Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
1.
J Med Syst ; 47(1): 58, 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37133553

RESUMO

BACKGROUND: Despite recent design improvements, human factors issues continue to challenge left ventricular assist device (LVAD) therapy. The aim of this study was to evaluate user experience of former non-HeartMate 3 (HM3) LVAD patients post heart transplantation (HTX) and laypersons (LP) with HM3 LVAD peripherals in simulated everyday and emergency scenarios. METHODS: This single center cohort study included untrained HTX and LP. Seven scenarios, including battery exchanges (without alarm, advisory alarm, dim light, consolidated bag), change of power supply, driveline dis-/reconnection and controller exchange were simulated. Subjects' gaze behavior was recorded using eye tracking technology. Success rate, pump-off-time, duration to success (DTS), percental fixation duration per areas of interest and post-scenario-survey results were defined as outcome measures. RESULTS: Thirty subjects completed 210 scenarios, initially solving 82.4% (HTX vs. LP, p = 1.00). Changing power supply revealed highest complexity (DTS = 251 ± 93s, p = 0.76): 26.7% succeeded at first attempt (p = 0.68), 56.7% at second attempt, with significantly more LP failing (p = 0.04), resulting in 10 hazards from driveline disconnections (pump-off-time 2-118s, p = 0.25). Comparison on initial success showed differences in fixation durations for seven areas of interest (p < 0.037). Decreasing DTS during battery exchanges (p < 0.001) indicate high learnability. Exchanging batteries within the bag took longer (median DTS = 75.0 (IQR = 45.0)s, p = 0.09), especially in elderly subjects (r = 0.61, p < 0.001). Subjects with less initial success were more afraid of making mistakes (p = 0.048). CONCLUSION: This eye tracking based human factors study provided insights into user experiences in handling HM3 peripherals. It highlights unintuitive and hazardous characteristics, providing guidance for future user-centered design of LVAD wearables.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Idoso , Insuficiência Cardíaca/cirurgia , Tecnologia de Rastreamento Ocular , Estudos de Coortes , Estudos Retrospectivos
2.
Artif Organs ; 46(6): 1149-1157, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34978722

RESUMO

BACKGROUND: A relation between the left ventricular assist device inflow cannula (IC) malposition and pump thrombus has been reported. This study aimed to investigate if the pump position, derived from chest X-rays in HeartMate 3 (HM3) patients, correlates with neurological dysfunction (ND), ischemic stroke (IS), hemorrhagic stroke (HS) and survival. METHODS: This analysis was performed on routinely acquired X-rays of 42 patients implanted with a HM3 between 2014 and 2017. Device position was quantified in patients with and without ND from frontal and lateral X-rays characterizing the IC and pump in relation to spine, diaphragm or horizontal line. The primary end-point was freedom from stroke and survival one-year after HM3 implantation stratified by pump position. RESULTS: The analysis of X-rays, 33.5 (41.0) days postoperative, revealed a significant smaller IC angle of HM3 patients with ND versus no ND (0.1° ± 14.0° vs. 12.9° ± 10.1°, p = 0.005). Additionally, the IC angle in the frontal view, IS: 4.1 (20.9)° versus no IS: 13.8 (7.5)°, p = 0.004 was significantly smaller for HM3 patients with IS. Using receiver operating characteristics derived cut-off, IC angle <10° provided 75% sensitivity and 100% specificity (C-statistic = 0.85) for predicting IS. Stratified by IC angle, freedom from IS at 12 months was 100% (>10°) and 60% (<10°) respectively (p = 0.002). No significant differences were found in any end-point between patients with and without HS. One-year survival was significantly higher in patients with IC angle >10° versus <10° (100% vs. 71.8%, p = 0.012). CONCLUSIONS: IC malposition derived from standard chest X-rays serves as a risk factor for ND, IS and worse survival in HM3 patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Cânula/efeitos adversos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/complicações , Trombose/etiologia
3.
Artif Organs ; 45(5): 464-472, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33052592

RESUMO

Driveline infections (DLI) are common adverse events in left ventricular assist devices (LVADs), leading to severe complications and readmissions. The study aims to characterize risk factors for DLI readmission 2 years postimplant. This single-center study included 183 LVAD patients (43 HeartMate II [HMII], 29 HeartMate 3 [HM3], 111 HVAD) following hospital discharge between 2013 and 2017. Demographics, clinical parameters, and outcomes were retrospectively analyzed and 12.6% of patients were readmitted for DLI, 14.8% experienced DLI but were treated in the outpatient setting, and 72.7% had no DLI. Mean C-reactive protein (CRP), leukocytes and fibrinogen were higher in patients with DLI readmission (P < .02) than in outpatient DLI and patients without DLI, as early as 60 days before readmission. Freedom from DLI readmission was comparable for HMII and HVAD (98% vs. 87%; HR, 4.52; 95% CI, 0.58-35.02; P = .15) but significantly lower for HM3 (72%; HR, 10.82; 95% CI, 1.26-92.68; P = .03). DLI (HR, 1.001; 95% CI, 0.999-1.002; P = .16) or device type had no effect on mortality. DLI readmission remains a serious problem following LVAD implantation, where CRP, leukocytes, and fibrinogen might serve as risk factors already 60 days before. HM3 patients had a higher risk for DLI readmissions compared to HVAD or HMII, possibly because of device-specific driveline differences.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Adulto , Idoso , Biomarcadores/sangue , Proteína C-Reativa/análise , Feminino , Fibrinogênio/análise , Seguimentos , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Infecções Relacionadas à Prótese/sangue , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia , Estudos Retrospectivos , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Fatores de Risco
4.
Biomacromolecules ; 21(2): 376-387, 2020 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-31718163

RESUMO

We report biodegradable thermoplastic polyurethanes for soft tissue engineering applications, where frequently used carboxylic acid ester degradation motifs were substituted with carbonate moieties to achieve superior degradation properties. While the use of carbonates in soft blocks has been reported, their use in hard blocks of thermoplastic polyurethanes is unprecedented. Soft blocks consist of poly(hexamethylene carbonate), and hard blocks combine hexamethylene diisocyanate with the newly synthesized cleavable carbonate chain extender bis(3-hydroxypropylene)carbonate (BHPC), mimicking the motif of poly(trimethylene carbonate) with highly regarded degradation properties. Simultaneously, the mechanical benefits of segmented polyurethanes are exploited. A lower hard block concentration in BHPC-based polymers was more suitable for vascular grafts. Nonacidic degradation products and hard block dependent degradation rates were found. Implantation of BHPC-based electrospun degradable vascular prostheses in a small animal model revealed high patency rates and no signs of aneurysm formations. Specific vascular graft remodeling and only minimal signs of inflammatory reactions were observed.


Assuntos
Materiais Biocompatíveis/química , Prótese Vascular , Cimento de Policarboxilato/química , Poliuretanos/química , Animais , Aorta/patologia , Aorta/cirurgia , Fenômenos Biomecânicos , Isocianatos/química , Espectroscopia de Ressonância Magnética , Teste de Materiais , Microscopia Eletrônica de Varredura , Implantação de Prótese , Ratos Sprague-Dawley , Espectroscopia de Infravermelho com Transformada de Fourier
5.
Artif Organs ; 44(4): E150-E160, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31693191

RESUMO

In heart failure therapy, minimally invasive devices (transcatheter valves, catheter-based cannulas or pumps) are increasingly used. The interaction with the valve is of special importance as valve damage, backflow, and thrombus formation are known complications. Therefore, the aim of this in vitro study was to characterize the forces acting on different sized transvalvular cannulas at various transvalvular pressures for four different valves. In a pulsatile setup radial and tangential forces on transvalvular cannulas were measured for bioprosthetic, artificial pericardial tissue, fresh, and fixated porcine valves. The cannula position was varied from a central position to the wall in 10° rotational steps for the whole circular range and the use of different cannula diameters (4, 6, and 8 mm) and transvalvular pressures (40-100 mmHg). Centering forces of four different aortic valve types were identified and the three leaflets were visible in the force distribution. At the mid of the cusps and at the largest deflection the forces were highest (up to 0.8 N) and lowest in the commissures (up to 0.2 N). Whereas a minor influence of the cannula diameter was found, the transvalvular pressure linearly increased the forces but did not alter the force patterns. Centering forces that act on transvalvular cannulas were identified in an in vitro setup for several valves and valve types. Lowest centering forces were found in the commissures and highest forces were found directly at the cusps. At low pressures, low centering forces and an increased cannula movement can be expected.


Assuntos
Valva Aórtica/fisiologia , Cânula , Coração Auxiliar , Animais , Fenômenos Biomecânicos , Suínos
6.
Artif Organs ; 44(9): 939-946, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32302423

RESUMO

The use of left ventricular assist devices (LVADs) as a treatment method for heart failure patients has been steadily increasing; however, pathological studies showed presence of thrombi around the HeartWare ventricular assist device inflow cannula (IC) in more than 95% of patients after device explantation. Flow fields around the IC might trigger thrombus formation and require further investigation. In this study flow dynamics parameters were evaluated for different patient geometries using computational fluid dynamics (CFD) simulations. Left ventricular (LV) models of two LVAD patients were obtained from CT scans. The LV volumes of Patient 1 (P1) and Patient 2 (P2) were 264 and 114 cm3 with an IC angle of 20° and 9° from the mitral-IC tip axis at the coronal plane. The IC insertion site at the apex was central for P1, whereas it was lateral for P2. Transient CFD simulations were performed over 9 cardiac cycles. The wedge area was defined from the cannula tip to the wall of the LV apex. Mean velocity magnitude and blood stagnation region (volume with mean velocity <5 mm/s) as well as the wall shear stress (WSS) at the IC surface were calculated. Cardiac support resulted in a flow mainly crossing the ventricle from the mitral valve to the LVAD cannula for P2, while the main inflow jet deviated toward the septal wall in P1. Lower WSS at the IC surface and consequently larger stagnation volumes were observed for P2 (P1: 0.17, P2: 0.77 cm3 ). Flow fields around an LVAD cannula can be influenced by many parameters such as LV size, IC angle, and implantation site. Careful consideration of influencing parameters is essential to get reliable evaluations of the apical flow field and its connection to apical thrombus formation. Higher blood washout and lower stagnation were observed for a central implantation of the IC at the apex.


Assuntos
Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Modelos Cardiovasculares , Trombose/prevenção & controle , Idoso , Cânula/efeitos adversos , Simulação por Computador , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica/fisiologia , Humanos , Imageamento Tridimensional , Masculino , Estresse Mecânico , Trombose/etiologia , Tomografia Computadorizada por Raios X
7.
Artif Organs ; 44(3): 239-247, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31519043

RESUMO

Patients supported with a left ventricular assist device (LVAD) have impaired cardiovascular adaptations during exercise, resulting in reduced total cardiac output and exercise intolerance. The aim of this study is to report associations among these impaired cardiovascular parameters and exercise hemodynamics, and to identify in which conditions an LVAD speed increase can provide substantial benefits to exercise. A cardiorespiratory simulator was used to reproduce the average hemodynamics of LVAD patients at exercise. Then, a sensitivity study was conducted where cardiovascular parameters were changed individually ±20% of their baseline value at exercise (heart rate, left/right ventricular contractility, total peripheral resistance, and valve pathologies). Simulations were performed at a baseline LVAD speed of 2700 rpm and repeated at 3500 rpm to evaluate the benefits of a higher LVAD support on hemodynamics. Total cardiac output (TCO) was mostly impaired by a poor left ventricular contractility or vasodilation at exercise (-0.6 L/min), followed by a poor chronotropic response (-0.3 L/min) and by a poor right ventricular contractility (-0.2 L/min). LVAD speed increase better unloads the left ventricle and improves total cardiac output in all the simulated conditions. The most substantial benefits from LVAD speed increase were observed in case of poor left ventricular contractility (TCO + 1.6 L/min) and vascular dysfunction (TCO + 1.4 L/min) followed by lower heart rate (TCO + 1.3 L/min) and impaired right ventricular contractility (TCO + 1.1 L/min). Despite the presence of the LVAD, exercise hemodynamic is strongly depending on the ability of the cardiovascular system to adapt to exercise. A poor left ventricular inotropic response and a poor vascular function can strongly impair cardiac output at exercise. In these conditions, LVAD speed increase can be an effective strategy to augment total cardiac output and unload the left ventricle. These results evidence the need to design a physiological LVAD speed controller, tailored on specific patient's needs.


Assuntos
Exercício Físico , Coração Auxiliar , Hemodinâmica , Simulação por Computador , Frequência Cardíaca , Humanos , Modelos Cardiovasculares , Contração Miocárdica , Função Ventricular Esquerda
8.
Artif Organs ; 44(7): E251-E262, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31945201

RESUMO

Suction of the left ventricle can lead to potentially life-threatening events in left ventricular assist device (LVAD) patients. With the resolution of currently available clinical LVAD monitoring healthcare professionals are unable to evaluate patients' suction occurrences in detail. This study investigates occurrences and durations of suction events and their associations with tachycardia in stable outpatients. Continuous high-resolution LVAD data from HVAD patients were analyzed in the early outpatient period for 15 days. A validated suction detection from LVAD signals was used. Suction events were evaluated as suction rates, bursts of consecutive suction beats, and clusters of suction beats. The occurrence of tachycardia was analyzed before, during, and after suction clusters. Furthermore, blood work, implant strategy, LVAD speed setting, inflow cannula position, left ventricular diameters, and adverse events were evaluated in these patients. LVAD data of 10 patients was analyzed starting at 78 ± 22 postoperative days. Individuals' highest suction rates per hour resulted in a median of 11% (range 3%-61%). Bursts categorized as consecutive suction beats with n = 2, n = 3-5, n = 6-15, and n > 15 beats were homogenously distributed with 10.3 ± 0.8% among all suction beats. Larger suction bursts were followed by shorter suction-free periods. Tachycardia during suction occurred in 12% of all suction clusters. Significant differences in clinical parameters between individuals with high and low suction rates were only observed in left ventricular end-diastolic and end-systolic diameters (P < .02). Continuous high-resolution LVAD monitoring sheds light on outpatient suction occurrences. Interindividual and intraindividual characteristics of longitudinal suction rates were observed. Longer suction clusters have higher probabilities of tachycardia within the cluster and more severe types of suction waveforms. This work shows the necessity of improved LVAD monitoring and the implementation of an LVAD speed control to reduce suction rates and their concomitant burden on the cardiovascular system.


Assuntos
Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Monitorização Hemodinâmica , Complicações Pós-Operatórias/diagnóstico , Idoso , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Sucção , Função Ventricular Esquerda/fisiologia
9.
Artif Organs ; 43(3): 222-228, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30155903

RESUMO

Left ventricular assist devices (LVADs) restore cardiovascular circulatory demand at rest with a spontaneous increase in pump flow to exercise. The relevant contribution of cardiac output provided by the LVAD and ejected through the aortic valve for exercises of different intensities has been barely investigated in patients. The hypothesis of this study was that different responses in continuous recorded pump parameters occur for maximal and submaximal intensity exercises and that the pump flow change has an impact on the oxygen uptake at peak exercise (pVO2 ). Cardiac and pump parameters such as LVAD flow rate (QLVAD ), heart rate (HR), and aortic valve (AV) opening were analyzed from continuously recorded LVAD data during physical exercises of maximal (bicycle ergometer test) and submaximal intensities (6-min walk test and regular trainings). During all exercise sessions, the LVAD speed was kept constant. Cardiac and pump parameter responses of 16 patients for maximal and submaximal intensity exercises were similar for QLVAD : +0.89 ± 0.52 versus +0.59 ± 0.38 L/min (P = 0.07) and different for HR: +20.4 ± 15.4 versus +7.7 ± 5.8 bpm (P < 0.0001) and AV-opening with 71% versus 23% of patients (P < 0.0001). Multi-regression analysis with pVO2 (R2  = 0.77) showed relation to workload normalized by bodyweight (P = 0.0002), HR response (P = 0.001), AV-opening (P = 0.02), and age (P = 0.06) whereas the change in QLVAD was irrelevant. Constant speed LVADs provide inadequate support for maximum intensity exercises. AV-opening and improvements in HR show an important role for higher exercise capacities and reflect exercise intensities. Changes in pump flow do not impact pVO2 and are independent of AV-opening and response in HR. An LVAD speed control may lead to adequate left ventricular support during strenuous physical activities.


Assuntos
Débito Cardíaco/fisiologia , Exercício Físico/fisiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Idoso , Valva Aórtica/fisiologia , Teste de Esforço , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/reabilitação , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
10.
Artif Organs ; 43(5): 458-466, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30375659

RESUMO

Continuous flow left ventricular assist devices (cfLVADS) result in a significant reduction in aortic valve (AV) opening, which has been associated with several complications. Reliable monitoring of AV opening is needed to determine whether pump speed adjustment may be able to minimize adverse outcomes. We assessed AV status continuously by echocardiography for 4 minutes in 3 states in 18 HeartWare HVAD patients: 2 minutes at rest, and 1 minute each following Valsalva maneuver and supine leg-raising. Using a previously described algorithm, beat-to-beat AV status was compared with the area under the curve of the normalized power spectral density analysis (PSD-AUC) for the corresponding beats of the pump speed waveform. Five thousand five hundred twenty-seven beats were analyzed. AV opening varied between 0% and 100% for the cohort with the median AV opening frequency 21.5%, and median duration of opening of 124 msec (range 0-279). The receiver operating characteristic (ROC) curve area for AV opening by the PSD-AUC algorithm was 0.95 (P < 0.0001). A PSD-AUC cut-off of 0.82 distinguished between an open and closed AV with 86% sensitivity and 93% specificity. Accuracy was similar in regular cardiac rhythm, atrial fibrillation or with frequent ventricular ectopic beats. Valsalva maneuver and leg-raising had no impact on accuracy. The PSD-AUC was strongly predictive of AV opening duration (P < 0.0001). We found that AV status and opening duration can be determined with high accuracy on a beat-to-beat basis irrespective of cardiac rhythm and with low level exercise and changes in filling.


Assuntos
Valva Aórtica/fisiopatologia , Coração Auxiliar/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC
11.
Artif Organs ; 42(10): 961-969, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29799135

RESUMO

Ventricular assist devices (VADs) are an established therapeutic option for patients with chronic heart failure. Continuous monitoring of VAD parameters and their adherence to guidelines are crucial to detect problems in an early stage to optimize outcomes. A telephone intervention algorithm for VAD outpatients was developed, clinically implemented and evaluated. During the phone calls, a structured inquiry of pump parameters, alarms, blood pressure, INR, body weight and temperature, exit-site status and heart failure symptoms was performed and electronically categorized by an algorithm into 5 levels of severity. VAD outpatient outcomes without (n = 71) and with bi-weekly telephone interviews in their usual care (n = 25) were conducted using proportional hazard Cox regression, with risk adjustment based on a propensity score model computed from demographics and risk factors. From February 2015 through October 2017, 25 patients (n = 3 HeartMate II, n = 4 HeartMate 3 and n = 18 HeartWare HVAD) underwent 637 telephone interventions. In 57.5% of the calls no problems were identified, 3.9% were recalled on the next day because of alarms. In 26.5% (n = 169), the VAD Coordinator had to refer to the physician due to elevated blood pressure (n = 125, >85 mm Hg), INR < 2.0 or > 4.0 (n = 24) or edema (n = 10), 11.9% of the calls led to a follow-up because of equipment or exit-site problems. Propensity-adjusted 2-year survival (89% vs. 57%, P = 0.027) was significantly higher for the telephone intervention group. Continuous, standardized communication with VAD outpatients is important for early detection of upcoming problems and leads to significantly improved survival.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Idoso , Algoritmos , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Pontuação de Propensão , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Inquéritos e Questionários , Telefone , Resultado do Tratamento
12.
Curr Opin Cardiol ; 31(3): 337-42, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26998788

RESUMO

PURPOSE OF REVIEW: The feasibility and benefits of creating adequate pulsatility with continuous flow left ventricular assist devices (LVADs) have long been debated. This review discusses recent technical and clinical findings to answer whether such intervention should be implemented in the standard patient management. RECENT FINDINGS: Only a limited amount of pulsatility can be generated by periodic speed steps, both considerably smaller in flow increase and in pace rate than the natural circulation. Organ systems are not impeded in their normal function and even not in recovery by a continuous flow. Known problems such as gastrointestinal bleeding are not necessarily due to pulsatility per se, or not important for therapeutic progress, such as minor modifications of the arterial walls. SUMMARY: The speculative benefits of augmented pulsatility with continuous flow LVADs could be overrated and are still incompletely evaluated. Potential risks that might arise from this strategy should be carefully weighed before implementing extensive pulsatility as standard patient management.


Assuntos
Coração Auxiliar , Fluxo Pulsátil , Humanos
13.
Artif Organs ; 40(12): 1113-1120, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27230977

RESUMO

New left ventricular assist devices (LVADs) offer both important advantages and potential hazards. VAD development requires better and expeditious ways to identify these advantages and hazards. We validated in an isolated working heart the hemodynamic performance of an intraventricular LVAD and investigated how its outflow cannula interacted with the aortic valve. Hearts from six pigs were explanted and connected to an isolated working heart setup. A miniaturized LVAD was implanted within the left ventricle (tMVAD, HeartWare Inc., Miami Lakes, FL, USA). In four experiments blood was used to investigate hemodynamics under various loading conditions. In two experiments crystalloid perfusate was used, allowing visualization of the outflow cannula within the aortic valve. In all hearts the transapical miniaturized ventricular assist device (tMVAD) implantation was successful. In the blood experiments hemodynamics similar to those observed clinically were achieved. Pump speeds ranged from 9 to 22 krpm with a maximum of 7.6 L/min against a pressure difference between ventricle and aorta of ∼50 mm Hg. With crystalloid perfusate, central positioning of the outflow cannula in the aortic root was observed during full and partial support. With decreasing aortic pressures the cannula tended to drift toward the aortic root wall. The tMVAD could unload the ventricle similarly to LVADs under conventional cannulation. Aortic pressure influenced central positioning of the outflow cannula in the aortic root. The isolated heart is a simple, accessible evaluation platform unaffected by complex reactions within a whole, living animal. This platform allowed detection and visualization of potential hazards.


Assuntos
Valva Aórtica/fisiopatologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Coração Auxiliar , Animais , Hemodinâmica , Miniaturização , Desenho de Prótese , Implantação de Prótese , Suínos , Função Ventricular Esquerda
14.
J Nutr ; 145(7): 1498-506, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25972522

RESUMO

BACKGROUND: Dietary silicon has been positively linked with vascular health and protection against atherosclerotic plaque formation, but the mechanism of action is unclear. OBJECTIVES: We investigated the effect of dietary silicon on 1) serum and aorta silicon concentrations, 2) the development of aortic lesions and serum lipid concentrations, and 3) the structural and biomechanic properties of the aorta. METHODS: Two studies, of the same design, were conducted to address the above objectives. Female mice, lacking the apolipoprotein E (apoE) gene, and therefore susceptible to atherosclerosis, were separated into 3 groups of 10-15 mice, each exposed to a high-fat diet (21% wt milk fat and 1.5% wt cholesterol) but with differing concentrations of dietary silicon, namely: silicon-deprived (-Si; <3-µg silicon/g feed), silicon-replete in feed (+Si-feed; 100-µg silicon/g feed), and silicon-replete in drinking water (+Si-water; 115-µg silicon/mL) for 15-19 wk. Silicon supplementation was in the form of sodium metasilicate (feed) or monomethylsilanetriol (drinking water). RESULTS: The serum silicon concentration in the -Si group was significantly lower than in the +Si-feed (by up to 78%; P < 0.003) and the +Si-water (by up to 84%; P < 0.006) groups. The aorta silicon concentration was also lower in the -Si group than in the +Si-feed group (by 65%; P = 0.025), but not compared with the +Si-water group. There were no differences in serum and aorta silicon concentrations between the silicon-replete groups. Body weights, tissue wet weights at necropsy, and structural, biomechanic, and morphologic properties of the aorta were not affected by dietary silicon; nor were the development of fatty lesions and serum lipid concentrations. CONCLUSIONS: These findings suggest that dietary silicon has no effect on atherosclerosis development and vascular health in the apoE mouse model of diet-induced atherosclerosis, contrary to the reported findings in the cholesterol-fed rabbit model.


Assuntos
Dieta Hiperlipídica/efeitos adversos , Dieta , Silício/administração & dosagem , Silício/deficiência , Animais , Aorta/efeitos dos fármacos , Aorta/metabolismo , Apolipoproteínas E/genética , Aterosclerose/sangue , Aterosclerose/tratamento farmacológico , Peso Corporal , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Suplementos Nutricionais , Modelos Animais de Doenças , Endotélio Vascular/efeitos dos fármacos , Endotélio Vascular/metabolismo , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Placa Aterosclerótica/sangue , Placa Aterosclerótica/prevenção & controle , Silício/sangue , Triglicerídeos/sangue
15.
Cells Tissues Organs ; 200(5): 287-99, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26372904

RESUMO

Tissue engineering approaches in nerve regeneration search for ways to support gold standard therapy (autologous nerve grafts) and to improve results by bridging nerve defects with different kinds of conduits. In this study, we describe electrospinning of aligned fibrin-poly(lactic-co-glycolic acid) (PLGA) fibers in an attempt to create a biomimicking tissue-like material seeded with Schwann cell-like cells (SCLs) in vitro for potential use as an in vivo scaffold. Rat adipose-derived stem cells (rASCs) were differentiated into SCLs and evaluated with flow cytometry concerning their differentiation and activation status [S100b, P75, myelin-associated glycoprotein (MAG), and protein 0 (P0)]. After receiving the proliferation stimulus forskolin, SCLs expressed S100b and P75; comparable to native, activated Schwann cells, while cultured without forskolin, cells switched to a promyelinating phenotype and expressed S100b, MAG, and P0. Human fibrinogen and thrombin, blended with PLGA, were electrospun and the alignment and homogeneity of the fibers were proven by scanning electron microscopy. Electrospun scaffolds were seeded with SCLs and the formation of Büngner-like structures in SCLs was evaluated with phalloidin/propidium iodide staining. Carrier fibrin gels containing rASCs acted as a self-shaping matrix to form a tubular structure. In this study, we could show that rASCs can be differentiated into activated, proliferating SCLs and that these cells react to minimal changes in stimulus, switching to a promyelinating phenotype. Aligned electrospun fibrin-PLGA fibers promoted the formation of Büngner-like structures in SCLs, which also rolled the fibrin-PLGA matrix into a tubular scaffold. These in vitro findings favor further in vivo testing.


Assuntos
Fibrina/metabolismo , Ácido Láctico/metabolismo , Regeneração Nervosa/fisiologia , Nervos Periféricos/fisiologia , Ácido Poliglicólico/metabolismo , Células de Schwann/citologia , Engenharia Tecidual , Alicerces Teciduais , Animais , Diferenciação Celular/fisiologia , Células Cultivadas , Masculino , Nervos Periféricos/citologia , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Ratos Sprague-Dawley , Engenharia Tecidual/métodos
16.
Artif Organs ; 39(11): 973-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25894522

RESUMO

Low flow rate pumping of cell suspensions finds current applications in bioreactors for short-term dynamic cell culture and adhesion assays. The aim of this study was to develop an atraumatic pump and hemodynamically adapted test circuit to allow operating periods of at least several hours. A computer-controlled mini-pump (MP) was constructed based on non-occlusive local compression of an elastic tube with commercial bi-leaflet valves directing the pulsatile flow into a compliant circuit. Cell damage and activation in the system were tested with whole blood in comparison with a set with a conventional peristaltic pump (PP). Activation of circulating THP-1 monocytes was tested by measuring the expression of CD54 (ICAM-1). Additionally, monocyte-endothelial interactions were monitored using a parallel-plate flow chamber with an artificial stenosis. The system required a priming volume of only 20 mL, delivering a peak pulsatile flow of up to 35 mL/min. After 8 h, blood hemolysis was significantly lower for MP with 11 ± 3 mg/dL compared with PP with 100 ± 16 mg/dL. CD142 (tissue factor) expression on blood monocytes was 50% lower for MP. With MP, THP-1 cells could be pumped for extended periods (17 h), with no enhanced expression of CD54 permitting the long-term co-culture of THP-1 with endothelial cells and the analysis of flow pattern effects on cell adhesion. A low-damage assay setup was developed, which allows the pulsatile flow of THP-1 cells and investigation of their interaction with other cells or surfaces for extended periods of time.


Assuntos
Adesão Celular/fisiologia , Leucócitos/fisiologia , Fluxo Pulsátil , Células Cultivadas , Técnicas de Cocultura , Endotélio Vascular/fisiologia , Hemólise/fisiologia , Humanos , Hidrodinâmica , Técnicas In Vitro , Molécula 1 de Adesão Intercelular/fisiologia , Monócitos/fisiologia , Linfócitos T Auxiliares-Indutores/fisiologia , Tromboplastina/fisiologia
17.
Artif Organs ; 39(8): 704-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26234450

RESUMO

As the aortic valve (AV) opens, the pump pressure head remains constant, which is reflected as a "notch/plateau" in pump pressure and flow signals. However, instantaneous flow estimation may be influenced by friction and is particularly difficult in axial pumps. Therefore, a new method to determine the duration of AV opening based on the area under the curve (AUC) of the power spectral density analysis of pump speed signal was developed. Data from patients implanted with HeartWare HVAD left ventricular assist device were studied at different pump speeds, with simultaneous transthoracic echocardiography in two cohorts. In the first group, pump data of 15 patients were used to investigate the ability to discriminate between an open and closed AV. In the second cohort of a further 13 patients, the duration of AV opening was measured from digitized M-mode images, and the relationship between the AV opening time and the new method assessed. In 14 of the initial 15 patients, AV status could be discriminated using only one threshold for all patients. In the second cohort, gradual speed reduction resulted in aortic valve opening in 12 of the 13 patients. The correlation between AV opening duration and AUC was 0.96 ± 0.03. Regression analysis indicated a linear relationship in each of the patients with a small error between the fit and the measured opening time (root mean square error = 11.0 ± 7.6 ms). However, the slopes (69.0 ± 52.8) and intercepts (-31.4 ± 78.0) varied widely between patients. The sensitivity and specificity for the new method using AUC threshold of 0.95 for aortic valve closure was 95% and 91%, respectively. The newly developed method to detect AV opening not only provides information on the AV status during LVAD support (open/closed) but also gives insight into the duration of AV opening. Because the slope of the relationship varies from patient to patient, initial training and adaptation of the method to each patient seems to be required.


Assuntos
Valva Aórtica/fisiopatologia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Hemodinâmica , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Área Sob a Curva , Áustria , Ecocardiografia Doppler , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , New South Wales , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Curva ROC , Singapura , Fatores de Tempo , Resultado do Tratamento
18.
Artif Organs ; 38(4): 290-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24102321

RESUMO

During left ventricular support by rotary blood pumps (RBPs), the biomechanics of the aortic valve (AV) are altered, potentially leading to adverse events like commissural fusion, valve insufficiency, or thrombus formation. To avoid these events, assessment of AV opening and consequent adaptation of pump speed seem important. Additionally, this information provides insight into the heart-pump interaction. The aim of this study was to develop a method to assess AV opening from the pump flow signal. Data from a numerical model of the cardiovascular system and animal experiments with an RBP were employed to detect the AV opening from the flow waveform under different hemodynamic conditions. Three features calculated from the pump flow waveform were used to classify the state of the AV: skewness, kurtosis, and crest factor. Three different classification algorithms were applied to determine the state of the AV based on these features. In the model data, the best classifier resulted in a percentage of correctly identified beats with a closed AV (specificity) of 99.9%. The percentage of correctly identified beats with an open AV (sensitivity) was 99.5%. In the animal experiments, specificity was 86.8% and sensitivity reached 96.5%. In conclusion, a method to detect AV opening independently from preload, afterload, heart rate, contractility, and degree of support was developed. This algorithm makes the evaluation of the state of the AV possible from pump data only, allowing pump speed adjustment for a frequent opening of the AV and providing information about the interaction of the native heart with the RBP.


Assuntos
Valva Aórtica/cirurgia , Circulação Assistida/instrumentação , Coração Auxiliar , Fluxo Pulsátil , Algoritmos , Animais , Desenho de Equipamento , Hemodinâmica , Ovinos
19.
Artif Organs ; 38(3): 191-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23902542

RESUMO

Monitoring of cardiac rhythms is of major importance in the treatment of heart failure patients with left ventricular assist devices (LVADs) implanted. A continuous surveillance of these rhythms could improve out-of-hospital care in these patients. The aim of this study was to investigate cardiac rhythms using available pump data only. Datasets (n = 141) obtained in the normal ward, in the intensive care unit, and during bicycle ergometry were analyzed in 11 recipients of a continuous flow LVAD (59.1 ± 9.7 years; male 82%). Tachograms and arrhythmic patterns derived from the pump flow waveform, and a simultaneously recorded ECG were compared, as well as heart rate variability parameters such as: the average heart beat duration (RR interval), the standard deviation of the beat duration (SDNN), the root-mean-square of the difference of successive beat durations (RMSSD), and the number of pairs of adjacent beat duration differing by >50 ms divided by the number of all beats (pNN50). A very good agreement of cardiac rhythm parameters from the pump flow compared with ECG was found. Tachycardia, atrial fibrillation, and extrasystoles could be accurately identified from the tachograms derived from the pump flow. Also, Bland-Altman analysis comparing pump flow with ECG indicated a very small difference in average RR interval of 0.3 ± 1.0 ms, in SSDN of 0.5 ± 2.7 ms, in RMSSD of 1.0 ± 5.6 ms, and in pNN50 of 0.3 ± 1.0%. Continuous monitoring of cardiac rhythms from available pump data is possible. It has the potential to reduce the out-of-hospital diagnostic burden and to permit a more efficient adjustment of the level of mechanical support.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Coração Auxiliar , Função Ventricular Esquerda/fisiologia , Idoso , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
20.
Artif Organs ; 38(5): 422-5, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24102417

RESUMO

With increasing support duration of cardiac assist devices, transcutaneous drivelines remain a weak point of the therapy. First, they can be an entry point for infections, and second, cable lesions and even electrical failures due to material fatigue and eventual carelessness can occur. We report a case of a damaged outer sheath of a ventricular assist device driveline cable directly at the exit site, where the standard repair procedure with self-fusing tape may lead to biocompatibility problems and irritation of the entrance through the skin. Therefore, a new procedure was developed using a special sleeve expander tool and a highly expandable latex tubing to stabilize the defect in a flexible and biocompatible manner. A patient experienced a fracture of the outer sheath of a HeartWare HVAD driveline directly at the skin entrance (approximately 15 mm long, 5 mm distal from the skin). The metal strands and the electrical functionality were yet not affected, therefore, a pump exchange was not indicated. After considering several conventional solutions for repair as not applicable, a new approach was developed: a sleeve expander tool was applied, which allowed radial stretching of the latex tubing. After preparations of the tool and the cable site, the pump was briefly disconnected, the tubing was moved over the connector and was released at the site of fracture. The problem could be solved by keeping the cable's flexibility and without additional risks to the skin. Within a still ongoing (5-month) follow-up, the skin entrance returned to perfect condition and no further intervention was necessary. In conclusion, this method allows a quick stabilization and repair of damaged driveline isolations even near the exit site, resulting in a biocompatible surface and consistent flexibility of the cable.


Assuntos
Coração Auxiliar , Idoso , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA