Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 91(1): 013318, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012583

RESUMO

Electron Cyclotron Resonance Ion Source (ECRIS) plasmas contain high-energy electrons and highly charged ions implying that only noninvasive methods such as optical emission spectroscopy are reliable in their characterization. A high-resolution spectrometer (10 pm FWHM at 632 nm) enabling the detection of weak emission lines has been developed at University of Jyväskylä, Department of Physics (JYFL) for this purpose. Diagnostics results probing the densities of ions, neutral atoms, and the temperature of the cold electron population in the JYFL 14 GHz ECRIS are described. For example, it has been observed that the cold electron temperature drops from 40 eV to 20 eV when the extraction voltage of the ion source is switched off, accompanied by two orders of magnitude decrease in Ar9+ optical emission intensity, suggesting that diagnostics results of ECRIS plasmas obtained without the extraction voltage are not depicting the plasma conditions of normal ECRIS operation. The relative changes of the plasma optical emission and the ion beam current have been measured in CW and amplitude modulation operation mode of microwave injection. It is concluded that in the CW mode, the ion currents could be limited by diffusion transport and electrostatic confinement of the ions rather than beam formation in the extraction region and subsequent transport. The high resolution of the spectrometer allows determining the ion temperature by measuring the Doppler broadening of the emission lines and subtracting the wavelength dependent instrumental broadening. The measured ion temperatures in the JYFL 14 GHz ECRIS are between 5 and 28 eV, depending on the plasma species and charge state. Gas mixing is shown to be an effective method to decrease the ion temperature of high charge state argon ions from 20 eV in pure argon discharge to 5 eV when mixed with oxygen.

2.
Rev Sci Instrum ; 90(11): 113321, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31779446

RESUMO

The order-of-magnitude performance leaps of ECR ion sources over the past decades result from improvements to the magnetic plasma confinement, increases in the microwave heating frequency, and techniques to stabilize the plasma at high densities. Parallel to the technical development of the ion sources themselves, significant effort has been directed into the development of their plasma diagnostic tools. We review the recent results of Electron Cyclotron Resonance Ion Source (ECRIS) plasma diagnostics highlighting a number of selected examples of plasma density, electron energy distribution, and ion confinement time measurements, obtained mostly with the second-generation sources operating at frequencies from 10 to 18 GHz. The development of minimum-B ECR ion sources based on the superposition of solenoid and sextupole fields has long relied on semiempirical scaling laws for the strength of the magnetic field with increasing plasma heating frequency. This approach is becoming increasingly difficult with the looming limits of superconducting technologies being able to satisfy the magnetic field requirements at frequencies approaching 60 GHz. Thus, we discuss alternative ECRIS concepts and proposed modifications to existing sources that are supported by the current understanding derived from the plasma diagnostics experiments.

3.
Rev Sci Instrum ; 83(2): 02A323, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380170

RESUMO

iThemba Laboratory for Accelerator Based Science (iThemba LABS) is a multi-disciplinary accelerator facility. One of its main activities is the operation of a separated-sector cyclotron with a K-value of 200, which provides beams of various ion species. These beams are used for fundamental nuclear physics research in the intermediate energy region, radioisotope production, and medical physics applications. Due to the requirements of nuclear physics for new ion species and higher energies, the decision was made to install a copy of the so-called Grenoble test source (GTS) at iThemba LABS. In this paper, we will report on the experimental setup and the first results obtained with the GTS2 at iThemba LABS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA