Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38554125

RESUMO

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Assuntos
Estenose da Valva Aórtica , Benchmarking , Tempo de Internação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Masculino , Feminino , Idoso de 80 Anos ou mais , Tempo de Internação/estatística & dados numéricos , Idoso , Procedimentos Clínicos , Europa (Continente)/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Segurança do Paciente
2.
Eur J Clin Invest ; 54(9): e14241, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38767226

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Próteses Valvulares Cardíacas , Falha de Prótese , Masculino , Idoso
3.
Vascular ; : 17085381241237844, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504140

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become the standard treatment for severe aortic valve stenosis in patients at increased surgical risk. Percutaneous transfemoral (TF) is the access of choice due to its reduced invasiveness and perioperative morbidity/mortality compared with the trans-axillary, aortic, and apical routes. On the other hand, vascular access complications (VACs) of the TF access are associated with prolonged hospitalization, 30-day, and 1-year mortality. In addition, the concomitance of peripheral arterial disease may require associated endovascular management. A multidisciplinary team with Interventional Cardiologists and Vascular Surgeons may minimize the rate of VACs in patients with challenging femoral-iliac access or concomitant disease of other vascular districts, thus optimizing the outcome of TF-TAVI. The aim of this study was to evaluate the role of Vascular Surgeons in TF TAVI procedures. METHODS: We conducted a retrospective single-center review of all TF-TAVI procedures assisted by Vascular Surgeons between January 2016 and December 2020 in a high-volume tertiary hospital. Pre, intra, and postoperative data were analyzed by a dedicated group of Interventional Cardiologists and Vascular Surgeons. VACs were defined according with the Valve Academic Research Consortium (VARC) three guidelines. The outcomes of TF-TAVI procedures with Vascular Surgeons involvement were assessed as study's endpoints. RESULTS: Overall, 937 TAVI procedures were performed with a TF approach ranging between 78% (2016) and 98% (2020). Vascular Surgeons were involved in 67 (7%) procedures with the following indications: concomitant abdominal aortic aneurysm (EVAR + TAVI) - 3 (4%), carotid stenosis (TAVI + CAS) - 2 (3%), hostile femoral/iliac access, or VACs - 62 (93%). Balloon angioplasty of iliac artery pre-TAVI implantation was performed in 51 cases (conventional PTA: 38/51%-75%; conventional PTA + intravascular lithotripsy: 13/51%-25%; stenting: 5/51%-10%). TAVI procedure was successfully completed by percutaneous TF approach in all 62 cases with challenging femoral/iliac access. VACs necessitating interventions were 18/937 (2%) cases, localized to the common femoral or common/external iliac artery in 15/18 (83%) and 3/18 (17%) cases, respectively. They were managed by surgical or endovascular maneuvers in 3/18 (17%) and 15/18 (83%) cases, respectively. Fifteen/18 (83%) VACs were treated during the index procedure. There was no procedure-related mortality or 30-day readmission. CONCLUSION: In our experience, Vascular Surgeon assistance in TAVI procedures was not infrequent and allowed safe and effective device introduction through challenging TF access. Similarly, the concomitant significant disease of other vascular districts could be safely addressed, potentially reducing postoperative related mortality and morbidity. The implementation of multidisciplinary team with interventional cardiologists and vascular surgeons should be encouraged whenever possible.

4.
Am J Cardiol ; 222: 20-22, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38663573

RESUMO

Transcatheter aortic valve implantation (TAVI) in native pure aortic regurgitation (AR) with off-label use of balloon-expandable valves (BEV) has been reported. However, there are scant data regarding optimal oversizing and its safety, and our study assessed BEV oversizing and outcomes of TAVI. Thirteen consecutive tricuspid aortic valve patients who underwent transfemoral TAVIs for pure AR with Sapien BEV at our center between 2019 and 2023 (69.2% males, mean age 80.8 years, Society of Thoracic Surgeons 4.0%) were divided into small annulus (SA) group (≤618 mm2) where ≥20% oversizing is achievable based on published data on BEV overexpansion, and larger annulus (LA) group (>618 mm2). Overexpansion and actual oversizing were measured on postprocedural computed tomography scan. Technical success was 92.3% with 1 valve embolization in the LA group. The postprocedural computed tomography showed a mean 28.3% oversizing, significantly higher in SA (31.2%) than in LA group (19.4%), p = 0.0092. Oversizing ≥20% was achieved in 100% SA versus 33.3% LA patients (p = 0.046). In conclusion, TAVI in pure AR with oversized Sapien BEV showed good procedural and short-term outcomes when ≥20% oversizing was predictably achievable.


Assuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Insuficiência da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Idoso , Estudos Retrospectivos , Uso Off-Label , Resultado do Tratamento , Tomografia Computadorizada por Raios X
5.
Minerva Cardiol Angiol ; 72(4): 313-328, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38535984

RESUMO

Renal denervation (RDN) is a safe and effective strategy for the treatment of difficult to treat hypertension. The blood pressure (BP)-lowering efficacy of RDN is comparable to those of many single antihypertensive medications and it allows to consider the RDN as a valuable option for the treatment of difficult to treat hypertension together with lifestyle modifications and medical therapy. A multidisciplinary team is of pivotal importance from the selection of the patient candidate for the procedure to the post-procedural management. Further studies are needed to investigate the effect of RDN on clinical outcomes and to better identify the predictors of BP response to RDN in order to recognize the patients who are more likely to benefit from the procedure.


Assuntos
Anti-Hipertensivos , Hipertensão , Rim , Simpatectomia , Humanos , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Cardiologia , Denervação/métodos , Hipertensão/terapia , Hipertensão/cirurgia , Itália , Rim/inervação , Simpatectomia/métodos
6.
Artigo em Inglês | MEDLINE | ID: mdl-39164142

RESUMO

BACKGROUND: There is little data on the outcome of balloon aortic valvuloplasty (BAV) in relation to valve dimensions and calcification patterns. The procedure is not standardized, particularly the choice of balloon size. METHODS: This retrospective multicenter study focused on BAV efficacy and safety by analyzing the relationship between balloon size, annulus geometry (i.e., diameters, perimeter, and area), and calcification patterns (total burden and calcium distribution over each individual leaflet). From March 2018 to March 2023, all consecutive patients who underwent clinically indicated BAV and ECG-gated multidetector computed tomography of the aorta were included, except those with a bicuspid valve. Calcium score was calculated on contrast-enhanced images based on a luminal attenuation threshold of +100 HU. RESULTS: One hundred and fifteen patients were included. Procedural success was 82.6 %. The balloon-to-annulus ratio (BAR) relative to diameter, perimeter, and area was higher in patients with successful BAV. Patients with unsuccessful BAV had a significantly higher aortic valve calcium burden. The complication rate was 4.3 % and there was no association with valve geometry or calcium burden. A trend towards a reduced complication rate was found as calcium asymmetry increased. BAR minimum annulus diameter was the best parameter in predicting procedural success, with a cut-off at 0.85. CONCLUSIONS: BAV efficacy is correlated directly with balloon size in relation to annulus dimension and inversely with total calcium burden. The minimum diameter of the valve may be adopted as a reference for balloon sizing.

7.
EuroIntervention ; 20(8): e504-e510, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629420

RESUMO

The treatment of coronary artery disease (CAD) in patients with severe aortic valve stenosis (AVS) eligible for transcatheter aortic valve implantation (TAVI) is not supported by clinical evidence, and the role of physiology over anatomy as well as the timing of coronary intervention are not defined. FAITAVI (ClinicalTrials.gov: NCT03360591) is a nationwide prospective, open-label, multicentre, randomised controlled study comparing the angiography-guided versus the physiology-guided coronary revascularisation strategy in patients with combined significant CAD and severe AVS undergoing TAVI. Significant CAD will be defined as coronary stenosis ≥50%, as assessed by visual estimation in vessels ≥2.5 mm. Physiology will be tested by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). The study will be conducted at 15 sites in Italy. In the angiography arm, percutaneous coronary intervention (PCI) will be performed either before TAVI, during the TAVI procedure - before or after the valve implantation - or within 1 month±5 days of the valve implantation, left to the operator's decision. In the physiology arm, FFR and iFR will be performed before TAVI, and PCI will be indicated for FFR ≤0.80, otherwise the intervention will be deferred. In case of borderline values (0.81-0.85), FFR and iFR will be repeated after TAVI, with PCI performed when needed. With a sample size of 320 patients, the study is powered to evaluate the primary endpoint (a composite of death, myocardial infarction, stroke, major bleeding, or ischaemia-driven target vessel revascularisation). TAVI indication, strategy and medical treatment will be the same in both groups. After discharge, patients will be contacted at 1, 6, 12 and 24 months after the procedure to assess their general clinical status, and at 12 months for the occurrence of events included in the primary and secondary endpoints. FAITAVI is the first randomised clinical trial to investigate "optimal" percutaneous coronary intervention associated with TAVI in patients with severe AVS and CAD.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
8.
Int J Cardiol ; 400: 131694, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38160911

RESUMO

Pulmonary embolism (PE) is a potentially life-threatening condition that remains a major global health concern. Noteworthy, patients with high- and intermediate-high-risk PE pose unique challenges because they often display clinical and hemodynamic instability, thus requiring rapid intervention to mitigate the risk of clinical deterioration and death. Importantly, recovery from PE is associated with long-term complications such as recurrences, bleeding with oral anticoagulant treatment, pulmonary hypertension, and psychological distress. Several novel strategies to improve risk factor characterization and management of patients with PE have recently been introduced. Accordingly, this position paper of the Working Group of Interventional Cardiology of the Italian Society of Cardiology deals with the landscape of high- and intermediate-high risk PE, with a focus on bridging the gap between the evolving standards of care and the current clinical practice. Specifically, the growing importance of catheter-directed therapies as part of the therapeutic armamentarium is highlighted. These interventions have been shown to be effective strategies in unstable patients since they offer, as compared with thrombolysis, faster and more effective restoration of hemodynamic stability with a consistent reduction in the risk of bleeding. Evolving standards of care underscore the need for continuous re-assessment of patient risk stratification. To this end, a multidisciplinary approach is paramount in refining selection criteria to deliver the most effective treatment to patients with unstable hemodynamics. In conclusion, the current management of unstable patients with PE should prioritize tailored treatment in a patient-oriented approach in which transcatheter therapies play a central role.


Assuntos
Cardiologia , Embolia Pulmonar , Humanos , Terapia Trombolítica/efeitos adversos , Embolia Pulmonar/terapia , Embolia Pulmonar/tratamento farmacológico , Trombectomia , Hemorragia/induzido quimicamente , Resultado do Tratamento , Itália/epidemiologia , Fibrinolíticos/uso terapêutico
9.
Int J Cardiol ; 401: 131861, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38365014

RESUMO

INTRODUCTION: The potential benefit on long term outcomes of Percutaneous Coronary Intervention (PCI) on Unprotected Left Main (ULM) driven by IntraVascular UltraSound (IVUS) remains to be defined. METHODS: IMPACTUS LM-PCI is an observational, multicenter study that enrolled consecutive patients with ULM disease undergoing coronary angioplasty in 13 European high-volume centers from January 2002 to December 2015. Major Adverse Cardiovascular Events (MACEs) a composite of cardiovascular (CV) death, target vessel revascularization (TVR) and myocardial infarction (MI) were the primary endpoints, while its single components along with all cause death the secondary ones. RESULTS: 627 patients with ULM disease were enrolled, 213 patients (34%) underwent IVUS-guided PCI while 414 (66%) angioguided PCI. Patients in the two cohorts had similar prevalence of risk factors except for active smoking and clinical presentation. During a median follow-up of 7.5 years, 47 (22%) patients in the IVUS group and 211 (51%) in the angio-guided group underwent the primary endpoint (HR 0.42; 95% CI [0.31-0.58] p < 0.001). After multivariate adjustment, IVUS was significantly associated with a reduced incidence of the primary endpoint (adj HR 0.39; 95% CI [0.23-0.64], p < 0.001), mainly driven by a reduction of TVR (ad HR 0.30, 95% CI [0.15-0.62], p = 0.001) and of all-cause death (adj HR 0.47, 95% CI [0.28-0.82], p = 0.008). IVUS use, age, diabetes, side branch stenosis, DES and creatinine at admission were independent predictors of MACE. CONCLUSIONS: In patients undergoing ULM PCI, the use of IVUS was associated with a reduced risk at long-term follow-up of MACE, all-cause death and subsequent revascularization.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Ultrassonografia de Intervenção
10.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986659

RESUMO

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Feminino , Masculino , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Readmissão do Paciente , Recuperação de Função Fisiológica , Europa (Continente) , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Hemodinâmica
11.
Int J Cardiol Heart Vasc ; 53: 101460, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39070183

RESUMO

Objective: Bleeding is frequent during transcatheter aortic valve implantation (TAVI), especially when performed through a transapical approach (TA), and is associated with a worse prognosis. The present study aims to test the implication of red blood cell (RBC) transfusion and the optimal transfusion strategy in this context. Methods: Among 11,265 participants in the multicenter TRITAVI (Transfusion Requirements in Transcatheter Aortic Valve Implantation) registry, 548 patients (4.9%) who received TA-TAVI at 19 European centers were included. One-to-one propensity score matching was performed to reduce treatment selection bias and potential confounding among transfused versus non-transfused patients. The primary endpoint of the study was the 30-day occurrence of all-cause mortality. Results: 209 patients (38 %) received RBC transfusions. The primary endpoint occurred in 47 (8.6 %) patients. Propensity score matching identified 188 pairs of patients with and without RBC transfusion. In the propensity score-matched analysis, RBC transfusion was associated with increased 30-day mortality (HR 3.35, 95 % CI 1.51 - 7.39; p = 0.002). At multivariable cox regression analysis, RBC transfusion was an independent predictor of 30-day mortality (HR 3.07, 95 % CI 1.01-9.41, p = 0.048), as well as baseline ejection fraction (HR 0.96, 95 % CI 0.92-0.99, p = 0.043), and acute kidney injury (HR 3.95, 95 % CI 1.11-14.05, p = 0.034). Conclusions: RBC transfusion is an independent predictor of short-term mortality in patients undergoing TA-TAVI, regardless of major bleeding.Clinical trial registration: https://www.clinicaltrials.gov Unique identifier: NCT03740425.

12.
J Am Heart Assoc ; 13(7): e032955, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533944

RESUMO

BACKGROUND: Dialysis is a rare but serious complication after transcatheter aortic valve replacement. We analyzed the large multicenter TRITAVI (transfusion requirements in transcatheter aortic valve implantation) registry in order to develop and validate a clinical score assessing this risk. METHODS AND RESULTS: A total of 10 071 consecutive patients were enrolled in 19 European centers. Patients were randomly assigned (2:1) to a derivation and validation cohort. Two scores were developed, 1 including only preprocedural variables (TRITAVIpre) and 1 also including procedural variables (TRITAVIpost). In the 6714 patients of the derivation cohort (age 82±6 years, 48% men), preprocedural factors independently associated with dialysis and included in the TRITAVIpre score were male sex, diabetes, prior coronary artery bypass graft, anemia, nonfemoral access, and creatinine clearance <30 mL/min per m2. Additional independent predictors among procedural features were volume of contrast, need for transfusion, and major vascular complications. Both scores showed a good discrimination power for identifying risk for dialysis with C-statistic 0.78 for TRITAVIpre and C-statistic 0.88 for TRITAVIpost score. Need for dialysis increased from the lowest to the highest of 3 risk score groups (from 0.3% to 3.9% for TRITAVIpre score and from 0.1% to 6.2% for TRITAVIpost score). Analysis of the 3357 patients of the validation cohort (age 82±7 years, 48% men) confirmed the good discrimination power of both scores (C-statistic 0.80 for TRITAVIpre and 0.81 for TRITAVIpost score). Need for dialysis was associated with a significant increase in 1-year mortality (from 6.9% to 54.4%; P=0.0001). CONCLUSIONS: A simple preprocedural clinical score can help predict the risk of dialysis after transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Sistema de Registros , Diálise Renal , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Multicêntricos como Assunto
13.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479968

RESUMO

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia
14.
Am J Cardiol ; 219: 60-70, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38401656

RESUMO

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Fatores Sexuais , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia
15.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930026

RESUMO

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

16.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-38749449

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Fatores de Risco , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Resultado do Tratamento , Idoso de 80 Anos ou mais , Incidência , Fatores de Tempo , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/fisiopatologia , Europa (Continente) , Medição de Risco , Desenho de Prótese , Razão de Chances , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/diagnóstico , Estudos Retrospectivos
17.
J Soc Cardiovasc Angiogr Interv ; 1(4): 100347, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-39131939

RESUMO

Background: Coronary obstruction following transcatheter aortic valve replacement (TAVR) is a life-threatening complication. For patients at elevated risk, it is not known how valve choice is influenced by clinical and anatomic factors and how outcomes differ between valve platforms. For patients at high risk of coronary obstruction, we sought to describe the anatomical and clinical characteristics of patients treated with both balloon-expandable (BE) and self-expanding (SE) valves. Methods: This was a multicenter international registry of patients undergoing TAVR who are considered to be at high risk of coronary obstruction and receiving pre-emptive coronary protection. Results: A total of 236 patients were included. Patients receiving SE valves were more likely to undergo valve-in-valve procedures and also had smaller sinuses of Valsalva and valve-to-coronary distance. Three-year cardiac mortality was 21.6% with SE vs 3.7% with BE valves. This was primarily driven by increased rates of definite or probable coronary occlusion, which occurred in 12.1% of patients with SE valves vs 2.1% in patients with BE valves. Conclusions: In patients undergoing TAVR with coronary protection, those treated with SE valves had increased rates of clinical and anatomic features that increase the risk of coronary obstruction. These include an increased frequency of valve-in-valve procedures, smaller sinuses of Valsalva, and smaller valve-to-coronary distances. These patients were observed to have increased cardiac mortality compared with patients treated with BE valves, but this is likely due to their higher risk clinical and anatomic phenotypes rather than as a function of the valve type itself.

19.
Rev. bras. cardiol. invasiva ; 19(1): 24-27, mar. 2011.
Artigo em Português | LILACS | ID: lil-591714

RESUMO

Introdução: O implante transcateter de prótese valvular aórtica (ITVA) tem sido utilizado em nosso meio e em diversos países do mundo como alternativa ao tratamento conservador em pacientes com estenose aórtica grave e elevado risco cirúrgico. Objetivou-se descrever o perfil clínico basal e a mortalidade a curto e médio prazos de uma série consecutiva de casos tratados com ITVA em dois centros localizados, respectivamente, na Itália e no Brasil. Métodos: A população de estudo foi composta pelos primeiros 75 pacientes consecutivos com estenose valvar aórtica grave tratados com a prótese Medtronic CoreValve TM Revalving System (MCV – Medtronic, Minneapolis, Estados Unidos). Tipicamente, a indicação para o ITVA foi motivada pelo alto risco cirúrgico. A média de idade era de 82 anos, 55% eram mulheres, um terço apresentava doença pulmonar grave e 95% apresentavam insuficiência cardíaca sintomática. Resultados: Após o ITVA, houve redução significativa do gradiente transvalvar aórtico máximo (basal: 95,8 + 32,3 mmHg; pós-procedimento: 18,5 + 6,1 mmHg) e médio (basal: 45,9 + 16,9 mmHg; pós-procedimento: 10,4 + 5,2 mmHg) (P < 0,01 para ambos). Insuficiência aórtica moderada ou acentuada foi evidenciada em 7% dos casos após ITVA. A taxa de sobrevida global aos 30 dias foi de 91,6% e aos 12 meses, de 79%. Conclusões: O ITVA surge como um método terapêutico de grande relevância para portadores de estenose aórtica de alto risco cirúrgico. As taxas de sobrevida precoce e a médio prazo indicam o benefício potencial do novo procedimento também para pacientes tratados no chamado mundo real.


Background: Transcatheter aortic valve implantation (TAVI) has been used in our country and in several differentcountries worldwide as an alternative to conservative treatment for patients with severe aortic stenosis and high surgicalrisk. This paper aimed at describing the baseline clinical profile and the short and medium-term mortality of a consecutive series of cases treated with TAVI in two centers in Italy and Brazil, respectively. Methods: The study population included the first 75 consecutive patients with severeaortic stenosis treated with the Medtronic CoreValveTM Revalving System (MCV – Medtronic, Minneapolis, USA). Typically, the indication for TAVI was motivated by high surgical risk. Mean age was 82 years, 55% were females, a third had severe lung disease, and 95% had symptomaticheart failure. Results: TAVI was associated with a significant reduction of peak (baseline: 95.8 + 32.3 mmHg; postprocedure: 18.5 + 6.1 mmHg) and mean (baseline: 45.9 + 16.9 mmHg; post-procedure: 10.4 + 5.2 mmHg) transaortic gradient (P < 0.01 for both). Moderate or severe aortic insufficiencywas observed in 7% of the cases. The overall survival rate at 30 days was 91.6% and at 12 months it was 79%.Conclusions: TAVI emerges as an important therapeutic option for high risk patients with aortic stenosis. The short and mediumterm survival rates suggest that the new procedure might beof benefit for patients treated in the real world context.


Assuntos
Humanos , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Aspirina/administração & dosagem , Cateterismo , Heparina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA