Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 345
Filtrar
1.
N Engl J Med ; 389(15): 1380-1389, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37634135

RESUMO

BACKGROUND: The role of catheter ablation in patients with symptomatic atrial fibrillation and end-stage heart failure is unknown. METHODS: We conducted a single-center, open-label trial in Germany that involved patients with symptomatic atrial fibrillation and end-stage heart failure who were referred for heart transplantation evaluation. Patients were assigned to receive catheter ablation and guideline-directed medical therapy or medical therapy alone. The primary end point was a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation. RESULTS: A total of 97 patients were assigned to the ablation group and 97 to the medical-therapy group. The trial was stopped for efficacy by the data and safety monitoring board 1 year after randomization was completed. Catheter ablation was performed in 81 of 97 patients (84%) in the ablation group and in 16 of 97 patients (16%) in the medical-therapy group. After a median follow-up of 18.0 months (interquartile range, 14.6 to 22.6), a primary end-point event had occurred in 8 patients (8%) in the ablation group and in 29 patients (30%) in the medical-therapy group (hazard ratio, 0.24; 95% confidence interval [CI], 0.11 to 0.52; P<0.001). Death from any cause occurred in 6 patients (6%) in the ablation group and in 19 patients (20%) in the medical-therapy group (hazard ratio, 0.29; 95% CI, 0.12 to 0.72). Procedure-related complications occurred in 3 patients in the ablation group and in 1 patient in the medical-therapy group. CONCLUSIONS: Among patients with atrial fibrillation and end-stage heart failure, the combination of catheter ablation and guideline-directed medical therapy was associated with a lower likelihood of a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation than medical therapy alone. (Funded by Else Kröner-Fresenius-Stiftung; CASTLE-HTx ClinicalTrials.gov number, NCT04649801.).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Alemanha , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Encaminhamento e Consulta , Resultado do Tratamento
2.
Circulation ; 148(1): 35-46, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37199171

RESUMO

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Flutter Atrial/etiologia , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
3.
Cardiovasc Diabetol ; 23(1): 78, 2024 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-38402177

RESUMO

OBJECTIVE: We aimed to assess the effect of SGLT2i on arrhythmias by conducting a meta-analysis using data from randomized controlled trials(RCTs). BACKGROUND: Sodium-glucose co-transporter 2 inhibitors (SGLT2i) have shown cardioprotective effects via multiple mechanisms that may also contribute to decrease arrhythmias risk. METHODS: We searched in databases (PubMed, Embase, Cochrane Library, and clinicaltrials.gov) up to April 2023. RCTs comparing SGLT2i with placebo were included. The effects of SGLT2i on atrial fibrillation(AF), atrial flutter(AFL), composite AF/AFL, ventricular fibrillation(VF), ventricular tachycardia(VT), ventricular extrasystoles(VES), sudden cardiac death(SCD) and composite VF/VT/SCD were evaluated. RESULTS: 33 placebo-controlled RCTs were included, comprising 88,098 patients (48,585 in SGLT2i vs. 39,513 in placebo). The mean age was 64.9 ± 9.4 years, 63.0% were male. The mean follow-up was 1.4 ± 1.1 years. The pooled-results showed that SGLT2i was associated with a significantly lower risk of AF [risk ratio(RR): 0.88, 95% confidence interval(CI) 0.78-1.00, P = 0.04] and composite AF/AFL (RR: 0.86, 95%CI 0.77-0.96, P = 0.01). This favorable effect appeared to be substantially pronounced in patients with HFrEF, male gender, dapagliflozin, and > 1 year follow-up. For SCD, only in heart failure patients, SGLT2i were found to be associated with a borderline lower risk of SCD (RR: 0.67, P = 0.05). No significant effects of SGLT2i on other ventricular arrhythmic outcomes were found. CONCLUSIONS: SGLT2i lowers the risks of AF and AF/AFL, and this favorable effect appeared to be particularly pronounced in patients with HFrEF, male gender, dapagliflozin, and longer follow-up (> 1 year). SGLT2i lowers the risk of SCD only in heart failure patients.


Assuntos
Fibrilação Atrial , Compostos Benzidrílicos , Glucosídeos , Insuficiência Cardíaca , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Volume Sistólico , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fibrilação Ventricular
4.
Europace ; 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39298665

RESUMO

Heart Rhythm management is a continuously evolving sub-speciality of cardiology. Every year, many physicians and allied professionals start and complete their training in Cardiac Implantable Electronic Devices (CIED) or Electrophysiology (EP) across the EHRA member countries. While this training ideally ends with an EHRA certification, the description of the learning pathway (what, how, when and where) through an EHRA Core Curriculum is also a prerequisite for a successful training. The first EHRA core curriculum for physicians was published in 2009. Due to the huge developments in the field of electrophysiology and device therapy, this document needed updating. In addition, a certification process for allied professionals has been introduced, as well as a recertification process and accreditation of EHRA recognised training centres. Learning pathways are more individualised now, with Objective Structured Assessment of Technical Skills (OSATS) to monitor learning progression of trainees. The 2024 Updated EHRA Core Curriculum for physicians and allied professionals describes, for both CIED and EP, the syllabus, OSATS, training program and certification and recertification for physicians and allied professionals and stresses the importance of continued medical education after certification. In addition, requirements for accreditation of training centres and trainers are given. Finally, suggested reading lists for CIED and EP are attached as online supplements.

5.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38940494

RESUMO

AIMS: The aim is to describe the rationale, design, delivery, and baseline characteristics of the Stroke prevention and rhythm control Treatment: Evaluation of an Educational programme of the European society of cardiology in a cluster-Randomized trial in patients with Atrial Fibrillation (STEEER-AF) trial. METHODS AND RESULTS: STEEER-AF is a pragmatic trial designed to objectively and robustly determine whether guidelines are adhered to in routine practice and evaluate a targeted educational programme for healthcare professionals. Seventy centres were randomized in six countries (France, Germany, Italy, Poland, Spain, and UK; 2022-23). The STEEER-AF centres recruited 1732 patients with a diagnosis of atrial fibrillation (AF), with a mean age of 68.9 years (SD 11.7), CHA2DS2-VASc score of 3.2 (SD 1.8), and 647 (37%) women. Eight hundred and forty-three patients (49%) were in AF at enrolment and 760 (44%) in sinus rhythm. Oral anticoagulant therapy was prescribed in 1543 patients (89%), with the majority receiving direct oral anticoagulants (1378; 89%). Previous cardioversion, antiarrhythmic drug therapy, or ablation was recorded in 836 patients (48.3%). Five hundred fifty-one patients (31.8%) were currently receiving an antiarrhythmic drug, and 446 (25.8%) were scheduled to receive a future cardioversion or ablation. The educational programme engaged 195 healthcare professionals across centres randomized to the intervention group, consisting of bespoke interactive online learning and reinforcement activities, supported by national expert trainers. CONCLUSION: The STEEER-AF trial was successfully deployed across six European countries to investigate guideline adherence in real-world practice and evaluate if a structured educational programme for healthcare professionals can improve patient-level care. CLINICAL TRIAL REGISTRATION: Clinicaltrials.gov, NCT04396418.


Assuntos
Fibrilação Atrial , Fidelidade a Diretrizes , Guias de Prática Clínica como Assunto , Humanos , Fibrilação Atrial/terapia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/diagnóstico , Feminino , Masculino , Idoso , Europa (Continente) , Pessoa de Meia-Idade , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Projetos de Pesquisa , Cardiologia/normas , Cardiologia/educação , Anticoagulantes/uso terapêutico , Padrões de Prática Médica/normas , Antiarrítmicos/uso terapêutico
6.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38516791

RESUMO

AIMS: Pulmonary vein isolation (PVI) for catheter ablation of atrial fibrillation (AF) is a time-demanding procedure. High-power short-duration (HPSD) ablation protocols and high-density mapping catheters have recently been introduced to clinical practice. We investigated the impact of high-density mapping and HPSD ablation protocols on procedural timing, efficacy, and safety by comparing different standardized set-ups. METHODS AND RESULTS: Three electrophysiology (EP) laboratory set-ups were analysed: (i) circular catheter for mapping and HPSD ablation with 30/35 W guided by an ablation index (AI); (ii) pentaspline catheter for mapping an HPSD ablation with 50 W guided by an AI; and (iii) pentaspline catheter for mapping and HPSD ablation with 90 W over 4 s using a novel ablation catheter. All patients underwent PVI without additional left atrial ablation strategies. Procedural data and operating intervals in the EP laboratory were systematically analysed. Three hundred seven patients were analysed (30/35 W AI: n = 102, 50 W AI: n = 102, 90 W/4 s: n = 103). Skin-to-skin times [105.3 ± 22.7 (30/35 W AI) vs. 81.4 ± 21.3 (50 W AI) vs. 69.5 ± 12.2 (90 W/4 s) min, P ≤ 0.001] and total laboratory times (132.8 ± 42.1 vs. 107.4 ± 25.7 vs. 95.2 ± 14.0 min, P < 0.001) significantly differed among the study groups. Laboratory interval analysis revealed significant shortening of mapping and ablation times. Arrhythmia-free survival after 12 months was not different among the study groups (log-rank P = 0.96). CONCLUSION: The integration of high-density mapping and HPSD protocols into an institutional AF ablation process resulted in reduced procedure times without compromising safety or efficacy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fluxo de Trabalho , Átrios do Coração , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva
7.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38385529

RESUMO

AIMS: Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. METHODS AND RESULTS: FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30 s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10 years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3 min, respectively. Fluoroscopy time was 11.5 ± 7.4 min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. CONCLUSION: In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. REGISTRATION: Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula , Veias Pulmonares , Feminino , Humanos , Masculino , Antiarrítmicos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Constrição Patológica/cirurgia , Fístula/cirurgia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Taquicardia/cirurgia , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso
8.
Europace ; 2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39271126

RESUMO

BACKGROUND: Several algorithms can differentiate inferior axis premature ventricular contractions (PVCs) originating from the right side and left side on 12-lead electrocardiograms (ECGs). However, it is unclear whether distinguishing the origin should rely solely on PVC or incorporate sinus rhythm (SR). AIMS: We compared the Dual-Rhythm model (incorporating both SR and PVC) to the PVC model (using PVC alone), and quantified the contribution of each ECG lead in predicting the PVC origin for each cardiac rotation. METHODS: This multicenter study enrolled 593 patients from 11 centers-493 from Japan and Germany, and 100 from Belgium, which used as the external validation dataset. Using a hybrid approach combining a Resnet50-based convolutional neural network and a Transformer model, we developed two variants-the PVC and Dual-Rhythm models-to predict PVC origin. RESULTS: In the external validation dataset, the Dual-Rhythm model outperformed the PVC model in accuracy (0.84 vs. 0.74, respectively; p < 0.01), precision (0.73 vs. 0.55, respectively; p < 0.01), specificity (0.87 vs. 0.68, respectively; p < 0.01), area under the receiver operating characteristic curve (0.91 vs. 0.86, respectively; p = 0.03), and F1-Score (0.77 vs. 0.68, respectively; p = 0.03). The contributions to PVC origin prediction were 77.3% for PVC and 22.7% for the SR. However, in patients with counterclockwise rotation, SR had a greater contribution in predicting the origin of right-sided PVC. CONCLUSIONS: Our deep learning-based model, incorporating both PVC and SR morphologies, resulted in a higher prediction accuracy for PVC origin. Considering SR is particularly important for predicting right-sided origin in patients with counterclockwise rotation.

9.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38647070

RESUMO

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Técnicas de Sutura , Humanos , Fibrilação Atrial/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Técnicas de Sutura/efeitos adversos , Idoso , Resultado do Tratamento , Alemanha , Fatores de Tempo , Dispositivos de Oclusão Vascular , Deambulação Precoce , Técnicas Hemostáticas/instrumentação
10.
Europace ; 26(5)2024 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-38743765

RESUMO

Imaging using cardiac computed tomography (CT) or magnetic resonance (MR) imaging has become an important option for anatomic and substrate delineation in complex atrial fibrillation (AF) and ventricular tachycardia (VT) ablation procedures. Computed tomography more common than MR has been used to detect procedure-associated complications such as oesophageal, cerebral, and vascular injury. This clinical consensus statement summarizes the current knowledge of CT and MR to facilitate electrophysiological procedures, the current value of real-time integration of imaging-derived anatomy, and substrate information during the procedure and the current role of CT and MR in diagnosing relevant procedure-related complications. Practical advice on potential advantages of one imaging modality over the other is discussed for patients with implanted cardiac rhythm devices as well as for planning, intraprocedural integration, and post-interventional management in AF and VT ablation patients. Establishing a team of electrophysiologists and cardiac imaging specialists working on specific details of imaging for complex ablation procedures is key. Cardiac magnetic resonance (CMR) can safely be performed in most patients with implanted active cardiac devices. Standard procedures for pre- and post-scanning management of the device and potential CMR-associated device malfunctions need to be in place. In VT patients, imaging-specifically MR-may help to determine scar location and mural distribution in patients with ischaemic and non-ischaemic cardiomyopathy beyond evaluating the underlying structural heart disease. Future directions in imaging may include the ability to register multiple imaging modalities and novel high-resolution modalities, but also refinements of imaging-guided ablation strategies are expected.


Assuntos
Consenso , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Valor Preditivo dos Testes , Europa (Continente) , Resultado do Tratamento
11.
Europace ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39331050

RESUMO

BACKGROUND: Advanced ablation strategies are needed to treat ventricular tachycardia (VT) and premature ventricular contractions (PVC) refractory to standard unipolar radiofrequency ablation (Uni-RFA). Bipolar radiofrequency catheter ablation (Bi-RFA) has emerged as a treatment option for refractory VT, PVC. Multicenter registry data on the use of Bi-RFA in the setting of refractory VT and PVC are lacking. PURPOSE: The aim of this Bi-RFA registry is to determine its real-world safety, feasibility, and efficacy in patients with refractory VT/PVC. METHODS: Consecutive patients undergoing Bi-RFA at sixteen European centers for recurring VT/PVC after at least one standard Uni-RFA were included. Second ablation catheter was used instead of a dispersive patch and was positioned at the opposite site of the ablation target. RESULTS: Between March 2021 and August 2024, ninety-one patients underwent 94 Bi-RFA procedures (74 males, age 62±13, prior Uni-RFA range 1-8). Indications were recurrence of PVC (n=56), VT (n=20), electrical storm (n=13), or PVC-triggered ventricular fibrillation (n=2). Procedural time was 160±73min, Bi-RFA time 426±286s, mean Uni-RFA time 819±697s. Elimination of clinical VT/PVC was achieved in 67 (74%) patients, suppression of VT/PVC in a further 10 (11%) patients. In the remaining 14 patients (15%) no effect on VT/PVC was observed. Three major complications occurred: coronary artery occlusion, AV block and arteriovenous fistula. Follow-up lasted 7±8 months. Nineteen (61%) remained VT-free. ≥80% PVC burden reduction was achieved in 45 (78%). CONCLUSIONS: This real-world registry data indicates that Bi-RFA appears safe, is feasible, and effective in the majority of patients with VT/PVC.

12.
J Cardiovasc Electrophysiol ; 34(4): 833-840, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36786515

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. METHODS: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. RESULTS: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged -56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. CONCLUSION: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Átrios do Coração , Fluoroscopia
13.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37410906

RESUMO

Interventional electrophysiology offers a great variety of treatment options to patients suffering from symptomatic cardiac arrhythmia. Catheter ablation of supraventricular and ventricular tachycardia has globally evolved a cornerstone in modern arrhythmia management. Complex interventional electrophysiological procedures engaging multiple ablation tools have been developed over the past decades. Fluoroscopy enabled interventional electrophysiologist throughout the years to gain profound knowledge on intracardiac anatomy and catheter movement inside the cardiac cavities and hence develop specific ablation approaches. However, the application of X-ray technologies imposes serious health risks to patients and operators. To reduce the use of fluoroscopy during interventional electrophysiological procedures to the possibly lowest degree and to establish an optimal protection of patients and operators in cases of fluoroscopy is the main goal of modern radiation management. The present manuscript gives an overview of possible strategies of fluoroscopy reduction and specific radiation protection strategies.


Assuntos
Ablação por Cateter , Exposição à Radiação , Humanos , Arritmias Cardíacas/terapia , Eletrofisiologia Cardíaca , Técnicas Eletrofisiológicas Cardíacas , Fluoroscopia/métodos , Doses de Radiação , Exposição à Radiação/efeitos adversos
14.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37622589

RESUMO

This article will discuss the past, present, and future of ventricular tachycardia ablation and the continuing contribution of the Europace journal as the platform for publication of milestone research papers in this field of ventricular tachycardia ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Ablação por Cateter/efeitos adversos
15.
Europace ; 25(1): 74-82, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36056882

RESUMO

AIMS: REDO-FIRM evaluated safety and effectiveness of conventional vs. focal impulse and rotor modulation (FIRM)-guided ablation of recurrent persistent or paroxysmal atrial fibrillation (AF) after an initial AF ablation procedure. METHODS AND RESULTS: This prospective, multicentre, randomized study included patients with a single prior AF ablation, but with recurrent AF and reconnected pulmonary veins (PVs). Conventional ablation generally included PV re-isolation; however, additional ablation was permitted per physician discretion. In the FIRM arm, beyond PV re-isolation, basket catheter-based FIRM mapping created dynamic animations of putative rotors, which were targeted for ablation. Between May 2016 and July 2019, 269 subjects were randomized, with 243 subjects completing 12-month follow-up. Ablation beyond re-pulmonary vein isolation, the FIRM vs. Conventional arms did not differ significantly: cavo-tricuspid isthmus -9.0% vs. 15.3%, caval vein isolation -1.5% vs. 0.8%, non-PV trigger -2.2% vs. 3.8%, other -11.9% vs. 13.0%. Single procedure 12-month freedom from AF/atrial tachycardia/atrial flutter-recurrence was 63.3% (76/120) vs. 59.0% (72/122) in the FIRM and Conventional arms (P = 0.3503). Efficacy was similar in the paroxysmal and persistent AF subgroups (P = 0.22 and P = 0.48). The 10-day and 12-month safety endpoints were achieved in 93.3% vs. 93.8% (P = 0.89) and 88.4% vs. 93.4% (P = 0.22) in the FIRM and Conventional arms, respectively. CONCLUSIONS: In REDO-FIRM, as compared to standard ablation, FIRM-guided ablation did not provide additional efficacy in redo ablation procedures, but FIRM-guided ablation was equally safe. Additional studies are necessary to identify any potential population able to benefit from FIRM-guided ablation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Estudos Prospectivos , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
16.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37470443

RESUMO

AIMS: Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF. METHODS AND RESULTS: This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days-3 months), and non-early PsAF (>3-12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation. Sinus rhythm (SR) and AF voltage maps were created with the Advisor HD Grid™ Mapping Catheter, Sensor Enabled™ for each subject, and the presence of low-voltage area (LVA) (low-voltage cutoffs: 0.1-1.5 mV) was investigated. Follow-up visits were at 3, 6, and 12 months, with a 24-h Holter monitor at 12 months. A Cox proportional hazards model identified associations between mapping data and 12-month recurrence after a single PVI procedure. The study enrolled 300 subjects (113 PAF, 86 early PsAF, and 101 non-early PsAF) at 18 centres. At 12 months, 75.5% of subjects were free from AF/atrial flutter (AFL)/atrial tachycardia (AT) recurrence. Univariate analysis found that arrhythmia recurrence did not correlate with AF diagnosis, but LVA was significantly correlated. Low-voltage area (<0.5 mV) >28% of the left atrium in SR [hazard ratio (HR): 4.82, 95% confidence interval (CI): 2.08-11.18; P = 0.0003] and >72% in AF (HR: 5.66, 95% CI: 2.34-13.69; P = 0.0001) was associated with a higher risk of AF/AFL/AT recurrence at 12 months. CONCLUSION: Larger extension of LVA was associated with an increased risk of arrhythmia recurrence. These subjects may benefit from substrate modification beyond PVI.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Frequência Cardíaca , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas , Recidiva , Fatores de Tempo , Átrios do Coração , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
17.
Europace ; 25(4): 1392-1399, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36815300

RESUMO

AIMS: Atrial fibrillation (AF) ablation protocols using energy delivery with very high power and short duration (vHPSD) have been introduced to improve lesion formation. This study reports procedural data of vHPSD ablation in AF patients and analyses characteristics of ablation-induced left atrial (LA) scar formation from cardiac magnetic resonance imaging (MRI). METHODS AND RESULTS: Sixty consecutive patients undergoing index pulmonary vein isolation following our institutional Q4U-AF workflow were prospectively enrolled. Ablation was conducted using a contact force sensing catheter allowing for vHPSD ablation using a temperature-controlled ablation mode. Thirty patients underwent cardiac late gadolinium enhancement MRI of the LA 3 months after ablation to assess LA scar. Mean procedural duration was 66.5 ± 14.8 min. Mean ablation time was 4.7 ± 0.9 min with a mean number of 69.9 ± 14.2 applications. First-pass isolation was achieved in 51 patients (85%) for the right pulmonary veins (RPVs), in 37 patients (61.7%) for the left pulmonary veins (LPVs), and in 34 patients (56.7%) for both pulmonary veins (PVs). Magnetic resonance imaging at 3 months post-ablation demonstrated a mean scar width of 14.4 ± 2.6 mm around RPVs and 11.9 ± 1.9 mm at LPVs (P > 0.05). Complete PV encirclement was observed in 76.7% for RPVs, in 76.7% for LPVs, and in 66.7% for both PV pairs. During a mean follow-up of 4.7 ± 1.4 months, arrhythmia recurrence was observed in 3.3% of the patients. CONCLUSION: Pulmonary vein isolation following a novel vHPSD workflow resulted in short procedure duration and high acute and mid-term efficacy. Magnetic resonance imaging demonstrated durable and transmural PV lesions with homogeneous and contiguous scar formation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Meios de Contraste , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Cicatriz/patologia , Fluxo de Trabalho , Gadolínio , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Espectroscopia de Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Veias Pulmonares/patologia , Resultado do Tratamento , Recidiva
18.
Europace ; 25(2): 600-609, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36504238

RESUMO

AIMS: Accessory pathway (AP) ablation is a standard procedure for the treatment of Wolff-Parkinson-White syndrome (WPW). Twelve-lead electrocardiogram (ECG)-based delta wave analysis is essential for predicting ablation sites. Previous algorithms have shown to be complex, time-consuming, and unprecise. We aimed to retrospectively develop and prospectively validate a new, simple ECG-based algorithm considering the patients' heart axis allowing for exact localization of APs in patients undergoing ablation for WPW. METHODS AND RESULTS: Our multicentre study included 211 patients undergoing ablation of a single manifest AP due to WPW between 2013 and 2021. The algorithm was developed retrospectively and validated prospectively by comparing its efficacy to two established ones (Pambrun and Arruda). All patients (32 ± 19 years old, 47% female) underwent successful pathway ablation. Prediction of AP-localization was correct in 197 patients (93%) (sensitivity 92%, specificity 99%, PPV 96%, and NPV 99%). Our algorithm was particularly useful in correctly localizing antero-septal/-lateral (sensitivity and specificity 100%) and posteroseptal (sensitivity 98%, specificity 92%) AP in proximity to the tricuspid valve. The accuracy of EASY-WPW was superior compared to the Pambrun (93% vs. 84%, P = 0.003*) and the Arruda algorithm (94% vs. 75%, P < 0.001*). A subgroup analysis of children (n = 58, 12 ± 4 years old, 55% female) revealed superiority to the Arruda algorithm (P < 0.001*). The reproducibility of our algorithm was excellent (Ï°>0.8; P < 0.001*). CONCLUSION: The novel EASY-WPW algorithm provides reliable and accurate pre-interventional ablation site determination in WPW patients. Only two steps are necessary to locate left-sided AP, and three steps to determine right-sided AP.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Criança , Feminino , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Masculino , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirurgia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Feixe Acessório Atrioventricular/diagnóstico , Feixe Acessório Atrioventricular/cirurgia , Eletrocardiografia/métodos , Algoritmos
19.
Europace ; 25(2): 374-381, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36414239

RESUMO

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Nervo Frênico , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
20.
Pacing Clin Electrophysiol ; 46(12): 1586-1594, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37943015

RESUMO

Pulsed field ablation (PFA) is a promising technology for the treatment of atrial fibrillation (AF). Due to its unique tissue selectivity, PFA potentially bears superior characteristics as compared to established thermal energy sources in AF ablation procedures. Cardiovascular magnetic resonance imaging (CMR) using late gadolinium enhancement (LGE) is an established tool in the analysis of myocardial fibrosis representing atrial cardiomyopathy as well as ablation-induced atrial scar formation following catheter ablation with thermal energy. Mechanisms of atrial lesion formation differ between thermal ablation and electroporation and its impact on results of CMR imaging are not fully understood until now. In this review article, the potential of CMR imaging for PFA lesion assessment and available data are discussed. Further, additional needs to adopt imaging approaches to the cellular mechanisms of electroporation are considered.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Átrios do Coração/patologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/cirurgia , Ablação por Cateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA