1.
Int J Med Inform ; 85(1): 76-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26520235

RESUMO

INTRODUCTION: EGMAIN-GX is the computerized physician order entry system used in Japan. The automatic rounding-off of the calculated dose of chemotherapeutic drugs is an update in version 4, compared to version 2. We conducted a comparative study between EGMAIN-GX versions 2 and 4 to estimate the effect of the automatic rounding-off function on ordering time and dose dispersion. METHODS: Twelve hematologists ordered 5 predefined chemotherapeutic regimens most commonly used in treating hematologic malignancies, twice for each regimen. RESULTS: EGMAIN-GX version 4 significantly reduced ordering times compared to version 2 (635s vs. 259s, p<0.01). EGMAIN-GX version 4 also yielded a significantly higher ratio of actual to ideal doses of chemotherapeutic drugs than did version 2 (1.0097 and 0.9997, respectively; p<0.01) and a lower standard deviation (0.0275 and 0.0290, respectively). CONCLUSIONS: The automatic rounding-off function could decrease the ordering time and dose dispersion of chemotherapeutic drugs.


Assuntos
Antineoplásicos/uso terapêutico , Automação , Neoplasias Hematológicas/tratamento farmacológico , Sistemas de Registro de Ordens Médicas , Antineoplásicos/administração & dosagem , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA