Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Eur Spine J ; 27(9): 2213-2222, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30039256

RESUMO

PURPOSE: Neuromuscular scoliosis (NS) is a complicated spinal disorder, and it could be treated through posterior-only approach (POA) or combined anterior-posterior approach (APA), which one is better and how to choose the surgical tactic is still in controversy. So comparing POA with APA parameters in the treatment of NS is meaningful. METHODS: Database of PubMed, Embase and Cochrane Library was systematically searched, and the studies, which focus on the comparisons of POA and APA in the treatment of NS, were included. The meta-analysis was performed by RevMan 5.3. RESULTS: Seven retrospective studies with 602 patients were included in meta-analysis. In previous analysis, statistically significant differences were observed in the major parameters between APA and POA. However, the results of subgroup meta-analysis, which focused on the correction angle and loss angle to eliminate the influence of different preoperative angles, were tend to no difference between two groups, except loss angle of scoliosis (MD, 6.4; 95% CI - 0.19 to 13) and correction angle of pelvic obliquity (MD, - 3.44; 95% CI - 6.71 to - 0.17). CONCLUSIONS: Our meta-analysis suggested that POA was similar to APA in the correction of scoliosis in coronal and sagittal planes. However, APA had advantages in the correction of pelvic obliquity and decreasing the loss of angle between postoperation and follow-up in main scoliosis, whereas POA had advantages in operative time, blood loss, duration of hospital stay and complications. LEVEL OF EVIDENCE: Level II. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Procedimentos Ortopédicos , Escoliose , Humanos , Tempo de Internação , Duração da Cirurgia , Procedimentos Ortopédicos/efeitos adversos , Procedimentos Ortopédicos/métodos , Procedimentos Ortopédicos/estatística & dados numéricos , Complicações Pós-Operatórias , Amplitude de Movimento Articular , Escoliose/fisiopatologia , Escoliose/cirurgia , Coluna Vertebral/fisiopatologia , Coluna Vertebral/cirurgia
2.
Eur Spine J ; 24(4): 852-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25391624

RESUMO

PURPOSE: To design and investigate a novel technique of percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion. METHODS: CT scans of 45 patients were collected and imported into Mimics software for three-dimensional (3D) reconstruction. Cylinders were drawn to simulate the trajectory of the oblique screw. Six measurements were obtained for each unit to design a right size cage: a the distance between the intersection of the simulated trajectory of the screw with the inferior border of the upper vertebra and its anteroinferior corner; b the distance between the intersection of the simulated trajectory of the screw with the superior border of the inferior vertebra and its anterosuperior corner; h the height of the intervertebral space; θ the angle between simulated trajectory of screw and the upper endplate of inferior vertebra; uw: the width of the inferior endplate of upper vertebra; iw: the width of upper endplate of inferior vertebra. Three intact adult fresh-frozen cadaveric specimens were obtained, percutaneous posterior transdiscal oblique screw fixation was performed under X-ray apparatus, and interbody cage was implanted by assistance with special self-retaining retractor system and endoscope. RESULTS: According to the results of data measured from 3D images, trapezoid shape interbody cages with suitable size were designed. Percutaneous posterior oblique screw fixation with lateral interbody fusion was performed on three cadaveric specimens successfully. CONCLUSION: Using specially designed trapezoid shape interbody cages, assisted by intra-operative image intensification and endoscope, it is feasible to perform percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion technique.


Assuntos
Parafusos Ósseos/efeitos adversos , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Adulto , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Tomografia Computadorizada por Raios X
4.
Orthop Surg ; 14(2): 443-450, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34914198

RESUMO

This study sought to investigate and evaluate a modified axial translaminar screw fixation for treating odontoid fractures. We performed a retrospective study at Wenzhou Medical University Affiliated Second Hospital between March 2016 and June 2018. We retrospectively collected and analyzed the medical records of 23 cases with odontoid fractures. All patients were identified as type II odontoid fractures without neurological deficiency and serious diseases following the classification of Anderson. The average age, gender ratio, and body mass index (BMI) were 54.3 ± 11.1 years, 12 men to 11 women, and 22.6 ± 2.4 kg/m2 , respectively. Patients in this study accepted screw fixation using our modified axial translaminar screw fixation combined with atlas pedicle or lateral mass screw fixation. Within the technique, a small cortical "window" was dug in the middle of the axial contralateral lamina, such that the screws in the lamina were visualized to prevent incorrectly implanting the posterior spinal canal through the visualized "window." A total of 46 bone screws were accurately inserted into the axial lamina without using fluoroscopy. The length of all translaminar screws ranged between 26 and 30 mm, while the diameter was 3.5 mm. During the follow-up survey, the visual analog scale (VAS) and neck disability index (NDI) were measured. We provide a simple modification of Wright's elegant technique with the addition of "visualized windows" at the middle of the axial lamina. In all patients, screws were inserted accurately without bony breach and the screw angle was 56.1 ± 3.0°. Mean operative time was 102 ± 28 min with an average blood loss of 50 ± 25 mL. Postoperative hemoglobin and mean length of hospital stay were 12.0 ± 1.4 g/dL and 10.4 ± 3.4 days, respectively. The average follow-up time of all cases was 14.7 months and no internal fixation displacement, loosening, or breakage was found. All patients with odontoid fractures reported being satisfied with the treatment during the recheck period and good clinical outcomes were observed. At 1, 6, and 12 months, NDI and VAS showed that the symptoms of neck pain and limitations of functional disability improved significantly during follow-up. Our results suggest that the modified translaminar screw fixation technique can efficiently treat Anderson type II odontoid fracture, followed by the benefits of less soft tissue dissection, simple operation, no fluoroscopy, and accurate placement of screws.


Assuntos
Processo Odontoide , Fraturas da Coluna Vertebral , Fusão Vertebral , Adulto , Idoso , Parafusos Ósseos , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Processo Odontoide/diagnóstico por imagem , Processo Odontoide/lesões , Processo Odontoide/cirurgia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fusão Vertebral/métodos , Resultado do Tratamento
5.
Int Immunopharmacol ; 78: 105953, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31784401

RESUMO

Osteoarthritis(OA) is one of the most common diseases in orthopedics. It is characterized by degeneration of articular cartilage and chronic inflammation. In this study, we aim to elucidate the mechanism of Loureirin A's therapeutic effect in OA progression. In vitro, Loureirin A pretreatment can significantly inhibit production of NO, PGE2, COX-2, TNF-α, iNOS andIL-6 induced by IL-1ß in mouse articular chondrocytes. Moreover, Loureirin A suppressed the expression of matrix metalloproteinase-9(MMP-9), which leads to degradation of the extracellular matrix. The degradation of aggrecan and type II collagen protein in the extracellular matrix (ECM) stimulated by IL-1ß was reversed. For signal pathway research, Loureirin A dramatically inhibited the phosphorylation of AKT and subsequent NF-κB entering into the nucleus caused by IL-1ß in chondrocytes. Besides, a number of related indicators suggested that Loureirin A has a strong antioxidant activity in the treatment of osteoarthritis via increasing content of SOD2 and suppressing MDA and ROS. In addition, in vivo study demonstrated that Loureirin A could ameliorated the progression of OA in mice DMM model In conclusion, all results showed that Loureirin A may be a potential therapeutic candidate for the OA.


Assuntos
Anti-Inflamatórios/uso terapêutico , Antioxidantes/uso terapêutico , Chalconas/uso terapêutico , Osteoartrite/tratamento farmacológico , Animais , Anti-Inflamatórios/farmacologia , Antioxidantes/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Chalconas/farmacologia , Condrócitos/efeitos dos fármacos , Condrócitos/metabolismo , Condrócitos/patologia , Regulação para Baixo/efeitos dos fármacos , Matriz Extracelular/efeitos dos fármacos , Feminino , Masculino , Malondialdeído/metabolismo , Camundongos Endogâmicos C57BL , NF-kappa B/metabolismo , Osteoartrite/metabolismo , Proteínas Proto-Oncogênicas c-akt/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Transdução de Sinais/efeitos dos fármacos , Superóxido Dismutase/metabolismo
6.
World Neurosurg ; 122: e48-e58, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30236812

RESUMO

BACKGROUND: Cervical sagittal imbalance compromises health-related quality of life and can lead to myriad incapacitating symptoms through compression of the spinal cord. Questions regarding which parameters play primary roles in the progression of cervical sagittal imbalance and which might be compensatory factors remain unanswered. METHODS: This study enrolled 246 asymptomatic volunteers from July 2016 to June 2018. After demographic and radiologic parameters were measured, the data were analyzed using correlation coefficient test and multiple regression analysis. A predictive equation was assessed with variance analysis, residual analysis, collinearity analysis, and a paired t test. RESULTS: Average values are as follows: orbital tilt, 64 ± 6°; orbital slope (OS), 15 ± 6°; C0-C2 lordosis (C0C2), 28 ± 8°; cervical lordosis (CL), 5 ± 11°; C2-C7 sagittal vertical axis (C2C7SVA), 15 ± 8 mm; T1 slope (TS), 17 ± 6°; thoracic inlet angle, 69 ± 8°; thoracic kyphosis, 34 ± 9°; lumbar lordosis, 50 ± 10°; sacral slope, 38 ± 7°; pelvic index, 48 ± 9°; sagittal vertical axis, 10 ± 19 mm. Correlations of C2C7SVA were observed with body mass index (BMI), OS, C0C2, CL, and TS. The validated predictive equation was: C2C7SVA = 0.38 × BMI - 0.73 × OS + 0.73 × C0C2 + 0.15 × CL + 0.18 × TS - 6.53. CONCLUSIONS: BMI, OS, C0C2, CL, and TS were primary influencers in the progression of cervical sagittal imbalance and established a predictive equation of asymptomatic population, which can provide clinical advice and remind surgeons of the primary influencers of reconstructive surgery for better prognoses.


Assuntos
Vértebras Cervicais/diagnóstico por imagem , Curvaturas da Coluna Vertebral/diagnóstico por imagem , Idoso , Índice de Massa Corporal , Progressão da Doença , Feminino , Humanos , Masculino , Dados Preliminares , Análise de Regressão , Curvaturas da Coluna Vertebral/epidemiologia
7.
World Neurosurg ; 120: e488-e496, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30149177

RESUMO

OBJECTIVE: We sought to acquire the whole sagittal spine parameters and investigated the acceptable chin-brow vertical angle (CBVA) for neutral position radiography in an asymptomatic Chinese population. METHODS: The parameters measured in 257 asymptomatic volunteers included CBVA, occipital slope, orbital tilt, occipital incidence, C0-C2 Cobb angle, C2-C7 Cobb angle, C1-C7 Cobb angle, C2-C7 sagittal vertical axis and absolute rotation angle, cervical tilt, cranial tilt, T1 slope, and thoracic kyphosis, and others. We used Pearson correlation analyses to find relationships between CBVA and other variables. The subjects were divided into 5 groups according to the CBVA percentile: group A, 0%-20% CBVA; group B, 20%-40% CBVA; group C, 40%-60% CBVA; group D, 60%-80% CBVA; and group E, 80%-100% CBVA. We used analysis of variance to analyze differences among the 5 groups. RESULTS: Orbital tilt, Occipital incidence, C1-C7 Cobb angle, C2-C7 sagittal vertical axis, and cranial tilt all increased with increasing CBVA (P < 0.001). The occipital slope, C2-C7 Cobb angle, C2-C7 absolute rotation angle, cervical tilt, T1 slope, and thoracic kyphosis decreased with decreasing CBVA (P < 0.05). No correlations between other sagittal parameters and the CBVA were found. A slight deviation was found in groups B-D, with a greater deviation in groups A, C, and E. CONCLUSIONS: An acceptable range of -1.5° to 5.8° is recommended for the CBVA for cervical radiography in the neutral position. When spinal surgeons evaluate the cervical plane, the effects of the CBVA deviation on cervical curvature must be considered.


Assuntos
Queixo/anatomia & histologia , Sobrancelhas/anatomia & histologia , Radiografia/métodos , Coluna Vertebral/diagnóstico por imagem , Adulto , Idoso , Povo Asiático , Vértebras Cervicais/diagnóstico por imagem , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Cifose/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Estudos Retrospectivos , Adulto Jovem
8.
J Orthop Surg Res ; 13(1): 124, 2018 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-29792213

RESUMO

BACKGROUND: An increasing number of studies on spinal morphology in asymptomatic Asian and Western patients have been reported. Variation in spinal anatomy among patients is considered as the cause of wrong-level surgery in up to 40% of cases. The present study examined the rate of presence of 11 thoracic vertebrae and 6 lumbar vertebrae in 293 asymptomatic Chinese adult volunteers. METHODS: From May 27, 2016, to November 11, 2017, a cohort of 325 asymptomatic Chinese adults meeting the study exclusion criteria was recruited. The radiographs were examined by a spine surgeon and a radiologist to assess the number of thoracic and lumbar vertebrae. RESULTS: In total, 293 volunteers were included in this study: 17 (5.8%) had 11 thoracic vertebrae, and 16 (5.5%) had 6 lumbar vertebrae. Among all volunteers, 12 (4.1%) had 7 cervical vertebrae (C), 11 thoracic vertebrae (T), and 5 lumbar vertebrae (L); 5 (1.7%) had 7C, 11T, and 6L; and 11 (3.8%) had 7C, 12T, and 6L. There was no difference between the findings of the spine surgeon and the radiologist. CONCLUSIONS: For the first time, this study describes the rate of presence of 11 thoracic vertebrae and 6 lumbar vertebrae in 293 asymptomatic Chinese adult volunteers. Variations in the number of thoracic and lumbar vertebrae tend to be ignored by spine surgeons. We encourage spinal surgeons and researchers to be aware of such variations when performing thoracic- and lumbar-level surgery and assessing spinal alignment and parameters.


Assuntos
Doenças Assintomáticas/epidemiologia , Vértebras Lombares/anormalidades , Vértebras Lombares/diagnóstico por imagem , Vértebras Torácicas/anormalidades , Vértebras Torácicas/diagnóstico por imagem , Adulto , China/epidemiologia , Estudos de Coortes , Feminino , Voluntários Saudáveis , Humanos , Masculino
9.
PeerJ ; 5: e3564, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28717599

RESUMO

Transpedicular transdiscal screw fixation is an alternative technique used in lumbar spine fixation; however, it requires an accurate screw trajectory. The aim of this study is to design a novel 3D-printed custom drill guide and investigate its accuracy to guide the trajectory of transpedicular transdiscal (TPTD) lumbar screw fixation. Dicom images of thirty lumbar functional segment units (FSU, two segments) of L1-L4 were acquired from the PACS system in our hospital (patients who underwent a CT scan for other abdomen diseases and had normal spine anatomy) and imported into reverse design software for three-dimensional reconstructions. Images were used to print the 3D lumbar models and were imported into CAD software to design an optimal TPTD screw trajectory and a matched custom drill guide. After both the 3D printed FSU models and 3D-printed custom drill guide were prepared, the TPTD screws will be guided with a 3D-printed custom drill guide and introduced into the 3D printed FSU models. No significant statistical difference in screw trajectory angles was observed between the digital model and the 3D-printed model (P > 0.05). Our present study found that, with the help of CAD software, it is feasible to design a TPTD screw custom drill guide that could guide the accurate TPTD screw trajectory on 3D-printed lumbar models.

10.
BMJ Open ; 7(7): e016328, 2017 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-28733301

RESUMO

INTRODUCTION: The incidence of lumbar disc degeneration disease has increased in recent years. Lumbar interbody fusion using two unilateral pedicle screws and a translaminar facet screw fixation has advantages of minimal invasiveness and lower costs compared with the traditional methods. Moreover, a method guided by a three-dimensional (3D) navigation template may help us improve the surgical accuracy and the success rate. This is the first randomised study using a 3D navigation template to guide a unilateral lumbar pedicle screw with contralateral translaminar facet screw fixation. METHODS AND ANALYSIS: Patients who meet the criteria of the surgery will be randomly divided into experimental groups and control groups by a computer-generated randomisation schedule. We will preoperatively design an individual 3D navigation template using CATIA software and MeditoolCreate. The following primary outcomes will be collected: screw angles compared with the optimal screw trajectories in 3D digital images, length of the wound incision, operative time, intraoperative blood loss and complications. The following secondary outcomes will be collected: visual analogue scale (VAS) for back pain, VAS for leg pain and the Oswestry Disability Index. These parameters will be evaluated on day 1 and then 3, 6, 12 and 24 months postoperatively. ETHICS AND DISSEMINATION: The study has been reviewed and approved by the institutional ethics review board of the Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University. The results will be presented at scientific communities and peer-reviewed journals. TRIAL REGISTRATION NUMBER: ChiCTR-IDR-17010466.


Assuntos
Parafusos Ósseos , Imageamento Tridimensional , Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Região Lombossacral/cirurgia , Fusão Vertebral/métodos , Adulto , Idoso , Custos e Análise de Custo , Hemorragia , Humanos , Degeneração do Disco Intervertebral/complicações , Complicações Intraoperatórias , Vértebras Lombares/patologia , Região Lombossacral/patologia , Pessoa de Meia-Idade , Duração da Cirurgia , Dor/etiologia , Medição da Dor , Parafusos Pediculares , Projetos de Pesquisa , Resultado do Tratamento , Adulto Jovem
11.
Oncotarget ; 8(24): 39849-39858, 2017 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-28418890

RESUMO

Hip fracture has increasingly become a social and economic burden. The relationship between serum 25-hydroxyvitamin D levels and the risk of hip fracture reported by previous studies remains controversial. We searched Pubmed and Embase to identify studies reporting the relationship between serum 25-hydroxyvitamin D levels and risk of hip fracture. Fifteen prospective cohort studies with a total of 51239 participants and 3386 hip fracture cases were included. By pooling the Relative Risk of the lowest vs. the highest categories indicated that lower levels of serum 25-hydroxyvitamin D were more likely to be a risk factor for hip fracture with adjusted Relative Risk (95%Confidence Interval) of 1.58 (1.41, 1.77). Subgroup meta-analysis examining the stability of the primary results achieved the same results. A dose-response meta-analysis showed that the risk of hip fracture was a descending curve below the line of RR=1. The descending trend was obvious when serum 25-hydroxyvitamin D levels were less than 60 nmol/L and was flat when serum 25-hydroxyvitamin D levels were more than 60 nmol/L. We found that individuals with low levels of serum 25-hydroxyvitamin D have an increased risk of hip fracture, and this effect was evident when the serum 25-hydroxyvitamin D levels were less than 60 nmol/L.


Assuntos
Fraturas do Quadril/sangue , Fraturas do Quadril/epidemiologia , Vitamina D/análogos & derivados , Humanos , Prevalência , Estudos Prospectivos , Fatores de Risco , Vitamina D/sangue
12.
PLoS One ; 10(4): e0124291, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25915641

RESUMO

BACKGROUND: To study the morphology of the human spine and new spinal fixation methods, scientists require cadaveric specimens, which are dependent on donation. However, in most countries, the number of people willing to donate their body is low. A 3D printed model could be an alternative method for morphology research, but the accuracy of the morphology of a 3D printed model has not been determined. METHODS: Forty-five computed tomography (CT) scans of cervical, thoracic and lumbar spines were obtained, and 44 parameters of the cervical spine, 120 parameters of the thoracic spine, and 50 parameters of the lumbar spine were measured. The CT scan data in DICOM format were imported into Mimics software v10.01 for 3D reconstruction, and the data were saved in .STL format and imported to Cura software. After a 3D digital model was formed, it was saved in Gcode format and exported to a 3D printer for printing. After the 3D printed models were obtained, the above-referenced parameters were measured again. RESULTS: Paired t-tests were used to determine the significance, set to P<0.05, of all parameter data from the radiographic images and 3D printed models. Furthermore, 88.6% of all parameters of the cervical spine, 90% of all parameters of the thoracic spine, and 94% of all parameters of the lumbar spine had Intraclass Correlation Coefficient (ICC) values >0.800. The other ICC values were <0.800 and >0.600; none were <0.600. CONCLUSION: In this study, we provide a protocol for printing accurate 3D spinal models for surgeons and researchers. The resulting 3D printed model is inexpensive and easily obtained for spinal fixation research.


Assuntos
Imageamento Tridimensional , Modelos Anatômicos , Impressão Tridimensional , Coluna Vertebral/anatomia & histologia , Adulto , Vértebras Cervicais/anatomia & histologia , Vértebras Cervicais/diagnóstico por imagem , Humanos , Vértebras Lombares/anatomia & histologia , Vértebras Lombares/diagnóstico por imagem , Pessoa de Meia-Idade , Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/anatomia & histologia , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X
13.
Medicine (Baltimore) ; 93(28): e242, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25526447

RESUMO

Anterior occiput-to-axis screw fixation is more suitable than a posterior approach for some patients with a history of posterior surgery. The complex osseous anatomy between the occiput and the axis causes a high risk of injury to neurological and vascular structures, and it is important to have an accurate screw trajectory to guide anterior occiput-to-axis screw fixation. Thirty computed tomography (CT) scans of upper cervical spines were obtained for three-dimensional (3D) reconstruction. Cylinders (1.75 mm radius) were drawn to simulate the trajectory of an anterior occiput-to-axis screw. The imitation screw was adjusted to 4 different angles and measured, as were the values of the maximized anteroposterior width and the left-right width of the occiput (C0) to the C1 and C1 to C2 joints. Then, the 3D models were printed, and an angle guide device was used to introduce the screws into the 3D models referring to the angles calculated from the 3D images. We found the screw angle ranged from α1 (left: 4.99±4.59°; right: 4.28±5.45°) to α2 (left: 20.22±3.61°; right: 19.63±4.94°); on the lateral view, the screw angle ranged from ß1 (left: 13.13±4.93°; right: 11.82±5.64°) to ß2 (left: 34.86±6.00°; right: 35.01±5.77°). No statistically significant difference was found between the data of the left and right sides. On the 3D printed models, all of the anterior occiput-to-axis screws were successfully introduced, and none of them penetrated outside of the cortex; the mean α4 was 12.00±4.11 (left) and 12.25±4.05 (right), and the mean ß4 was 23.44±4.21 (left) and 22.75±4.41 (right). No significant difference was found between α4 and ß4 on the 3D printed models and α3 and ß3 calculated from the 3D digital images of the left and right sides. Aided with the angle guide device, we could achieve an optimal screw trajectory for anterior occiput-to-axis screw fixation on 3D printed C0 to C2 models.


Assuntos
Vértebras Cervicais/diagnóstico por imagem , Simulação por Computador , Fixação Interna de Fraturas/métodos , Processamento de Imagem Assistida por Computador , Fraturas da Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X/métodos , Parafusos Ósseos , Vértebras Cervicais/lesões , Vértebras Cervicais/cirurgia , Estudos de Viabilidade , Humanos , Reprodutibilidade dos Testes , Fraturas da Coluna Vertebral/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA