to it; the so called pendulum mode of AFM operation. In this mode measurements employing very soft and, therefore, ultrasensitive cantilevers can be performed. The ultrahigh vacuum conditions allow to prepare and transfer cantilevers and samples in a requested manner avoiding surface contamination. We demonstrate the possibility of nc-AFM and Kelvin force probe microscopy imaging in the pendulum mode. Ultrasensitive experiments on small spin ensembles are presented as well.

4.
Nanotechnology ; 17(7): S189-94, 2006 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-21727413

RESUMO

Force microscopy experiments with the pendulum geometry are performed with attonewton sensitivity (Rugar et al 2004 Nature 43 329). Single-crystalline cantilevers with sub-millinewton spring constants were annealed under ultrahigh-vacuum conditions. It is found that annealing with temperatures below 500 °C can improve the quality factor by an order of magnitude. The high force sensitivity of these ultrasoft cantilevers is used to characterize small magnetic and superconductive particles, which are mounted on the end of the cantilever. Their magnetic properties are analysed in magnetic fields as a function of temperature. The transition of a superconducting sample mounted on a cantilever is measured by the detection of frequency shifts. An increase of dissipation is observed below the critical temperature. The magnetic moment of ferromagnetic particles is determined by real time frequency detection with a phase-locked loop (PLL) as a function of the magnetic field. The dissipation between the probing tip and the sample is another important ingredient for ultrasensitive force measurements. It is found that dissipation increases at separations of 30 nm. The origins of this type of dissipation are poorly understood. However, it is predicted theoretically that adsorbates can increase this dissipation channel (Volokitin and Persson 2005 Phys. Rev. Lett. 94 086104). First experiments are performed under ultrahigh vacuum to investigate this type of dissipation. Long-range dissipation is closely related to long-range forces. The distance dependence of the contact potential is found to be an important aspect.

5.
Environ Sci Technol ; 40(11): 3586-94, 2006 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-16786698

RESUMO

Air quality, ecosystem exposure to nitrogen deposition, and climate change are intimately coupled problems: we assess changes in the global atmospheric environment between 2000 and 2030 using 26 state-of-the-art global atmospheric chemistry models and three different emissions scenarios. The first (CLE) scenario reflects implementation of current air quality legislation around the world, while the second (MFR) represents a more optimistic case in which all currently feasible technologies are applied to achieve maximum emission reductions. We contrast these scenarios with the more pessimistic IPCC SRES A2 scenario. Ensemble simulations for the year 2000 are consistent among models and show a reasonable agreement with surface ozone, wet deposition, and NO2 satellite observations. Large parts of the world are currently exposed to high ozone concentrations and high deposition of nitrogen to ecosystems. By 2030, global surface ozone is calculated to increase globally by 1.5 +/- 1.2 ppb (CLE) and 4.3 +/- 2.2 ppb (A2), using the ensemble mean model results and associated +/-1 sigma standard deviations. Only the progressive MFR scenario will reduce ozone, by -2.3 +/- 1.1 ppb. Climate change is expected to modify surface ozone by -0.8 +/- 0.6 ppb, with larger decreases over sea than over land. Radiative forcing by ozone increases by 63 +/- 15 and 155 +/- 37 mW m(-2) for CLE and A2, respectively, and decreases by -45 +/- 15 mW m(-2) for MFR. We compute that at present 10.1% of the global natural terrestrial ecosystems are exposed to nitrogen deposition above a critical load of 1 g N m(-2) yr(-1). These percentages increase by 2030 to 15.8% (CLE), 10.5% (MFR), and 25% (A2). This study shows the importance of enforcing current worldwide air quality legislation and the major benefits of going further. Nonattainment of these air quality policy objectives, such as expressed by the SRES-A2 scenario, would further degrade the global atmospheric environment.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/prevenção & controle , Atmosfera/análise , Monitoramento Ambiental/métodos , Animais , Ecologia/métodos , Ecologia/tendências , Ecossistema , Previsões , Efeito Estufa , Humanos , Nitrogênio/análise , Ozônio/análise
6.
J Am Chem Soc ; 123(11): 2637-44, 2001 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-11456933

RESUMO

For the first time, a very general theoretical method is proposed to interpret the full electron paramagnetic resonance (EPR) spectra at multiple temperatures and frequencies in the important case of S-state metal ions complexed in liquid solution. This method is illustrated by a careful analysis of the measured spectra of two Gd3+ (S = 7/2) complexes. It is shown that the electronic relaxation mechanisms at the origin of the EPR line shape arise from the combined effects of the modulation of the static crystal field by the random Brownian rotation of the complex and of the transient zero-field splitting. A detailed study of the static crystal field mechanism shows that, contrarily to the usual global models involving only second-order terms, the fourth and sixth order terms can play a non-negligible role. The obtained parameters are well interpreted in the framework of the physics of the various underlying relaxation processes. A better understanding of these mechanisms is highly valuable since they partly control the efficiency of paramagnetic metal ions in contrast agents for medical magnetic resonance imaging (MRI).


Assuntos
Gadolínio/química , Imageamento por Ressonância Magnética , Cristalização , Espectroscopia de Ressonância de Spin Eletrônica , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA