Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
Ophthalmic Plast Reconstr Surg ; 37(6): e215-e217, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34314398

RESUMO

Sebaceous carcinoma is characterized by its aggressive local tumor behavior and ability to metastasize. Small periocular sebaceous carcinoma are typically treated by excision with cryotherapy. Larger tumors often require adjuvant external beam radiotherapy (EBRT) and/or exenteration surgery. When used alone, EBRT techniques typically exceed the tolerance of critical normal ocular structures. The interstitial orbital brachytherapy-boost technique permits dose escalation to the tumor bed, while minimizing radiation dose to critical normal ocular structures. Here, we present a case of orbital sebaceous carcinoma treated with excision, cryotherapy, and super-thick amniotic membrane fornix reconstruction. Then, after 3 weeks of healing, adjuvant-combined electron interstitial high-dose rate brachytherapy-boost was added to electron-beam radiotherapy to optimize the orbital radiation dose distribution, increase dose to inferonasal orbit, and allow relative sparing of orbital tissues. At 1-year follow-up, there was no evidence of orbital tumor, no significant eye lash loss, normal ocular motility, no radiation retinopathy, optic neuropathy and a visual acuity of 20/20.


Assuntos
Adenocarcinoma Sebáceo , Braquiterapia , Neoplasias Orbitárias , Lesões por Radiação , Neoplasias das Glândulas Sebáceas , Adenocarcinoma Sebáceo/radioterapia , Humanos , Neoplasias Orbitárias/diagnóstico , Neoplasias Orbitárias/radioterapia , Dosagem Radioterapêutica
2.
Bioinformatics ; 35(12): 2150-2152, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30418481

RESUMO

MOTIVATION: Metagenomics is a powerful tool for assaying the DNA from every genome present in an environment. Recent advances in bioinformatics have enabled the rapid assembly of near-complete metagenome-assembled genomes (MAGs), and there is a need for reproducible pipelines that can annotate and characterize thousands of genomes simultaneously, to enable identification and functional characterization. RESULTS: Here we present MAGpy, a scalable and reproducible pipeline that takes multiple genome assemblies as FASTA and compares them to several public databases, checks quality, suggests a taxonomy and draws a phylogenetic tree. AVAILABILITY AND IMPLEMENTATION: MAGpy is available on github: https://github.com/WatsonLab/MAGpy. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Metagenoma , Software , Metagenômica , Filogenia
3.
Echocardiography ; 36(5): 996-1000, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31006901

RESUMO

Tetralogy of Fallot/Absent Pulmonary Valve (TOF/APV) has been classically associated with the absence of a patent ductus arteriosus (PDA). We present a rare case of APV in TOF with a discontinuous left pulmonary artery (LPA) that was suspected during fetal echocardiogram. Postnatal echocardiogram confirmed the origin of a hypoplastic LPA from the PDA. Despite an aneurysmal (right pulmonary artery) (RPA), axial imaging demonstrated widely patent tracheobronchial system with no evidence of bronchial compression. Clinically, the child required only minimal respiratory support. Genetic testing was positive for 22 q11deletion, commonly associated with this lesion. Surgery consisted of unifocalization of the discontinuous LPA with placement of a valved pulmonary homograft during complete repair of this lesion. Our case highlights the importance of prenatal detection, to aid in the prompt initiation of prostaglandins so as to ensure early rehabilitation of the left lung. Inability to visualize one of the branch pulmonary arteries (PA's) and a PDA on fetal echocardiogram in TOF/APV must raise suspicion for an eccentric branch PA with ductal origin.


Assuntos
Permeabilidade do Canal Arterial/complicações , Ecocardiografia/métodos , Artéria Pulmonar/anormalidades , Valva Pulmonar/anormalidades , Tetralogia de Fallot/complicações , Ultrassonografia Pré-Natal/métodos , Adulto , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/embriologia , Feminino , Humanos , Recém-Nascido , Gravidez , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/embriologia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/embriologia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/embriologia , Adulto Jovem
4.
Bioinformatics ; 33(14): 2207-2208, 2017 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-28334395

RESUMO

MOTIVATION: Oxford Nanopore's MinION device has matured rapidly and is now capable of producing over one million reads and several gigabases of sequence data per run. The nature of the MinION output requires new tools that are easy to use by scientists with a range of computational skills and which enable quick and simple QC and data extraction from MinION runs. RESULTS: We have developed two GUIs for the R package poRe that allow parallel and real-time processing of MinION datasets. Both GUIs are capable of extracting sequence- and meta- data from large MinION datasets via a friendly point-and-click interface using commodity hardware. AVAILABILITY AND IMPLEMENTATION: The GUIs are packaged within poRe which is available on SourceForge: https://sourceforge.net/projects/rpore/files/ . CONTACT: mick.watson@roslin.ed.ac.uk.


Assuntos
Nanoporos , Análise de Sequência de DNA/instrumentação , Software , Gráficos por Computador
5.
Artif Organs ; 42(2): 231-235, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29076174

RESUMO

The VentriFlo True Pulse Pump (Design Mentor, Inc., Pelham, NH, USA) is the first blood pump designed to mimic human arterial waveforms in a standard oxygenation circuit. Our aim was to demonstrate the feasibility and safety of this pump in preparation for future studies to determine possible clinical advantages. We studied four piglets (41.4-46.2 kg): three with an implanted VentriFlo pulsatile pump and one with the nonpulsatile ROTAFLOW pump (MAQUET Holding B.V. & Co. KG, Rastatt, Germany) as a control. Hemodynamics was monitored during 6-h cardiopulmonary bypass (CPB) support and for 2 h after weaning off CPB. The VentriFlo demonstrated physiologic arterial waveforms with arterial pulse pressure of 24.6 ± 5.7 mm Hg. Pump flows (2.0 ± 0.1 L/min in ROTAFLOW; 1.9 ± 0.1 L/min in VentriFlo) and plasma free hemoglobin levels (27.9 ± 12.5 mg/dL in ROTAFLOW; 28.5 ± 14.2 mg/dL in VentriFlo) were also comparable, but systemic O2 extraction (as measured by arterial minus venous O2 saturation) registered slightly higher with the VentriFlo (63.2 ± 6.9%) than the ROTAFLOW (55.4 ± 6.5%). Histological findings showed no evidence of ischemic changes or thromboembolism. This pilot study demonstrated that the VentriFlo system generated pulsatile flow and maintained adequate perfusion of all organs during prolonged CPB.


Assuntos
Ponte Cardiopulmonar/instrumentação , Animais , Desenho de Equipamento , Estudos de Viabilidade , Coração Auxiliar , Hemodinâmica , Fluxo Pulsátil , Suínos
6.
Semin Cancer Biol ; 37-38: 77-95, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26873647

RESUMO

Exposure of cells to any form of ionizing radiation (IR) is expected to induce a variety of DNA lesions, including double strand breaks (DSBs), single strand breaks (SSBs) and oxidized bases, as well as loss of bases, i.e., abasic sites. The damaging potential of IR is primarily related to the generation of electrons, which through their interaction with water produce free radicals. In their turn, free radicals attack DNA, proteins and lipids. Damage is induced also through direct deposition of energy. These types of IR interactions with biological materials are collectively called 'targeted effects', since they refer only to the irradiated cells. Earlier and sometimes 'anecdotal' findings were pointing to the possibility of IR actions unrelated to the irradiated cells or area, i.e., a type of systemic response with unknown mechanistic basis. Over the last years, significant experimental evidence has accumulated, showing a variety of radiation effects for 'out-of-field' areas (non-targeted effects-NTE). The NTE involve the release of chemical and biological mediators from the 'in-field' area and thus the communication of the radiation insult via the so called 'danger' signals. The NTE can be separated in two major groups: bystander and distant (systemic). In this review, we have collected a detailed list of proteins implicated in either bystander or systemic effects, including the clinically relevant abscopal phenomenon, using improved text-mining and bioinformatics tools from the literature. We have identified which of these genes belong to the DNA damage response and repair pathway (DDR/R) and made protein-protein interaction (PPi) networks. Our analysis supports that the apoptosis, TLR-like and NOD-like receptor signaling pathways are the main pathways participating in NTE. Based on this analysis, we formulate a biophysical hypothesis for the regulation of NTE, based on DNA damage and apoptosis gradients between the irradiation point and various distances corresponding to bystander (5mm) or distant effects (5cm). Last but not least, in order to provide a more realistic support for our model, we calculate the expected DSB and non-DSB clusters along the central axis of a representative 200.6MeV pencil beam calculated using Monte Carlo DNA damage simulation software (MCDS) based on the actual beam energy-to-depth curves used in therapy.


Assuntos
Efeito Espectador/efeitos da radiação , Dano ao DNA , Reparo do DNA , Radiação Ionizante , Animais , Dano ao DNA/efeitos da radiação , Reparo do DNA/efeitos da radiação , Regulação da Expressão Gênica/efeitos da radiação , Instabilidade Genômica , Humanos , Proteínas/genética , Proteínas/metabolismo
7.
Am J Obstet Gynecol ; 214(5): 640.e1-6, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26611998

RESUMO

BACKGROUND: It is well known that the maternal cardiovascular system undergoes profound alterations throughout pregnancy. Interest in understanding these changes has led investigators to use evolving and increasingly sophisticated techniques to study these changes, most recently with 2-dimensional echocardiography. Despite its clinical utility, echocardiography has limitations, and cardiac magnetic resonance imaging (CMRI) has become increasingly used for evaluation of cardiac structure and function. OBJECTIVE: We used CMRI to evaluate cardiac remodeling according to maternal habitus throughout pregnancy and postpartum. STUDY DESIGN: This was a prospective, observational study of nulliparous women aged 18-30 years, without preexisting medical conditions, conducted from October 2012 through December 2014. Women were classified according to prepregnancy body mass index (BMI) as either normal (BMI 18.5-24.9 kg/m(2)) or overweight (BMI 25-35 kg/m(2)). All women underwent CMRI during 5 epochs throughout gestation: 12-16 weeks, 26-30 weeks, 32-36 weeks, at delivery, and 3 months' postpartum. Using left ventricular mass (LVM) as a marker of cardiac remodeling, the 2 cohorts were compared. RESULTS: There were 14 normal-weight (BMI 22.2 ± 1.3) and 9 overweight (BMI 29.1 ± 2.0) women who participated in the study. Beginning at 26-30 weeks and continuing to delivery, LVM of both normal-weight and overweight women was significantly increased compared with the respective first-trimester studies for each cohort (P < .001). LVM of both cohorts returned to their index values by 3 months' postpartum. The geometric ratio of LVM to left ventricular end-diastolic volume was calculated, and both normal-weight and overweight women demonstrated concentric remodeling throughout gestation, however this resolved by 12 weeks' postpartum. CONCLUSION: There is substantial cardiac remodeling during pregnancy with significant increases in LVM that are proportional to maternal size. Left ventricular geometric remodeling was concentric in both normal-weight and overweight women. All changes in cardiac remodeling resolved by 3 months' postpartum.


Assuntos
Ventrículos do Coração/anatomia & histologia , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia , Adolescente , Adulto , Índice de Massa Corporal , Feminino , Humanos , Estudos Longitudinais , Sobrepeso , Projetos Piloto , Período Pós-Parto/fisiologia , Gravidez , Estudos Prospectivos , Recuperação de Função Fisiológica/fisiologia , Adulto Jovem
8.
Am J Perinatol ; 32(14): 1318-23, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26375044

RESUMO

OBJECTIVE: To evaluate left ventricular stroke volume (LVSV) and cardiac output (CO) according to maternal position and habitus throughout pregnancy and postpartum using serial cardiac magnetic resonance imaging (c-MRI). STUDY DESIGN: This was a prospective study of normotensive nulliparous women using 1.5-T c-MRI performed in both left lateral decubitus and supine positions during three epochs in pregnancy and at 12 weeks' postpartum. Women were stratified according to prepregnancy body mass indices (BMIs) as normal or overweight/obese and compared for LVSV and CO using repeated measures, mixed-random, and fixed-effects model. RESULTS: Between October 2012 and December 2014, 14 normal-weight (BMI 22.2 ± 1.3) and 9 overweight/obese (BMI 29.1 ± 2.0) women underwent c-MRI. During early pregnancy, position did not alter LVSV or CO for either cohort. Beginning at 26 to 30 weeks and continuing to 32 to 36 weeks, normal-weight women demonstrated significant positional differences for LVSV and CO (both p < 0.01). In contrast, positional differences did not influence these parameters in overweight/obese women. At 12 weeks' postpartum, all influence of position had dissipated for both cohorts. CONCLUSION: Maternal position has no effect on LVSV or CO during the first half of pregnancy. In the second half, however, only normal-weight women exhibit significant changes in cardiac parameters when comparing the left lateral decubitus with supine position.


Assuntos
Constituição Corporal/fisiologia , Débito Cardíaco , Gravidez/fisiologia , Decúbito Dorsal/fisiologia , Função Ventricular Esquerda , Adulto , Índice de Massa Corporal , Feminino , Idade Gestacional , Humanos , Peso Corporal Ideal , Imageamento por Ressonância Magnética , Obesidade/fisiopatologia , Período Pós-Parto/fisiologia , Estudos Prospectivos , Volume Sistólico , Adulto Jovem
9.
Am J Obstet Gynecol ; 211(3): 297.e1-6, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24746998

RESUMO

OBJECTIVE: The objective of the study was to determine whether interpregnancy human immunodeficiency virus (HIV) viral load suppression affects outcomes in subsequent pregnancies. STUDY DESIGN: This is a retrospective review of all women who delivered 2 consecutive pregnancies while diagnosed with HIV from Jan. 1, 1984, until Jan. 1, 2012. Medical records were reviewed for maternal, infant, and delivery data. Pregnancies were divided into index and subsequent pregnancy and analyzed for outcomes. RESULTS: During the study period, 172 HIV-infected women who delivered 2 pregnancies at our institution were identified. There was no difference in median HIV viral load at presentation or delivery between the index and subsequent pregnancies. During the subsequent pregnancy, more women presented on antiretroviral therapy (ART) and more often remained compliant with ART; however, there was no difference in vertical transmission risk between the pregnancies. Of those with a viral load less than 1000 copies/mL at the end of their index pregnancy (n = 103), 57 (55%) presented for their subsequent pregnancy with a viral load still less than 1000 copies/mL. Those women who maintained the viral load suppression between pregnancies were more likely to present for their subsequent pregnancy on ART, maintained a greater viral load suppression and CD4 counts during the pregnancy, and had fewer vertical transmissions compared with those who presented with higher viral loads in their subsequent pregnancy (0% vs 9%, P = .02). CONCLUSION: Maintaining an HIV viral load suppression between pregnancies is associated with improved HIV disease status at delivery in subsequent pregnancies. Interpregnancy HIV viral load suppression is associated with less vertical transmission, emphasizing the importance of maintaining HIV disease control between pregnancies.


Assuntos
HIV/efeitos dos fármacos , Complicações Infecciosas na Gravidez/tratamento farmacológico , Adulto , Antirretrovirais/uso terapêutico , Contagem de Linfócito CD4 , Feminino , Humanos , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Gravidez , Estudos Retrospectivos , Carga Viral
10.
Adv Radiat Oncol ; 9(3): 101425, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38379895

RESUMO

Purpose: Animal studies with ultrahigh dose-rate radiation therapy (FLASH, >40 Gy/s) preferentially spare normal tissues without sacrificing antitumor efficacy compared with conventional dose-rate radiation therapy (CONV). At the University of Washington, we developed a cyclotron-generated preclinical scattered proton beam with FLASH dose rates. We present the technical details of our FLASH radiation system and preliminary biologic results from whole pelvis radiation. Methods and Materials: A Scanditronix MC50 compact cyclotron beamline has been modified to produce a 48.7 MeV proton beam at dose rates between 0.1 and 150 Gy/s. The system produces a 6 cm diameter scattered proton beam (flat to ± 3%) at the target location. Female C57BL/6 mice 5 to 6 weeks old were used for all experiments. To study normal tissue effects in the distal colon, mice were irradiated using the entrance region of the proton beam to the whole pelvis, 18.5 Gy at different dose rates: control, CONV (0.6-1 Gy/s) and FLASH (50-80 Gy/s). Survival was monitored daily and EdU (5-ethynyl-2´-deoxyuridine) staining was performed at 24- and 96-hours postradiation. Cleaved caspase-3 staining was performed 24-hours postradiation. To study tumor control, allograft B16F10 tumors were implanted in the right flank and received 18 Gy CONV or FLASH proton radiation. Tumor growth and survival were monitored. Results: After 18.5 Gy whole pelvis radiation, survival was 100% in the control group, 0% in the CONV group, and 44% in the FLASH group (P < .01). EdU staining showed cell proliferation was significantly higher in the FLASH versus CONV group at both 24-hours and 96-hours postradiation in the distal colon, although both radiation groups showed decreased proliferation compared with controls (P < .05). Lower cleaved caspase-3 staining was seen in the FLASH versus conventional group postradiation (P < .05). Comparable flank tumor control was observed in the CONV and FLASH groups. Conclusions: We present our preclinical FLASH proton radiation system and biologic results showing improved survival after whole pelvis radiation, with equivalent tumor control.

11.
Am J Obstet Gynecol ; 209(3): 267.e1-5, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23727040

RESUMO

OBJECTIVE: The purpose of this study was to analyze the obstetric and neonatal impact of an opioid detoxification program during pregnancy, as well as to examine variables associated with successful opioid detoxification. STUDY DESIGN: This is a retrospective cohort study of women electing inpatient detoxification and subsequently delivering at our hospital from Jan. 1, 2006, through Dec. 31, 2011. Detoxification was considered successful if women had no illicit drug supplementation at the time of delivery. Maternal characteristics were ascertained by chart review and analyzed for variables associated with success. Obstetric and neonatal outcomes were also assessed based on maternal success at delivery. RESULTS: Of the 95 women during the study period with complete data, 53 (56%) were successful. There were no demographic or social risk factors identified associated with success. Women with successful detoxification at delivery had longer inpatient detoxification admissions (median 25 vs 15 days, P < .001) and were less likely to leave prior to completion of the program than women who had relapsed at delivery (9% vs 33%, respectively, P < .001). Infants of mothers who were successfully detoxified had shorter hospitalizations (median 3 vs 22 days, P < .001), lower maximum neonatal abstinence syndrome scores (0 vs 8.3, P < .001), and were less likely to be treated for withdrawal (10% vs 80%, P < .001). CONCLUSION: Opiate detoxification in pregnancy requires a significant time commitment and extended treatment, however, can be successfully achieved in compliant parturients. Importantly, maternal demographics and drug histories do not portend success, supporting continued opiate detoxification being offered to all women expressing intent.


Assuntos
Metadona/uso terapêutico , Transtornos Relacionados ao Uso de Opioides/tratamento farmacológico , Complicações na Gravidez/tratamento farmacológico , Adulto , Estudos de Coortes , Feminino , Humanos , Recém-Nascido , Síndrome de Abstinência Neonatal/tratamento farmacológico , Síndrome de Abstinência Neonatal/epidemiologia , Gravidez , Estudos Retrospectivos
12.
Urology ; 172: 178-181, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36436675

RESUMO

Anterior abdominal wall defects are rare anomalies that can affect multiple organ systems including gastrointestinal, genitourinary, musculoskeletal, and the neurospinal axis. The highly varied, complex anatomy in this patient population creates a challenging reconstruction scenario that merits careful surgical planning. We present an unusual female variant with an anorectal malformation as well as musculoskeletal and genital abnormalities consistent with classic bladder exstrophy in which the urinary bladder, sphincter, and urethra were largely uninvolved.


Assuntos
Anormalidades Múltiplas , Extrofia Vesical , Humanos , Feminino , Extrofia Vesical/cirurgia , Bexiga Urinária/cirurgia , Uretra/cirurgia , Anormalidades Múltiplas/cirurgia , Genitália
13.
Phys Med Biol ; 68(24)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37983905

RESUMO

Fast neutron therapy is a high linear energy transfer (LET) radiation treatment modality offering advantages over low LET radiations. Multileaf collimator technology reduces normal-tissue dose (toxicity) and makes neutron therapy more comparable to MV x-ray treatments. Published clinical-trial and other experiences with fast neutron therapy are reported. Early comparative studies failed to consider differences in target-dose spatial conformality between x-ray and neutron treatments, which is especially important for organs-at-risk close to tumor targets. Treatments planning systems (TPS) for high-energy neutrons lag behind TPS tools for MV x-rays, creating challenges for comparative studies of clinical outcomes. A previously published Monte Carlo model of the University of Washington (UW) Clinical Neutron Therapy System (CNTS) is refined and integrated with the RayStation TPS as an external dose planning/verification tool. The collapsed cone (CC) dose calculations in the TPS are based on measured dose profiles and output factors in water, with the absolute dose determined using a tissue-equivalent ionization chamber. For comparison, independent (external) Monte Carlo simulation computes dose on a voxel-by-voxel basis using an atlas that maps Hounsfield Unit (HU) numbers to elemental composition and density. Although the CC algorithm in the TPS accurately computes neutron dose to water compared to Monte Carlo calculations, calculated dose to water differs from bone or tissue depending largely on hydrogen content. Therefore, the elemental composition of tissue and bone, rather than the material or electron density, affects fast neutron dose. While the CC algorithm suffices for reproducible patient dosimetry in fast neutron therapy, adopting methods that consider tissue heterogeneity would enhance patient-specific neutron dose accuracy relative to national standards for other types of ionizing radiation. Corrections for tissue composition have a significant impact on absolute dose and the relative biological effectiveness (RBE) of neutron treatments compared to other radiation types (MV x-rays, protons, and carbon ions).


Assuntos
Nêutrons Rápidos , Planejamento da Radioterapia Assistida por Computador , Humanos , Nêutrons Rápidos/uso terapêutico , Dosagem Radioterapêutica , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria/métodos , Nêutrons , Água
14.
Phys Med ; 105: 102508, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36549067

RESUMO

PURPOSE: Track structure Monte Carlo (MC) codes have achieved successful outcomes in the quantitative investigation of radiation-induced initial DNA damage. The aim of the present study is to extend a Geant4-DNA radiobiological application by incorporating a feature allowing for the prediction of DNA rejoining kinetics and corresponding cell surviving fraction along time after irradiation, for a Chinese hamster V79 cell line, which is one of the most popular and widely investigated cell lines in radiobiology. METHODS: We implemented the Two-Lesion Kinetics (TLK) model, originally proposed by Stewart, which allows for simulations to calculate residual DNA damage and surviving fraction along time via the number of initial DNA damage and its complexity as inputs. RESULTS: By optimizing the model parameters of the TLK model in accordance to the experimental data on V79, we were able to predict both DNA rejoining kinetics at low linear energy transfers (LET) and cell surviving fraction. CONCLUSION: This is the first study to demonstrate the implementation of both the cell surviving fraction and the DNA rejoining kinetics with the estimated initial DNA damage, in a realistic cell geometrical model simulated by full track structure MC simulations at DNA level and for various LET. These simulation and model make the link between mechanistic physical/chemical damage processes and these two specific biological endpoints.


Assuntos
Dano ao DNA , Prótons , Cricetinae , Animais , Sobrevivência Celular , Cinética , DNA/química , Método de Monte Carlo
15.
Am J Obstet Gynecol ; 207(4): 290.e1-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22901710

RESUMO

OBJECTIVE: We sought to determine if uterine tachysystole, ≥ 6 contractions per 10 minutes, within the first 4 hours of labor induction, is associated with adverse infant outcomes. STUDY DESIGN: This was a prospective cohort study of 584 women ≥ 37 weeks' gestation undergoing induction of labor with 100 µg of oral misoprostol. Fetal heart rate tracings were analyzed for contractions per 10 minutes during the initial 4 hours after misoprostol administration. Patients were analyzed based on the maximum number of contractions per 10 minutes. Infant condition at birth was assessed using the fetal vulnerability composite. RESULTS: Adverse infant outcomes showed no association with increasing number of contractions per 10 minutes. Six or more contractions in 10 minutes were significantly associated with fetal heart rate decelerations (P ≤ .001). Analysis was performed using the maximum number of contractions per 30 minutes with similar results. CONCLUSION: Uterine tachysystole, as currently defined, when occurring remote from delivery is not associated with adverse infant outcomes.


Assuntos
Frequência Cardíaca Fetal/efeitos dos fármacos , Trabalho de Parto Induzido/efeitos adversos , Misoprostol/uso terapêutico , Ocitócicos/uso terapêutico , Contração Uterina/efeitos dos fármacos , Adulto , Feminino , Humanos , Recém-Nascido , Trabalho de Parto Induzido/métodos , Misoprostol/efeitos adversos , Ocitócicos/efeitos adversos , Gravidez , Resultado da Gravidez , Estudos Prospectivos
16.
JACC Case Rep ; 4(24): 101665, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36438891

RESUMO

Surgical treatment of aneurysmal distal congenital coronary artery fistulas depends on size and anatomy. From 2008 to 2021, we applied a new surgical technique in 7 adult patients: proximal and distal fistula closure, opening of aneurysmal artery, and revascularization of branches rising from the fistula under cardiopulmonary bypass and cardiac arrest. (Level of Difficulty: Intermediate.).

17.
Sci Rep ; 12(1): 17934, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36289434

RESUMO

Targeted radiopharmaceutical therapy with alpha-particle emitters (αRPT) is advantageous in cancer treatment because the short range and high local energy deposition of alpha particles enable precise radiation delivery and efficient tumor cell killing. However, these properties create sub-organ dose deposition effects that are not easily characterized by direct gamma-ray imaging (PET or SPECT). We present a computational procedure to determine the spatial distribution of absorbed dose from alpha-emitting radionuclides in tissues using digital autoradiography activity images from an ionizing-radiation quantum imaging detector (iQID). Data from 211At-radioimmunotherapy studies for allogeneic hematopoietic cell transplantation in a canine model were used to develop these methods. Nine healthy canines were treated with 16.9-30.9 MBq 211At/mg monoclonal antibodies (mAb). Lymph node biopsies from early (2-5 h) and late (19-20 h) time points (16 total) were obtained, with 10-20 consecutive 12-µm cryosections extracted from each and imaged with an iQID device. iQID spatial activity images were registered within a 3D volume for dose-point-kernel convolution, producing dose-rate maps. The accumulated absorbed doses for high- and low-rate regions were 9 ± 4 Gy and 1.2 ± 0.8 Gy from separate dose-rate curves, respectively. We further assess uptake uniformity, co-registration with histological pathology, and requisite slice numbers to improve microscale characterization of absorbed dose inhomogeneities in αRPT.


Assuntos
Partículas alfa , Compostos Radiofarmacêuticos , Animais , Cães , Partículas alfa/uso terapêutico , Autorradiografia , Compostos Radiofarmacêuticos/uso terapêutico , Radiometria , Radioisótopos/uso terapêutico , Anticorpos Monoclonais
18.
J Comput Neurosci ; 30(3): 721-8, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21046215

RESUMO

Spiking neural network simulations incorporating variable transmission delays require synaptic events to be scheduled prior to delivery. Conventional methods have memory requirements that scale with the total number of synapses in a network. We introduce novel scheduling algorithms for both discrete and continuous event delivery, where the memory requirement scales instead with the number of neurons. Superior algorithmic performance is demonstrated using large-scale, benchmarking network simulations.


Assuntos
Potenciais de Ação/fisiologia , Algoritmos , Memória/fisiologia , Modelos Neurológicos , Neurônios/fisiologia , Transmissão Sináptica/fisiologia , Animais , Simulação por Computador , Humanos , Rede Nervosa/fisiologia , Sinapses/fisiologia , Fatores de Tempo
19.
Med Phys ; 38(6): 2964-74, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21815370

RESUMO

PURPOSE: To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS: A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two interacting algorithms: (i) a deterministic inverse planning optimization of beamlet intensities that minimizes a weighted sum of quadratic penalty objectives to generate IMRT plans and (ii) an evolutionary algorithm that selects the superior IMRT plans using decision criteria and uses those plans to determine the new weights and penalty objectives of each new plan. Plans resulting from the deterministic algorithm were evaluated by the evolutionary algorithm using a set of decision criteria for both targets and organs at risk (OARs). Decision criteria used included variation in the target dose distribution, mean dose, maximum dose, generalized equivalent uniform dose (gEUD), an equivalent uniform dose (EUD(alpha,beta) formula derived from the linear-quadratic survival model, and points on dose volume histograms (DVHs). In order to quantatively compare results from trials using different decision criteria, a neutral set of comparison metrics was used. For each set of decision criteria investigated, IMRT plans were calculated for four different cases: two simple prostate cases, one complex prostate Case, and one complex head and neck Case. RESULTS: When smaller numbers of decision criteria, more descriptive decision criteria, or less anti-correlated decision criteria were used to characterize plan quality during multiobjective optimization, dose to OARs and target dose variation were reduced in the final population of plans. Mean OAR dose and gEUD (a = 4) decision criteria were comparable. Using maximum dose decision criteria for OARs near targets resulted in inferior populations that focused solely on low target variance at the expense of high OAR dose. Target dose range, (D(max) - D(min)), decision criteria were found to be most effective for keeping targets uniform. Using target gEUD decision criteria resulted in much lower OAR doses but much higher target dose variation. EUD(alpha,beta) based decision criteria focused on a region of plan space that was a compromise between target and OAR objectives. None of these target decision criteria dominated plans using other criteria, but only focused on approaching a different area of the Pareto front. CONCLUSIONS: The choice of decision criteria implemented in the MOEA had a significant impact on the region explored and the rate of convergence toward the Pareto front. When more decision criteria, anticorrelated decision criteria, or decision criteria with insufficient information were implemented, inferior populations are resulted. When more informative decision criteria were used, such as gEUD, EUD(alpha,beta), target dose range, and mean dose, MOEA optimizations focused on approaching different regions of the Pareto front, but did not dominate each other. Using simple OAR decision criteria and target EUD(alpha,beta) decision criteria demonstrated the potential to generate IMRT plans that significantly reduce dose to OARs while achieving the same or better tumor control when clinical requirements on target dose variance can be met or relaxed.


Assuntos
Tomada de Decisões , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Humanos , Masculino , Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/efeitos adversos
20.
Artigo em Inglês | MEDLINE | ID: mdl-21444046

RESUMO

Management of the ventricular septal defect at the time of the double switch operation can be challenging and deserves careful attention to the anatomic details of ventricular septal defect location, alignment with the appropriate subtended ventricles and their respective atrioventricular valves, and the disposition of the specialized conduction tissue. These anatomic details can differ considerably from hearts with concordant atrioventricular alignments, and further variations of right-left geometry and septal alignment can be exhibited. A case is described that underscores some of the particular challenges associated with management of the ventricular septal defect during double switch operation for hearts with discordant atrioventricular connections and either transposition of the great arteries or double outlet right ventricle.


Assuntos
Anormalidades Múltiplas/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Dupla Via de Saída do Ventrículo Direito/cirurgia , Comunicação Interventricular/cirurgia , Anormalidades Múltiplas/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Criança , Dupla Via de Saída do Ventrículo Direito/diagnóstico por imagem , Ecocardiografia Transesofagiana , Seguimentos , Comunicação Interventricular/diagnóstico por imagem , Humanos , Masculino , Cuidados Pós-Operatórios/métodos , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA