Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Pediatr Cardiol ; 40(5): 921-924, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30937502

RESUMO

Ambulatory electrocardiogram monitoring devices can be used for 24-72 h to detect arrhythmias. A new device, the ZIO® XT Patch has cardiac monitoring capabilities that can be utilized for up to 14 days. The purpose of this study is to describe duration of ZIO use by age, and to compare its time to arrhythmia detection with the Holter monitor in a pediatric population. A single-center, retrospective review of patients < 18 years of age who underwent clinical investigation with ZIO from October 2014 to February 2016 was performed. An age-matched cohort was utilized to compare ZIO to Holter monitor results. Demographic and diagnostic data, time to first arrhythmia, and arrhythmia burden were analyzed. A total of 406 ZIO were prescribed; median age 12.7 years and 50% male subjects. Median duration of ZIO monitoring significantly increased with age (p < 0.001). 499 Holter monitors were prescribed on a statistically different age group. Arrhythmia detection rates were similar between groups, 10% (n = 42) by ZIO and 9% (n = 45) by Holter (p = NS). The majority of arrhythmias (57%) detected by ZIO were after 24 h (p < 0.0001). All arrhythmias detected by Holter monitor occurred within 24 h (p < 0.0001), mean duration of wear was 24.1 h, range 0.5-48 h. The ZIO® XT Patch may be considered as an ambulatory ECG monitor to diagnose arrhythmia in pediatric patients of all ages. Increasing patient age resulted in increasing duration of ZIO monitoring. Majority of arrhythmias detected with ZIO were identified after 24 h, which would have been missed by other short-term monitors.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial/métodos , Adolescente , Criança , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo
3.
J Innov Card Rhythm Manag ; 9(9): 3315-3316, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32477823

RESUMO

We present the first known report of a pediatric implantation of the Bluetooth™-enabled Confirm RX™ insertable cardiac monitor (Abbott Laboratories, Chicago, IL, USA) in a 17-year-old patient with unexplained syncopal episodes. This case illustrates the ability to obtain immediate rhythm information from a patient using a Bluetooth™-enabled device following a minimally invasive procedure.

4.
Circ Cardiovasc Imaging ; 11(3): e006708, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29555832

RESUMO

BACKGROUND: Aortic stenosis has been reported to manifest a slow rate of progression in mild disease, with a greater likelihood of progression in patients with moderate-severe disease. The natural history of the Doppler-estimated maximum gradient (DEMG) in patients after balloon aortic valvuloplasty (BAVP) has not previously been studied on a large scale. METHODS AND RESULTS: A retrospective review was performed of 360 patients from 1984 to 2012 with aortic stenosis, providing a total of 2059 echocardiograms both before and after BAVP. Patients were excluded if they had an intervention within the first 30 days of life. The relationships between the aortic stenosis DEMG and several predictors (age at initial study, body surface area, valve morphology, and initial DEMG) were explored using linear mixed effect models. Patients with a unicommissural aortic valve had a significantly higher rate of progression compared with those with a bicommissural aortic valve (0.81 and 0.45 mm Hg/year; P<0.001). The median rate of progression in the post-BAVP group was significantly lower than the median pre-BAVP rate of progression (n=34; pre-BAVP 3.97 [1.69-8.7] mm Hg/year; post-BAVP 0.40 [-1.80 to 3.88] mm Hg/year; P<0.008). When adjusted for body surface area, there was no significant increase in the DEMG (-0.03 mm Hg/m2 per year; P<0.001). CONCLUSIONS: There is a statistically significant increase in the DEMG over time in patients with aortic stenosis. After balloon dilation, the DEMG rate of change is reduced compared with that pre-dilation. Given the effect of body surface area on DEMG progression, more frequent observation should be made during periods of rapid somatic growth.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valvuloplastia com Balão/métodos , Ecocardiografia Doppler/métodos , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Adolescente , Adulto , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/diagnóstico , Criança , Pré-Escolar , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Período Pós-Operatório , Período Pré-Operatório , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
5.
Congenit Heart Dis ; 12(4): 411-416, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28240408

RESUMO

OBJECTIVE: Pseudosyncope can be difficult to distinguish from true syncope. Often, pediatric patients with pseudosyncope undergo multiple tests and referrals before the appropriate diagnosis is reached. The purpose is to describe the utility of the head-up tilt table test to elicit the diagnosis of pseudosyncope in the pediatric population. DESIGN: Retrospective chart review from November 2012 to December 2015 of patients age ≤23 years referred for 30-minute, 80-degree tilt table test. Pretest probability for pseudosyncope was high if there was no response to traditional management, atypical episodes, occurrence during undesirable exercise, or prolonged episode duration. Inductive techniques were utilized to persuade patients of the likelihood of experiencing an episode during the procedure. Pseudosyncope was confirmed when a patient had normal vital signs during their event and had reflex responses to disruptive maneuvers. RESULTS: Tilt table testing was performed on 89 patients [median age 16 years (5-23); 26% male] with the majority (60%) being negative for pseudosyncope, including 51 true negatives and 2 false-negatives. Of the 36 patients with syncope during tilt table testing, 28 were diagnosed with vasovagal syncope and 8 with pseudosyncope [median age 16 years (15-21); 38% male]. Pseudosyncope episodes were observed immediately in 2 patients. All patients with late-onset pseudosyncope required inductive techniques prior to the recorded episode. CONCLUSIONS: Pseudosyncope can be identified during tilt table testing if inductive techniques are utilized in patients with a high index of suspicion. Disruptive maneuvers are excellent adjunctive methods to confirm the diagnosis. Tilt table testing is an effective means to identify pseudosyncope and allow appropriate diagnosis and treatment.


Assuntos
Avaliação de Sintomas/métodos , Síncope Vasovagal/diagnóstico , Teste da Mesa Inclinada/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Diagnóstico Diferencial , Eletrocardiografia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
6.
J Innov Card Rhythm Manag ; 8(1): 2584-2588, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32477753

RESUMO

Implantable loop recorders are commonly used to sense arrhythmias. The purpose of this study is to assess the P- and R-wave amplitudes at implantation (I) and follow-up (F) following insertion of the Reveal LINQ™ Insertable Cardiac Monitor (Medtronic, Minneapolis, MN) in an institutional review board-approved, multicenter study performed on pediatric patients younger than 18 years old. Collected data included demographics, presence of congenital heart disease (CHD), P- and R-wave-sensed amplitude at I and F, and the method of implant (i.e. mapping or standard.) P waves were manually measured and R-wave sensing was recorded by the device. A total of 87 patients had a Reveal LINQ™ (Medtronic, Minneapolis, MN) device implanted; the mean patient age was 11.8 years (0.5 years to 18 years) with 48% of patients being female and 19% of patients having CHD; mapping was used in 43% of patients. The Reveal LINQ™ (Medtronic, Minneapolis, MN) experienced no change in average sensed R-wave amplitude at either I or F (1.28 mV vs 1.26 mV, p = NS). There was no difference in sensed R-wave amplitude noted with or without mapping used at I (1.29 mV vs 1.26 mV, p = NS) or F (1.48 mV vs 1.18 mV, p = NS). Additionally, no difference could be found in R-wave sensing of patients with CHD or without CHD at I (1.26 mV vs 1.4 mV, p = NS) or F (1.32 mV vs 1.32 mV, p = NS). R-wave sensing trended towards being inversely proportional to patient body surface area (BSA) (p = NS). P waves were detected on 48% of tracings in all patients at I and/or F, irrespective of whether the Reveal LINQ™ (Medtronic, Minneapolis, MN) device was placed with mapping. The R wave was (0.37-3.5 mV) at I and (0.3-3 mV) (p = NS) at F when P waves were detected. From these results, it can be said that the Reveal LINQ™ Insertable Cardiac Monitor (Medtronic, Minneapolis, MN) has an excellent ability to sense R-wave amplitude in pediatric patients. No significant difference in the sensing ability of the device could be identified with respect to the presence of CHD, use of mapping or BSA. P waves tended to be identified when there was a higher baseline R-wave amplitude.

7.
Heart Rhythm ; 11(2): 182-6, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24513916

RESUMO

BACKGROUND: Ebstein's anomaly is associated with a high incidence of atrial and ventricular arrhythmias. The Cone procedure has become an effective hemodynamic intervention for this malformation. In response to two late postoperative sudden deaths in our early institutional Cone experience, a standardized plan for aggressive rhythm evaluation was instituted, including preoperative electrophysiologic studies (EPS) and intraoperative implantable loop recorder (ILR) placement. OBJECTIVE: The purpose of this study was to measure the yield of this diagnostic protocol for patients with Ebstein's anomaly undergoing surgical repair and to describe its influence on patient management. METHODS: All patients at Boston Children's Hospital with Ebstein's anomaly who underwent the Cone procedure from December 2006 to September 2012 were reviewed. Pre- and postoperative arrhythmias and therapies were documented. For patients who underwent preoperative EPS, all arrhythmia substrates and interventions were recorded. RESULTS: A total of 74 patients were included, 42 of whom underwent preoperative EPS. Significant findings were documented during EPS in 29 of the 42 patients (69%), including eight patients with no prior suspicion of arrhythmias. Seventeen patients had successful catheter ablation during EPS, and EPS data guided one or more intraoperative rhythm interventions for the remainder. During follow-up, diagnostic yield from ILR was low. Since implementing a more aggressive diagnostic strategy, no further sudden deaths have occurred. CONCLUSION: Preoperative EPS has a high diagnostic and therapeutic yield in patients with Ebstein's anomaly undergoing the Cone operation. It is reasonable to recommend EPS as a routine preoperative test for this population.


Assuntos
Arritmias Cardíacas/diagnóstico , Anomalia de Ebstein/fisiopatologia , Anomalia de Ebstein/cirurgia , Eletrocardiografia , Adolescente , Adulto , Arritmias Cardíacas/cirurgia , Ablação por Cateter , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA