Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 24(1): 859, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37919702

RESUMO

BACKGROUND: Virtual Reality (VR) systems have been increasingly used across several medical fields. A crucial preliminary step for developing optimized VR-based applications for rehabilitation purposes is identifying potential interventions to meet the requirements necessary to satisfy end-users' needs. This study aims to assess the acceptability, usability, and appropriateness of a VR physical therapy program executed with Oculus Quest 2 by expert physiotherapists of shoulder musculoskeletal rehabilitation. METHODS: Eleven physiotherapists were enrolled to test a VR program for shoulder musculoskeletal rehabilitation. At the end of each session, physiotherapists completed three questionnaires about the acceptability, usability, and appropriateness of the VR system and application, investigating aspects such as wearability, safety, stability, ease of control, comfort, size, utility, playability, and use mode. RESULTS: The acceptability questionnaire revealed that all the physiotherapists found the VR system easy to wear and control, very confident, and safe. The usability questionnaire showed that most physiotherapists (73%) found the VR application entertaining, although only 45% said the system could be used independently by patients without the support of a therapist. Many physiotherapists found the use of the VR application appropriate for patients with rotator cuff tears treated conservatively (63.6%) or surgically (54.5%), for patients with shoulder osteoarthritis treated conservatively (72.7%), for patients with shoulder osteoarthritis after surgical treatment (63.6%). 91% of physiotherapists think it would be best for patients to use the VR system under the supervision of a therapist and not independently in a home setting. CONCLUSIONS: The use of VR in orthopaedic rehabilitation is encouraging, although further efforts are needed to increase the independent use of patients without the supervision of a physiotherapist. Moreover, future studies should strive to ensure the clinical effectiveness of VR rehabilitation in reaching therapeutic goal settings.


Assuntos
Osteoartrite , Realidade Virtual , Humanos , Ombro , Extremidade Superior , Modalidades de Fisioterapia
2.
Sensors (Basel) ; 22(15)2022 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-35898015

RESUMO

Virtual reality (VR) systems are becoming increasingly attractive as joint kinematics monitoring systems during rehabilitation. This study aimed to evaluate the accuracy of the Oculus Quest 2 in measuring translational and rotational displacements. As the Oculus Quest 2 was chosen for future applications in shoulder rehabilitation, the translation range (minimum: ~200 mm, maximum: ~700 mm) corresponded to the forearm length of the 5th percentile female and the upper limb length of the 95th percentile male. The controller was moved on two structures designed to allow different translational displacements and rotations in the range 0-180°, to cover the range of motion of the upper limb. The controller measures were compared with those of a Qualisys optical capture system. The results showed a mean absolute error of 13.52 ± 6.57 mm at a distance of 500 mm from the head-mounted display along the x-direction. The maximum mean absolute error for rotational displacements was found to be 1.11 ± 0.37° for a rotation of 40° around the z-axis. Oculus Quest 2 is a promising VR tool for monitoring shoulder kinematics during rehabilitation. The inside-out movement tracking makes Oculus Quest 2 a viable alternative to traditional motion analysis systems.


Assuntos
Ombro , Realidade Virtual , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Movimento , Extremidade Superior
3.
Bioengineering (Basel) ; 10(11)2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38002429

RESUMO

Few studies have evaluated the effectiveness of shoulder rehabilitation in virtual environments. The objective of this study was to investigate the performance of a custom virtual reality application (VR app) with a stereophotogrammetric system considered the gold standard. A custom VR app was designed considering the recommended rehabilitation exercises following arthroscopic rotator cuff repair. Following the setting of the play space, the user's arm length, and height, five healthy volunteers performed four levels of rehabilitative exercises. Results for the first and second rounds of flexion and abduction displayed low total mean absolute error values and low numbers of unmet conditions. In internal and external rotation, the number of times conditions were not met was slightly higher; this was attributed to a lack of isolated shoulder movement. Data is promising, and volunteers were able to reach goal conditions more often than not. Despite positive results, more literature comparing VR applications with gold-standard clinical parameters is necessary. Nevertheless, results contribute to a body of literature that continues to encourage the application of VR to shoulder rehabilitation programs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA