Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
AJR Am J Roentgenol ; 219(2): 233-243, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35293233

RESUMO

BACKGROUND. Data are limited regarding utility of positive oral contrast material for peritoneal tumor detection on CT. OBJECTIVE. The purpose of this article is to compare positive versus neutral oral contrast material for detection of malignant deposits in nonsolid intraabdominal organs on CT. METHODS. This retrospective study included 265 patients (133 men, 132 women; median age, 61 years) who underwent an abdominopelvic CT examination in which the report did not suggest presence of malignant deposits and a subsequent CT examination within 6 months in which the report indicated at least one unequivocal malignant deposit. Examinations used positive (iohexol; n = 100) or neutral (water; n = 165) oral agents. A radiologist reviewed images to assess whether the deposits were visible (despite clinical reports indicating no deposits) on unblinded comparison with the follow-up examinations; identified deposits were assigned to one of seven intraabdominal compartments. The radiologist also assessed adequacy of bowel filling with oral contrast material. Two additional radiologists independently reviewed examinations in blinded fashion for malignant deposits. NPV was assessed of clinical CT reports and blinded retrospective readings for detection of malignant deposits visible on unblinded comparison with follow-up examinations. RESULTS. Unblinded review identified malignant deposits in 58.1% (154/265) of examinations. In per-patient analysis of clinical reports, NPV for malignant deposits was higher for examinations with adequate bowel filling with positive oral contrast material (65.8% [25/38]) than for examinations with inadequate bowel filling with positive oral contrast material (45.2% [28/62], p = .07) or with neutral oral contrast material regardless of bowel filling adequacy (35.2% [58/165], p = .002). In per-compartment analysis of blinded interpretations, NPV was higher for examinations with adequate and inadequate bowel filling with positive oral contrast material than for examinations with neutral oral contrast regardless of bowel filling adequacy (reader 1: 94.7% [234/247] and 92.5% [382/413] vs 88.3% [947/1072], both p = .045; reader 2: 93.1% [228/245] and 91.6% [361/394] vs 85.9% [939/1093], both p = .01). CONCLUSION. CT has suboptimal NPV for malignant deposits in intraabdominal nonsolid organs. Compared with neutral material, positive oral contrast material improves detection, particularly with adequate bowel filling. CLINICAL IMPACT. Optimization of bowel preparation for oncologic CT may help avoid potentially severe clinical consequences of missed malignant deposits.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Feminino , Humanos , Intestinos , Iohexol , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
2.
Emerg Radiol ; 29(3): 611-614, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35128620

RESUMO

In this case report, dual-energy CT was critical in the diagnosis of acute mesenteric ischemia by differentiating normal contrast-enhanced bowel and hemorrhagic necrosis. Iodine map showed a segment of small bowel with minimal contrast enhancement, and virtual non-contrast imaging revealed hyperattenuating bowel. This finding changed management for the patient and prevented complications from impending bowel perforation. Histopathological analysis confirmed hemorrhagic necrosis of the bowel segment. In cases of suspected bowel ischemia, dual-energy CT can distinguish bowel wall hemorrhage from contrast enhancement and allow for accurate diagnosis.


Assuntos
Iodo , Isquemia Mesentérica , Meios de Contraste , Hemorragia Gastrointestinal , Humanos , Intestino Delgado , Isquemia , Isquemia Mesentérica/diagnóstico por imagem , Necrose/complicações , Necrose/patologia , Tomografia Computadorizada por Raios X/métodos
3.
Radiographics ; 41(5): 1454-1474, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34357805

RESUMO

Amyloidosis is a group of conditions defined by extracellular deposition of insoluble proteins that can lead to multiorgan dysfunction and failure. The systemic form of the disease is often associated with a plasma cell dyscrasia but may also occur in the setting of chronic inflammation, long-term dialysis, malignancy, or multiple hereditary conditions. Localized forms of the disease most often involve the skin, tracheobronchial tree, and urinary tract and typically require tissue sampling for diagnosis, as they may mimic many conditions including malignancy at imaging alone. Advancements in MRI and nuclear medicine have provided greater specificity for the diagnosis of amyloidosis involving the central nervous system and heart, potentially obviating the need for biopsy of the affected organ in certain circumstances. Specifically, a combination of characteristic findings at noninvasive cardiac MRI and skeletal scintigraphy in patients without an underlying plasma cell dyscrasia is diagnostic for cardiac transthyretin amyloidosis. Histologically, the presence of amyloid is denoted by staining with Congo red and a characteristic apple green birefringence under polarized light microscopy. The imaging features of amyloid vary across each organ system but share some common patterns, such as soft-tissue infiltration and calcification, that may suggest the diagnosis in the appropriate clinical context. The availability of novel therapeutics that target amyloid protein fibrils such as transthyretin highlights the importance of early diagnosis. Online supplemental material is available for this article. ©RSNA, 2021.


Assuntos
Neuropatias Amiloides Familiares , Amiloide , Biópsia , Vermelho Congo , Humanos , Coloração e Rotulagem
4.
Radiographics ; 41(6): 1857-1875, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34597219

RESUMO

Müllerian duct anomalies (MDAs) have important implications for the reproductive health of female patients. In patients with both infertility and recurrent pregnancy loss, the incidence of MDAs is as high as 25%. Congenital uterine anomalies are often only part of a complex set of congenital anomalies involving the cervix, vagina, and urinary tract. Multiple classification systems for MDAs exist, each with different criteria that vary most for the diagnosis of septate uterus. Recognizing the features that guide clinical management is essential for interpretation. Identification of an MDA should prompt evaluation for associated urinary tract anomalies. In patients with infertility who seek to use assisted reproductive technologies such as intrauterine insemination, recognition of MDAs may have an affect on reproductive success, particularly in patients who have an incomplete and clinically occult septum that divides the cervix. Two-dimensional US is the first-line modality for evaluating the uterus and adnexa. Three-dimensional (3D) US or MRI may help to visualize the external uterine fundal contour and internal indentation of the endometrial cavity, which are two morphologic characteristics that are keys to the diagnosis of congenital uterine anomalies. Hysterosalpingo contrast-enhanced US may be performed in conjunction with 3D US to evaluate uterine morphologic characteristics, the endometrial cavity, and tubal patency in a single examination. MRI helps to characterize rudimentary uteri in patients with müllerian hypoplasia and allows assessment for ectopic ureters, abnormally positioned ovaries, or associated deep infiltrative endometriosis. Online supplemental material is available for this article. ©RSNA, 2021.


Assuntos
Ductos Paramesonéfricos , Anormalidades Urogenitais , Colo do Útero/diagnóstico por imagem , Feminino , Fertilidade , Humanos , Ductos Paramesonéfricos/diagnóstico por imagem , Gravidez , Anormalidades Urogenitais/diagnóstico por imagem , Útero/diagnóstico por imagem
5.
J Ultrasound Med ; 40(4): 839-843, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32870519

RESUMO

The diagnosis of ovarian torsion is challenging and relies mostly on morphologic findings. Occasionally, women or children with acute pelvic pain who have undergone an initial ultrasound (US) evaluation with results interpreted as negative for ovarian torsion will return with recurrent or increasing pain, prompting an US reevaluation. The flipped ovary sign refers to a demonstrable change in the orientation of the ovary on follow-up US examinations, recognized by changing positions of ovarian landmarks established by follicles, cysts, or masses. This sign is valuable for identifying ovarian torsion in these patients, even in the absence of classic morphologic or Doppler features of ovarian torsion.


Assuntos
Doenças Ovarianas , Torção Ovariana , Criança , Feminino , Humanos , Doenças Ovarianas/diagnóstico por imagem , Anormalidade Torcional/diagnóstico por imagem , Ultrassonografia
6.
Radiographics ; 39(5): 1327-1355, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31498742

RESUMO

The kidney is the most commonly transplanted solid organ. Advances in surgical techniques, immunosuppression regimens, surveillance imaging, and histopathologic diagnosis of rejection have allowed prolonged graft survival times. However, the demand for kidneys continues to outgrow the available supply, and there are efforts to increase use of donor kidneys with moderate- or high-risk profiles. This highlights the importance of evaluating the renal transplant patient in the context of both donor and recipient risk factors. Radiologists play an integral role within the multidisciplinary team in care of the transplant patient at every stage of the transplant process. In the immediate postoperative period, duplex US is the modality of choice for evaluating the renal allograft. It is useful for establishing a baseline examination for comparison at future surveillance imaging. In the setting of allograft dysfunction, advanced imaging techniques including MRI or contrast-enhanced US may be useful for providing a more specific diagnosis and excluding nonrejection causes of renal dysfunction. When a pathologic diagnosis is deemed necessary to guide therapy, US-guided biopsy is a relatively low-risk, safe procedure. The range of complications of renal transplantation can be organized temporally in relation to the time since surgery and/or according to disease categories, including immunologic (rejection), surgical or iatrogenic, vascular, urinary, infectious, and neoplastic complications. The unique heterotopic location of the renal allograft in the iliac fossa predisposes it to a specific set of complications. As imaging features of infection or malignancy may be nonspecific, awareness of the patient's risk profile and time since transplantation can be used to assign the probability of a certain diagnosis and thus guide more specific diagnostic workup. It is critical to understand variations in vascular anatomy, surgical technique, and independent donor and recipient risk factors to make an accurate diagnosis and initiate appropriate treatment.©RSNA, 2019.


Assuntos
Transplante de Rim , Imagem Multimodal , Complicações Pós-Operatórias/diagnóstico por imagem , Seleção do Doador , Humanos
7.
Radiographics ; 38(5): 1352-1369, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30207931

RESUMO

Although a broad spectrum of entities can induce acute pathologic changes in the small bowel, there are relatively few imaging features that are characteristic of a specific diagnosis on the basis of CT findings. Specific clinical information, including time course and onset of disease, patient risk factors, and any recent pharmacologic or radiation therapy, is often instrumental in refining the differential diagnosis. A wide spectrum of disorders is reviewed in this article; however, given the breadth of disorders associated with the small bowel, neoplastic and infectious conditions affecting the small bowel that can manifest acutely are not specifically discussed. Vascular diseases that can affect the small bowel regionally or diffusely, including thromboembolic and hypoperfusion phenomena, as well as a spectrum of vasculitides, are reviewed. Iatrogenic causes of small bowel disorders are discussed, including angiotensin-converting enzyme inhibitor-induced angioedema, and chemotherapy- and radiation therapy-associated patterns of disease. Autoimmune and hereditary conditions that can affect the small bowel, including systemic lupus erythematosus and genetic C1 esterase inhibitor deficiency, respectively, are reviewed. ©RSNA, 2018.


Assuntos
Enteropatias/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Diagnóstico Diferencial , Humanos , Doença Iatrogênica
11.
Abdom Radiol (NY) ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38980403

RESUMO

OBJECTIVES: To compare the image quality of 1.5T and 3T prostate MRIs of the same post-hip arthroplasty patients, with a specific focus on the degree of susceptibility artifacts. METHODS: This single-center retrospective study included post-hip arthroplasty patients who underwent 1.5T prostate MRIs between 2021 and 2023, as well as comparative 3T prostate MRIs. Three blinded abdominal radiologists retrospectively reviewed their diffusion-weighted imaging (DWI, 50 s/mm2), T2-weighted imaging (T2WI), and dynamic contrast-enhanced imaging (DCE) to evaluate the image quality. The degree of susceptibility artifacts was categorized using a three-point scale, with 3 indicating the least artifact and 1 indicating the most. Image quality was also evaluated using Prostate Imaging Quality (PI-QUAL) version 2. The median of the three raters' scores was compared between 1.5T and 3T prostate MRIs using the Wilcoxon signed-rank test. The inter-rater agreement was evaluated using the multi-rater generalized kappa. RESULTS: Twenty pairs of 1.5T and 3T prostate MRI examinations from 20 unique patients were included. The DWI susceptibility artifact score at 1.5T was significantly higher than at 3T (mean score ± standard deviation, 2.80 ± 0.41 vs. 2.35 ± 0.93, p = 0.014). In contrast, no significant differences were observed in the susceptibility artifact scores in T2WI and DCE, or in the PI-QUAL score. The inter-reader agreement in the susceptibility artifact score was moderate (multi-rater generalized kappa: 0.60) in DWI, perfect in T2WI (not applicable), and substantial (0.65) in DCE. The inter-reader agreement was fair (0.27) in the PI-QUAL score. CONCLUSION: Using 1.5T scanners may be preferable to reduce susceptibility artifacts from hip prostheses in DWI.

12.
Am J Pathol ; 178(3): 1340-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21356384

RESUMO

Epithelial neutrophil-activating peptide-78 (CXCL5), a member of the CXC chemokine family, has been shown to be involved in angiogenesis, tumor growth, and metastasis. The objective of this study was to determine the relationship between CXCL5 expression and tumor progression in human pancreatic cancer and to elucidate the mechanism underlying CXCL5-mediated tumor angiogenesis and cancer growth. We report herein that CXCL5 is overexpressed in human pancreatic cancer compared with paired normal pancreas tissue. Overexpression of CXCL5 is significantly correlated with poorer tumor differentiation, advanced clinical stage, and shorter patient survival. Patients with pancreatic cancer and CXCL5 overexpression who underwent resection of cancer had a mean survival time 25.5 months shorter than that of patients who did not overexpress CXCL5. Blockade of CXCL5 or its receptor CXCR2 by small-interfering RNA knockdown or antibody neutralization attenuated human pancreatic cancer growth in a nude mouse model. Finally, we demonstrated that CXCL5 mediates pancreatic cancer-derived angiogenesis through activation of several signaling pathways, including protein kinase B (Akt), extracellular signal-regulated kinase (ERK), and signal transducer and activator of transcription (STAT) in human endothelial cells. These data suggest that CXCL5 is an important mediator of tumor-derived angiogenesis and that it may serve as a survival factor for pancreatic cancer. Blockade of either CXCL5 or CXCR2 may be a critical adjunct antiangiogenic therapy against pancreatic cancer.


Assuntos
Quimiocina CXCL5/metabolismo , Neoplasias Pancreáticas/metabolismo , Animais , Linhagem Celular Tumoral , Proliferação de Células , Quimiocina CXCL5/genética , Progressão da Doença , Células Endoteliais/enzimologia , MAP Quinases Reguladas por Sinal Extracelular/metabolismo , Regulação Neoplásica da Expressão Gênica , Técnicas de Silenciamento de Genes , Humanos , Camundongos , Camundongos Nus , Neovascularização Patológica/metabolismo , Testes de Neutralização , Neoplasias Pancreáticas/irrigação sanguínea , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/patologia , Fosforilação , Proteínas Proto-Oncogênicas c-akt/metabolismo , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Receptores de Interleucina-8B/metabolismo , Análise de Sobrevida , Ensaios Antitumorais Modelo de Xenoenxerto
13.
Diagnostics (Basel) ; 12(4)2022 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-35453830

RESUMO

Background: Peristalsis-related streak artifacts on the liver compromise image quality and diagnostic accuracy. Purpose: To assess dual-layer spectral-detector computed tomography (CT) image reconstructions for reducing intestinal peristalsis-related streak artifacts on the liver. Methods: We retrospectively evaluated 220 contrast-enhanced abdominal dual-energy CT scans in 131 consecutive patients (mean age: 68 ± 10 years, 120 men) who underwent routine clinical dual-layer spectral-detector CT imaging (120 kVp, 40 keV, 200 keV, virtual non-contrast (VNC), iodine images). Two independent readers evaluated bowel peristalsis streak artifacts on the liver qualitatively on a five-point Likert scale (1 = none to 5 = severe) and quantitatively by depth of streak artifact extension into the liver and measurements of Hounsfield Unit and iodine concentration differences from normal liver. Artifact severity between image reconstructions were compared by Wilcoxon signed-rank and paired t-tests. Results: 12 scans were excluded due to missing spectral data, artifacts on the liver originating from metallic foreign materials, or oral contrast material. Streak artifacts on the liver were seen in 51/208 (25%) scans and involved the left lobe only in 49/51 (96%), the right lobe only in 0/51 (0%), and both lobes in 2/51 (4%) scans. Artifact frequency was lower in iodine than in 120 kVp images (scans 18/208 vs. 51/208, p < 0.001). Artifact severity was less in iodine than in 120 kVp images (median score 1 vs. 3, p < 0.001). Streak artifact extension into the liver was shorter in iodine than 120 kVp images (mean length 2 ± 4 vs. 12 ± 5 mm, p < 0.001). Hounsfield Unit and iodine concentration differed significantly between bright streak artifacts and normal liver in 120 kVp, 40 keV, 200 keV, and VNC images (p < 0.001, each), but not in iodine images (p = 0.23). Conclusion: Intestinal peristalsis-related streak artifacts commonly affect the left liver lobe at CT and can be substantially reduced by viewing iodine dual-energy CT image reconstructions.

14.
Acad Radiol ; 29(2): 287-293, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33341373

RESUMO

RATIONALE AND OBJECTIVES: To assess resident and fellowship program director (PD) perceptions of the abdominal radiology fellowship application process following the first cycle in which an embargo on interviews until December 1, 2019 was set according to the Society of Chairs of Academic Radiology Departments (SCARD) timeline for the 2021-2022 abdominal imaging fellowship year. MATERIALS AND METHODS: Eligible study participants included fellowship PDs of all abdominal imaging programs in the United States and residents that attended the Society of Abdominal Radiology (SAR) 2020 Annual Meeting. A questionnaire was developed by content and survey experts, pilot tested, and administered from May to June 2020. RESULTS: A total of 39% (36/92) of all PDs and 30% (46/152) of all individuals identified as residents with valid email addresses that attended the SAR 2020 Annual Meeting responded to the survey with an overall response rate of 34%. Only 42% of PDs and 33% of residents supported moving to a match, while 62% of PDs and 70% of residents thought that a match would limit the autonomy of applicants. While most PDs and residents also agreed that the first iteration of the SCARD timeline allowed residents to make a more informed choice, the majority of PDs were dissatisfied with their experience. Most PDs and residents additionally want applications to be accepted no earlier than July and/or August of the R3 year (initial SCARD guidelines did not restrict timing), interviews to begin on November 1st or earlier of the R3 year (compared to December 1st set in the first iteration of the guidelines), and a gap of 2-4 weeks between the date of first interviews and notification of first offers (initial SCARD guidelines did not restrict timing). Lastly, an overwhelming majority of PDs and residents agreed that SAR should enforce the abdominal imaging fellowship application process. CONCLUSION: Following the first cycle of abdominal imaging fellowship applications conducted according to the SCARD guidelines, a majority of trainees and PDs felt the changes were favorable and were opposed to a formal match. Specific suggestions for improvement were elicited from stakeholders and will be incorporated for the next cycle.


Assuntos
Internato e Residência , Radiologia , Bolsas de Estudo , Seguimentos , Humanos , Políticas , Radiologia/educação , Inquéritos e Questionários , Estados Unidos
15.
Curr Probl Diagn Radiol ; 51(3): 344-350, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33678528

RESUMO

This review sets forth an approach to performing and interpreting shoulder ultrasound in patients with prior rotator cuff repair and presents a comprehensive review of normal expected findings, postsurgical complications and common artifacts encountered in clinical practice.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Artefatos , Humanos , Complicações Pós-Operatórias/diagnóstico por imagem , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento , Ultrassonografia
16.
Diagnostics (Basel) ; 12(9)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36140556

RESUMO

Purpose: To assess the influence of different dual-energy CT (DECT) scanner techniques on the severity of visceral-motion-related artifacts on the liver. Methods: Two independent readers retrospectively evaluated visceral-motion-related artifacts on the liver on 120-kVp(-like), monoenergetic low- and high-keV, virtual non-contrast (VNC), and iodine images acquired on a dual-source, twin-beam, fast kV-switching, and dual-layer spectral detector scanner. Quantitative assessment: Depth of artifact extension into the liver, measurements of Hounsfield Units (HU) and iodine concentrations. Qualitative assessment: Five-point Likert scale (1 = none to 5 = severe). Artifact severity between image reconstructions were compared by Wilcoxon signed-rank and paired t-tests. Results: 615 contrast-enhanced routine clinical DECT scans of the abdomen were evaluated in 458 consecutive patients (mean age: 61 ± 14 years, 331 men). For dual-source and twin-beam scanners, depth of extension of artifacts into the liver was significantly shorter and artifact severity scores significantly lower for 120-kVp-like images compared with the other image reconstructions (p < 0.001, each). For fast kV-switching and spectral detector scanner images, depth of extension of artifacts was significantly shorter and artifact severity scores significantly lower for iodine images (p < 0.001, each). Dual-source 120-kVp-like and spectral detector iodine images reduced artifacts to an extent that no significant difference in HU or iodine concentrations between artifacts (dual-source: 97 HU, spectral detector: 1.9 mg/mL) and unaffected liver parenchyma (dual-source: 108 HU, spectral detector: 2.1 mg/mL) was measurable (dual-source: p = 0.32, spectral detector: p = 0.15). Conclusion: Visceral-motion-related artifacts on the liver can be markedly reduced by viewing 120-kVp-like images for dual-source and twin-beam DECT scanners and iodine images for fast kV-switching and dual-layer spectral detector DECT scanners.

17.
Curr Probl Diagn Radiol ; 50(6): 825-830, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33041161

RESUMO

INTRODUCTION: Radiology topics receive substantial online media attention, with prior studies focusing on social media platform coverage. We used Google Alerts, a content change detection and notification service, to prospectively analyze new radiology-related content appearing on the internet. MATERIALS AND METHODS: An automated notification was created on Google Alerts for the search term "radiology," sending the user emails with up to 3 new links daily. All links from November 2019 through April 2020 were assessed by 2 of 3 independent raters using a coding system to classify the content source and primary topic of discussion. The top 5 primary topics were retrospectively evaluated to identify prevalent subcategories. Content viewing restrictions were documented. RESULTS: 526 links were accessed. The majority (68%) of links were created by non-radiology lay press, followed by radiology-related lay press (28%), university-based publications (2%), and professional society websites (2%). The primary topic of these links most frequently related to market trends (28%), promotional material (20%), COVID-19 (13%), artificial intelligence (8%), and new technology or equipment (5%). 15% of links discussed a topic sourced from another article, such as a peer-reviewed journal, though only 2 linked directly to the journal itself. 8% of links had content viewing restrictions. CONCLUSION: New radiology content was largely disseminated via non-radiology news sources; radiologists should therefore ensure their research and viewpoints are presented in these outlets. Google Alerts may be a useful tool to stay abreast of the most current public radiology subject matters, especially during these times of social isolation and rapidly evolving clinical practice.


Assuntos
COVID-19 , Radiologia , Inteligência Artificial , Humanos , Internet , Estudos Retrospectivos , SARS-CoV-2 , Ferramenta de Busca
18.
Abdom Radiol (NY) ; 46(12): 5503-5508, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34086093

RESUMO

Traditional teaching methods in radiology education have not kept pace with advances in technology that foster successful transition into independent practice. This deficit has been exacerbated by the COVID-19 pandemic, as the need for social distancing and the introduction of hybrid staffing models have decreased the critical educational interactions at the reading room workstations between staff and trainees. By leveraging interactive, case-based learning, educators have the opportunity to bridge the substantial gap between basic pattern recognition and successfully making a diagnosis in independent practice. For the educator, this signals a shift away from perfect case selection and presenter authority, and toward the role of a guide facilitating an active case-based learning experience. This form of learning is best accompanied by guided interpretation and iterative feedback with the goal of developing similar levels of mastery and autonomy among graduating trainees. In this article, we present the tools and methods for incorporating interactive cases into existing and novel teaching materials to meet the unique challenges educators are facing today.


Assuntos
COVID-19 , Radiologia , Humanos , Pandemias , Radiografia , SARS-CoV-2
19.
Clin Imaging ; 71: 13-16, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33166897

RESUMO

Traumatic testicular rupture is a rare yet serious condition most commonly seen in penetrating trauma victims (e.g. gunshot wounds or motorcycle collisions) that requires immediate surgical management given its potential complications of hypogonadism and infertility. While ultrasound is the most established modality for diagnosing testicular rupture, trauma patients are usually first evaluated with a trauma protocol computed tomography (CT) exam including the chest, abdomen, and pelvis upon presentation, so it is important to recognize CT findings of testicular injury. We present a novel case in which the suspicion for testicular injury was initially raised based upon CT findings of scrotal hematoma/fluid. These findings were then further characterized with ultrasound and confirmed at surgery. In this case, we provide intraoperative imaging that corresponds clearly to findings seen on both CT and ultrasound.


Assuntos
Ferimentos por Arma de Fogo , Ferimentos não Penetrantes , Humanos , Masculino , Ruptura/diagnóstico por imagem , Ruptura/cirurgia , Escroto/diagnóstico por imagem , Escroto/lesões , Escroto/cirurgia , Testículo/diagnóstico por imagem , Testículo/lesões , Testículo/cirurgia , Ultrassonografia , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/cirurgia
20.
Abdom Radiol (NY) ; 46(12): 5462-5465, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34482413

RESUMO

The authors provide a commentary on the current status of the Abdominal Radiology Fellowship recruitment process, which is not presently governed by a formal Match. Abdominal Radiology is the largest radiology subspecialty fellowship that remains outside of the Match. The Society of Abdominal Radiology convened a task force in 2019 to assess stakeholder viewpoints on a Match and found that the community was divided. Radiology departments and Abdominal Radiology fellowship program directors have voluntarily complied with a series of guidelines laid out by the Society of Chairs in Academic Radiology Departments during the two most recent recruiting cycles, but challenges in the process persist. Stakeholders report improved organization and fairness as a result of these procedural changes, and the authors suggest that Abdominal Radiology may continue to consider a formal fellowship Match in coming years.


Assuntos
Internato e Residência , Radiologia , Bolsas de Estudo , Humanos , Seleção de Pessoal , Radiologia/educação , Inquéritos e Questionários , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA