Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 51(5): 1268-1286, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38366197

RESUMO

The numbers of diagnostic and therapeutic nuclear medicine agents under investigation are rapidly increasing. Both novel emitters and novel carrier molecules require careful selection of measurement procedures. This document provides guidance relevant to dosimetry for first-in human and early phase clinical trials of such novel agents. The guideline includes a short introduction to different emitters and carrier molecules, followed by recommendations on the methods for activity measurement, pharmacokinetic analyses, as well as absorbed dose calculations and uncertainty analyses. The optimal use of preclinical information and studies involving diagnostic analogues is discussed. Good practice reporting is emphasised, and relevant dosimetry parameters and method descriptions to be included are listed. Three examples of first-in-human dosimetry studies, both for diagnostic tracers and radionuclide therapies, are given.


Assuntos
Medicina Nuclear , Compostos Radiofarmacêuticos , Humanos , Medicina Nuclear/métodos , Radiometria/métodos , Cintilografia , Compostos Radiofarmacêuticos/uso terapêutico , Guias de Prática Clínica como Assunto , Ensaios Clínicos como Assunto
2.
Eur J Nucl Med Mol Imaging ; 50(7): 1861-1868, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37086275

RESUMO

Dosimetry can be a useful tool for personalization of molecular radiotherapy (MRT) procedures, enabling the continuous development of theranostic concepts. However, the additional resource requirements are often seen as a barrier to implementation. This guide discusses the requirements for dosimetry and demonstrates how a dosimetry regimen can be tailored to the available facilities of a centre. The aim is to help centres wishing to initiate a dosimetry service but may not have the experience or resources of some of the more established therapy and dosimetry centres. The multidisciplinary approach and different personnel requirements are discussed and key equipment reviewed example protocols demonstrating these factors are given in the supplementary material for the main therapies carried out in nuclear medicine, including [131I]-NaI for benign thyroid disorders, [177Lu]-DOTATATE and 131I-mIBG for neuroendocrine tumours and [90Y]-microspheres for unresectable hepatic carcinoma.


Assuntos
Tumores Neuroendócrinos , Radiometria , Humanos , Radiometria/métodos , Radioisótopos do Iodo , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/radioterapia , 3-Iodobenzilguanidina
3.
Pediatr Radiol ; 53(12): 2502-2514, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37773444

RESUMO

BACKGROUND: The European-funded Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) project is a multicenter cohort study assessing the long-term effects of ionizing radiation in patients with congenital heart disease. Knowledge is lacking regarding the use of ionizing radiation from sources other than cardiac catheterization in this cohort. OBJECTIVE: This study aims to assess imaging frequency and radiation dose (excluding cardiac catheterization) to patients from a single center participating in the Norwegian HARMONIC project. MATERIALS AND METHODS: Between 2000 and 2020, we recruited 3,609 patients treated for congenital heart disease (age < 18 years), with 33,768 examinations categorized by modality and body region. Data were retrieved from the radiology information system. Effective doses were estimated using International Commission on Radiological Protection Publication 60 conversion factors, and the analysis was stratified into six age categories: newborn; 1 year, 5 years, 10 years, 15 years, and late adolescence. RESULTS: The examination distribution was as follows: 91.0% conventional radiography, 4.0% computed tomography (CT), 3.6% diagnostic fluoroscopy, 1.2% nuclear medicine, and 0.3% noncardiac intervention. In the newborn to 15 years age categories, 4-12% had ≥ ten conventional radiography studies, 1-8% underwent CT, and 0.3-2.5% received nuclear medicine examinations. The median effective dose ranged from 0.008-0.02 mSv and from 0.76-3.47 mSv for thoracic conventional radiography and thoracic CT, respectively. The total effective dose burden from thoracic conventional radiography ranged between 28-65% of the dose burden from thoracic CT in various age categories (40% for all ages combined). The median effective dose for nuclear medicine lung perfusion was 0.6-0.86 mSv and for gastrointestinal fluoroscopy 0.17-0.27 mSv. Because of their low frequency, these procedures contributed less to the total effective dose than thoracic radiography. CONCLUSION: This study shows that CT made the largest contribution to the radiation dose from imaging (excluding cardiac intervention). However, although the dose per conventional radiograph was low, the large number of examinations resulted in a substantial total effective dose. Therefore, it is important to consider the frequency of conventional radiography while calculating cumulative dose for individuals. The findings of this study will help the HARMONIC project to improve risk assessment by minimizing the uncertainty associated with cumulative dose calculations.


Assuntos
Cardiopatias Congênitas , Adolescente , Criança , Humanos , Recém-Nascido , Estudos de Coortes , Fluoroscopia/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Doses de Radiação , Radiação Ionizante , Lactente , Pré-Escolar
4.
Eur J Nucl Med Mol Imaging ; 49(6): 1778-1809, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35284969

RESUMO

The purpose of the EANM Dosimetry Committee is to provide recommendations and guidance to scientists and clinicians on patient-specific dosimetry. Radiopharmaceuticals labelled with lutetium-177 (177Lu) are increasingly used for therapeutic applications, in particular for the treatment of metastatic neuroendocrine tumours using ligands for somatostatin receptors and prostate adenocarcinoma with small-molecule PSMA-targeting ligands. This paper provides an overview of reported dosimetry data for these therapies and summarises current knowledge about radiation-induced side effects on normal tissues and dose-effect relationships for tumours. Dosimetry methods and data are summarised for kidneys, bone marrow, salivary glands, lacrimal glands, pituitary glands, tumours, and the skin in case of radiopharmaceutical extravasation. Where applicable, taking into account the present status of the field and recent evidence in the literature, guidance is provided. The purpose of these recommendations is to encourage the practice of patient-specific dosimetry in therapy with 177Lu-labelled compounds. The proposed methods should be within the scope of centres offering therapy with 177Lu-labelled ligands for somatostatin receptors or small-molecule PSMA.


Assuntos
Lesões por Radiação , Receptores de Somatostatina , Humanos , Ligantes , Lutécio/uso terapêutico , Masculino , Antígeno Prostático Específico , Radioisótopos , Compostos Radiofarmacêuticos/efeitos adversos , Somatostatina
5.
Molecules ; 27(17)2022 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-36080198

RESUMO

A search in PubMed revealed that 72 radionuclides have been considered for molecular or functional targeted radionuclide therapy. As radionuclide therapies increase in number and variations, it is important to understand the role of the radionuclide and the various characteristics that can render it either useful or useless. This review focuses on the physical characteristics of radionuclides that are relevant for radionuclide therapy, such as linear energy transfer, relative biological effectiveness, range, half-life, imaging properties, and radiation protection considerations. All these properties vary considerably between radionuclides and can be optimised for specific targets. Properties that are advantageous for some applications can sometimes be drawbacks for others; for instance, radionuclides that enable easy imaging can introduce more radiation protection concerns than others. Similarly, a long radiation range is beneficial in targets with heterogeneous uptake, but it also increases the radiation dose to tissues surrounding the target, and, hence, a shorter range is likely more beneficial with homogeneous uptake. While one cannot select a collection of characteristics as each radionuclide comes with an unchangeable set, all the 72 radionuclides investigated for therapy-and many more that have not yet been investigated-provide numerous sets to choose between.


Assuntos
Radioisótopos , Meia-Vida , Radioisótopos/uso terapêutico
6.
Eur J Nucl Med Mol Imaging ; 48(6): 1902-1914, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33196921

RESUMO

PURPOSE: 177Lu-lilotomab satetraxetan targets the CD37 antigen and has been investigated in a first-in-human phase 1/2a study for relapsed non-Hodgkin lymphoma (NHL). Tumor dosimetry and response evaluation can be challenging after radioimmunotherapy (RIT). Changes in FDG PET/CT parameters after RIT and correlations with tumor-absorbed doses has not been examined previously in patients with lymphoma. Treatment-induced changes were measured at FDG PET/CT and ceCT to evaluate response at the lesion level after treatment, and correlations with tumor-absorbed doses were investigated. METHODS: Forty-five tumors in 16 patients, with different pre-treatment and pre-dosing regimens, were included. Dosimetry was performed based on multiple SPECT/CT images. FDG PET/CT was performed at baseline and at 3 and 6 months. SUVmax, MTV, TLG, and changes in these parameters were calculated for each tumor. Lesion response was evaluated at 3 and 6 months (PET3months and PET6months) based on Deauville criteria. Anatomical changes based on ceCT at baseline and at 6 and 12 months were investigated by the sum of perpendiculars (SPD). RESULTS: Tumor-absorbed doses ranged from 35 to 859 cGy. Intra- and interpatient variations were observed. Mean decreases in PET parameters from baseline to 3 months were ΔSUVmax-3months 61%, ΔMTV3months 80%, and ΔTLG3months 77%. There was no overall correlation between tumor-absorbed dose and change in FDG PET or ceCT parameters at the lesion level or significant difference in tumor-absorbed doses between metabolic responders and non-responders after treatment. CONCLUSION: Our analysis does not show any correlation between tumor-absorbed doses and changes in FDG PET or ceCT parameters for the included lesions. The combination regimen, including cold antibodies, may be one of the factors precluding such a correlation. Increased intra-patient response with increased tumor-absorbed doses was observed for most patients, implying individual variations in radiation sensitivity or biology. TRIAL REGISTRATION: ClinicalTrials.gov Identifier (NCT01796171). Registered December 2012.


Assuntos
Fluordesoxiglucose F18 , Linfoma não Hodgkin , Anticorpos Monoclonais/uso terapêutico , Humanos , Linfoma não Hodgkin/diagnóstico por imagem , Linfoma não Hodgkin/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
7.
Eur J Nucl Med Mol Imaging ; 48(8): 2437-2446, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33416956

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is effective in selective heart failure (HF) patients, but non-response rate remains high. Positron emission tomography (PET) may provide a better insight into the pathophysiology of left ventricular (LV) remodeling; however, its role for evaluating and selecting patients for CRT remains uncertain. PURPOSE: We investigated if regional LV glucose metabolism in combination with myocardial scar could predict response to CRT. METHODS: Consecutive CRT-eligible HF patients underwent echocardiography, cardiac magnetic resonance (CMR), and 18F-fluorodeoxyglucose (FDG) PET within 1 week before CRT implantation. Echocardiography was additionally performed 12 months after CRT and end-systolic volume reduction ≥ 15% was defined as CRT response. Septal-to-lateral wall (SLR) FDG uptake ratio was calculated from static FDG images. Late gadolinium enhancement (LGE) CMR was analyzed semi-quantitatively to define scar extent. RESULTS: We evaluated 88 patients (67 ± 10 years, 72% males). 18F-FDG SLR showed a linear correlation with volumetric reverse remodeling 12 months after CRT (r = 0.41, p = 0.0001). In non-ischemic HF patients, low FDG SLR alone predicted CRT response with sensitivity and specificity of more than 80%; however, in ischemic HF patients, specificity decreased to 46%, suggesting that in this cohort low SLR can also be caused by the presence of a septal scar. In the multivariate logistic regression model, including low FDG SLR, presence and extent of the scar in each myocardial wall, and current CRT guideline parameters, only low FDG SLR and septal scar remained associated with CRT response. Their combination could predict CRT response with sensitivity, specificity, negative, and positive predictive value of 80%, 83%, 70%, and 90%, respectively. CONCLUSIONS: FDG SLR can be used as a predictor of CRT response and combined with septal scar extent, CRT responders can be distinguished from non-responders with high diagnostic accuracy. Further studies are needed to verify whether this imaging approach can prospectively be used to optimize patient selection.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Cicatriz/diagnóstico por imagem , Meios de Contraste , Feminino , Gadolínio , Glucose , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Masculino , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Remodelação Ventricular
8.
Acta Oncol ; 60(11): 1481-1488, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34425735

RESUMO

BACKGROUND: The aim of this study was to investigate dosimetry data and clinical variables to predict hematological toxicity in non-Hodgkin lymphoma (NHL) patients treated with [177Lutetium]Lu-lilotomab satetraxetan. MATERIAL AND METHODS: A total of 17 patients treated with [177Lu]Lu-lilotomab satetraxetan in a first-in-human phase 1/2a study were included. Absorbed dose to the red marrow was explored using SPECT/CT-imaging of the lumbar vertebrae L2-L4 over multiple time points. Percentage reduction of thrombocytes and neutrophils at nadir compared to baseline (PBN) and time to nadir (TTN) were chosen as indicators of myelosuppression and included as dependent variables. Two models were applied in the analysis, a multivariate linear model and a sigmoidal description of toxicity as a function of absorbed dose. A total of 10 independent patient variables were investigated in the multivariate analysis. RESULTS: Absorbed dose to the red marrow ranged from 1 to 4 Gy. Absorbed dose to the red marrow was found to be the only significant variable for PBN for both thrombocytes and neutrophils. The sigmoid function gave similar results in terms of accuracy when compared to the linear model. CONCLUSION: Myelosuppression in the form of thrombocytopenia and neutropenia in patients treated with [177Lu]Lu-lilotomab satetraxetan can be predicted from the SPECT/CT-derived absorbed dose estimate to the red marrow.


Assuntos
Imunoconjugados , Linfoma não Hodgkin , Anticorpos Monoclonais , Medula Óssea , Humanos , Lutécio/efeitos adversos , Radiometria
9.
Eur J Nucl Med Mol Imaging ; 45(7): 1233-1241, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29470615

RESUMO

PURPOSE: 177Lu-lilotomab satetraxetan is a novel anti-CD37 antibody radionuclide conjugate for the treatment of non-Hodgkin lymphoma (NHL). Four arms with different combinations of pre-dosing and pre-treatment have been investigated in a first-in-human phase 1/2a study for relapsed CD37+ indolent NHL. The aim of this work was to determine the tumor and normal tissue absorbed doses for all four arms, and investigate possible variations in the ratios of tumor to organs-at-risk absorbed doses. METHODS: Two of the phase 1 arms included cold lilotomab pre-dosing (arm 1 and 4; 40 mg fixed and 100 mg/m2 BSA dosage, respectively) and two did not (arms 2 and 3). All patients were pre-treated with different regimens of rituximab. The patients received either 10, 15, or 20 MBq 177Lu-lilotomab satetraxetan per kg body weight. Nineteen patients were included for dosimetry, and a total of 47 lesions were included. The absorbed doses were calculated from multiple SPECT/CT-images and normalized by administered activity for each patient. Two-sided Student's t tests were used for all statistical analyses. RESULTS: Organs with distinct uptake of 177Lu-lilotomab satetraxetan, in addition to tumors, were red marrow (RM), liver, spleen, and kidneys. The mean RM absorbed doses were 0.94, 1.55, 1.44, and 0.89 mGy/MBq for arms 1-4, respectively. For the patients not pre-dosed with lilotomab (arms 2 and 3 combined) the mean RM absorbed dose was 1.48 mGy/MBq, which was significantly higher than for both arm 1 (p = 0.04) and arm 4 (p = 0.02). Of the other organs, the highest uptake was found in the spleen, and there was a significantly lower spleen absorbed dose for arm-4 patients than for the patient group without lilotomab pre-dosing (1.13 vs. 3.20 mGy/MBq; p < 0.01). Mean tumor absorbed doses were 2.15, 2.31, 1.33, and 2.67 mGy/MBq for arms 1-4, respectively. After averaging the tumor absorbed dose for each patient, the patient mean tumor absorbed dose to RM absorbed dose ratios were obtained, given mean values of 1.07 for the patient group not pre-dosed with lilotomab, of 2.16 for arm 1, and of 4.62 for arm 4. The ratios were significantly higher in both arms 1 and 4 compared to the group without pre-dosing (p = 0.05 and p = 0.02). No statistically significant difference between arms 1 and 4 was found. CONCLUSIONS: RM is the primary dose-limiting organ for 177Lu-lilotomab satetraxetan treatment, and pre-dosing with lilotomab has a mitigating effect on RM absorbed dose. Increasing the amount of lilotomab from 40 mg to 100 mg/m2 was found to slightly decrease the RM absorbed dose and increase the ratio of tumor to RM absorbed dose. Still, both pre-dosing amounts resulted in significantly higher tumor to RM absorbed dose ratios. The findings encourage continued use of pre-dosing with lilotomab.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Linfoma não Hodgkin/radioterapia , Radioimunoterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Medula Óssea , Feminino , Humanos , Linfoma não Hodgkin/diagnóstico por imagem , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Radiometria , Dosagem Radioterapêutica , Distribuição Tecidual
12.
Acta Radiol ; 59(2): 132-139, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28509566

RESUMO

Background Yttrium-90 dosimetry after radioembolization is reliant on accurate quantitative imaging of the microsphere deposition. Previous studies have focused on the correction of geometrical resolution effects. Purpose To uncover additional effects of respiratory motion. Material and Methods Mathematical models describing spherical tumors were formed and two blurring effects, limited geometrical resolution and respiratory motion, were simulated. The virtual images were used as basis for dose volume histogram estimations by convolving the radioactivity representations with a dose point kernel. Results For respiratory motion only, the largest errors were found for the smallest tumors and/or tumors with heterogeneous distribution of yttrium-90 microspheres. The deviations in max dose and dose to 25% and 50% of the tumor volume were estimated at 20-40%, 10-30%, and 0-30%, respectively. Additional blurring from geometrical resolution increased the errors to 55-75%, 50-60%, and 25-60%, respectively. Conclusion Respiratory motion contributes to underestimation of tumor dose and overestimation of normal tissue dose.


Assuntos
Fígado/química , Tomografia por Emissão de Pósitrons , Respiração , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Microesferas , Modelos Teóricos , Movimento (Física) , Radiometria , Ítrio
14.
Phys Med ; 117: 103192, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38052710

RESUMO

Absorbed radiation doses are essential in assessing the effects, e.g. safety and efficacy, of radiopharmaceutical therapy (RPT). Patient-specific absorbed dose calculations in the target or the organ at risk require multiple inputs. These include the number of disintegrations in the organ, i.e. the time-integrated activities (TIAs) of the organs, as well as other parameters describing the process of radiation energy deposition in the target tissue (i.e. mean energy per disintegration, radiation dose constants, etc). TIAs are then estimated by incorporating the area under the radiopharmaceutical's time-activity curve (TAC), which can be obtained by quantitative measurements of the biokinetics in the patient (typically based on imaging data such as planar scintigraphy, SPECT/CT, PET/CT, or blood and urine samples). The process of TAC determination/calculation for RPT generally depends on the user, e.g., the chosen number and schedule of measured time points, the selection of the fit function, the error model for the data and the fit algorithm. These decisions can strongly affect the final TIA values and thus the accuracy of calculated absorbed doses. Despite the high clinical importance of the TIA values, there is currently no consensus on processing time-activity data or even a clear understanding of the influence of uncertainties and variations in personalised RPT dosimetry related to user-dependent TAC calculation. As a first step towards minimising site-dependent variability in RPT dosimetry, this work provides an overview of quality assurance and uncertainty management considerations of the TIA estimation.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Radiometria/métodos , Cintilografia
15.
J Nucl Med ; 65(5): 753-760, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38548350

RESUMO

Hematologic toxicity, although often transient, is the most common limiting adverse effect during somatostatin peptide receptor radionuclide therapy. This study investigated the association between Monte Carlo-derived absorbed dose to the red marrow (RM) and hematologic toxicity in patients being treated for their neuroendocrine tumors. Methods: Twenty patients each receiving 4 treatment cycles of [177Lu]Lu-DOTATATE were included. Multiple-time-point 177Lu SPECT/CT imaging-based RM dosimetry was performed using an artificial intelligence-driven workflow to segment vertebral spongiosa within the field of view (FOV). This workflow was coupled with an in-house macroscale/microscale Monte Carlo code that incorporates a spongiosa microstructure model. Absorbed dose estimates to RM in lumbar and thoracic vertebrae within the FOV, considered as representations of the whole-body RM absorbed dose, were correlated with hematologic toxicity markers at about 8 wk after each cycle and at 3- and 6-mo follow-up after completion of all cycles. Results: The median of absorbed dose to RM in lumbar and thoracic vertebrae within the FOV (D median,vertebrae) ranged from 0.019 to 0.11 Gy/GBq. The median of cumulative absorbed dose across all 4 cycles was 1.3 Gy (range, 0.6-2.5 Gy). Hematologic toxicity was generally mild, with no grade 2 or higher toxicity for platelets, neutrophils, or hemoglobin. However, there was a decline in blood counts over time, with a fractional value relative to baseline at 6 mo of 74%, 97%, 57%, and 97%, for platelets, neutrophils, lymphocytes, and hemoglobin, respectively. Statistically significant correlations were found between a subset of hematologic toxicity markers and RM absorbed doses, both during treatment and at 3- and 6-mo follow-up. This included a correlation between the platelet count relative to baseline at 6-mo follow up: D median,vertebrae (r = -0.64, P = 0.015), D median,lumbar (r = -0.72, P = 0.0038), D median,thoracic (r = -0.58, P = 0.029), and D average,vertebrae (r = -0.66, P = 0.010), where D median,lumbar and D median,thoracic are median absorbed dose to the RM in the lumbar and thoracic vertebrae, respectively, within the FOV and D average,vertebrae is the mass-weighted average absorbed dose of all vertebrae. Conclusion: This study found a significant correlation between image-derived absorbed dose to the RM and hematologic toxicity, including a relative reduction of platelets at 6-mo follow up. These findings indicate that absorbed dose to the RM can potentially be used to understand and manage hematologic toxicity in peptide receptor radionuclide therapy.


Assuntos
Medula Óssea , Tumores Neuroendócrinos , Octreotida , Octreotida/análogos & derivados , Compostos Organometálicos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Octreotida/uso terapêutico , Octreotida/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Medula Óssea/efeitos da radiação , Medula Óssea/diagnóstico por imagem , Idoso , Tumores Neuroendócrinos/radioterapia , Tumores Neuroendócrinos/diagnóstico por imagem , Adulto , Radiometria , Doses de Radiação , Método de Monte Carlo , Doenças Hematológicas/diagnóstico por imagem
16.
Phys Med ; 117: 103196, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38104033

RESUMO

PURPOSE: The use of molecular radiotherapy (MRT) has been rapidly evolving over the last years. The aim of this study was to assess the current implementation of dosimetry for MRTs in Europe. METHODS: A web-based questionnaire was open for treating centres between April and June 2022, and focused on 2020-2022. Questions addressed the application of 16 different MRTs, the availability and involvement of medical physicists, software used, quality assurance, as well as the target regions for dosimetry, whether treatment planning and/or verification were performed, and the dosimetric methods used. RESULTS: A total of 173 responses suitable for analysis was received from centres performing MRT, geographically distributed over 27 European countries. Of these, 146 centres (84 %) indicated to perform some form of dosimetry, and 97 % of these centres had a medical physicist available and almost always involved in dosimetry. The most common MRTs were 131I-based treatments for thyroid diseases and thyroid cancer, and [223Ra]RaCl2 for bone metastases. The implementation of dosimetry varied widely between therapies, from almost all centres performing dosimetry-based planning for microsphere treatments to none for some of the less common treatments (like 32P sodium-phosphate for myeloproliferative disease and [89Sr]SrCl2 for bone metastases). CONCLUSIONS: Over the last years, implementation of dosimetry, both for pre-therapeutic treatment planning and post-therapy absorbed dose verification, increased for several treatments, especially for microsphere treatments. For other treatments that have moved from research to clinical routine, the use of dosimetry decreased in recent years. However, there are still large differences both across and within countries.


Assuntos
Radiometria , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Europa (Continente)
17.
J Nucl Med ; 64(7): 1131-1137, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37268424

RESUMO

In preparation for an α-particle therapy trial using 1-7 MBq of 224Ra, the feasibility of tomographic SPECT/CT imaging was of interest. The nuclide decays in 6 steps to stable 208Pb, with 212Pb as the principle photon-emitting nuclide. 212Bi and 208Tl emit high-energy photons up to 2,615 keV. A phantom study was conducted to determine the optimal acquisition and reconstruction protocol. Methods: The spheres of a body phantom were filled with a 224Ra-RaCl2 solution, and the background compartment was filled with water. Images were acquired on a SPECT/CT system. In addition, 30-min scans were acquired for 80- and 240-keV emissions, using triple-energy windows, with both medium-energy and high-energy collimators. Images were acquired at 90-95 and 29-30 kBq/mL, plus an explorative 3-min acquisition at 20 kBq/mL (using only the optimal protocol). Reconstructions were performed with attenuation correction only, attenuation plus scatter correction, 3 levels of postfiltering, and 24 levels of iterative updates. Acquisitions and reconstructions were compared using the maximum value and signal-to-scatter peak ratio for each sphere. Monte Carlo simulations were performed to examine the contributions of key emissions. Results: Secondary photons of the 2,615-keV 208Tl emission produced in the collimators make up most of the acquired energy spectrum, as revealed by Monte Carlo simulations, with only a small fraction (3%-6%) of photons in each window providing useful information for imaging. Still, decent image quality is possible at 30 kBq/mL, and nuclide concentrations are imageable down to approximately 2-5 kBq/mL. The overall best results were obtained with the 240-keV window, medium-energy collimator, attenuation and scatter correction, 30 iterations and 2 subsets, and a 12-mm gaussian postprocessing filter. However, all combinations of the applied collimators and energy windows were capable of producing adequate results, even though some failed to reconstruct the 2 smallest spheres. Conclusion: SPECT/CT imaging of 224Ra in equilibrium with daughters is possible, with sufficient image quality to provide clinical utility for the current trial of intraperitoneally administrated activity. A systematic scheme for optimization was designed to select acquisition and reconstruction settings.


Assuntos
Chumbo , Radioisótopos de Tálio , Fótons , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Cintilografia , Imagens de Fantasmas , Método de Monte Carlo , Processamento de Imagem Assistida por Computador/métodos
18.
Cancers (Basel) ; 15(4)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36831477

RESUMO

PURPOSE: The aim of this paper was to investigate correlations between pre- therapeutic [68Ga]Ga-DOTA-TOC uptake and absorbed dose to tumours from therapy with [177Lu]Lu-DOTA-TATE. METHODS: This retrospective study included 301 tumours from 54 GEP-NET patients. The tumours were segmented on pre-therapeutic [68Ga]Ga-DOTA-TOC PET/CT, and post-therapy [177Lu]Lu-DOTA-TATE SPECT/CT images, using a fixed 40% threshold. The SPECT/CT images were used for absorbed dose calculations by assuming a linear build-up from time zero to day one, and mono-exponential wash-out after that. Both SUVmean and SUVmax were measured from the PET images. A linear absorbed-dose prediction model was formed with SUVmean as the independent variable, and the accuracy was tested with a split 70-30 training-test set. RESULTS: Mean SUVmean and SUVmax from [68Ga]Ga-DOTA-TOC PET was 24.0 (3.6-84.4) and 41.0 (6.7-146.5), and the mean absorbed dose from [177Lu]Lu-DOTA-TATE was 26.9 Gy (2.4-101.9). A linear relationship between SUVmean and [177Lu]Lu-DOTA-TATE activity concentration at 24 h post injection was found (R2 = 0.44, p < 0.05). In the prediction model, a root mean squared error and a mean absolute error of 1.77 and 1.33 Gy/GBq, respectively, were found for the test set. CONCLUSIONS: There was a high inter- and intra-patient variability in tumour measurements, both for [68Ga]Ga-DOTA-TOC SUVs and absorbed doses from [177Lu]Lu-DOTA-TATE. Depending on the required accuracy, [68Ga]Ga-DOTA-TOC PET imaging may estimate the [177Lu]Lu-DOTA-TATE uptake. However, there could be a high variance between predicted and actual absorbed doses.

19.
EJNMMI Phys ; 10(1): 47, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37603123

RESUMO

INTRODUCTION: 212Pb is a promising radionuclide for targeted alpha therapy. Here, the feasibility of visualising the tumour uptake and biodistribution of 212Pb-NG001 in mice with a clinical SPECT/CT scanner was investigated. METHODS: A mouse phantom with 212Pb was imaged with a clinical- and a preclinical SPECT/CT scanner. Different acquisition and reconstruction settings were investigated on the clinical system (Siemens Symbia Intevo Bold). Two athymic nude mice carrying PC-3 PIP prostate cancer tumours of 235-830 µl received 1.44 MBq of 212Pb-NG001 and were imaged 2, 6, and 24 h post-injection on the clinical SPECT/CT with a Medium Energy collimator and a 40% energy window centred on 79 keV. All acquisition times were 30 min, except the mouse imaging 24 h post-injection which was 60 min. After the final imaging, the organs were harvested and measured on a gamma counter to give an indication of how much activity was present in organs of interest at the last imaging time point. RESULTS: Four volumes in the mouse phantom of ~ 300 µl with 246-303 kBq/ml of 212Pb were distinguishable on images acquired with the clinical SPECT/CT with a high number of reconstruction updates. With the preclinical SPECT, the same volumes were easily distinguished with 49 kBq/ml of 212Pb. Clinical SPECT/CT images of the mice revealed uptake in tumours and bladders 2 h after injection and in tumours containing down to approximately 15 kBq/ml at 6 and 24 h after injection. CONCLUSION: Although the preclinical scanner should be used preferentially in biodistribution studies in mice, the clinical SPECT/CT confirmed uptake in small volumes (e.g. ~ 300 µl volume with ~ 250 kBq/ml). Regardless of system, the resolution and sensitivity limits should be carefully determined, otherwise false negative or too low uptakes can be wrongly interpreted.

20.
Semin Nucl Med ; 53(3): 413-425, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36635112

RESUMO

Systemic radioimmunotherapy (RIT) is arguably the most effective and least toxic anticancer treatment for non-Hodgkin lymphoma (NHL). In treatment-naïve patients with indolent NHL, the efficacy of a single injection of RIT compares with that of multiple cycles of combination chemotherapy. However, 20 years following the approval of the first CD20-targeting radioimmunoconjugates 90Y-Ibritumomab-tiuxetan (Zevalin) and 131I-tositumomab (Bexxar), the number of patients referred for RIT in western countries has dramatically decreased. Notwithstanding this, the development of RIT has continued. Therapeutic targets other than CD20 have been identified, new vector molecules have been produced allowing for faster delivery of RIT to the target, and innovative radionuclides with favorable physical characteristics such as alpha emitters have been more widely available. In this article, we reviewed the current status of RIT in NHL, with particular focus on recent clinical and preclinical developments.


Assuntos
Linfoma de Células B , Linfoma não Hodgkin , Radioimunoterapia , Humanos , Linfoma de Células B/radioterapia , Linfoma de Células B/tratamento farmacológico , Linfoma não Hodgkin/radioterapia , Linfoma não Hodgkin/tratamento farmacológico , Radioisótopos de Ítrio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA