Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Circ J ; 88(7): 1081-1088, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38281763

RESUMO

BACKGROUND: The impact of sleep apnea (SA) on heart rate variability (HRV) in atrial fibrillation (AF) patients has not been investigated.Methods and Results: Of 94 patients who underwent AF ablation between January 2021 and September 2022, 76 patients who had a nocturnal Holter electrocardiography and polysomnography conducted simultaneously were included in the analysis. A 15-min duration of HRV, as determined by an electrocardiogram during apnea and non-apnea time, were compared between patients with and without AF recurrence at 12 months' postoperatively. Patients had a mean age of 63.4±11.6 years, 14 were female, and 20 had AF recurrence at 12 months' follow-up. The root mean square of the difference between consecutive normal-to-normal intervals (RMSSD, ms) an indicator of a parasympathetic nervous system, was more highly increased in patients with AF recurrence than those without, during both apnea and non-apnea time (apnea time: 16.7±4.5 vs. 13.5±3.3, P=0.03; non-apnea time: 20.9±9.5 vs. 15.5±5.9, P<0.01). However, RMSSD during an apneic state was decreased more than that in a non-apneic state in both groups of patients with and without AF recurrence (AF recurrence group: 16.7±4.5 vs. 20.9±9.5, P<0.01; non-AF recurrence group; 13.5±3.3 vs. 15.5±5.9, P=0.03). Consequently, the effect of AF recurrence on parasympathetic activity was offset by SA. Similar trends were observed for other parasympathetic activity indices; high frequency (HF), logarithm of HF (lnHF) and the percentage of normal-to-normal intervals >50 ms (pNN50). CONCLUSIONS: Without considering the influence of SA, the results of nocturnal HRV analysis might be misinterpreted. Caution should be taken when using nocturnal HRV as a predictor of AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Eletrocardiografia Ambulatorial , Frequência Cardíaca , Sistema Nervoso Parassimpático , Síndromes da Apneia do Sono , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Pessoa de Meia-Idade , Feminino , Masculino , Idoso , Síndromes da Apneia do Sono/fisiopatologia , Sistema Nervoso Parassimpático/fisiopatologia , Recidiva , Polissonografia
2.
Heart Vessels ; 38(5): 691-698, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36441215

RESUMO

Balloon ablation therapy has recently been used for atrial fibrillation (AF) ablation. Laser balloons possess the property in which the balloon size can be changed. Standard laser balloon ablation (Standard LBA) was followed by additional ablation using a maximally extended balloon (Extended LBA) and its lesion characteristics were compared to cryoballoon ablation (CBA), another balloon technology. From June 2020 to July 2021, patients with paroxysmal AF who underwent an initial pulmonary vein (PV) isolation were enrolled. Sixty-five patients with paroxysmal AF were included, 32 in the LBA and 33 in the CBA group. To measure the isolated surface area after the ablation procedures, left atrial voltage mapping was performed after Standard LBA, Extended LBA, and CBA. The baseline patient characteristics did not differ between LBA and CBA. Extended LBA could successfully increase the isolated area more than Standard LBA for all four PVs. Compared to CBA, the isolated area of both superior PVs was significantly greater with Extended LBA (left superior PV: 8.5 ± 2.1 vs 7.3 ± 2.4, p = 0.04, right superior PV: 11.4 ± 3.7 vs 8.7 ± 2.7, p < 0.01), and thus the non-isolated posterior wall (PW) was smaller (8.5 ± 3.4 vs 12.4 ± 3.3, p < 0.01). Nevertheless, changes in the cardiac injury markers were significantly lower with LBA than CBA. There was no significant correlation between the cardiac injury level and isolated area in both groups. In conclusion, Extended LBA exhibited a significantly greater isolation of both superior PVs and resulted in a smaller non-isolated PW, but the cardiac injury markers were significantly suppressed as compared to CBA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Lasers
3.
Clin Case Rep ; 12(5): e8718, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38681029

RESUMO

Key Clinical Message: This case highlights the pitfalls and provides tips for the extraction of deeply implanted lumenless leads, and encourages careful lead selection in the current era of widespread left bundle branch area pacing. Abstract: The extraction of cardiovascular implantable electronic device leads is sometimes complicated. We describe a case with difficult but successful extraction of SelectSecure, a lumenless permanent pacemaker lead, implanted deep in the ventricular septum, highlighting its pitfalls and tips in the current era of left bundle branch area pacing.

4.
Int J Cardiol Heart Vasc ; 44: 101177, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36820388

RESUMO

Background: This multicenter prospective observational study examined the impact of additionally using a home electrocardiograph (ECG) to detect atrial fibrillation (AF) recurrence after ablation. Methods: Between May 2019 and December 2020, 128 patients undergoing ablation were enrolled in the study. After performing ablation, they were instructed to measure their ECGs at home using Complete (ECG paired with a blood pressure monitor; Omron Healthcare, Japan) every day and to visit the hospital every 3 months until after 12 months for 24-hour Holter ECG and 12-lead ECG as usual care (UC). Results: After ablation, 94 patients were followed up, and AF recurrence at 12 months was detected more commonly in adjudicators-interpreted Complete (31 [33 %]) than in UC (18 [9 %]) (hazard ratio 1.95, 95 % confidence interval [95 %CI] 1.35-2.81, P < 0.001). In patients with recurrent AF found via both modalities (n = 16), the time to first AF detection by Complete was 40.9 ± 73.9 days faster than that in UC (P = 0.04). Notably, when the adherence to Complete measurement was divided by 80 %, the add-on effect of Complete on the detection of recurrent AF in UC indicated the hazard ratio (HR) of 1.71 (95 %CI 0.92-3.18, P = 0.09) for the low adherence (<80 %) group, but it was significant for the high adherence (≥80 %) group, with HR of 2.19 (95 %CI 1.43-3.36, P < 0.001). Conclusions: Despite a shorter measurement time, Complete detected recurrent AF more frequently and faster compared with UC after AF ablation. A significant adherence-dependent difference of Complete was found in detecting AF recurrence.

5.
JACC Clin Electrophysiol ; 7(7): 843-854, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33640356

RESUMO

OBJECTIVES: This study sought to demonstrate a new type of verapamil-sensitive fascicular ventricular tachycardia (VT) with a reverse circuit. BACKGROUND: Left posterior fascicular ventricular tachycardia (LPFVT) is the most common form of verapamil-sensitive fascicular VT. Reverse-type LPFVT has not been reported. METHODS: We searched for a reverse-type LPFVT among 242 patients with verapamil-sensitive VT from February 2006 to September 2019. RESULTS: Three patients had a reverse-type LPFVT (cycle lengths: 340, 360, and 340 ms). QRS configuration during VT was narrow (140, 150, and 140 ms) and exhibited rSr' morphology in V1 with an early precordial transition and inferior axis. Two of 3 patients had common-type LPFVT. During reverse-type LPFVT, the earliest ventricular activation was the left superior middle septum. Fragmented Purkinje potentials (P1) buried within the local ventricular electrogram were recorded with an activation sequence from the apex to the base and were linked to the subsequent left ventricular septal activation. After radiofrequency catheter ablation at P1 during LPFVT, the reverse-type LPFVT also became noninducible. In 1 patient with only the reverse-type LPFVT, radiofrequency catheter ablation at the earliest LV activation site suppressed VT. These findings suggest that this new type of verapamil-sensitive fascicular VT shares a re-entrant circuit with a reverse direction of common LPFVT with an intramural exit site at the superior middle septum. CONCLUSIONS: Reverse-type LPFVT can occur. If common LPFVT exists, diastolic P1 during LPFVT can be a common target of ablation. If only reverse-LPFVT is inducible, the earliest ventricular activation site can be a target.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
6.
Radiol Case Rep ; 15(8): 1231-1234, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32577139

RESUMO

Incomplete filter opening, causing filter migration and inferior vena cava (IVC) perforation, have often been observed with the Greenfield-type IVC filter, but reports of incomplete opening of the ALN-type IVC filter are extremely rare. We present herein the case of incomplete opening of an ALN-type IVC filter due to entanglement of the filter legs, which caused filter migration, IVC wall perforation, and penetration into the kidney and iliopsoas muscle. Successful percutaneous retrieval was performed without complications. Our experience provides guidance for similar situations in the future, including the need to check for complete filter opening.

8.
Cardiovasc Interv Ther ; 33(2): 99-108, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27943219

RESUMO

This study aimed to evaluate the feasibility and utility of using motorized pullback of the pressure guidewire to provide a graphic assessment and prediction of the benefits of coronary intervention. Fractional flow reserve (FFR) measurements were performed with motorized pullback imaging in 20 patients who underwent successful percutaneous coronary intervention (PCI) of the left anterior descending artery. Physiological lesion length (PLL) was calculated using frame counts to determine stent length. FFR area was calculated by integrating the FFR values recorded during pullback tracing (FFRarea). The percentage increase in FFR area (%FFRarea) was defined as the ratio of the difference between the pre- and post-intervention FFRarea to the total frame count. The average FFR values were enhanced following PCI, from 0.64 to 0.82, and the median value of the difference between pre- and post-interventional FFR values (D-FFR) and %FFRarea were 0.13 and 10.6%, respectively. The %FFRarea demonstrated a significant positive correlation with D-FFR (R 2, 0.61; p < 0.01). PLL tended to be longer and the %FFRarea was smaller in lesions with a gradual pressure-drop pattern than those with an abrupt pressure-drop pattern (35.37 vs. 20.40 mm, p = 0.07; 5.78 vs. 16.21%, p < 0.05, respectively). Motorized pullback tracing was able to identify the extent and location of stenosis and help in appropriate stent implantation, in addition to visualizing and quantifying the improvement in FFR following PCI.


Assuntos
Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio
9.
PLoS One ; 12(6): e0180303, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28665970

RESUMO

BACKGROUND: The involvement of cholesterol crystals (CCs) in plaque progression and destabilization of atherosclerotic plaques has been recently recognized. This study aimed to evaluate the association between the intraplaque localization of CCs and plaque vulnerability. METHODS: We investigated 55 acute coronary syndrome (ACS) and 80 stable angina pectoris (stable AP) lesions using optical frequency domain imaging (OFDI) prior to percutaneous coronary intervention. The distance between CCs and the luminal surface of coronary plaques was defined as CC depth. RESULTS: Although the incidence of CCs had similar frequencies in the ACS and stable AP groups (95% vs. 89%, p = 0.25), CC depth was significantly less in patients with ACS than in those with stable AP (median [25th to 75th percentile]: 68 µm [58 to 92 µm] vs. 152 µm [115 to 218 µm]; p < 0.001). The incidences of plaque rupture, thrombus, lipid-rich plaques, and thin-cap fibroatheroma were significantly greater in patients with ACS than in those with stable AP (62% vs. 18%, p < 0.001; 67% vs. 16%, p < 0.001; 84% vs. 57%, p < 0.01; and 56% vs. 19%, p < 0.001, respectively). CONCLUSION: OFDI analysis revealed that CCs were found in the more superficial layers within the coronary atherosclerotic plaques in patients with ACS than in those with stable AP, suggesting that CC depth is associated with plaque vulnerability. CC depth, a novel OFDI-derived parameter, could be potentially used as an alternative means of evaluating plaque vulnerability in coronary arteries.


Assuntos
Colesterol/metabolismo , Vasos Coronários/patologia , Imagem Óptica/métodos , Placa Aterosclerótica/patologia , Idoso , Angina Estável/metabolismo , Angina Estável/patologia , Vasos Coronários/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/metabolismo
10.
Ann Nucl Med ; 30(10): 716-721, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27541874

RESUMO

BACKGROUND: Myocardial perfusion single-photon emission-computed tomography (SPECT) can predict cardiac events in patients with coronary artery disease with high accuracy; however, pseudo-negative cases sometimes occur. Heart Risk View, which is based on the prospective cohort study (J-ACCESS), is a software for evaluating cardiac event probability. OBJECTIVES: We examined whether Heart Risk View was useful to evaluate the cardiac risk in patients with normal myocardial perfusion SPECT (MPS). METHODS AND RESULTS: We studied 3461 consecutive patients who underwent MPS to detect myocardial ischemia and those who had normal MPS were enrolled in this study (n = 698). We calculated cardiac event probability by Heart Risk View and followed-up for 3.8 ± 2.4 years. The cardiac events were defined as cardiac death, non-fatal myocardial infarction, and heart failure requiring hospitalization. During the follow-up period, 21 patients (3.0 %) had cardiac events. The event probability calculated by Heart Risk View was higher in the event group (5.5 ± 2.6 vs. 2.9 ± 2.6 %, p < 0.001). According to the receiver-operating characteristics curve, the cut-off point of the event probability for predicting cardiac events was 3.4 % (sensitivity 0.76, specificity 0.72, and AUC 0.85). Kaplan-Meier curves revealed that a higher event rate was observed in the high-event probability group by the log-rank test (p < 0.001). CONCLUSION: Although myocardial perfusion SPECT is useful for the prediction of cardiac events, risk estimation by Heart Risk View adds more prognostic information, especially in patients with normal MPS.


Assuntos
Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Medição de Risco/métodos , Software , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Feminino , Humanos , Masculino , Isquemia Miocárdica/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA