1.
Med Phys ; 48(5): 2145-2159, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33666243

RESUMO

PURPOSE: The surgical navigation system that provides guidance throughout the surgery can facilitate safer and more radical liver resections, but such a system should also be able to handle organ motion. This work investigates the accuracy of intraoperative surgical guidance during open liver resection, with a semi-rigid organ approximation and electromagnetic tracking of the target area. METHODS: The suggested navigation technique incorporates a preoperative 3D liver model based on diagnostic 4D MRI scan, intraoperative contrast-enhanced CBCT imaging and electromagnetic (EM) tracking of the liver surface, as well as surgical instruments, by means of six degrees-of-freedom micro-EM sensors. RESULTS: The system was evaluated during surgeries with 35 patients and resulted in an accurate and intuitive real-time visualization of liver anatomy and tumor's location, confirmed by intraoperative checks on visible anatomical landmarks. Based on accuracy measurements verified by intraoperative CBCT, the system's average accuracy was 4.0 ± 3.0 mm, while the total surgical delay due to navigation stayed below 20 min. CONCLUSIONS: The electromagnetic navigation system for open liver surgery developed in this work allows for accurate localization of liver lesions and critical anatomical structures surrounding the resection area, even when the liver was manipulated. However, further clinically integrating the method requires shortening the guidance-related surgical delay, which can be achieved by shifting to faster intraoperative imaging like ultrasound. Our approach is adaptable to navigation on other mobile and deformable organs, and therefore may benefit various clinical applications.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Cirurgia Assistida por Computador , Fenômenos Eletromagnéticos , Humanos , Imageamento Tridimensional , Fígado/diagnóstico por imagem , Fígado/cirurgia
2.
PLoS One ; 12(12): e0189963, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29261769

RESUMO

BACKGROUND: For patients with suspicious lung lesions found on chest x-ray or CT, endo/trans- bronchial biopsy of the lung is the preferred method for obtaining a diagnosis. With the addition of new screening programs, a higher number of patients will require diagnostic biopsy which will prove even more challenging due to the small size of lesions found with screening. There are many endobronchial tools available on the market today and a wide range of new tools under investigation to improve diagnostic yield. However, there is little information available about the optimal tool size required to reach the majority of lesions, especially peripheral ones. In this manuscript we investigate the percentage of lesions that can be reached for various diameter tools if the tools remain inside the airways (i.e. endobronchial biopsy) and the distance a tool must travel "off-road" (or outside of the airways) to reach all lesions. METHODS AND FINDINGS: To further understand the distribution of lung lesions with respect to airway sizes and distances from the airways, six 3D models of the lung were generated. The airways were modeled at two different respiratory phases (inspiration and expiration). Three sets of 1,000 lesions were randomly distributed throughout the lung for each respiratory phase. The simulations showed that the percentage of reachable lesions decreases with increasing tool diameter and decreasing lesion diameter. A 1mm diameter tool will reach <25% of 1cm lesions if it remains inside the airways. To reach all 1cm lesions this 1mm tool would have to navigate through the parenchyma up to 8.5mm. CT scans of 21 patient lesions confirm these results reasonably well. CONCLUSIONS: The smaller the tool diameter the more likely it will be able to reach a lung lesion, whether it be for diagnostic biopsy, ablation, or resection. However, even a 1mm tool is not small enough to reach the majority of small (1-2cm) lesions. Therefore, it is necessary for endobronchial tools to be able to navigate through the parenchyma to reach the majority of lesions.


Assuntos
Biópsia/instrumentação , Brônquios/patologia , Modelos Biológicos , Brônquios/diagnóstico por imagem , Simulação por Computador , Desenho de Equipamento , Humanos , Tomografia Computadorizada por Raios X
3.
Lung Cancer ; 98: 62-68, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27393508

RESUMO

OBJECTIVES: Difficulties in obtaining a representative tissue sample are a major obstacle in timely selecting the optimal treatment for patients with lung cancer or other malignancies. Having a modality to provide needle guidance and confirm the biopsy site selection could be of great clinical benefit, especially when small masses are targeted. The objective of this study was to evaluate whether diffuse reflectance spectroscopy (DRS) at the tip of a core biopsy needle can be used for biopsy site confirmation in real time, thereby enabling optimized biopsy acquisition and improving diagnostic capability. MATERIALS AND METHODS: We included a total of 23 patients undergoing a routine computed tomography (CT) guided transthoracic needle biopsy of a lesion suspected for lung cancer or metastatic disease. DRS measurements were acquired during needle insertion and clinically relevant parameters were extracted from the spectral data along the needle paths. Histopathology results were compared with the DRS data at the final measurement position. RESULTS: Analysis of the collective data acquired from all enrolled subjects showed significant differences (p<0.01) for blood content, stO2, water content, and scattering amplitude. The identified spectral contrast matched the final pathology in 20 out of 22 clinical cases that could be used for analysis, which corresponds with an overall diagnostic performance of 91%. Three cases underlined the importance of adequate reference measurements and the need for real time diagnostic feedback. Continuous real time DRS measurements performed during a biopsy procedure in one patient provided clear information with respect to the variation in tissue and allowed identification of the tumour boundary. CONCLUSIONS: The presented technology creates a basis for the design and clinical implementation of integrated fibre-optic tools for a variety of minimal invasive applications.


Assuntos
Biópsia Guiada por Imagem , Neoplasias Pulmonares/diagnóstico , Imagem de Difusão por Ressonância Magnética , Humanos , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/normas , Imagem Óptica , Tomografia Computadorizada por Raios X , Carga Tumoral
4.
Clin Cancer Res ; 22(2): 357-65, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26324737

RESUMO

PURPOSE: This study presents the first in vivo real-time tissue characterization during image-guided percutaneous lung biopsies using diffuse reflectance spectroscopy (DRS) sensing at the tip of a biopsy needle with integrated optical fibers. EXPERIMENTAL DESIGN: Tissues from 21 consented patients undergoing lung cancer surgery were measured intraoperatively using the fiber-optic platform capable of assessing various physical tissue properties highly correlated to tissue architecture and composition. In addition, the method was tested for clinical use by performing DRS tissue sensing during 11 routine biopsy procedures in patients with suspected lung cancer. RESULTS: We found that water content and scattering amplitude are the primary discriminators for the transition from healthy lung tissue to tumor tissue and that the reliability of these parameters is not affected by the amount of blood at the needle tip. In the 21 patients measured intraoperatively, the water-to-scattering ratio yielded a 56% to 81% contrast difference between tumor and surrounding tissue. Analysis of the 11 image-guided lung biopsy procedures showed that the tissue diagnosis derived from DRS was diagnostically discriminant in each clinical case. CONCLUSIONS: DRS tissue sensing integrated into a biopsy needle may be a powerful new tool for biopsy guidance that can be readily used in routine diagnostic lung biopsy procedures. This approach may not only help to increase the successful biopsy yield for histopathologic analysis, but may also allow specific sampling of vital tumor tissue for genetic profiling.


Assuntos
Neoplasias Pulmonares/patologia , Pulmão/patologia , Adulto , Idoso , Biópsia por Agulha/métodos , Estudos de Viabilidade , Tecnologia de Fibra Óptica/métodos , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Análise Espectral/métodos