Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Eur Radiol ; 30(10): 5272-5280, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32385650

RESUMO

OBJECTIVES: To compare speed of sound (SoS) ultrasound (US) of the calves with Dixon magnetic resonance imaging (MRI) for fat content quantification. MATERIALS AND METHODS: The study was approved by the local ethics committee. Fifty calf muscles of 35 women (age range 22-81 years) prospectively underwent an US and subsequent MRI (Dixon sequence) examination as well as body weight and impedance fat measurements. SoS (in m/s) was calculated positioning a reflector on the opposite side of a conventional US machine probe with the calf in between. Fiducial nitroglycerin markers were placed on the calf at the reflector and US probe end positions for later registration of the US sonification volumetric section. An automatic segmentation algorithm separated MRI adipose tissue, muscle and bone regions. MRI fat fraction of the entire leg slice (total) and intramuscular and adipose tissue fat fraction were calculated and correlation analysis and correlation coefficient comparison were performed. RESULTS: Median SoS demonstrated a very strong (r = - 0.83 (95% CI - 0.90; - 0.72); p < 0.001) correlation with MRI total fat fraction, a strong (r = - 0.61 (95% CI - 0.76; - 0.40); p < 0.001) correlation with MRI adipose tissue fat fraction and a moderate (r = - 0.54 (95% CI - 0.71; - 0.31); p < 0.001) correlation with MRI intramuscular fat fraction. Impedance body fat percentage correlated strongly with SoS (r = - 0.72 (95% CI - 0.85; - 0.51); p < 0.001) and MRI total fat fraction (r = 0.61 (95% CI 0.34; 0.78); p < 0.001). For electrical impedance, significantly lower correlations (p = 0.033) were found for MRI total fat fraction compared with SoS. CONCLUSIONS: Correlations of SoS with Dixon MRI fat fraction measurements were very strong to moderate. KEY POINTS: • Correlations of speed of sound with Dixon MRI fat fraction measurements of the same body location were very strong to moderate. • Speed of sound measurements showed a high repeatability. • Speed of sound provides a sufficient discrimination range for fat fraction estimates.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Algoritmos , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Bovinos , Feminino , Humanos , Extremidade Inferior , Masculino , Pessoa de Meia-Idade , Prótons , Adulto Jovem
2.
Eur Radiol ; 29(1): 3-12, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30324383

RESUMO

OBJECTIVES: To measure speed of sound (SoS) with a novel hand-held ultrasound technique as a quantitative indicator for muscle loss and fatty muscular degeneration. METHODS: Both calf muscles of 11 healthy, young females (mean age 29 years), and 10 elderly females (mean age 82 years) were prospectively examined with a standard ultrasound machine. A flat Plexiglas® reflector, on the opposite side of the probe with the calf in between, was used as timing reference for SoS (m/s) and ΔSoS (variation of SoS, m/s). Handgrip strength (kPA), Tegner activity scores, and 5-point comfort score (1 = comfortable to 5 = never again) were also assessed. Ultrasound parameters (muscle/adipose thickness, echo intensity) were measured for comparison. RESULTS: Both calves were assessed in less than two minutes. All measurements were successful. The elderly females showed significantly lower SoS (1516 m/s, SD17) compared to the young adults (1545 m/s, SD10; p < 0.01). The ΔSoS of elderly females was significantly higher (12.2 m/s, SD3.6) than for young females (6.4 m/s, SD1.5; p < 0.01). Significant correlations of SoS with hand grip strength (r = 0.644) and Tegner activity score (rs = 0.709) were found, of similar magnitude as the correlation of hand grip strength with Tegner activity score (rs = 0.794). The average comfort score of the elderly was 1.1 and for the young adults 1.4. SoS senior/young classification (AUC = 0.936) was superior to conventional US parameters. CONCLUSIONS: There were significant differences of SoS and ΔSoS between young and elderly females. Measurements were fast and well tolerated. The novel technique shows potential for sarcopenia quantification using a standard ultrasound machine. KEY POINTS: • Speed of sound ultrasound: a novel technique to identify sarcopenia in seniors. • Measurements were fast and well tolerated using a standard ultrasound machine. • The novel technique shows potential for sarcopenia quantification.


Assuntos
Força da Mão/fisiologia , Músculo Esquelético/diagnóstico por imagem , Sarcopenia/diagnóstico , Ultrassonografia/métodos , Adulto , Idoso de 80 Anos ou mais , Animais , Bovinos , Feminino , Humanos , Masculino , Músculo Esquelético/fisiopatologia , Projetos Piloto , Sarcopenia/fisiopatologia
3.
Eur Radiol ; 28(8): 3165-3175, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29556766

RESUMO

OBJECTIVES: To assess feasibility and diagnostic accuracy of a novel hand-held ultrasound (US) method for breast density assessment that measures the speed of sound (SoS), in comparison to the ACR mammographic (MG) categories. METHODS: ACR-MG density (a=fatty to d=extremely dense) and SoS-US were assessed in the retromamillary, inner and outer segments of 106 women by two radiographers. A conventional US system was used for SoS-US. A reflector served as timing reference for US signals transmitted through the breasts. Four blinded readers assessed average SoS (m/s), ΔSoS (segment-variation SoS; m/s) and the ACR-MG density. The highest SoS and ΔSoS values of the three segments were used for MG-ACR whole breast comparison. RESULTS: SoS-US breasts were examined in <2 min. Mean SoS values of densities a-d were 1,421 m/s (SD 14), 1,432 m/s (SD 17), 1,448 m/s (SD 20) and 1,500 m/s (SD 31), with significant differences between all groups (p<0.001). The SoS-US comfort scores and inter-reader agreement were significantly better than those for MG (1.05 vs. 2.05 and 0.982 vs. 0.774; respectively). A strong segment correlation between SoS and ACR-MG breast density was evident (rs=0.622, p=<0.001) and increased for full breast classification (rs=0.746, p=<0.001). SoS-US allowed diagnosis of dense breasts (ACR c and d) with sensitivity 86.2 %, specificity 85.2 % and AUC 0.887. CONCLUSIONS: Using hand-held SoS-US, radiographers measured breast density without discomfort, readers evaluated measurements with high inter-reader agreement, and SoS-US correlated significantly with ACR-MG breast-density categories. KEY POINTS: • The novel speed-of-sound ultrasound correlated significantly with mammographic ACR breast density categories. • Radiographers measured breast density without women discomfort or radiation. • SoS-US can be implemented on a standard US machine. • SoS-US shows potential for a quantifiable, cost-effective assessment of breast density.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Densidade da Mama , Neoplasias da Mama/patologia , Detecção Precoce de Câncer , Desenho de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade , Ultrassonografia Mamária/instrumentação
4.
Knee Surg Sports Traumatol Arthrosc ; 23(7): 1929-35, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24711104

RESUMO

PURPOSE: Meniscal injury resulting in segmental loss of meniscal tissue is a major risk factor for the development of osteoarthritis. Tissue engineering strategies have provided scaffolds for meniscal regeneration in order to establish a treatment option for patients with limited opportunities for meniscal reconstruction. The purpose of this study was to assess the clinical and magnetic resonance imaging (MRI) results 2 years after implantation of a polyurethane scaffold for chronic segmental medial meniscus deficiency following partial medial meniscectomy. METHODS: Eighteen patients were treated with arthroscopic implantation of an ActiFit(®) (Orteq Sports Medicine) polyurethane meniscal scaffold for meniscus deficiency of the medial meniscus. Patients were followed up at 6, 12, and 24 months. Clinical outcome was assessed using patient-reported outcome scores (KOOS, KSS, UCLA activity scale, VAS for pain). Radiological outcome was assessed using MRI at 6, 12, and 24 months by evaluating scaffold morphology, scaffold integration, and additional joint injury, as well as joint inflammation. RESULTS: Eighteen patients with a median age of 32.5 years (range 17-49) were enrolled. Statistically significant improvements were present in all patients, but one at 2 years compared to baseline in all categories. Complete resorption of the scaffold occurred in one patient representing a failure to treatment. MRI showed abnormal signal intensity of the scaffold when compared to residual meniscal tissue but without synovitis or joint inflammation. Extrusion of the scaffold was present in four patients. No correlation between scaffold extrusion and clinical outcome was observed. CONCLUSION: Arthroscopic implantation of a polyurethane meniscal scaffold in patients with chronic segmental medial meniscus deficiency is not only a safe procedure but leads to good clinical results at a 2-year follow-up. Scaffold extrusion did not appear to affect clinical outcome. LEVEL OF EVIDENCE: IV.


Assuntos
Articulação do Joelho/cirurgia , Meniscos Tibiais/cirurgia , Lesões do Menisco Tibial , Alicerces Teciduais , Adolescente , Adulto , Artroplastia de Substituição , Artroscopia , Humanos , Prótese Articular , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Poliuretanos , Resultado do Tratamento , Adulto Jovem
5.
Knee Surg Sports Traumatol Arthrosc ; 22(11): 2623-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23545586

RESUMO

PURPOSE: The aim of the present study was to retrospectively investigate the development of patellofemoral osteoarthritis after the historical Insall's proximal realignment for patellar stabilisation in patients with recurrent patellar dislocation. Furthermore, risk factors for recurrent patellar dislocation and for patellofemoral osteoarthritis development were evaluated. METHODS: Forty-two patients underwent patellofemoral stabilising surgery by the historic Insall's proximal realignment; they were evaluated with a mean follow-up period of 52 months. Plain radiography was used to document osteoarthritic changes by using the Iwano classification. MRIs obtained at the latest follow-up were evaluated for patellofemoral cartilage lesions. Univariate and multivariate logistic regression analyses were performed to evaluate the influence of trochlear dysplasia, tibial tubercle-trochlear groove distance and patellar height on redislocation. Pearson's χ (2) and the Spearman's correlation tests were used to assess a possible correlation between trochlear dysplasia and patellar dislocation, as well as between instability and development of patellofemoral osteoarthritis. RESULTS: At the latest follow-up, plain radiographs showed a significant increase in patellofemoral osteoarthritis (grades II-IV according to the Iwano classification) in 18 patients (43%) compared with 4 patients (10%) at the time of surgery (P = 0.001). Patellofemoral cartilage lesions (grades II-IV) were detected in 18 patients (43 %) on MRI. Nine patients (21%) had at least one incidence of redislocation at follow-up. Estimated redislocation-associated risk factors could not be determined. Trochlear dysplasia had a significant impact on patellofemoral osteoarthritis development (P = 0.001), whereas recurrent patellar instability had none (n.s.). CONCLUSION: Insall's proximal realignment technique leads to a significant progression of patellofemoral osteoarthritis. No risk factors for redislocation could be found; however, the presence of trochlear dysplasia did correlate with patellofemoral osteoarthritis. LEVEL OF EVIDENCE: IV.


Assuntos
Instabilidade Articular/cirurgia , Osteoartrite do Joelho/cirurgia , Luxação Patelar/cirurgia , Articulação Patelofemoral/cirurgia , Adolescente , Adulto , Feminino , Humanos , Articulação do Joelho/cirurgia , Masculino , Patela/cirurgia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
6.
Knee Surg Sports Traumatol Arthrosc ; 22(6): 1270-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24196573

RESUMO

PURPOSE: Articular cartilage defects of the knee are a common condition for which several repair techniques have been described. The aim of the present study was to assess medium-term results of a one-step procedure using a cell-free collagen type I matrix. METHODS: Fifteen patients with articular cartilage defects of the knee were treated with an 11-mm-diameter cell-free collagen type 1 matrix implant. The matrices were implanted in a press-fit manner into the defect after careful debridement down to the subchondral bone but without penetration of this margin. Follow-up examinations were carried out at 6 weeks, 6 months, and at 12, 24, 36, and 48 months after implantation. Clinical assessment included the visual analogue scale (VAS), the Tegner activity scale, and the International Knee Documentation Committee (IKDC) score. Radiological assessment for graft attachment and tissue regeneration was performed using the magnetic observation of cartilage repair tissue (MOCART) score. RESULTS: A total of 15 patients (males: n = 6 and females: n = 9) with a mean age of 26.4 years (range 19-40) were treated. The mean VAS improved significantly when compared to the preoperative values (P < 0.05). Six weeks after implantation, IKDC values were slightly lower than the preoperative values (n.s.), but increased significantly at final follow-up (P < 0.05). At 24 months, there were no significant differences in the median Tegner score between the post-operative values and the preoperative values (n.s.). However, after 36 months, a significant improvement was noted that lasted at least up to 48 months (P < 0.05). The MOCART score improved consistently up to 4 years after implantation, with significant improvements already observed after 12 months (P < 0.05). No correlation between the clinical scores and the MOCART score could be perceived. CONCLUSION: The present study showed that the use of cell-free collagen type I matrix implants led to a significant and durable improvement in all the clinical and imaging scores investigated 4 years after implantation. LEVEL OF EVIDENCE: IV.


Assuntos
Doenças das Cartilagens/cirurgia , Colágeno Tipo I/administração & dosagem , Articulação do Joelho/cirurgia , Adulto , Cartilagem Articular/cirurgia , Matriz Extracelular , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Próteses e Implantes , Resultado do Tratamento , Cicatrização , Adulto Jovem
7.
Diagnostics (Basel) ; 14(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38337786

RESUMO

There have been studies showing attenuation imaging (ATI) with ultrasound as an approach to diagnose liver diseases such as steatosis or cirrhosis. So far, this technique has only been used on a convex probe. The goal of the study was to investigate the feasibility of ATI measurements using the linear array on a canon Aplio i800 scanner on certified phantoms. Three certified liver tissue attenuation phantoms were measured in five different positions using a linear probe. The effects of positioning and depth were explored and compared. The values were compared to the certified expected value for each phantom as well as the different measurement values for each measurement position. The ATI measurements on phantoms showed significant effect for the different probe positions and region of interest (ROI) depths. Values taken in the center with the probe perpendicular to the phantom were closest to certified values. Median values at 2.5-4.5 cm depth for phantoms 1 and 2 and 0.5-2.5 cm for phantom 3 were comparable with certified values. Measurements taken at a depth greater than 6 cm in any position were the least representative of the certified values (p-value < 0.01) and had the widest range throughout the different sessions. ATI measurements can be performed with the linear probe in phantoms; however, careful consideration should be given to depth dependency, as it can significantly affect measurement values. Remaining measurements at various depths within the 0.5-6.0 cm range showed deviation from the certified values of approximately 25%.

8.
Diagnostics (Basel) ; 14(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38732301

RESUMO

The study aimed to investigate the feasibility of attenuation imaging (ATI) measurements using a linear probe on healthy volunteers and compare measurements with the conventional convex probe. Attenuation imaging measurements of the liver tissue were taken using ultrasound with a convex and a linear probe in 33 volunteers by two examining doctors, and the measurements were repeated 4-5 weeks later by one of them. The ATI values for the linear probe were in the range of the values for the convex probe for both examiners. Measurements did not change significantly for 32 out of 33 volunteers after 4-5 weeks when using the linear probe. The size of the region of interest (ROI) only impacted the ATI values for the convex probe; it did not affect the values taken with the linear probe. Healthy volunteers were measured, and their attenuation values were compared to those from a convex probe, commonly used in steatosis evaluation. When both probes were positioned in the same liver area, they showed good agreement in attenuation values, though depth significantly affected the measurements, with both probes providing different values at different depths. The study's results aligned with previous research using the same system. Operator A and B's results were compared, demonstrating similar ranges of values for both probes. The linear probe has been demonstrated to allow for superficial measurements and attain ATI values in line with that of the convex probe in the liver.

9.
Heart Fail Rev ; 18(3): 289-306, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22446985

RESUMO

Although echocardiography remains the standard diagnostic tool for identifying pericardial diseases, procedures with better delineation of morphology and heart function are often required. The pericardium consists of an inner visceral (epicardium) and outer parietal layer (pericardium), which constitute for the pericardial cavity. Pericardial effusion can occur as transudate, exudate, pyopneumopericardium, or hemopericardium. Potential causes are inflammatory processes, that is, pericarditis due to autoimmune or infective reasons, neoplasms, irradiation, or systemic disorders, chronic renal failure, endocrine, or metabolic diseases. Pericardial fat can mimic pericardial effusion. Using various image-acquisition sequences, MRI allows identifying and separating fluid and solid structures. Fast spin-echo T1-weighted sequences with black-blood preparation are favourably used for morphological evaluation. Fast spin-echo T2-weighted sequences, particularly with fat saturation, and short-tau inversion-recovery sequences are useful to visualize oedema and inflammation. For further tissue characterization, delayed inversion-recovery imaging is used. Therefore, image acquisition is performed at 5-20 min subsequent to contrast agent administration, the so-called technique of late gadolinium enhancement. Ventricular volumes and myocardial mass can be assessed accurately by steady-state free-precession sequences, which is required to measure cardiac function and ventricular wall stress. Constrictive pericarditis usually results from chronic inflammatory processes leading to increased stiffness, which impedes the slippage of both pericardial layers and thereby the normal cardiac filling. CT imaging can favourably assess pericardial calcification. Thus, MR and CT imaging allow a comprehensive delineation of the pericardium. Superior to echocardiography, both methods provide a larger field of view and depiction of the complete chest including abnormalities of the surrounding mediastinum and lungs. PET provides unique information on the in vivo metabolism of 18-fluorodeoxyglucose that can be superimposed on CT findings and is useful for identifying inflammatory processes or masses, for example neoplasms. These imaging techniques provide advanced information of anatomy and cardiac function to optimize the pericardial access, for example by the AttachLifter system, for diagnosis and treatment.


Assuntos
Cardiopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Diagnóstico Diferencial , Exsudatos e Transudatos/diagnóstico por imagem , Gadolínio , Cardiopatias/etiologia , Cardiopatias/fisiopatologia , Humanos , Inflamação , Pericardiocentese/métodos , Pericárdio/patologia , Pericárdio/fisiopatologia , Índice de Gravidade de Doença
10.
BMC Surg ; 13: 11, 2013 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-23590134

RESUMO

BACKGROUND: Chondral defects of the articular surface are a common condition that can lead to osteoarthritis if not treated. Therapy of this condition is a topic of constant debate and a variety of chondral repair strategies are currently used. One strategy involves implantation of a cell-free matrix of type I collagen (COL1), to provide a scaffold for chondrocyte migration and proliferation and extracellular matrix production. Although several studies have suggested that chondrocytes can move, to the best of our knowledge there is still no proof of chondrocyte occurrence in a former cell-free scaffold for articular cartilage repair in humans. CASE PRESENTATION: An 18-year-old male patient underwent arthroscopic surgery of the knee for patellar instability and a chondral defect of the femoral condyle. Clinical outcome scores were recorded pre-operatively, after 6 weeks and after 6, 12, 24 and 36 months. MRI was recorded after 6 weeks and after 6, 12, 24 and 36 months postoperatively. At 42 months after implantation of a cell-free type I collagen matrix and reconstruction of the medial patellofemoral ligament, the patient was again treated arthroscopically for a tear of the medial meniscus of the same knee. A biopsy of the previous chondral defect was taken during arthroscopy for histological examination. CONCLUSION: In addition to good clinical and radiological results reported for cell-free scaffolds for cartilage repair in several other studies, transformation of the scaffold could be observed during re-arthroscopy for the meniscal tear. Histological examination of the specimen revealed articular cartilage with vital chondrocytes and a strong staining reaction for type II collagen (COL II), but no reaction for type I collagen staining. This might indicate a complete transformation of the scaffold and supports the theory that cell free scaffolds could support cell migration. Although the cell source remains unclear, migrating chondrocytes from the periphery remain a possibility.


Assuntos
Artroscopia/métodos , Doenças das Cartilagens/cirurgia , Condrócitos/transplante , Adolescente , Doenças das Cartilagens/metabolismo , Doenças das Cartilagens/patologia , Movimento Celular/fisiologia , Sistema Livre de Células/metabolismo , Sistema Livre de Células/patologia , Condrócitos/citologia , Condrócitos/metabolismo , Colágeno Tipo I/administração & dosagem , Colágeno Tipo I/metabolismo , Humanos , Imageamento por Ressonância Magnética , Masculino , Resultado do Tratamento
11.
Can Assoc Radiol J ; 64(4): 333-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23298860

RESUMO

PURPOSE: To assess the occurrence and positive predictive value of additional nonmass findings to stratify the risk of breast microcalcifications. METHODS: This retrospective evaluation included 278 lesions with vacuum- or image-guided hook-wire biopsy for suspicious microcalcifications. The lesions were categorized into exclusive microcalcifications and microcalcifications with focal asymmetry, tubular density or architectural distortion (ie, nonmass findings). To evaluate the utility of additional nonmass findings for risk stratification, outcome variables were positive predictive values and odds ratios for malignancy and invasive carcinoma. RESULTS: Forty-five of 278 microcalcification lesions (16%) were associated with nonmass findings: 28 focal asymmetries, 2 tubular densities, and 15 focal asymmetries in conjunction with tubular densities. Architectural distortion was observed in 28 of these cases. The odds ratio for additional nonmass findings relative to exclusive microcalcifications was 5.9 and was statistically significant (P < .00001). Architectural distortion was the most specific indicator for malignancy and invasiveness, with odds ratios of 6.5 (P = .0072) and 5.6 (P = .0214), respectively. CONCLUSIONS: Microcalcifications with nonmass findings were less frequent than exclusive microcalcifications but were more predictive for malignancy. Architectural distortion demonstrated the highest risk of malignancy and invasiveness. Assessment of additional nonmass findings might be useful for further risk stratification of microcalcifications, indications for additional imaging, and pretreatment considerations.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Mamografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/patologia , Neoplasias da Mama/patologia , Calcinose/patologia , Carcinoma Intraductal não Infiltrante/patologia , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Estudos Retrospectivos , Risco
12.
Diagnostics (Basel) ; 13(5)2023 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-36900133

RESUMO

OBJECTIVES: Measurement location and patient state can impact noninvasive liver assessment and change clinical staging in ultrasound examinations. Research into differences exists for Shear Wave Speed (SWS) and Attenuation Imaging (ATI), but not for Shear Wave Dispersion (SWD). The aim of this study is to assess the effect of breathing phase, liver lobe, and prandial state on SWS, SWD, and ATI ultrasound measurements. METHODS: Two experienced examiners performed SWS, SWD, and ATI measurements in 20 healthy volunteers using a Canon Aplio i800 system. Measurements were taken in the recommended condition (right lobe, following expiration, fasting state), as well as (a) following inspiration, (b) in the left lobe, and (c) in a nonfasting state. RESULTS: SWS and SWD measurements were strongly correlated (r = 0.805, p < 0.001). Mean SWS was 1.34 ± 0.13 m/s in the recommended measurement position and did not change significantly under any condition. Mean SWD was 10.81 ± 2.05 m/s/kHz in the standard condition and significantly increased to 12.18 ± 1.41 m/s/kHz in the left lobe. Individual SWD measurements in the left lobe also had the highest average coefficient of variation (19.68%). No significant differences were found for ATI. CONCLUSION: Breathing and prandial state did not significantly affect SWS, SWD, and ATI values. SWS and SWD measurements were strongly correlated. SWD measurements in the left lobe showed a higher individual measurement variability. Interobserver agreement was moderate to good.

13.
Knee Surg Sports Traumatol Arthrosc ; 20(10): 1915-22, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22095486

RESUMO

PURPOSE: Several well-described techniques are available for the treatment of chondral and osteochondral defects. The aim of the study was to assess the efficacy of a single-stage procedure incorporating a new cell-free collagen type I gel for the treatment of small chondral and osteochondral defects in the knee evaluated at 2-year follow-up. METHODS: Fifteen patients were treated with a cell-free collagen type I gel matrix of 11 mm diameter. The grafts were implanted in the debrided cartilage defect and fixed by press-fit only. The clinical outcome was assessed preoperatively and at 6 weeks, and 6, 12 and 24 months after surgery using the International Knee Documentation Committee (IKDC) score, Tegner activity scale and visual analogue scale (VAS). Graft attachment rate was assessed 6 weeks postoperatively using magnetic resonance imaging (MRI). Cartilage regeneration was evaluated using the Magnetic Observation of Cartilage Repair Tissue (MOCART) score at 6, 12 and 24 months after implantation. Clinical results were correlated with MRI findings. RESULTS: Six male and nine female patients were included in this study, with a mean age of 26 (range: 19-40). No complications were reported. The mean VAS values after 6 weeks and the mean IKDC patient values after 6 months were significantly improved from the preoperative values (P = 0.005 and P = 0.009, respectively). This improvement remained up to the latest follow-up. There were no significant differences between the median preoperative and postoperative Tegner values (n.s.). Significant improvement of the mean MOCART score was observed after 12 months and remained by 24 months (P < 0.001). MR images showed that in 14 of the 15 patients, the graft was completely attached by 6 weeks postoperatively. At 24 months after implantation, MRI demonstrated complete filling in all cases with a mainly smooth surface, complete integration of the border zone, homogenous structure of the repaired tissue and nearly normal signal intensity. No correlation between any variables of the MOCART score and the clinical scores was observed. CONCLUSIONS: The present study reveals that the new method produces both good clinical and magnetic resonance imaging results. Use of press-fit only implanted grafts of a smaller diameter leads to a high attachment rate at 24-month follow-up. LEVEL OF EVIDENCE: IV.


Assuntos
Cartilagem Articular/lesões , Colágeno Tipo I/uso terapêutico , Regeneração Tecidual Guiada/métodos , Traumatismos do Joelho/cirurgia , Alicerces Teciduais , Adulto , Cartilagem Articular/fisiologia , Cartilagem Articular/cirurgia , Sistema Livre de Células , Feminino , Seguimentos , Géis , Humanos , Traumatismos do Joelho/reabilitação , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Resultado do Tratamento , Cicatrização
14.
Artigo em Inglês | MEDLINE | ID: mdl-35797323

RESUMO

The velocity of ultrasound longitudinal waves (speed of sound) is emerging as a valuable biomarker for a wide range of diseases, including musculoskeletal disorders. Muscles are fiber-rich tissues that exhibit anisotropic behavior, meaning that velocities vary with the wave-propagation direction. Therefore, quantifying anisotropy is essential to improve velocity estimates while providing a new metric related to muscle composition and architecture. For the first time, this work presents a method to estimate speed-of-sound anisotropy in transversely isotropic tissues using pulse-echo ultrasound. We assume elliptical anisotropy and consider an experimental setup with a flat reflector parallel to the linear probe, with the muscle in between. This setup allows us to measure first-arrival reflection traveltimes using multistatic operation. Unknown muscle parameters are the orientation angle of the anisotropy symmetry axis and the velocities along and across this axis. We derive analytical expressions for the nonlinear relationship between traveltimes and anisotropy parameters, including reflector inclinations. These equations are exact for homogeneous media and are useful to estimate the effective average anisotropy in muscles. To analyze the structure of this forward problem, we formulate the inversion statistically using the Bayesian framework. We demonstrate that anisotropy parameters can be uniquely constrained by combining traveltimes from different reflector inclinations. Numerical results from wide-ranging acquisition and anisotropy properties show that uncertainties in velocity estimates are substantially lower than expected velocity differences in the muscle. Thus, our approach could provide meaningful muscle anisotropy estimates in future clinical applications.


Assuntos
Anisotropia , Músculos , Ultrassonografia , Teorema de Bayes , Técnicas de Imagem por Elasticidade/métodos
16.
Quant Imaging Med Surg ; 11(9): 4149-4161, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34476195

RESUMO

BACKGROUND: The purpose of this study was threefold: (I) to study the correlation of speed-of-sound (SoS) and shear-wave-speed (SWS) ultrasound (US) in the gastrocnemius muscle, (II) to use reproducible tissue compression to characterize tissue nonlinearity effects, and (III) to compare the potential of SoS and SWS for tissue composition assessment. METHODS: Twenty gastrocnemius muscles of 10 healthy young subjects (age range, 23-34 years, two females and eight males) were prospectively examined with both clinical SWS (GE Logiq E9, in m/s) and a prototype system that measures SoS (in m/s). A reflector was positioned opposite the US probe as a timing reference for SoS, with the muscle in between. Reproducible tissue compression was applied by reducing probe-reflector distance in 5 mm steps. The Ogden hyperelastic model and the acoustoelastic theory were used to characterize SoS and SWS variations with tissue compression and extract novel metrics related to tissue nonlinearity. The body fat percentage (BF%) of the subjects was estimated using bioelectrical impedance analysis. RESULTS: A weak negative correlation was observed between SWS and SoS (r=-0.28, P=0.002). SWS showed an increasing trend with increasing tissue compression (P=0.10) while SoS values decayed nonlinearly (P<0.001). The acoustoelastic modeling showed a weak correlation for SWS (r=-0.36, P<0.001) but a very strong correlation for SoS (r=0.86, P<0.001), which was used to extract the SoS acoustoelastic parameter. SWS showed higher variability between both calves [intraclass correlation coefficient (ICC) =0.62, P=0.08] than SoS (ICC =0.91, P<0.001). Correlations with BF% were strong and positive for SWS (r=0.60, P<0.001), moderate and negative for SoS (r=-0.43, P=0.05), and moderate positive for SoS acoustoelastic parameter (r=0.48, P=0.03). CONCLUSIONS: SWS and SoS provide independent information about tissue elastic properties. SWS correlated stronger with BF% than SoS, but measurements were less reliable. SoS enabled the extraction of novel metrics related to tissue nonlinearity with potential complementary information.

17.
Medicine (Baltimore) ; 100(21): e25947, 2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34032704

RESUMO

ABSTRACT: To compare the speed of propagation of ultrasound (US) waves (SoS) of the lower leg with the clinical reference standard computed tomography (CT) at the level of lumbar vertebra 3 (L3) for muscle loss assessment. Both calf muscles of 50 patients scheduled for an abdominal CT were prospectively examined with ultrasound. A plexiglas-reflector located on the opposite side of the probe with the calf in between was used as a timing reference for SoS (m/s). CT measurements were performed at the level of L3 and included area (cm2) and attenuation (HU) of the psoas muscle, abdominal muscles, subcutaneous fat, visceral fat and abdominal area. Correlations between SoS, body mass index (BMI) and CT were determined using Pearson's correlation coefficient. Based on reported CT sarcopenia threshold values, receiver operating characteristic (ROC) analysis was performed for SoS. Inter-examiner agreement was assessed with the median difference, inter-quartile range (IQR) and intraclass correlation coefficients. SoS of the calf correlated moderately with abdominal muscle attenuation (r = 0.48; P < .001), psoas muscle attenuation (r = 0.40; P < .01), abdominal area (r = -0.44; P < .01) and weakly with subcutaneous fat area (r = -0.37; P < .01). BMI correlated weakly with psoas attenuation (r = -0.28; P < .05) and non-significantly with abdominal muscle attenuation. Normalization with abdominal area resulted in moderate correlations with abdominal muscle area for SoS (r = 0.43; P < .01) and BMI (r = -0.46; P < .001). Based on sarcopenia threshold values for skeletal muscle attenuation (SMRA), area under curve (AUC) for SoS was 0.724. Median difference between both examiners was -3.4 m/s with IQR = 15.1 m/s and intraclass correlation coefficient = 0.794. SoS measurements of the calf are moderately accurate based on CT sarcopenia threshold values, thus showing potential for muscle loss quantification.


Assuntos
Perna (Membro)/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Sarcopenia/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Feminino , Humanos , Gordura Intra-Abdominal/diagnóstico por imagem , Gordura Intra-Abdominal/fisiopatologia , Perna (Membro)/fisiopatologia , Vértebras Lombares , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Estudos Prospectivos , Curva ROC , Valores de Referência , Sarcopenia/fisiopatologia , Gordura Subcutânea/diagnóstico por imagem , Gordura Subcutânea/fisiopatologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Ultrassonografia
18.
Ultrasound Med Biol ; 47(12): 3529-3542, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34548187

RESUMO

There is a growing interest in quantifying shear-wave dispersion (SWD) with ultrasound shear-wave elastography (SWE). Recent studies suggest that SWD complements shear-wave speed (SWS) in diffuse liver disease diagnosis. To accurately interpret these metrics in clinical practice, we analyzed the impact of operator-dependent acquisition parameters on SWD and SWS measurements. Considered parameters were the acquisition depth, lateral position and size of the region of interest (ROI), as well as the size of the SWE acquisition box. Measurements were performed using the Canon Aplio i800 system (Canon Medical Systems, Otawara, Tochigi, Japan) and four homogeneous elasticity phantoms with certified stiffness values ranging from 3.7 to 44 kPa. In general, SWD exhibited two to three times greater variability than SWS. The acquisition depth was the main variance-contributing factor for both SWS and SWD, which decayed significantly with depth. The lateral ROI position contributed as much as the acquisition depth to the total variance in SWD. Locations close to the initial shear-wave excitation pulse were more robust to biases because of inaccurate probe-phantom coupling. The size of the ROI and acquisition box did not introduce significant variations. These results suggest that future guidelines on multiparametric elastography should account for the depth- and lateral-dependent variability of measurements.


Assuntos
Técnicas de Imagem por Elasticidade , Elasticidade , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia
19.
Medicine (Baltimore) ; 100(11): e23576, 2021 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-33725923

RESUMO

ABSTRACT: Short-term immobilization leads to fatty muscular degeneration, which is associated with various negative health effects. Based on literature showing very high correlations between MRI Dixon fat fraction and Speed-of-Sound (SoS), we hypothesized that we can detect short-term-immobilization-induced differences in SoS.Both calves of 10 patients with a calf cast on one side for a mean duration of 41 ±â€Š26 days were examined in relaxed position using a standard ultrasound machine. Calf perimeters were measured for both sides. A flat Plexiglas-reflector, placed vertically on the opposite side of the probe with the calf in-between, was used as a timing reference for SoS. SoS was both manually annotated by two readers and assessed by an automatic annotation algorithm. The thickness values of the subcutaneous fat and muscle layers were manually read from the B-mode images. Differences between the cast and non-cast calves were calculated with a paired t test. Correlation analysis of SoS and calf perimeter was performed using Pearson's correlation coefficient.Paired t test showed significant differences between the cast and non-cast side for both SoS (P < .01) and leg perimeter (P < .001). SoS was reduced with the number of days after cast installment (r = -0.553, P = .097). No significant differences were found for muscle layer thickness, subcutaneous fat layer thickness, mean fat echo intensity, or mean muscle echo intensity.Short-term-immobilization led to a significant reduction in SoS in the cast calf compared to the healthy calf, indicating a potential role of SoS as a biomarker in detecting immobilization-induced fatty muscular degeneration not visible on B-mode ultrasound.


Assuntos
Traumatismos da Perna/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Atrofia Muscular/diagnóstico por imagem , Restrição Física/efeitos adversos , Ultrassonografia/métodos , Adulto , Idoso , Moldes Cirúrgicos/efeitos adversos , Feminino , Humanos , Perna (Membro)/diagnóstico por imagem , Perna (Membro)/fisiopatologia , Traumatismos da Perna/fisiopatologia , Traumatismos da Perna/terapia , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Atrofia Muscular/etiologia , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Som , Adulto Jovem
20.
Clin Chem Lab Med ; 48(4): 555-60, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20148720

RESUMO

BACKGROUND: Hyperhomocysteinemia is a risk factor for ischemic heart disease. Several other mechanisms apply also to dilative types of heart failure of various, non-ischemic etiologies. We hypothesized that hyperhomocysteinemia is associated with left ventricular (LV) dilatation and hypertrophy in dilative cardiomyopathy. METHODS: Homocysteine was measured in 66 individuals with suspected cardiomyopathy. Cardiac magnetic resonance imaging was used to assess LV volume, mass, and wall stress. RESULTS: Hyperhomocysteinemia (> 12 micromol/L) was found in 45 patients (68%). LV mass was greater in these patients compared with individuals with normal homocysteine (83+/-27 vs. 67+/-19 g/m(2); p<0.02). Homocysteine was increased in patients with increased brain natriuretic peptide > or = 100 pg/mL (18.3+/-5.9 vs. 14.9+/-5.1 micromol/L; p=0.018). LV mass, LV end-diastolic and end-systolic volume (LVEDV, LVESV) were significantly increased in individuals in the upper quartile compared with the lower quartile (90+/-25 vs. 65+/-18 g/m(2), p=0.021; 114+/-50 vs. 71+/-23 mL/m(2), p=0.042; 76+/-51 vs. 36+/-22 mL/m(2), p=0.045). LV dilatation (LVEDV > or = 90 mL/m(2)) was more common in hyperhomocysteinemia (> 12 micromol/L, p=0.0166). Normalized LV mass was correlated with homocysteine (r=0.346, p=0.065). Homocysteine was not significantly correlated with LVEDV (r=0.229, p=0.065), LV end-diastolic wall stress (r=0.226, p=0.069) and LV ejection fraction. CONCLUSIONS: Hyperhomocysteinemia appears to be, at least in part, involved in a disproportional LV dilatation, where the ensuing hypertrophy is not sufficient to compensate for the increased wall stress. A potential mechanism is the hyperhomocysteinemia associated increase in oxidative stress that favors muscle fiber slippage.


Assuntos
Hiper-Homocisteinemia/complicações , Hipertrofia Ventricular Esquerda/etiologia , Remodelação Ventricular , Adulto , Dilatação Patológica/etiologia , Feminino , Ventrículos do Coração/fisiopatologia , Homocisteína/análise , Humanos , Hiper-Homocisteinemia/diagnóstico , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/análise , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA