RESUMO
This study evaluated the feasibility of an automated method to delimit the required area to quantitatively analyze root filling voids and gaps from cross-sectional confocal laser scanning microscopy (CLSM) images. Root canals of maxillary canines were prepared with rotary instruments and filled by lateral compaction technique using gutta-percha and AH Plus sealer. The roots were stored (100% humidity, 37 °C) for a period of 24 h and then transversally sectioned to obtain 2-mm-thick slices from the apical and middle thirds. The areas corresponding to filling materials, gaps, and voids were manually delimited or automatically demarked by ImageJ software after converting the images to the RGB color system. Based on manual and automatic delimitations, the percentages of voids and gaps were calculated. Data of voids and gaps between middle and apical thirds were individually compared by paired t-test. Pearson`s correlation test was used to assess the correlation of data between the methods. Irrespective of the method of area delimitation, no difference was observed between the root thirds for both voids and gaps, while the p-values calculated for each method were similar. Almost perfect correlations between the methods were observed for both outcomes. The proposed method to automatically delimit the areas corresponding to filling material, voids, and gaps appears to be a valid method to facilitate the quantitative analysis of defects in root canal fillings using topographic CSLM images.
Assuntos
Materiais Restauradores do Canal Radicular , Resinas Epóxi , Estudos Transversais , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Teste de Materiais , Guta-Percha , Obturação do Canal Radicular/métodosRESUMO
To evaluate the impact on the quality of filling with of low-fusion and conventional gutta-percha cones. Thirty-six maxillary canines were prepared and divided into three groups: I-conventional cone with Downpack at 200 °C at 4 mm from the WL; II-low-fusion cone with Downpack at 100 °C up to 4 mm from the WL; III-low-fusion cone with Downpack at 100 °C up to 7 mm from the WL. Temperature variations were measured in thirds on the external surface of the root. The bond strength was evaluated using the push-out test. The adhesive interface was analyzed by scanning electron microscopy. The bond strength and the temperature variation data were analyzed using analysis of variance and the failure type using the chi-square test. The low-fusion cone group with 7 mm Downpack showed higher bond strength (4.2 ± 2.7) compared with conventional cones (2.8 ± 1.6) and low-fusion cones with 4 mm Downpack (2.9 ± 1.6) (p < 0.05), with occurrence of a higher number of adhesive failures to the filling material and mixed failures. Relative to temperature variation, there was less temperature change in the apical third, in the low-fusion cone with Downpack 7 mm (1.0 ± 1.0) (p < 0.05). The use of low-fusion cones allowed the continuous wave condensation technique to be performed at a lower depth of Downpack at 100 °C at 7 mm, with less heating in the apical third, without compromising the quality of filling. Using gutta-percha cones with low fusion, which permits a lower condensation temperature and reduced Downpack depth, maintains the quality of filling, in order to minimize possible damage to the periapical tissues.
Assuntos
Colagem Dentária , Guta-Percha , Teste de Materiais , Microscopia Eletrônica de Varredura , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Guta-Percha/química , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Humanos , Colagem Dentária/métodos , Técnicas In Vitro , Cerâmica/química , Propriedades de Superfície , Dente Canino , Análise do Estresse Dentário , TemperaturaRESUMO
STATEMENT OF PROBLEM: The biomechanical stability of the implant-prosthesis assembly and its maintenance under function is a determining factor in the success of implant prosthesis rehabilitation, but studies of different angular tapers are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the axial displacement and torque loss of prosthetic abutments with Morse-type connections of different angular tapers after thermomechanical cycling by using microcomputed tomography (µCT) and a digital torque wrench. MATERIAL AND METHODS: Eighteen Ø3.5×11.5-mm implants were embedded in polyvinyl chloride cylinders, and the 3 different types of abutments (n=6) with angular tapers of 11.5 degrees - Alvim Cone Morse (ACM-11.5), 16.0 degrees - Helix Gran Morse (HGM-16), and 24.0 degrees - Nobel Replace Conical Connection (NRC-24) were installed with the torque recommended by the manufacturers. To calculate the axial displacements of the abutments about the implants, zirconia maxillary canine crowns were fabricated using a computer-aided design and computer-aided manufacturing (CAD-CAM) system and cemented onto the abutments. Before and after thermomechanical cycling, the assemblies were scanned using microtomography (micro-CT) to assess axial displacement, and the torque losses were calculated after the abutments were finally unscrewed. A load of 100 N, frequency of 2 Hz, and 106 cycles with temperature variation of 5 °C to 55 °C were used for the thermomechanical cycling. Analysis of variance and the Tukey post hoc test (α=.05) were used for analysis. RESULTS: A significant difference was observed between the abutments for axial displacement, measured after thermomechanical cycling (P=.002). The ACM-11.5 abutment showed the highest mean value (134.1 ±58.7 µm), different from HGM-16 (63.3 ±26.1 µm) (P=.013) and NRC-24 (42.7 ±8.7 µm) (P=.002); the 2 latter groups were similar to each other (P=.618). For the torque losses, no significant difference was found among the abutments (P=.928), but there were significant differences for the thermomechanical cycling (before and after) (P<.001) in that the loss of torque was greater after thermocycling. CONCLUSIONS: The smaller the taper angle of the Morse-type prosthetic abutment, the greater its axial displacement, and the thermomechanical cycling significantly reduced pretorque, regardless of taper.
RESUMO
AIM: To evaluate the shaping ability of several heat-treated nickel-titanium systems used to prepare root canals with moderate and severe curvature, in extracted mandibular molars, by micro-computed tomography, considering their variation in kinematics and design. METHODOLOGY: Curved-mesial roots of mandibular molars were randomly selected and assigned into 4 balanced experimental groups (n = 10), established by determining homogeneous 3D parameters of volume and surface area: R-Motion (RM) size 30, 0.04 taper (RM; FKG Dentaire), Reciproc Blue (RCB) size 25, 0.08 taper (RCB; VDW GmbH), HyFlex CM (HFX) size 30, 0.04 taper (HFX; Coltène Whaledent) and XP-endo Shaper size (XPS) 30, 0.01 taper (XPS; FKG Dentaire). The volume of irrigation was established at 10 ml of 2.5% NaOCl. Throughout the entire root canal preparation procedures, the samples were fixed in a vice submerged in a container with water monitored at 37°C. Dimensional cross-sectional measures of area, perimeter, roundness, major/minor diameters and 3-dimensional (volume, surface area, structure model index - SMI) parameters as well as the smallest dentine thickness along the cervical and middle root thirds were evaluated by micro-CT. Data were analysed using analysis of variance and post hoc Tukey tests (α = 5%). RESULTS: Reciproc Blue and XPS had significantly greater mean increases in cross-sectional area measurements, only in the middle third, when compared with RM and HFX (p < .05). RM, RCB and XPS had a similar increase in measurements of length and width of perimeter (p > .05), and HFX had significantly lower mean increases in perimeter values only when compared with XPS (p < .05). RCB and XPS had significantly greater mean increases in volume when compared with RM and HFX (p < .05). RM had a significantly lower difference in SMI after preparation, compared with RCB, HFX and XPS (p < .05). The smallest dentine thickness was observed after the use of RCB (p < .05), in the danger and safety zones. CONCLUSIONS: XP-endo Shaper and RM had a shaping ability similar to that of instruments with larger tapers, achieved with less dentine removal in danger and safe zones in curved-mesial canals of extracted molar teeth treated on a laboratory benchtop.
Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Níquel , Titânio , Microtomografia por Raio-XRESUMO
This study evaluated the influence of photobiomodulation (PBM) using low-level laser therapy (PBM/LLLT) or light-emitting diode (PBM/LED) therapy on peri-implant tissue healing. A laboratory model was used to assess the adhesion and metabolism of osteoblasts (SaOs-2), human gingival fibroblasts (HGF), and normal oral keratinocytes (NOK) seeded on a titanium (Ti) surface. After seeding the cells on disks of Ti placed in wells of 24-well plates, three irradiations were performed every 24 h at energy density of 3 J/cm2. For PBM/LLLT, a LaserTABLE device was used with a wavelength of 780 nm and 25 mW, while for PBM/LED irradiation, a LEDTABLE device was used at 810 nm, 20 mW, at a density of 3 J/cm2. After irradiations, the number of cells (NC) attached and spread on the Ti surface, cell viability (CV), total protein (TP), and collagen (Col) synthesis were assessed. Alkaline phosphate activity (ALP) was evaluated only for SaOs-2. Data were submitted to ANOVA complemented by Turkey statistical tests at a 5% significance level. PBM significantly increased adherence of NOK to the Ti surface, while no significant effect was observed for SaOs-2 and HGF. PBM positively affected CV, as well as Col and TP synthesis, in distinct patterns according to the cell line. Increased ALP activity was observed only in those cells exposed to PBM/LLLT. Considering cell specificity, this investigation reports that photobiomodulation with low-power laser and LED at determined parameters enhances cellular functions related to peri-implant tissue healing in a laboratory model.
Assuntos
Terapia com Luz de Baixa Intensidade , Proliferação de Células , Gengiva , Humanos , Osseointegração , OsteoblastosRESUMO
OBJECTIVE: The aim of this study was to evaluate the efficacy of supplementary techniques (ultrasonic tip/XP-endo Finisher R) in removing remaining filling materials (gutta-percha/AHPlus/BCSealer) from oval-shaped root canals during non-surgical endodontic retreatment. MATERIAL AND METHODS: Twenty-eight distal roots of human mandibular molars with single and oval-shaped canals were initially shaped with a R40 instrument and filled with gutta-percha points and AH Plus (n = 14) or BC Sealer (n = 14) followed by an initial micro-CT scanning. Initial filling material removal was performed in all 28 samples with an R50 instrument, and all samples submitted to a second micro-CT. Supplementary techniques with ultrasonic tips or XP-endo Finisher R instruments were performed in each sealer group, and all samples submitted to a third micro-CT. The volume of remaining filling material was calculated for the entire canal as well as for the coronal, middle, and apical thirds. Statistical analyses were performed using T, ANOVA 3-way, and Tukey tests. RESULTS: Lower values of remnant filling material were found for BC Sealer (16.06 ± 14.34) compared to AH Plus (28.30 ± 10.54) (P < 0.001), and considering the supplementary technique, lower values of remnant filling material were found for the ultrasonic tip (18.95 ± 11.05) compared to XP-endo Finisher R (25.41 ± 15.81) (P = 0.025). Ultrasonic instruments significantly reduced the percentage of remaining filling material for both AH Plus (P = 0.04) and BC Sealer (P = 0.02) while XP-endo Finisher R was effective for AHPlus only (P = 0.04). The remaining filling material was observed in all samples regardless the filling material or the supplementary technique employed. CONCLUSIONS: Supplementary techniques increased filling material removal; however, none of them was able to render root canals completely free from root fillings. Ultrasonic tips should be considered a good option for endodontic retreatment, especially for bioceramic cases. CLINICAL RELEVANCE: Supplementary instrumentation techniques are effective tools to reduce the amount of filling materials during root canal retreatment.
Assuntos
Cavidade Pulpar , Materiais Restauradores do Canal Radicular , Resinas Epóxi , Guta-Percha , Humanos , Retratamento , Obturação do Canal Radicular , Preparo de Canal RadicularRESUMO
OBJECTIVES: This study aimed to evaluate the effects of different shaping protocols on the root canal geometry and remaining dentin thickness of mandibular premolars with radicular grooves (RG) and two canals by means of micro-CT. MATERIALS AND METHODS: Mandibular premolars with RG and two canals were matched based on their similar morphological dimensions and assigned to 2 experimental groups according to the canal preparation (n=8): XP-endo Shaper (XPS) and ProTaper Next (PTN) systems. Before and after preparation, morphometric measurements of the volume, surface area, structure model index, area, perimeter, roundness, major and minor diameters, as well as untouched canal walls, canal transportation, and dentin wall thickness were evaluated. Data were statistically compared within and between groups using the independent sample t test (α=5%). RESULTS: XPS revealed less changes in volume, surface area, area, perimeter, and major and minor diameters (P<0.05). There was no significant difference in structure model index (SMI), roundness, and percentage of untouched canal walls between groups (P>0.05). XPS resulted in less apical canal transportation and a higher remaining dentin thickness toward the RG compared to PTN in lingual canals (P<0.05). CONCLUSIONS: XPS revealed fewer changes in root canal geometry as well as lower transportation and a greater remaining dentin thickness in the lingual canals toward the RG compared to PTN. CLINICAL RELEVANCE: Internal and external anatomical characteristics of mandibular premolars might have an influence on biomechanical preparation. Considering the risk of perforation, the canal preparation using XPS appears to be more conservative compared to PTN.
Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Dente Pré-Molar/diagnóstico por imagem , Cavidade Pulpar/diagnóstico por imagem , Dentina/diagnóstico por imagem , Desenho de Equipamento , Humanos , Microtomografia por Raio-XRESUMO
STATEMENT OF PROBLEM: An intraradicular retainer formed by multiple independent glass fiber filaments was developed aiming to allow better adaptation in flattened root canals; however, the performance of the new posts is unclear. PURPOSE: The purpose of this in vitro study was to compare the bond strength (BS) and adhesive interface quality achieved in flattened root canals restored with conventional glass fiber posts (CFPs) and multifilament glass fiber posts (MFPs). MATERIAL AND METHODS: The distal roots of mandibular molars with long oval root canals were endodontically treated, and the obturation material was removed and assigned to 2 groups (n=11) according to the type of retainer used: CFP (WhitePostDC#0.5; FGM) or MFP (CometTail#4; Synca). The posts were cemented with self-adhesive resin cement. The specimens were sectioned (2 slices per third). The most cervical slice in each third was used to evaluate the BS, while the adhesive interface in the apical slices was analyzed by scanning electron microscopy. BS data were analyzed by using a multilevel generalized linear model, and adhesive interface SEM data were analyzed by using a multilevel ordinal logistic regression model (α=.05). RESULTS: Multilevel regression showed a statistically significant difference for the "type of retainer" factor (P=.001; CFP 2.61 ±1.30>MFP 1.59 ±1.54). No statistically significant differences were found for the "root thirds" factor (P=.346) or for the interaction of both factors (P=.114). The failure pattern was predominantly mixed or adhesive for CFP and adhesive to dentin for MFP. A better adaptation of the restorative material was observed in the cervical third for CFP and in the apical third for MFP (P<.001). CONCLUSIONS: MFP resulted in lower BS values than CFP, with a higher prevalence of adhesive failures to dentin and better adaptation of the adhesive interface in the apical third.
Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cavidade Pulpar , Análise do Estresse Dentário , Dentina , Vidro , Teste de Materiais , Cimentos de ResinaRESUMO
AIM: The objective of this study was to assess apical extrusion after filling material removal using two systems, one rotary and one reciprocating. MATERIALS AND METHODS: A total of 34 extracted mandibular premolars with single roots were selected and, posteriorly, prepared and filled. Following material aging for 60 days, teeth were divided into two groups, according to the method used to remove root filling material: group I, ProTaper® Universal Retreatment instruments plus refining with the Hero 642® sequence and group II, WaveOne® instruments. The teeth were fixed in an apparatus designed to collect the extruded material during removal procedure. Data on the amount of debris extruded (mg/weight) were analyzed using the Student's t test with a significance level of 5%. RESULTS: No significant differences were found between the groups with regard to the amount of material extruded during root canal retreatment. CONCLUSION: The present findings suggest that the extrusion of debris during apical root canal retreatment does not depend on the instrument design or the protocol employed. CLINICAL SIGNIFICANCE: Regardless of root canal clearance techniques, debris extrusion eventually occurs during endodontic retreatment and may be related to postoperative pain.
Assuntos
Materiais Restauradores do Canal Radicular , Preparo de Canal Radicular , Cavidade Pulpar , Humanos , Retratamento , Tratamento do Canal RadicularRESUMO
OBJECTIVE: The aim was to evaluate the influence of Er,Cr:YSGG laser irradiation associated with different final irrigation protocols on the bond strength of epoxy resin-based root canal sealer to root dentin, on the dentin/filling material interface and in the temperature variation during irradiation. METHODOLOGY: Ninety-six maxillary canines were prepared with K3 rotary system up to #45/0.02 instrument, irrigating with distilled water between files. The specimens were randomly assigned to three groups-final irrigation (distilled water, 1% NaOCl, and 17% EDTAC) and four subgroups (n = 8)-laser parameters (non-irradiated, 2 W/20 Hz, 3 W/20 Hz, and 4 W/20 Hz). During irradiation, the temperatures were measured on the outer root dentin wall in the three thirds, and root apex. Canals were filled with lateral condensation of AHPlus sealer and gutta-percha cones. Two slices from each third were submitted to a push-out test in Instron machine and the failure mode was analyzed. One slice from each third was analyzed by confocal laser microscopy to evaluate the percentage of the perimeter of the root canal cross-section with sealer tags and depth of tags. Data were analyzed by ANOVA, Kruskal-Wallis, and Tukey's tests (P < 0.05). RESULTS: Er,Cr:YSGG laser irradiation increased sealer bond strength to dentin, regardless of the final irrigation. The highest values were obtained for 3 W (4.02 ± 1.32) and 4 W (4.18 ± 0.98) powers and different from the non-irradiated group (2.64 ± 0.58) (P < 0.05). The 2 W irradiation produced similar results to 3 W and 4 W when associated with 17% EDTA. Final irrigation with 17% EDTAC provided higher bond strength (4.01 ± 1.02) compared with distilled water (3.11 ± 1.09) and 1% NaOCl (3.47 ± 1.18) (P < 0.05). The cervical third (4.01 ± 1.21) presented significantly higher bond strength than the apical third (3.04 ± 0.89). There was a greater percentage of adhesive and mixed failure. In the groups irradiated with 3 W [21.1 (14.1-27.7)] and 4 W [17.8 (11.9-23.7)], a greater depth of filling material tags was observed compared with the non-irradiated group [12.9 (9.0-20.0)]. The greatest percentage of canal perimeter with sealer tags was observed in the irradiated groups, with no difference among them (P > 0.05). The temperature rise was proportional to the increase of laser power. CONCLUSIONS: Er,Cr:YSGG laser irradiation increased the bond strength of an epoxy resin-based sealer to root dentin, with greater formation of sealer tags for all tested powers, especially when combined with 17% EDTAC final irrigation; temperature rise during irradiation remained below the critical threshold biologically accepted. Lasers Surg. Med. 48:985-994, 2016. © 2016 Wiley Periodicals, Inc.
Assuntos
Colagem Dentária/métodos , Dentina/efeitos da radiação , Resinas Epóxi/química , Lasers de Estado Sólido , Materiais Restauradores do Canal Radicular/química , Dentina/química , Dentina/diagnóstico por imagem , Humanos , Técnicas In Vitro , Microscopia Confocal , Distribuição Aleatória , Temperatura , Suporte de CargaRESUMO
Endodontic retreatment is often necessitated by several factors, including the persistence of microorganisms in the root canal system (RCS). Their complex organization in biofilms increases their pathogenic potential, necessitating new disinfection strategies. This study aimed to standardize a new in vitro protocol for collecting biofilm from the RCS. Thirty-four bovine incisors were used in the study, divided into two experimental groups with two collection steps each: (a) biofilm collection protocol and (b) absorbent paper points protocol. Twelve specimens from each group were selected for counting colony-forming units (CFUs), while eight specimens were prepared for scanning electron microscopy (SEM). Two additional specimens served as sterilization controls to ensure that experiments were free of contamination. The coronal region was removed and standardized at 15 mm. After preparation with ProTaper up to F5, the apical foramen was sealed with composite resin, and the roots were stabilized with acrylic resin in 1.5-mL Eppendorf tubes. The specimens were sterilized and inoculated with Enterococcus faecalis NTCT 775 every 24 h for 21 days. After this period, each group underwent biofilm collection protocols, and CFU and scanning electron microscopy (SEM) data were analyzed. The Shapiro-Wilk test was performed to assess the normality of log-transformed data, and the results indicated a normal distribution for all groups, allowing parametric testing. The Levene test was used to evaluate the equality of variances. The proposed biofilm collection method yielded significantly higher CFU counts compared with the absorbent paper points method, particularly when analyzed on a log10 scale. An independent samples t-test confirmed a statistically significant difference between the two methods (p < 0.0001). The proposed protocol achieved an efficiency rate of 95.85 % ± 1.15 %, whereas the absorbent paper points protocol yielded a lower efficiency of 5.46 % ± 1.37 %. Therefore, the biofilm collection protocol proposed in this study proved to be more effective for biofilm removal from the RCS.
Assuntos
Biofilmes , Cavidade Pulpar , Enterococcus faecalis , Microscopia Eletrônica de Varredura , Biofilmes/crescimento & desenvolvimento , Animais , Bovinos , Cavidade Pulpar/microbiologia , Enterococcus faecalis/fisiologia , Enterococcus faecalis/crescimento & desenvolvimento , Microscopia Eletrônica de Varredura/métodos , Contagem de Colônia Microbiana , Incisivo/microbiologia , Manejo de Espécimes/métodosRESUMO
This study aimed to identify and characterize the antimicrobial susceptibility profile of bacteria found in primary endodontic infections in the teeth of patients treated at the Dental Clinic of the University of Ribeirão Preto, São Paulo, Brazil. From September to December 2019, samples were obtained from 21 patients with primary endodontic infections. The collections were carried out in triplicate using paper cones placed close to the total length of the root canal. Bacterial isolation was performed in Brain Heart Infusion agar, Blood agar, and other selective culture media cultured at 37°C for up to 48 h under aerobiosis and microaerophilic conditions. The bacterial species were identified using the Vitek 2 automated system. The disk diffusion method on agar Müeller-Hinton was used to assess antimicrobial susceptibility with the recommended antimicrobials for each identified bacterial species. A total of 49 antibiotics were evaluated. Fifteen of the 21 samples collected showed bacterial growth, and 17 bacterial isolates were found. There were 10 different bacterial species identified: Enterococcus faecalis (four isolates), Streptococcus mitis/oralis (three isolates), Streptococcus anginosus (three isolates) being the most common, followed by Staphylococcus epidermidis, Enterococcus faecium, Streptococcus constellatus, Streptococcus alactolyticus, Enterobacter cloacae, Klebsiella variicola, and Providencia rettgeri (one isolate of each species). The analysis demonstrated significant susceptibility to most of the tested antibiotics. However, some Enterococcus isolates resisted the antibiotic's erythromycin, ciprofloxacin, and tetracycline. A Staphylococcus epidermidis isolate was characterized as multidrug-resistant. Five Streptococcus isolates were non-susceptible to all antibiotics tested.
Assuntos
Anti-Infecciosos , Enterococcus faecium , Humanos , Ágar , Testes de Sensibilidade Microbiana , Brasil , Antibacterianos/farmacologia , Meios de CulturaRESUMO
The aim of this study was to evaluate the effects of supplementing toothpastes containing 1100 ppm F with micrometric or nanometric [beta]-calcium glycerophosphate (ß-CaGPm/ß-CaGPn) on artificial enamel demineralization, using a pH cycling model. Bovine enamel blocks (4 mm × 4 mm, n = 120) selected using initial surface hardness were randomly allocated to ten toothpaste groups (n = 12): without fluoride or ß-CaGPm or ß-CaGPn (Negative control), 1100 ppm F (1100 F), and 1100 ppm F plus 0.125%, 0.25%, 0.5%, and 1.0% of ß-CaGPm or ß-CaGPn. Blocks were treated two times per day with toothpaste slurry and subjected to five pH cycles (demineralizing and remineralizing solutions) at 37 °C. The final surface hardness, percentage of surface hardness loss (%SH), cross-sectional hardness (ΔKHN), and profile analysis and lesion depth subsurface were analysed using polarized light microscopy (PLM). Fluoride (F), calcium (Ca), and phosphorus (P) concentrations were also measured. Data were analysed using ANOVA and Student-Newman-Keuls tests ([alpha] = 0.001). Blocks treated with 1100 F toothpaste containing 0.5%ß-CaGPm or 0.25%ß-CaGPn showed with reduced %SH values when compared with those treated with 1100 F alone (p < 0.001). Reduced lesion depths (ΔKHN and PLM) were observed for the slurry made up of 1100 F and 0.25%ß-CaGPn (p < 0.001). The addition of ß-CaGPm and ß-CaGPn did not influence the enamel F concentration, with the 1100 F/0.25%ß-CaGPn group exhibiting the highest Ca and P enamel concentrations (p < 0.001). Based on the findings of this in vitro study, we can conclude that the fluoride toothpaste produced a superior effect when combined at an appropriate ß-CaGP molar ratio. This effect was achieved with a lower proportion of ß-CaGP in the form of nanometric particles.
Assuntos
Fluoretos , Desmineralização do Dente , Humanos , Animais , Bovinos , Fluoretos/farmacologia , Fluoretos/análise , Cremes Dentais/farmacologia , Cálcio , Glicerofosfatos , Estudos Transversais , Desmineralização do Dente/prevenção & controle , Dureza , Suplementos Nutricionais , Concentração de Íons de HidrogênioRESUMO
AIM: To mensure the physicochemical properties of three ceramic cement endodontic sealers AH Plus Bioceramic, Bio-C Sealer and Bio-C Sealer Ion+ with an epoxy resin sealer, AH Plus. MATERIAL AND METHODS: These properties were measured: hardening time (HT), dimensional change (DC), solubility (SL), flow (FL) and radiopacity (RD). The distilled water obtained from the SL test was analyzed with atomic absorption spectrometry. A sample calculation was made considering n = 5 repetitions for each experimental sealer evaluated. Statistical analysis was performed using one-way ANOVA and post hoc Tukey tests (p < 0.05). RESULTS: For the HT, AH Plus (484 ± 2.76 min) and AH Plus Bioceramic (424 ± 1.23 min) set more slowly than of Bio-C Sealer (370 ± 4.50 min) and Bio-C Sealer Ion+ (380 ± 1.42 min) (p < 0.05). AH Plus Bioceramic (12.56 ± 2.71 %) was more soluble than Bio-C Sealer (6.69 ± 1.67 %), Bio-C Sealer Ion+ (5.67 ± 2.16 %) and AH Plus (0.15 ± 0.01 %) (p < 0.05). AH Plus (0.03 ± 0.01 %) had slight expansion while the cement-based sealers had shrinkage: AH Plus Bioceramic (-1.60 ± 0.63 %) and Bio-C Sealer (-1.38 ± 0.69 %), Bio-C Sealer Ion+ (-5.19 ± 1.23 %) (p < 0.05). Bio-C Sealer Ion+ (59.80 ± 0.86 mm) and Bio-C Sealer (58.60 ± 0.98 mm) had the highest flow compared with AH Plus (56.90 ± 0.56 mm) and AH Plus Bioceramic (49.50 ± 0.63 mm) (p < 0.05). AH Plus (9.17 ± 0.06 mmAl) and AH Plus Bioceramic (8.27 ± 0.84 mmAl) showed radiopacity values when compared with those of Bio-C Sealer (4.90 ± 0.08 mmAl) and Bio-C Sealer Ion+ (4.14 ± 0.05 mmAl) (p > 0.05). CONCLUSION: Ion release is inhered to these cement-based sealers and this result in calcium ion release.
Assuntos
Cálcio , Materiais Restauradores do Canal Radicular , Cálcio/química , Materiais Restauradores do Canal Radicular/química , Compostos de Cálcio/química , Resinas Epóxi/química , Silicatos/química , Teste de MateriaisRESUMO
Few reports have addressed the effects of diode laser irradiation at 980 nm on the morphology and fracture resistance of dentine. The purpose of this study is to evaluate the effects of 980-nm diode laser on the ultrastructure and fracture resistance of root dentine. The roots of 90 extracted canine teeth were divided into three groups according to the type of irrigating solution (water, NaOCl, and NaOCl/EDTA) and subdivided into three subgroups (n = 10) according to the amount of laser irradiation (without irradiation, 1.5 W/100 Hz and 3.0 W/100 Hz). The roots were filled with an epoxy resin-based sealer and gutta-percha and then subjected to a fracture resistance test. Data were analyzed by ANOVA and the Tukey test (p < 0.05). Additionally, 18 canine teeth were prepared using the same irrigation/irradiation protocols and evaluated by scanning electron microscopy (SEM). The SEM showed greater changes when the laser power increased, and the changes also varied according to the irrigating solution. A modified smear layer was observed in specimens that were treated with water and then laser-irradiated. The laser treatment did not alter the fracture resistance of roots treated with 1.5 W/100 Hz (246.3 ± 29.5 N) and 3.0 W/100 Hz (215.3 ± 25.1 N) laser power. The roots treated with NaOCl were more susceptible to fracture (199.4 ± 15.1 N) than those irrigated with water (254.2 ± 23.0 N) (p < 0.05). The 980-nm diode laser altered the morphology of the dentine but did not affect the fracture resistance of the roots.
Assuntos
Dentina/efeitos da radiação , Dentina/ultraestrutura , Lasers Semicondutores , Preparo de Canal Radicular/métodos , Fraturas dos Dentes/fisiopatologia , Raiz Dentária/fisiopatologia , Análise de Variância , Animais , Dente Canino , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Preparo de Canal Radicular/instrumentação , Camada de Esfregaço , Propriedades de SuperfícieRESUMO
OBJECTIVES: This in situ study aimed to assess the remineralizing effect of a fluoride toothpaste supplemented with ß-calcium glycerophosphate in both micro (ß-CaGPm) and nano-sized forms (ß-CaGPn). METHODS: This blind and cross-over study was performed in 4 phases, each spanning 3 days. Twelve volunteers utilized palatal appliances containing four bovine enamel blocks with artificial caries lesions. Volunteers were randomly assigned to the following treatment groups: Placebo (no F-ß-CaGPm-ß-CaGPn); 1100 ppm F alone (1100F); 1100F plus 0.5% micrometric ß-CaGP (1100F-0.5%ß-CaGPm); and 1100F plus 0.25%nano-sized ß-CaGP (1100F-0.25%ß-CaGPn). Participants were instructed to brush their natural teeth with the palatal appliances in the mouth for 1 min (3 times/day), ensuring that the enamel blocks were exposed to the natural toothpaste slurries. Following each phase, evaluations were conducted to determine the percentage of surface hardness recovery (%SHR), integrated recovery of subsurface hardness (ΔIHR), profile subsurface lesion through polarized light microscopy (PLM), as well as fluoride (F), calcium (Ca), and phosphorus (P) concentrations within the enamel. Data were analyzed by ANOVA and Student-Newman-Keuls test (p < 0.001). RESULTS: Treatment with 1100F-0.25%ß-CaGPn resulted in %SHR â¼69 % and â¼40 % higher when compared to 1100F and 1100F-0.5%ß-CaGPm (p < 0.001). The reduction in lesion body (ΔIHR; PLM) was â¼40 % higher with 1100F-0.25%ß-CaGPn (p < 0.001) compared to 1100F. The addition of ß-CaGPm and ß-CaGPn did not influence enamel F concentration (p > 0.001). Treatment with 1100F-0.25%ß-CaGPn led to an increase in the concentration of Ca and P in the enamel (p < 0.001). CONCLUSION: The addition of 0.25%ß-CaGPn into 1100F formulation increased the bioavailability of calcium and phosphate, promoting a higher remineralizing effect. CLINICAL SIGNIFICANCE: Toothpaste containing 1100F-0.25%ß-CaGPn showed a potential of higher remineralization to 1100 ppm F and 1100 ppm F micrometric ß-CaGP could be a strategy for patients at caries activity.
Assuntos
Fluoretos , Cremes Dentais , Animais , Bovinos , Humanos , Cálcio/farmacologia , Cariostáticos/farmacologia , Estudos Cross-Over , Esmalte Dentário , Fluoretos/farmacologia , Glicerofosfatos/farmacologia , Dureza , Remineralização Dentária/métodos , Cremes Dentais/farmacologia , Cremes Dentais/uso terapêuticoRESUMO
Photobiomodulation therapy (PTB) is a therapeutic possibility for temporomandibular disorders (TMD), but its effectiveness and protocols for use remain controversial. This study is a RCT that compared the effectiveness of PTB on pain points of the masticatory muscles and TMJs, located through palpation versus application of pre-established points in women with painful TMD, diagnosis by DC/TMD (Diagnostic Criteria for Temporomandibular Disorders - Brazilian Portuguese version). Therefore, a total sample of 54 women, aged between 18 and 60 years, was investigated. Volunteers were randomly randomized and PTB was applied in four different groups with a dose of 4 J and 6 J divided into pre-established application points (PE - G1) and pain points (PD - G2) - Groups 4PE, 4PD, 6PE and 6PD. Four laser applications were performed with a wavelength of 780 nm, one session per week, totaling one month of therapy. The following assessments were performed: DC/TMD, Brief Pain Inventory (BPI), McGill Questionnaire - Short Version (SF-MPQ) and Pain Intensity, Visual Analogue Scale (VAS). Friedman's test was used for within-group comparisons, while the Mann-Whitney test was used for between-group comparisons (p < 0.05). According to the results, laser application on pain points (G2) was more effective. McGill's results showed that regardless of dose, the pain point application group had better outcomes (p = 0.004). Pain intensity evaluation (last days) also showed that application at the pain points was more effective regardless of dose (p = 0.0002). Medians and interquartile deviations showed overall that PTB was more effective at pain points, with a trend towards better outcomes at the 6 J dose. Therefore, it can be concluded that in women with chronic painful TMD, the application of PTB at pain points is more effective than the application at pre-established points. Therefore, individualized PTB protocols are proposed, based on examination palpation of the masticatory structures.
Assuntos
Dor Crônica , Terapia com Luz de Baixa Intensidade , Transtornos da Articulação Temporomandibular , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Dor Crônica/radioterapia , Transtornos da Articulação Temporomandibular/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Medição da Dor , Músculos da MastigaçãoRESUMO
Shaping ability evaluation of taper ./01 instruments in large root canals, by microcomputed tomography (micro-CT) and scanning electron microscopy (SEM). Maxillary central incisors with large diameter root canals were divided into two groups (n = 10): XP-Endo Shaper (FKG-Dentaire, Switzerland) and manual instrumentation (FKG-Dentaire). Two- and three-dimensional parameters from cervical to apical root thirds were evaluated by micro-CT. Apical stop was evaluated by SEM images. Data were analysed by ANOVA and Tukey tests (α = 5%). XP-Endo Shaper allowed a regular biomechanical preparation with less dentinal wear compared with manual instrumentation, which showed excessive wear of the thin root canal walls (p < 0.05). Roundness and SMI showed similarity between both protocols (p > 0.05). XP-Endo Shaper SEM showed a regular and well-defined shape of the apical foramen suggesting the formation of the apical stop. Reduced diameter and taper instruments promoted a conservative wear and a well-defined apical stop formation in large root canals.
Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Preparo de Canal Radicular/métodos , Tratamento do Canal Radicular , Ápice Dentário/diagnóstico por imagemRESUMO
To evaluate the push-out bond strength of the adjustable fiberglass post system to dentin. Twenty maxillary canine roots were endodontically treated and divided into two groups (n=10): conventional fiberglass posts (CFPs) and with single adjustable post (SAP) system. Two slices of each third were subjected to the push-out and failure pattern test and the most apical slice was subjected to analysis of the adhesive interface by scanning electron microscopy (SEM). Data were analyzed by the three-way analysis of variance, Tukey, and Friedman tests, and linear regression (α=0.05). The results showed higher push-out bond strength in the initial time interval for SAP (10.3±5.3, p<0.01). After 6 months, there was reduction in push-out bond strength for both (p<0.001). A higher percentage of adhesive and cohesive failures to dentin. After 6 months areas of maladaptation were noted (p=0.000). The SAP is completed to the promissory root canal in relation to alternative CFP.
Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Colagem Dentária/métodos , Cavidade Pulpar , Vidro , Dentina , Teste de Materiais , Cimentos de Resina/químicaRESUMO
The survival of endodontically treated teeth depends on the remaining tooth structure. The aim of this study was to evaluate the impact of different access cavities on root canal preparation, restorative protocol, and fracture resistance of endodontically treated teeth. Fifty-six mandibular molars were divided into control (n=8) and experimental (n=16) groups according to access cavity: Traditional, Conservative, and Truss; and redistributed (n=8) according to instrumentation protocols: Reciproc Blue and R-motion. After, teeth were scanned in micro-CT and then filled and redistributed according to composite resin restoration (n=8): Filtek One BulkFill and Filtek Z350. A new micro-CT scan was performed to analyze the restorative material. Then, samples were submitted to fracture resistance testing and the failure pattern was determined. Data were analyzed using paired T-test, ANOVA, Tukey, and chi-square tests (α=0.05). In Truss, R-Motion promoted less transportation in different thirds of root canals. Higher percentages of voids (5.05%) and filling material (11.7%) were observed in Truss. Fracture resistance values were higher for the control group, followed by Truss, Conservative, and Traditional. The predominant failure pattern was type-II. In Truss, reciprocating instruments with smaller taper showed less canal transportation. Also, Truss provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material. Thus, in Truss, reciprocating files with smaller taper showed less canal transportation, and these cavities provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material.