Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Eur J Radiol ; 175: 111426, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38493558

RESUMO

PURPOSE: We aimed to identify the optimal reconstruction settings based on qualitative and quantitative image quality parameters on standard and ultra-high resolution (UHR) images using photon-counting CT (PCCT). METHOD: We analysed 45 patients, 29 with standard and 16 with UHR acquisition, applying both smoother and sharper kernel settings. Coronary CT angiography images were performed on a dual-source PCCT system using standard (0.4/0.6 mm slice thickness, Bv40/Bv44 kernels, QIR levels 0-4) or UHR acquisition (0.2/0.4 mm slice thickness, Bv44/Bv56 kernels, QIR levels 0-4). Qualitative image quality was assessed using a 4-point Likert scale. Image noise (SD), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated in both the proximal and distal segments. RESULTS: On standard resolution, larger slice thickness resulted in an average increase of 12.5 % in CNR, whereas sharper kernel led to an average 8.7 % decrease in CNR. Highest CNR was measured on 0.6 mm, Bv40, QIR4 images and lowest on 0.4 mm, Bv44, QIR0 images: 25.8 ± 4.1vs.8.3 ± 1.6 (p < 0.001). On UHR images, highest CNR was observed on 0.4 mm, Bv40, QIR4 and lowest on 0.2 mm, Bv56 and QIR0 images: 21.5 ± 3.9vs.3.6 ± 0.8 (p < 0.001). Highest qualitative image quality was found on images with Bv44 kernel and QIR level 3/4 with both slice thicknesses on standard reconstruction. Additionally, Bv56 with QIR4 on 0.2 mm slice thickness images showed highest subjective image quality. Preserved distal vessel visualization was detected using QIR 2-4, Bv56 and 0.2 mm slice thickness. CONCLUSIONS: Photon-counting CT demonstrated high qualitative and quantitative image quality for the assessment of coronaries and stents.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Fótons , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído , Doença da Artéria Coronariana/diagnóstico por imagem , Reprodutibilidade dos Testes , Adulto
2.
Eur J Radiol ; 176: 111517, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38805884

RESUMO

PURPOSE: To assess the impact of different quantum iterative reconstruction (QIR) levels on objective and subjective image quality of ultra-high resolution (UHR) coronary CT angiography (CCTA) images and to determine the effect of strength levels on stenosis quantification using photon-counting detector (PCD)-CT. METHOD: A dynamic vessel phantom containing two calcified lesions (25 % and 50 % stenosis) was scanned at heart rates of 60, 80 and 100 beats per minute with a PCD-CT system. In vivo CCTA examinations were performed in 102 patients. All scans were acquired in UHR mode (slice thickness0.2 mm) and reconstructed with four different QIR levels (1-4) using a sharp vascular kernel (Bv64). Image noise, signal-to-noise ratio (SNR), sharpness, and percent diameter stenosis (PDS) were quantified in the phantom, while noise, SNR, contrast-to-noise ratio (CNR), sharpness, and subjective quality metrics (noise, sharpness, overall image quality) were assessed in patient scans. RESULTS: Increasing QIR levels resulted in significantly lower objective image noise (in vitro and in vivo: both p < 0.001), higher SNR (both p < 0.001) and CNR (both p < 0.001). Sharpness and PDS values did not differ significantly among QIRs (all pairwise p > 0.008). Subjective noise of in vivo images significantly decreased with increasing QIR levels, resulting in significantly higher image quality scores at increasing QIR levels (all pairwise p < 0.001). Qualitative sharpness, on the other hand, did not differ across different levels of QIR (p = 0.15). CONCLUSIONS: The QIR algorithm may enhance the image quality of CCTA datasets without compromising image sharpness or accurate stenosis measurements, with the most prominent benefits at the highest strength level.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Imagens de Fantasmas , Fótons , Razão Sinal-Ruído , Humanos , Angiografia por Tomografia Computadorizada/métodos , Masculino , Feminino , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Algoritmos
3.
J Affect Disord ; 363: 47-54, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39029693

RESUMO

BACKGROUND: Affective temperaments are documented predictors of psychopathology, but cumulating data suggest their relationship with coronary artery disease (CAD). We aimed to evaluate their role in relation to surrogate semiquantitative markers of coronary plaque burden, as assessed by coronary CT angiography (CCTA). METHODS: We included 351 patients who were referred for CCTA due to suspected CAD. All patients completed the Temperament Evaluation of Memphis, Pisa, Paris and San Diego Autoquestionnaire (TEMPS-A). The severity and extent of CAD was evaluated by CCTA, applying semiquantitative plaque burden scores, notably Segment Involvement Score (SIS) and Segment Stenosis Score (SSS). Logistic regression analyses were performed to define the predictors of CAD severity and extent. RESULTS: Regarding the scores evaluated by TEMPS-A that consists of 110 questions, in men, significant inverse association was found between hyperthymic temperament score and SSS (ß = -0.143, (95%CI: -0.091 to -0.004), p = 0.034). Compared to the TEMPS-A form, applying the abbreviated version - containing 40 questions - significant relationship between affective temperaments and SSS or SIS was found in case of both sexes. Concerning men, hyperthymic temperament was demonstrated to be independent predictor of both SSS (ß = -0.193, (95%CI: -0.224 to -0.048), p = 0.004) and SIS (ß = -0.194, (95%CI: -0.202 to -0.038), p = 0.004). Additionally, we proved, that significant positive association between irritable temperament and SSS (ß = 0.152, (95%CI: 0.002 to 0.269), p = 0.047) and SIS (ß = 0.155, (95%CI: 0.004 to 0.221), p = 0.042) exists among women. LIMITATIONS: Cross-sectional analysis of a single center study with self-reported questionnaires. CONCLUSIONS: Assessment of affective temperaments could offer added value in stratifying cardiovascular risk for patients beyond traditional risk factors.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Índice de Gravidade de Doença , Temperamento , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/psicologia , Pessoa de Meia-Idade , Idoso , Angiografia Coronária , Afeto
4.
J Cardiovasc Comput Tomogr ; 18(1): 69-74, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38097408

RESUMO

BACKGROUND: We sought to compare the degree of maximal stenosis and the rate of invasive coronary angiography (ICA) recommendations in patients who underwent coronary CT angiography (CCTA) with photon-counting detector CT (PCD-CT) versus those who underwent CCTA with whole heart coverage energy-integrating detector CT (EID-CT). METHODS: In our retrospective single-center study, we included consecutive patients with suspected CAD who underwent CCTA performed with either PCD-CT or a 280-slice EID-CT. The degree of coronary stenosis was classified as no CAD, minimal (1-24 â€‹%), mild (25-49 â€‹%), moderate (50-69 â€‹%), severe stenosis (70-99 â€‹%), or occlusion. RESULTS: A total of 812 consecutive patients were included in the analysis, 401 patients scanned with EID-CT and 411 patients with PCD-CT (mean age: 58.4 â€‹± â€‹12.4 years, 45.4 â€‹% female). Despite the higher total coronary artery calcium score (CACS) in the PCD-CT group (10 [interquartile range (IQR) â€‹= â€‹0-152.8] vs 1 [IQR â€‹= â€‹0-94], p â€‹< â€‹0.001), obstructive CAD was more frequently reported in the EID-CT vs PCD-CT group (no CAD: 28.7 â€‹% vs 26.0 â€‹%, minimal: 23.2 â€‹% vs 30.9 â€‹%, mild: 19.7 â€‹% vs 23.4 â€‹%, moderate: 14.5 â€‹% vs 9.7 â€‹%, severe: 11.5 â€‹% vs 8.5 â€‹% and occlusion: 2.5 â€‹% vs 1.5 â€‹%, respectively, p â€‹= â€‹0.025). EID-CT was independently associated with downstream ICA (OR â€‹= â€‹2.76 [95%CI â€‹= â€‹1.58-4.97] p â€‹< â€‹0.001) in the overall patient population, in patients with CACS<400 (OR â€‹= â€‹2.18 [95%CI â€‹= â€‹1.13-4.39] p â€‹= â€‹0.024) and in patients with CACS≥400 (OR â€‹= â€‹3.83 [95%CI â€‹= â€‹1.42-11.05] p â€‹= â€‹0.010). CONCLUSION: In patients who underwent CCTA with PCD-CT the number of subsequent ICAs was lower as compared to patients who were scanned with EID-CT. This difference was greater in patients with extensive coronary calcification.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Angiografia Coronária , Estudos Retrospectivos , Constrição Patológica , Estudos Prospectivos , Valor Preditivo dos Testes , Encaminhamento e Consulta , Imagens de Fantasmas
5.
Diagnostics (Basel) ; 14(2)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38248031

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) provides non-invasive quantitative assessments of plaque burden and composition. The quantitative assessment of plaque components requires the use of analysis software that provides reproducible semi-automated plaque detection and analysis. However, commercially available plaque analysis software can vary widely in the degree of automation, resulting in differences in terms of reproducibility and time spent. AIM: To compare the reproducibility and time spent of two CCTA analysis software tools using different algorithms for the quantitative assessment of coronary plaque volumes and composition in two independent patient cohorts. METHODS: The study population included 100 patients from two different cohorts: 50 patients from a single-center (Siemens Healthineers, SOMATOM Force (DSCT)) and another 50 patients from a multi-center study (5 different > 64 slice CT scanner types). Quantitative measurements of total calcified and non-calcified plaque volume of the right coronary artery (RCA), left anterior descending (LAD), and left circumflex coronary artery (LCX) were performed on a total of 300 coronaries by two independent readers, using two different CCTA analysis software tools (Tool #1: Siemens Healthineers, syngo.via Frontier CT Coronary Plaque Analysis and Tool #2: Siemens Healthineers, successor CT Coronary Plaque Analysis prototype). In addition, the total time spent for the analysis was recorded with both programs. RESULTS: The patients in cohorts 1 and 2 were 62.8 ± 10.2 and 70.9 ± 11.7 years old, respectively, 10 (20.0%) and 35 (70.0%) were female and 34 (68.0%) and 20 (40.0%), respectively, had hyperlipidemia. In Cohort #1, the inter- and intra-observer variabilities for the assessment of plaque volumes per patient for Tool #1 versus Tool #2 were 22.8%, 22.0%, and 26.0% versus 2.3%, 3.9%, and 2.5% and 19.7%, 21.4%, and 22.1% versus 0.2%, 0.1%, and 0.3%, respectively, for total, noncalcified, and calcified lesions (p < 0.001 for all between Tools #1 and 2 both for inter- and intra-observer). The inter- and intra-observer variabilities using Tool #2 remained low at 2.9%, 2.7%, and 3.0% and 3.8%, 3.7%, and 4.0%, respectively, for total, non-calcified, and calcified lesions in Cohort #2. For each dataset, the median processing time was higher for Tool #1 versus Tool #2 (459.5 s IQR = 348.0-627.0 versus 208.5 s; IQR = 198.0-216.0) (p < 0.001). CONCLUSION: The plaque analysis Tool #2 (CT-guided PCI) encompassing a higher degree of automated support required less manual editing, was more time-efficient, and showed a higher intra- and inter-observer reproducibility for the quantitative assessment of plaque volumes both in a representative single-center and in a multi-center validation cohort.

6.
JAMA Cardiol ; 9(4): 346-356, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38416472

RESUMO

Importance: The effectiveness and safety of computed tomography (CT) and invasive coronary angiography (ICA) in different age groups is unknown. Objective: To determine the association of age with outcomes of CT and ICA in patients with stable chest pain. Design, Setting, and Participants: The assessor-blinded Diagnostic Imaging Strategies for Patients With Stable Chest Pain and Intermediate Risk of Coronary Artery Disease (DISCHARGE) randomized clinical trial was conducted between October 2015 and April 2019 in 26 European centers. Patients referred for ICA with stable chest pain and an intermediate probability of obstructive coronary artery disease were analyzed in an intention-to-treat analysis. Data were analyzed from July 2022 to January 2023. Interventions: Patients were randomly assigned to a CT-first strategy or a direct-to-ICA strategy. Main Outcomes and Measures: MACE (ie, cardiovascular death, nonfatal myocardial infarction, or stroke) and major procedure-related complications. The primary prespecified outcome of this secondary analysis of age was major adverse cardiovascular events (MACE) at a median follow-up of 3.5 years. Results: Among 3561 patients (mean [SD] age, 60.1 [10.1] years; 2002 female [56.2%]), 2360 (66.3%) were younger than 65 years, 982 (27.6%) were between ages 65 to 75 years, and 219 (6.1%) were older than 75 years. The primary outcome was MACE at a median (IQR) follow-up of 3.5 (2.9-4.2) years for 3523 patients (99%). Modeling age as a continuous variable, age, and randomization group were not associated with MACE (hazard ratio, 1.02; 95% CI, 0.98-1.07; P for interaction = .31). Age and randomization group were associated with major procedure-related complications (odds ratio, 1.15; 95% CI, 1.05-1.27; P for interaction = .005), which were lower in younger patients. Conclusions and Relevance: Age did not modify the effect of randomization group on the primary outcome of MACE but did modify the effect on major procedure-related complications. Results suggest that CT was associated with a lower risk of major procedure-related complications in younger patients. Trial Registration: ClinicalTrials.gov Identifier: NCT02400229.


Assuntos
Doença da Artéria Coronariana , Feminino , Humanos , Pessoa de Meia-Idade , Dor no Peito/etiologia , Dor no Peito/diagnóstico , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Masculino , Idoso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA