Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 29(15): 1420-6, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26147482

RESUMO

RATIONALE: In electrospray droplet impact (EDI) developed in our laboratory, an atmospheric pressure electrospray source has been used. To increase the ion beam intensity and reduce the evacuation load, a vacuum electrospray cluster ion source using a silica capillary was developed. METHODS: A silica capillary with a tip inner diameter of 8 µm was used for vacuum electrospray using aqueous 10% methanol. To stabilize the flow rate of the liquid for nano-electrospray, a home-made constant pressure liquid pump was also developed. RESULTS: By using the silica tip nano-electrospray emitter and a constant pressure pump, stable electrospray with flow rate of 22 nL/min was realized without using any heating system such as laser irradiation. Comparative study of mass spectra obtained by atmospheric pressure EDI (A-EDI) and vacuum EDI (V-EDI) was made for various samples such as thermometer molecule, peptide, polystyrene, Alq(3), NPD, C(60), indium, and SiO(2). V-EDI showed slightly milder ionization than A-EDI. CONCLUSIONS: Because V-EDI gave higher target current (5-10 nA) than A-EDI (a few nA at most), V-EDI secondary ion mass spectrometry (SIMS) would be a useful technique for the surface and interface analysis.


Assuntos
Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Modelos Químicos , Dióxido de Silício , Vácuo
2.
Osteoarthritis Cartilage ; 22(10): 1401-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25278051

RESUMO

OBJECTIVE: Development of the knee joint was morphologically investigated, and the process of cavitation was analyzed by using episcopic fluorescence image capture (EFIC) to create spatial and temporal three-dimensional (3D) reconstructions. METHODS: Knee joints of Wister rat embryos between embryonic day (E)14 and E20 were investigated. Samples were sectioned and visualized using an EFIC. Then, two-dimensional image stacks were reconstructed using OsiriX software, and 3D reconstructions were generated using Amira software. RESULTS: Cavitations of the knee joint were constructed from five divided portions. Cavity formation initiated at multiple sites at E17; among them, the femoropatellar cavity (FPC) was the first. Cavitations of the medial side preceded those of the lateral side. Each cavity connected at E20 when cavitations around the anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) were completed. CONCLUSION: Cavity formation initiated from six portions. In each portion, development proceeded asymmetrically. These results concerning anatomical development of the knee joint using EFIC contribute to a better understanding of the structural feature of the knee joint.


Assuntos
Ligamento Cruzado Anterior/embriologia , Fêmur/embriologia , Imageamento Tridimensional , Articulação do Joelho/embriologia , Imagem Óptica , Ligamento Cruzado Posterior/embriologia , Tíbia/embriologia , Animais , Ligamento Cruzado Anterior/anatomia & histologia , Fêmur/anatomia & histologia , Articulação do Joelho/anatomia & histologia , Ligamento Cruzado Posterior/anatomia & histologia , Ratos , Ratos Wistar , Tíbia/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA