RESUMO
Serological testing of large representative populations for antibodies to SARS-CoV-2 is needed to estimate seroprevalence, transmission dynamics, and the duration of antibody responses from natural infection and vaccination. In this study, a high-throughput SARS-CoV-2 multiplex microsphere immunoassay (MMIA) was developed for the receptor binding domain (RBD) and nucleocapsid (N) that was more sensitive than enzyme-linked immunosorbent assay (ELISA) (98% versus 87%). The MMIA was then applied and validated in 264 first responders in Colorado using serum and dried blood spot (DBS) eluates, compared to ELISA, and evaluated for neutralizing antibodies. Four percent (11/264) of first responders were seropositive in July to August 2020. Serum and DBS were highly correlated for anti-RBD and anti-N antibodies (R = 0.83, P < 0.0001 and R = 0.87, P < 0.0001, respectively) by MMIA. The MMIA accurately predicted SARS-CoV-2 neutralizing antibodies using DBS (R = 0.76, P = 0.037). On repeat antibody testing 3 months later, anti-RBD IgG decreased less rapidly than anti-N IgG measured by MMIA, with a median change in geometric median fluorescence intensity of 62% versus 79% (P < 0.01) for anti-RBD and anti-N IgG, respectively. This novel MMIA using DBS could be scalable for rapid and affordable SARS-CoV-2 serosurveillance in the United States and globally.
Assuntos
COVID-19 , Socorristas , Anticorpos Antivirais , Teste Sorológico para COVID-19 , Colorado , Humanos , Imunoensaio , Microesferas , SARS-CoV-2 , Estudos SoroepidemiológicosRESUMO
The impact of B cell deficiency on the humoral and cellular responses to SARS-CoV2 mRNA vaccination remains a challenging and significant clinical management question. We evaluated vaccine-elicited serological and cellular responses in 1) healthy individuals who were pre-exposed to SARS-CoV-2 (n = 21), 2) healthy individuals who received a homologous booster (mRNA, n = 19; or Novavax, n = 19), and 3) persons with multiple sclerosis on B cell depletion therapy (MS-αCD20) receiving mRNA homologous boosting (n = 36). Pre-exposure increased humoral and CD4 T cellular responses in immunocompetent individuals. Novavax homologous boosting induced a significantly more robust serological response than mRNA boosting. MS-α CD20 had an intact IgA mucosal response and an enhanced CD8 T cell response to mRNA boosting compared with immunocompetent individuals. This enhanced cellular response was characterized by the expansion of only effector, not memory, T cells. The enhancement of CD8 T cells in the setting of B cell depletion suggests a regulatory mechanism between B and CD8 T cell vaccine responses.
Assuntos
COVID-19 , Esclerose Múltipla , Humanos , Vacinas contra COVID-19 , RNA Viral , COVID-19/prevenção & controle , SARS-CoV-2 , RNA MensageiroRESUMO
Background: There is little information on cell-mediated immunity (CMI) to COVID-19 mRNA vaccines in children. We studied adaptive and innate CMI in vaccinated children aged 6 to 60 months. Methods: Blood obtained from participants in a randomized placebo-controlled trial of an mRNA vaccine before and 1 month after the first dose was used for antibody measurements and CMI (flow cytometry). Results: We enrolled 29 children with a mean age of 28.5 months (SD, 15.7). Antibody studies revealed that 10 participants were infected with SARS-CoV-2 prevaccination. Ex vivo stimulation of peripheral blood mononuclear cells with SARS-CoV-2 spike peptides showed significant increases pre- to postimmunization of activated conventional CD4+ and γδ T cells, natural killer cells, monocytes, and conventional dendritic cells but not mucosa-associated innate T cells. Conventional T-cell, monocyte, and conventional dendritic cell responses in children were higher immediately after vaccination than after SARS-CoV-2 infection. The fold increase in CMI pre- to postvaccination did not differ between children previously infected with SARS-CoV-2 and those uninfected. Conclusions: Children aged 6 to 60 months who were vaccinated with a COVID-19 mRNA vaccine developed robust CMI responses, including adaptive and innate immunity.
RESUMO
Emerging evidence is encouraging and suggests that a substantial proportion of patients without antibody responses (due to anti-CD20 therapy or other etiologies) to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) vaccines develop T cell responses. However, antigen-specific T cellular responses are notoriously difficult to assess clinically, given the lack of such assays under satisfactory CAP/CLIA regulation, and the laborious nature of the flow cytometric assessment. To evaluate the ability to apply a clinically feasible assay to measure T cellular responses to SARS-CoV-2 mRNA vaccination, we compared flow cytometric and enzyme-linked immunosorbent assay (ELISA) based assays in 24 participants treated with anti-CD20 therapy. T cellular activation (CD69 + CD137+ surface expression, i.e., activation induced markers [AIM]) and intracellular interferon gamma (INFγ) production via flow cytometry was compared to plasma Interferon Gamma Release Assay (IGRA) via ELISA. Plasma INFγ production measured by IGRA correlated with the percent of INFγ-producing AIM positive T cells, supporting the use of IGRA assay as a robust assessment of T cellular response to the SARS-CoV-2 vaccine for B-cell depleted patients that is clinically feasible, time efficient, and cost effective.
Assuntos
Vacinas contra COVID-19 , COVID-19 , Interferon gama , Linfócitos T , Humanos , Anticorpos Antivirais , COVID-19/prevenção & controle , Vacinas contra COVID-19/imunologia , Interferon gama/imunologia , SARS-CoV-2 , Linfócitos T/imunologia , Linfócitos BRESUMO
Many aspects of innate immune responses to SARS viruses remain unclear. Of particular interest is the role of emerging neutralizing antibodies against the receptor-binding domain (RBD) of SARS-CoV-2 in complement activation and opsonization. To overcome challenges with purified virions, here we introduce "pseudovirus-like" nanoparticles with â¼70 copies of functional recombinant RBD to map complement responses. Nanoparticles fix complement in an RBD-dependent manner in sera of all vaccinated, convalescent, and naiÌve donors, but vaccinated and convalescent donors with the highest levels of anti-RBD antibodies show significantly higher IgG binding and higher deposition of the third complement protein (C3). The opsonization via anti-RBD antibodies is not an efficient process: on average, each bound antibody promotes binding of less than one C3 molecule. C3 deposition is exclusively through the alternative pathway. C3 molecules bind to protein deposits, but not IgG, on the nanoparticle surface. Lastly, "pseudovirus-like" nanoparticles promote complement-dependent uptake by granulocytes and monocytes in the blood of vaccinated donors with high anti-RBD titers. Using nanoparticles displaying SARS-CoV-2 proteins, we demonstrate subject-dependent differences in complement opsonization and immune recognition.
RESUMO
Background: There is an urgent need for harmonization between severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology platforms and assays prior to defining appropriate correlates of protection and as well inform the development of new rapid diagnostic tests that can be used for serosurveillance as new variants of concern (VOC) emerge. We compared multiple SARS-CoV-2 serology reference materials to the WHO International Standard (WHO IS) to determine their utility as secondary standards, using an international network of laboratories with high-throughput quantitative serology assays. This enabled the comparison of quantitative results between multiple serology platforms. Methods: Between April and December 2020, 13 well-characterized and validated SARS-CoV-2 serology reference materials were recruited from six different providers to qualify as secondary standards to the WHO IS. All the samples were tested in parallel with the National Institute for Biological Standards and Control (NIBSC) 20/136 and parallel-line assays were used to calculate the relevant potency and binding antibody units. Results: All the samples saw varying levels of concordance between diagnostic methods at specific antigen-antibody combinations. Seven of the 12 candidate materials had high concordance for the spike-immunoglobulin G (IgG) analyte [percent coefficient of variation (%CV) between 5 and 44%]. Conclusion: Despite some concordance between laboratories, qualification of secondary materials to the WHO IS using arbitrary international units or binding antibody units per milliliter (BAU/ml) does not provide any benefit to the reference materials overall, due to the lack of consistent agreeable international unit (IU) or BAU/ml conversions between laboratories. Secondary standards should be qualified to well-characterized reference materials, such as the WHO IS, using serology assays that are similar to the ones used for the original characterization of the WHO IS.