RESUMO
BACKGROUND AND OBJECTIVES: A lateral flow assay for simultaneous blood group typing of ABO, RhD, C, E, c, e, Cw and K with stable end-point and without centrifugation is in routine use since several years (MDmulticard® ). The typing of extended phenotype parameters belonging to the Duffy, Kidd, MNSs blood group systems and others, however, has not yet been demonstrated for this technique. Reliable detection of Fyx , a weak Fyb phenotype with a pronounced quantitative reduction of the number of Fyb antigens on the erythrocyte surface, remains a weakness of current serological blood grouping techniques. MATERIAL AND METHODS: The performance characteristics of the following reagents were evaluated in donor and patient samples in lateral flow technology (MDmulticard® ): Anti-Fya , -Fyb , -Jka , -Jkb , -S, -sÌ , -P1 and -k. The sensitivity to detect Fyx was in addition evaluated with Fyx positive samples, which had been preselected by MALDI-TOF MS-based genotyping. RESULTS: All results obtained with the MDmulticard® were in full accordance with those of the CE-certified reference products for all the eight reagent formulations used: Anti-Fya , -Fyb , -Jka , -Jkb , -S, -sÌ , -P1 and -k. Also, all Fyx phenotypes of the selected population of 93 positive samples, originally identified by MALDI-TOF MS-based genotyping, were reliably detected by the lateral flow assay. CONCLUSION: Extended phenotype blood group parameters, including the serologically challenging Fyx phenotype, can be determined simultaneously, rapidly and accurately using the lateral flow (MDmulticard® ) technology, even in cases when IgG class antibodies are the only source of diagnostic antibodies.
Assuntos
Tipagem e Reações Cruzadas Sanguíneas/métodos , Sistema do Grupo Sanguíneo Duffy/genética , Sistema do Grupo Sanguíneo MNSs/genética , Fenótipo , Tipagem e Reações Cruzadas Sanguíneas/instrumentação , Tipagem e Reações Cruzadas Sanguíneas/normas , Sistema do Grupo Sanguíneo Duffy/classificação , Técnicas de Genotipagem/métodos , Humanos , Sistema do Grupo Sanguíneo MNSs/classificação , Testes Sorológicos/instrumentação , Testes Sorológicos/métodos , Testes Sorológicos/normas , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodosRESUMO
The primary structures and molecular homogeneity of recombinant human epidermal growth factors from different suppliers were characterized and their biological activities evaluated by a standard DNA synthesis assay. Molecular weight determinations using 252Cf-plasma-desorption and electrospray mass spectrometry in combination with N- and C-terminal sequence analysis and determination of intramolecular disulfide bridges revealed that one recombinant protein had the correct human-identical structure (54 aa residues; 6347 Da). In contrast, a second recombinant protein (7020 Da) was found to contain a pentapeptide (KKYPR) insert following its N-terminal methionine. This structural variant showed a significant reduction in its capacity to stimulate DNA synthesis.
Assuntos
Fator de Crescimento Epidérmico/análise , Sequência de Aminoácidos , Animais , DNA/biossíntese , Fator de Crescimento Epidérmico/metabolismo , Humanos , Espectrometria de Massas , Camundongos , Dados de Sequência Molecular , Peso Molecular , Proteínas Recombinantes/análiseRESUMO
ID-PaGIA diphtheria toxin polymer particle diagnostic agent manufactured by DiaMed AG, Switzerland, was tried at bacteriological laboratory of Institute of Childhood Infections in St. Petersburg. The trials were carried out using two methods, direct and capture, which differ by the duration of incubation of the studied C. diphtheriae cultures. Ouchterloney's immunoprecipitation test in agar was the control method. Ninety-seven toxigenic strains were tested by direct test and 76 by capture test; in addition, 19 nontoxigenic strains were tested. The results coincided with control tests in 100% cases. The advantages of each method are defined and the possibility of their utilization at bacteriological laboratories of infectious hospitals and State Sanitary and Epidemiological Surveillance is evaluated.
Assuntos
Toxina Diftérica/análise , Testes de Fixação do Látex/normas , HumanosRESUMO
Transfusion of the 'wrong' stem cell product would almost inevitably be lethal, yet assays to confirm the contents of the product bag, except by checking labels and paperwork, are lacking. To increase the likelihood that a product mix-up would be detected in the transplant center, we developed a simple protocol for extended blood typing and hence, for confirmation of donor/product identity, on a tube segment. Apheresis samples were applied, directly or after erythrocyte enrichment, to commercially available blood typing assays, including lateral flow cards and gel agglutination cards. Without sample modification, low hematocrit and high leukocyte count obviated definitive blood typing. Using the most simple erythrocyte enrichment protocol, that is, centrifugation, reliable blood group analysis became possible with either assay. Other, more cumbersome pre-analytical protocols were also successful but provided no advantage. The preferred method was validated on 100 samples; ABD was correctly identified in 100% of cases. Of the other Rh Ags, all except two 'small e', in both cases in heterozygous individuals, were detected; there were no false positives. A simple, inexpensive point-of-care assay for extended blood typing of apheresis products is available, which can reduce the fatal risk of administering the wrong stem cell product.
Assuntos
Remoção de Componentes Sanguíneos/métodos , Remoção de Componentes Sanguíneos/normas , Tipagem e Reações Cruzadas Sanguíneas/métodos , Tipagem e Reações Cruzadas Sanguíneas/normas , Células-Tronco/citologia , Feminino , Humanos , MasculinoRESUMO
Early and acute diagnosis is needed to prevent thromboembolic complications in heparin-induced thrombocytopenia. We developed a particle agglutination assay that allows the detection of such antibodies within 20 min.
Assuntos
Anticoagulantes/efeitos adversos , Plaquetas/imunologia , Heparina/efeitos adversos , Imunoensaio/métodos , Trombocitopenia/induzido quimicamente , HumanosRESUMO
OBJECTIVE: To describe a new particle agglutination test for the detection of autoantibodies to double stranded DNA (dsDNA). PATIENTS AND METHODS: Serum samples were collected from 40 unselected healthy blood donors and 200 patients with systemic lupus erythematosus (SLE) or a positive antinuclear antibody screen, or both. The samples were tested in the presence of red high density polystyrene particles coated with purified human dsDNA using the gel technique (Micro Typing System, ID-PaGIA, particle gel immunoassay). The results were compared with those obtained by the two standard anti-dsDNA antibody detection methods, Crithidia luciliae immunofluorescence test (CLIF) and enzyme linked immunosorbent assay (ELISA). RESULTS: The three anti-dsDNA assays exhibited an overall agreement of 87% and significant correlation with each other (p<0.0001). In the SLE group (n=71), 45 patients (63%) were found to be positive by ID-PaGIA compared with only 11/129 (9%) patients in the non-SLE group. Thus the ID-PaGIA had a sensitivity of 63%, and a specificity of 92% for SLE. In comparison, the standard detection methods showed sensitivities of 62% (CLIF) and 70% (ELISA) and specificities of 99% (CLIF) and 84% (ELISA) for SLE. Anti-dsDNA reactivity in the agglutination assay correlated closely with the quantities of antibody obtained by CLIF (r=0.81, p<0.0001) and ELISA (r=0.73, p<0.0001). CONCLUSIONS: The new particle gel agglutination test is a sensitive and specific immunoassay. It is a simple test procedure that might be well suited as a rapid screening method.
Assuntos
Anticorpos Antinucleares/análise , DNA/imunologia , Imunoensaio/normas , Testes de Aglutinação/métodos , Cromatografia em Gel/métodos , Cromatografia em Gel/normas , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Imunoensaio/métodos , Lúpus Eritematoso Sistêmico/diagnóstico , Lúpus Eritematoso Sistêmico/imunologia , Microesferas , Sensibilidade e EspecificidadeRESUMO
The major coat protein of native filamentous phage fd is vulnerable to digestion by subtilisin, but not by any of a number of other proteolytic enzymes. Degradation by the non-specific protease subtilisin occurs at specific sites in the N-terminal portion of g8p. The N-terminal part of the protein is considered to be the outer layer of a two-layered coat. Thus, subtilisin treatment results in a monolayered phage particle. These particles possess the morphology and stability of native phage fd. Furthermore, subtilisin proteolysis proved to be an efficient instrument in detecting variations in the topology of the g8p of related filamentous phages.
Assuntos
Bacteriófagos/metabolismo , Capsídeo/metabolismo , Subtilisinas/metabolismo , Sequência de Aminoácidos , Bacteriófagos/ultraestrutura , Capsídeo/química , Fenômenos Químicos , Físico-Química , Eletroquímica , Microscopia Eletrônica , Dados de Sequência Molecular , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismoRESUMO
A rapid screening method for the detection of antiphospholipid antibodies is described. Dense, red dyed polystyrene beads coated with cardiolipin were incubated with test sera for a short period of time, then added to a microtube containing anti-human IgG in a gel provided within a pre-cast card (DiaMed ID Microtyping System). The card was centrifuged at 150g for 5 min and then examined for movement of the beads through the gel. Beads without bound antibody travelled through the gel and formed a pellet on the bottom of the tube. Anti-human IgG within the gel matrix impeded cardiolipin-coated beads when antiphospholipid antibodies bound to the beads. Positivity was indicated by the formation of a layer of beads on the top of the gel matrix. Prospective analysis of 103 samples for the presence of antiphospholipid antibodies by flow cytometry and the gel-card technique showed good correlation between the two methods. All samples found to be positive by flow cytometry (23 of 103) were identified as positive by the gel-card technique. Two samples were identified as positive by the gel-card method but negative by flow cytometry. The technique is simple to perform and should prove useful as a rapid screening method for the detection of antiphospholipid antibodies.
Assuntos
Anticorpos Anticardiolipina/análise , Síndrome Antifosfolipídica/diagnóstico , Síndrome Antifosfolipídica/imunologia , Géis , Humanos , Métodos , PoliestirenosRESUMO
A total of 70 serum samples from heparin-induced thrombocytopenia (HIT II) patients, non-HIT patients and healthy subjects, respectively, were studied for the presence of antiheparin/PF4 antibodies. Two enzyme-linked immunosorbent assay (ELISA) assays were compared with the particle gel immunoassay (PaGIA). Beads of the PaGIA kit were also used to evaluate the feasibility of flow cytometric detection of antiheparin/PF4 antibodies in patient samples. Experiments have shown that all samples found positive by ELISA and PaGIA, were also positive when analysed by flow cytometry by an indirect test using the high-density particles coated with heparin/PF4 complexes and a second step fluorescein isothiocyanate (FITC) antihuman immunoglobulin (Ig)G reagent. The procedure was easy to perform, repetitive and beads were promptly visualized by physical parameters, with a very low background. In conclusion, the results of this study suggest that flow cytometry is a reliable method for the detection of antiheparin/PF4 antibodies.
Assuntos
Autoanticorpos/sangue , Heparina/imunologia , Fator Plaquetário 4/imunologia , Trombocitopenia/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Citometria de Fluxo/normas , Heparina/efeitos adversos , Humanos , Isotipos de Imunoglobulinas/sangue , Testes de Fixação do Látex/normas , Masculino , Microesferas , Pessoa de Meia-Idade , Trombocitopenia/induzido quimicamente , Trombocitopenia/imunologiaRESUMO
BACKGROUND AND OBJECTIVES: Antibodies to immunoglobulin A (IgA) molecules are thought to be frequently responsible for anaphylactic reactions in transfusion medicine, but practical tests for the detection of antibodies to IgA are not yet available. MATERIAL AND METHODS: Red, high-density polystyrene beads were coated with purified IgA molecules and then used to test serum samples collected from unselected healthy blood donors (n = 105) and patients with common variable immunodeficiency and/or IgA deficiency (n = 44). For testing, the standard gel-agglutination technique (ID-Micro Typing System) was employed. RESULTS: None of the normal serum samples were reactive with IgA-coated beads and samples from only 10 patients were positive (titre range 1 : 2 to 1 : 256). Only one out of all patients studied had a history of an anaphylactic reaction and this was related to the administration of Rh(D) prophylaxis (anti-D immunoglobulin). The beads did not show non-specific agglutination and could be used repeatedly for longer than 6 months. The results were reproducible in all patients tested. CONCLUSION: The new test allows a specific and rapid detection of antibodies to IgA molecules. In order to evaluate the clinical relevance of the test, analysis is required of a wider range of antibodies that produce anaphylactic reactions.
Assuntos
Anticorpos Anti-Idiotípicos/sangue , Deficiência de IgA/diagnóstico , Adulto , Criança , Cromatografia em Gel , Imunodeficiência de Variável Comum/sangue , Imunodeficiência de Variável Comum/tratamento farmacológico , Feminino , Humanos , Deficiência de IgA/tratamento farmacológico , Imunoensaio/métodos , Imunoglobulina A/imunologia , Imunoglobulinas Intravenosas/administração & dosagem , Imunoglobulinas Intravenosas/farmacologia , Masculino , Microesferas , Pessoa de Meia-Idade , Fatores de TempoRESUMO
The ID-Chagas test is a particle gel immunoassay (PaGIA). Red coloured particles are sensitised with three different synthetic peptides representing antigen sequences of Trypanosoma cruzi: Ag2, TcD and TcE. When these particles are mixed with serum containing specific antibodies, they agglutinate. The reaction mixture is centrifuged through a gel filtration matrix allowing free agglutinated particles to remain trapped on the top or distributed within the gel. The result can be read visually. In order to investigate the ability of the ID-PaGIA to discriminate negative and positive sera, 111 negative and 119 positive, collected in four different Brazilian institutions, were tested by each of the participants. All sera were previously classified as positive or negative according to results obtained with three conventional tests (indirect immunofluorescence, indirect hemaglutination, and enzyme linked immunosorbent assay). Sensitivity rates of ID-PaGIA varied from 95.7% to 97.4% with mean sensitivity of 96.8% and specificity rates varied from 93.8 to 98.8% with mean specificity of 94.6%. The overall Kappa test was 0.94. The assay presents as advantages the simplicity of operation and the reaction time of 20 min. In this study, ID-PaGIA showed to be highly sensitive and specific.