Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Artigo em Alemão | MEDLINE | ID: mdl-34596701

RESUMO

BACKGROUND: The rise of an infectious disease crisis such as the SARS-CoV­2 pandemic posed significant challenges for the administrative structures of the public health service, which resulted in varying levels of efficiency in outbreak management as a function of staffing and digital resources. This substantially impeded the integration of innovative pandemic outbreak management tools. Innovative crisis management, such as cluster tracking, risk group testing, georeferencing, or the integration of wastewater surveillance recommended by the EU Commission, was made significantly more difficult. AIM: In this case study in Berchtesgadener Land, we present the integration of an area-wide georeferenced wastewater surveillance system that captured 95% of the entire population since November 2020. METHODOLOGY: Sampling occurred twice a week at nine municipal wastewater treatment plants and directly from the main sewer at three locations. Samples were pre-treated by centrifugation and subsequently analyzed by digital droplet polymerase chain reaction (PCR) targeting four specific genes of SARS-CoV­2. RESULTS: The integration of an area-wide georeferenced wastewater surveillance system was successful. Wastewater occurrences are plotted for each municipality against cumulative infections over seven days per 100,000 inhabitants. Changes in the infection pattern in individual communities are noticeable ten days ahead of the official case numbers with a sensitivity of approximately 20 in 100,000 inhabitants. DISCUSSION: The integration of this innovative approach to provide a comprehensive overview of the situation by employing a digital dashboard and the use of an early warning system via quantitative wastewater surveillance resulted in very efficient, proactive management, which might serve as a blueprint for other municipalities in Germany.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/epidemiologia , Alemanha/epidemiologia , Humanos , Saúde Pública , Águas Residuárias , Vigilância Epidemiológica Baseada em Águas Residuárias
2.
Chem Res Toxicol ; 32(4): 698-707, 2019 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-30896932

RESUMO

Hydroxylation of polyaromatic compounds through cytochromes P450 (CYPs) is known to result in potentially estrogenic transformation products. Recently, there has been an increasing awareness of the importance of alternative pathways such as aldehyde oxidases (AOX) or N-methyltransferases (NMT) in bioactivation of small molecules, particularly N-heterocycles. Therefore, this study investigated the biotransformation and activity of methylated quinolines, a class of environmentally relevant N-heterocycles that are no native ligands of the estrogen receptor (ER), in the estrogen-responsive cell line ERα CALUX. We found that this widely used cell line overexpresses AOXs and NMTs while having low expression of CYP enzymes. Exposure of ERα CALUX cells to quinolines resulted in estrogenic effects, which could be mitigated using an inhibitor of AOX/NMTs. No such mitigation occurred after coexposure to a CYP1A inhibitor. A number of N-methylated but no hydroxylated transformation products were detected using liquid chromatography-mass spectrometry, which indicated that biotransformations to estrogenic metabolites were likely catalyzed by NMTs. Compared to the natural ER ligand 17ß-estradiol, the products formed during the metabolization of quinolines were weak to moderate agonists of the human ERα. Our findings have potential implications for the risk assessment of these compounds and indicate that care must be taken when using in vitro estrogenicity assays, for example, ERα CALUX, for the characterization of N-heterocycles or environmental samples that may contain them.


Assuntos
Metiltransferases/metabolismo , Quinolinas/metabolismo , Receptores de Estrogênio/metabolismo , Biocatálise , Linhagem Celular Tumoral , Humanos , Metiltransferases/química , Modelos Moleculares , Estrutura Molecular , Quinolinas/química , Proteínas Recombinantes/metabolismo
3.
Anal Biochem ; 546: 58-64, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29412142

RESUMO

Hygiene of drinking water is periodically controlled by cultivation and enumeration of indicator bacteria. Rapid and comprehensive measurements of emerging pathogens are of increasing interest to improve drinking water safety. In this study, the feasibility to detect bacteriophage PhiX174 as a potential indicator for virus contamination in large volumes of water is demonstrated. Three consecutive concentration methods (continuous ultrafiltration, monolithic adsorption filtration, and centrifugal ultrafiltration) were combined to concentrate phages stepwise from 1250 L drinking water into 1 mL. Heterogeneous asymmetric recombinase polymerase amplification (haRPA) is applied as rapid detection method. Field measurements were conducted to test the developed system for hygiene online monitoring under realistic conditions. We could show that this system allows the detection of artificial contaminations of bacteriophage PhiX174 in drinking water pipelines.


Assuntos
Água Potável/microbiologia , Higiene , Técnicas de Amplificação de Ácido Nucleico , Recombinases/metabolismo , Bacteriófago phi X 174/genética , Bacteriófago phi X 174/isolamento & purificação , Microbiologia da Água
4.
Environ Sci Technol ; 48(10): 5892-901, 2014 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-24724806

RESUMO

Heterocyclic aromatic hydrocarbons (hetero-PAHs) are increasingly studied at contaminated sites; especially at former industrial facilities where coal tar-oil was handled, e.g., wood treatment plants, high concentrations of hetero-PAHs are frequently detected in groundwater plumes. In previous studies, fractions of groundwater with high estrogenic activity contained hetero-PAHs and their hydroxylated metabolites. To evaluate this preliminary evidence, selected hetero-PAHs were screened for their estrogenic activity in lyticase yeast estrogen screen (LYES) and ER CALUX. All tested substances were inactive in the LYES. Hetero-PAHs such as acridine, xanthene, indole, 2-methylbenzofuran, 2,3-dimethylbenzofuran, dibenzofuran, dibenzothiophene, quinoline, and 6-methylquinoline were positive in the ER CALUX, with estradiol equivalence factors (EEFs) from 2.85 × 10(-7) to 3.18 × 10(-5). The EEF values of these substances were comparable to those of other xenoestrogens (e.g., alkylphenols or bisphenol A) that are sometimes found in surface water. Chemical analyses revealed that T47Dluc cells could metabolize most of the substances. Among the metabolites (tentatively) identified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) were hydroxides and their keto tautomers, sulfates, sulfoxides, and N-oxides. Because of their high concentrations measured in groundwater, we conclude that hetero-PAHs and metabolites may be a potential risk and should be the subject of further research.


Assuntos
Bioensaio/métodos , Estrogênios/metabolismo , Hidrocarbonetos Policíclicos Aromáticos/metabolismo , Recombinação Genética , Ativação Transcricional , Linhagem Celular Tumoral , Cromatografia Líquida , Intervalos de Confiança , Humanos , Relação Quantitativa Estrutura-Atividade , Receptores de Estrogênio/metabolismo , Espectrometria de Massas em Tandem , Água
5.
Anal Bioanal Chem ; 406(14): 3323-34, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24577571

RESUMO

Pathogenic viruses are emerging contaminants in water which should be analyzed for water safety to preserve public health. A strategy was developed to quantify RNA and DNA viruses in parallel on chemiluminescence flow-through oligonucleotide microarrays. In order to show the proof of principle, bacteriophage MS2, ΦX174, and the human pathogenic adenovirus type 2 (hAdV2) were analyzed in spiked tap water samples on the analysis platform MCR 3. The chemiluminescence microarray imaging unit was equipped with a Peltier heater for a controlled heating of the flow cell. The efficiency and selectivity of DNA hybridization could be increased resulting in higher signal intensities and lower cross-reactivities of polymerase chain reaction (PCR) products from other viruses. The total analysis time for DNA/RNA extraction, cDNA synthesis for RNA viruses, polymerase chain reaction, single-strand separation, and oligonucleotide microarray analysis was performed in 4-4.5 h. The parallel quantification was possible in a concentration range of 9.6 × 10(5)-1.4 × 10(10) genomic units (GU)/mL for bacteriophage MS2, 1.4 × 10(5)-3.7 × 10(8) GU/mL for bacteriophage ΦX174, and 6.5 × 10(3)-1.2 × 10(5) for hAdV2, respectively, by using a measuring temperature of 40 °C. Detection limits could be calculated to 6.6 × 10(5) GU/mL for MS2, 5.3 × 10(3) GU/mL for ΦX174, and 1.5 × 10(2) GU/mL for hAdV2, respectively. Real samples of surface water and treated wastewater were tested. Generally, found concentrations of hAdV2, bacteriophage MS2, and ΦX174 were at the detection limit. Nevertheless, bacteriophages could be identified with similar results by means of quantitative PCR and oligonucleotide microarray analysis on the MCR 3.


Assuntos
Adenoviridae/metabolismo , Levivirus/química , Análise de Sequência com Séries de Oligonucleotídeos/métodos , DNA Viral/análise , Relação Dose-Resposta a Droga , Água Potável , Microbiologia Ambiental , Desenho de Equipamento , Fezes , Humanos , Luminescência , Oligonucleotídeos/química , Reação em Cadeia da Polimerase , RNA Viral/análise , Reprodutibilidade dos Testes , Temperatura , Águas Residuárias , Água/química , Microbiologia da Água , Poluentes da Água
6.
Chemosphere ; 350: 141000, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38135124

RESUMO

Pollution with chloroethenes threaten groundwater resources worldwide. Cis-Dichloroethene (cDCE) and Trichloroethene (TCE) are widespread pollutants that often occur together at contaminated sites, either as primary discharges or as degradation products of anaerobic dechlorination. In this study, comprehensive microcosm experiments were conducted with groundwater samples of seven sites contaminated with chloroethenes. In total, twelve wells with different pollutant concentrations and chloroethene compositions were sampled, and aerobic microcosms including sterile controls were set up. The results revealed interactions as well as interferences between cDCE and TCE. First, co-metabolic cDCE degradation with TCE as growth substrate was detected for the first time in this work. Transformation yields Ty' (molar ratio of co-substrate degraded to primary substrate degraded) of the degradation process were determined and showed a linear relationship with the cDCE/TCE concentration ratio. At low cDCE/TCE ratio, aerobic metabolic TCE degradation can result in complete cDCE removal due to co-metabolic degradation. Secondly, interfering effects were detected at notable cDCE levels resulting in deceleration of TCE degradation and residual concentrations which were also correlating linearly with the cDCE/TCE concentration ratio. These findings are significant for investigating chloroethene contaminated sites and planning remediation strategies. In particular, the efficiency biological remediation methods in the presence of both pollutants can be evaluated more precisely through the knowledge of interactions and interferences. Our study emphasizes that co-contaminants and possible effects of contaminant mixtures on the degradation rates of individual substances should be considered in general.


Assuntos
Poluentes Ambientais , Água Subterrânea , Tricloroetileno , Cloreto de Vinil , Poluentes Químicos da Água , Biodegradação Ambiental , Tricloroetileno/química , Poluentes Químicos da Água/análise , Água Subterrânea/química
7.
Heliyon ; 10(5): e27384, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38486766

RESUMO

Environmental oligotrophic bacteria are suspected to be highly relevant carriers of antimicrobial resistance (AMR). However, there is a lack of validated methods for monitoring in the aquatic environment. Since extended-spectrum ß-lactamases (ESBLs) play a particularly important role in the clinical sector, a culturing method based on R2A-medium spiked with different combinations of ß-lactams was applied to quantify ß-lactamase-producing environmental bacteria from surface waters. In German surface water samples (n = 28), oligotrophic bacteria ranging from 4.0 × 103 to 1.7 × 104 CFU per 100 mL were detected on the nutrient-poor medium spiked with 3rd generation cephalosporins and carbapenems. These numbers were 3 log10 higher compared to ESBL-producing Enterobacteriales of clinical relevance from the same water samples. A MALDI-TOF MS identification of the isolates demonstrated, that the method leads to the isolation of environmentally relevant strains with Pseudomonas, Flavobacterium, and Janthinobacterium being predominant ß-lactam resistant genera. Subsequent micro-dilution antibiotic susceptibility tests (Micronaut-S test) confirmed the expression of ß-lactamases. The qPCR analysis of surface waters DNA extracts showed the presence of ß-lactamase genes (blaTEM, blaCMY-2, blaOXA-48, blaVIM-2, blaSHV, and blaNDM-1) at concentrations of 3.7 (±1.2) to 1.0 (±1.9) log10 gene copies per 100 mL. Overall, the results demonstrate a widespread distribution of cephalosporinase and carbapenemase enzymes in oligotrophic environmental bacteria that have to be considered as a reservoir of ARGs and contribute to the spread of antibiotic resistance.

8.
Heliyon ; 9(2): e13485, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36846709

RESUMO

Trichloroethene (TCE) is one of the most prevalent contaminants in groundwater pollution worldwide. Aerobic-metabolic degradation of TCE has only recently been discovered at one field site. It has significant advantages over aerobic co-metabolism because no auxiliary substrates are required, and the oxygen demand is considerably lower. This study investigated the intrinsic degradation potential as well as the stimulation potential by bioaugmentation in microcosm experiments with groundwater from seven different sites contaminated with chloroethenes. An enrichment culture metabolizing TCE aerobically served as inoculum. The groundwater samples were inoculated with liquid culture in mineral salts medium as well as with immobilized culture on silica sand. Additionally, some samples were inoculated with groundwater from the site where the enrichment culture originated. The microcosms without inoculum proved the occurrence of aerobic TCE-metabolizing bacteria stimulated by the supply of oxygen in 54% of the groundwater samples. TCE degradation started in most cases after adaptation times of up to 92 d. The doubling time of 24 d indicated comparatively slow growth of the aerobic TCE degrading microorganisms. Bioaugmentation triggered or accelerated TCE-degradation in all microcosms with chlorothene concentrations below 100 mg L-1. All inoculation strategies (liquid and immobilized enrichment culture or addition of groundwater from the active field site) were successful. Our study demonstrates that aerobic-metabolic TCE degradation can occur and be stimulated across a broad hydrogeologic spectrum and should be considered as a viable option for groundwater remediation at TCE-contaminated sites.

9.
Environ Sci Pollut Res Int ; 30(49): 107673-107680, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37735338

RESUMO

Chloroethenes are globally prevalent groundwater contaminants. Since 2014, TCE has been shown to be degradable in an aerobic metabolic process where it is used as sole energy source and growth substrate by a mixed bacteria culture (SF culture). In 2019, the SF culture was shown to be successfully used in bioaugmentation approaches under field-relevant conditions. In this study, a combined bio-/electro-approach to stimulate the TCE degradation by the SF culture was investigated in laboratory experiments. Column experiments were set up to compare a bioaugmentation approach with an electrochemical biostimulated bioaugmentation approach. Low strength direct current increased the amount of degraded TCE to about 150 % of the control. Through lowering the inflow concentration of oxygen, the effect of the electro-biostimulation in a low oxygen setting confirmed the potential of the bio-electro process for treatment of oxygen-deprived, TCE-contaminated sites.


Assuntos
Água Subterrânea , Poluentes Químicos da Água , Biodegradação Ambiental , Poluentes Químicos da Água/metabolismo , Aerobiose , Água Subterrânea/microbiologia , Oxigênio
10.
Int J Hyg Environ Health ; 253: 114241, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37611533

RESUMO

With the advent of molecular biology diagnostics, different quantitative PCR assays have been developed for use in Source Tracking (ST), with none of them showing 100% specificity and sensitivity. Most studies have been conducted at a regional level and mainly in fecal slurry rather than in animal wastewater. The use of a single molecular assay has most often proven to fall short in discriminating with precision the sources of fecal contamination. This work is a multicenter European ST study to compare bacterial and mitochondrial molecular assays and was set to evaluate the efficiency of nine previously described qPCR assays targeting human-, cow/ruminant-, pig-, and poultry-associated fecal contamination. The study was conducted in five European countries with seven fecal indicators and nine ST assays being evaluated in a total of 77 samples. Animal fecal slurry samples and human and non-human wastewater samples were analyzed. Fecal indicators measured by culture and qPCR were generally ubiquitous in the samples. The ST qPCR markers performed at high levels in terms of quantitative sensitivity and specificity demonstrating large geographical application. Sensitivity varied between 73% (PLBif) and 100% for the majority of the tested markers. On the other hand, specificity ranged from 53% (CWMit) and 97% (BacR). Animal-associated ST qPCR markers were generally detected in concentrations greater than those found for the respective human-associated qPCR markers, with mean concentration for the Bacteroides qPCR markers varying between 8.74 and 7.22 log10 GC/10 mL for the pig and human markers, respectively. Bacteroides spp. and mitochondrial DNA qPCR markers generally presented higher Spearman's rank coefficient in the pooled fecal samples tested, particularly the human fecal markers with a coefficient of 0.79. The evaluation of the performance of Bacteroides spp., mitochondrial DNA and Bifidobacterium spp. ST qPCR markers support advanced pollution monitoring of impaired aquatic environments, aiming to elaborate strategies for target-oriented water quality management.


Assuntos
DNA Mitocondrial , Águas Residuárias , Bovinos , Feminino , Animais , Suínos , Bacteroides/genética , Bioensaio , Qualidade da Água
11.
Sci Total Environ ; 903: 166540, 2023 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-37634730

RESUMO

Wastewater-based SARS-CoV-2 epidemiology (WBE) has proven as an excellent tool to monitor pandemic dynamics supporting individual testing strategies. WBE can also be used as an early warning system for monitoring the emergence of novel pathogens or viral variants. However, for a timely transmission of results, sophisticated sample logistics and analytics performed in decentralized laboratories close to the sampling sites are required. Since multiple decentralized laboratories commonly use custom in-house workflows for sample purification and PCR-analysis, comparative quality control of the analytical procedures is essential to report reliable and comparable results. In this study, we performed an interlaboratory comparison at laboratories specialized for PCR and high-throughput-sequencing (HTS)-based WBE analysis. Frozen reserve samples from low COVID-19 incidence periods were spiked with different inactivated authentic SARS-CoV-2 variants in graduated concentrations and ratios. Samples were sent to the participating laboratories for analysis using laboratory specific methods and the reported viral genome copy numbers and the detection of viral variants were compared with the expected values. All PCR-laboratories reported SARS-CoV-2 genome copy equivalents (GCE) for all spiked samples with a mean intra- and inter-laboratory variability of 19 % and 104 %, respectively, largely reproducing the spike-in scheme. PCR-based genotyping was, in dependence of the underlying PCR-assay performance, able to predict the relative amount of variant specific substitutions even in samples with low spike-in amount. The identification of variants by HTS, however, required >100 copies/ml wastewater and had limited predictive value when analyzing at a genome coverage below 60 %. This interlaboratory test demonstrates that despite highly heterogeneous isolation and analysis procedures, overall SARS-CoV-2 GCE and mutations were determined accurately. Hence, decentralized SARS-CoV-2 wastewater monitoring is feasible to generate comparable analysis results. However, since not all assays detected the correct variant, prior evaluation of PCR and sequencing workflows as well as sustained quality control such as interlaboratory comparisons are mandatory for correct variant detection.

12.
Environ Sci Technol ; 46(18): 10073-80, 2012 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-22917471

RESUMO

We present a rapid and effective adsorption-elution method based on monolithic affinity filtration (MAF) for the concentration and purification of waterborne viruses. The MAF column consists of a hydrolyzed macroporous epoxy-based polymer. High recoveries were achieved by columns for the bacterial virus (bacteriophage) MS2 110 (±19)%, as model organism, as well as for human adenoviruses 42.4 (±3.4)% and murine noroviruses 42.6 (±1.9)%. This new concentration and purification method was combined with crossflow ultrafiltration (CUF). Because of the adsorption of the examined viruses to the macroporous surface of the MAF column at pH 3, concentrated matrix components by CUF can be removed. Bacteriophages MS2 were spiked in tap water and concentrated with the new CUF-MAF concentration method by a volumetric factor of 10(4) within 33 min. Furthermore, the detection limit for quantification of bacteriophage MS2 by quantitative reverse transcriptase PCR (qRT-PCR) could be improved from 79.47 to 0.0056 GU mL(-1) by a factor of 1.4 × 10(4). In a first study, we have shown that this method could also be applied for river water containing naturally MS2 and MS2-like phages.


Assuntos
Adenoviridae/isolamento & purificação , Levivirus/isolamento & purificação , Norovirus/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/instrumentação , Rios/microbiologia , Ultrafiltração/instrumentação , Adenoviridae/genética , Animais , Linhagem Celular , Desenho de Equipamento , Humanos , Levivirus/genética , Limite de Detecção , Camundongos , Norovirus/genética , RNA Viral/genética , RNA Viral/isolamento & purificação
13.
Front Chem ; 10: 919442, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35836676

RESUMO

The variety of applied antibiotics in animal and human medicine results in the release, development, and spread of relevant numbers of antibiotic resistance genes (ARGs) in the environment. The majority of ARGs are present in intracellular forms (in bacteria). Neglected aspects are extracellular variants of ARGs (eARGs) and their fragments, which have been detected in surface-water samples and sediments. The stability of eARGs is expected to be low; however, binding to particulate matter is likely to improve their stability and also affect their transport and dissemination behavior. Few studies have investigated DNA particle interactions, mostly via indirect characterization of adduct formation in model systems but not in real environmental matrices. Therefore, our study aims at a novel approach for direct characterization of desoxyribonucleic acid (DNA) particle interactions using both cascade filtration and field-flow fractionation. Cascade filtration with quantitative polymerase chain reaction (qPCR) detection indicated retention of ARGs on filters with much larger pore sizes supporting the hypothesis of ARG-particle interactions. However, artifacts from membrane clogging or DNA-membrane interaction cannot be excluded. Consequently, asymmetric flow field-flow fractionation was investigated as an alternative separation technique with the advantage of particle separation in a thin channel, reducing the risk of artifacts. The key method parameters, membrane composition, molecular weight cut off, and carrier composition, were systematically investigated using a calf-thymus DNA-spiked surface-water sample as a model. The results clearly showed a shift in the elution time of clay particles suggesting the presence of DNA-clay adducts. Multi-element detection by inductively coupled plasma mass spectrometry (ICP-MS) enabled monitoring of clay via the Al, Fe, and Si signals and DNA via the P signal. Matching peak profiles for the new fraction in the fractograms of the ARG and DNA-spiked water sample support adduct formation. Further evidence was provided by a novel post-channel filtration approach for the separation of free DNA from DNA-clay adducts.

14.
Water Res ; 210: 117977, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34968879

RESUMO

In recent months, wastewater-based epidemiology (WBE) has been shown to be an important tool for early detection of SARS-CoV-2 circulation in the population. In this study, a detection methodology for SARS-CoV-2 RNA (wildtype and variants of concern) in wastewater was developed based on the detection of different target genes (E and ORF1ab) by polyethylene glycol (PEG) precipitation and digital droplet PCR. This methodology was used to determine the SARS-CoV-2 concentration and the proportion of N501Y mutation in raw sewage of the wastewater treatment plant of the city of Karlsruhe in south-western Germany over a period of 1 year (June 2020 to July 2021). Comparison of SARS-CoV-2 concentrations with reported COVID-19 cases in the catchment area showed a significant correlation. As the clinical SARS-CoV-2 official case report chain takes time, viral RNA titre trends appeared more than 12 days earlier than clinical data, demonstrating the potential of wastewater-based epidemiology as an early warning system. Parallel PCR analysis using seven primer and probe systems revealed similar gene copy numbers with E, ORF, RdRP2 and NSP9 assays. RdPP1 and NSP3 generally resulted in lower copy numbers, and in particular for N1 there was low correlation with the other assays. The occurrence of the N501Y mutation in the wastewater of Karlsruhe was consistent with the occurrence of the alpha-variant (B.1.1.7) in the corresponding individual clinical tests. In batch experiments SARS-CoV-2 RNA was stable for several days under anaerobic conditions, but the copy numbers decreased rapidly in the presence of dissolved oxygen. Overall, this study shows that wastewater-based epidemiology is a sensitive and robust approach to detect trends in the spread of SARS-CoV-2 at an early stage, contributing to successful pandemic management.


Assuntos
COVID-19 , Águas Residuárias , Biomarcadores , Humanos , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2 , Vigilância Epidemiológica Baseada em Águas Residuárias
15.
Water Res ; 213: 118145, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35151087

RESUMO

Identification and location of contamination sources is crucial for water resource protection - especially in karst aquifers which provide 25% of the world´s population with water but are highly vulnerable to contamination. Transport-based source tracking is proposed and verified here as a complementary approach to microbial and chemical source tracking in karst aquifers for identifying and locating such sources of contamination and for avoiding ambiguities that might arise from using one method alone. The transport distance is inversely modelled from contaminant breakthrough curves (BTC), based on analytical solutions of the 1D two-region non-equilibrium advection dispersion equation using GNU Octave. Besides the BTC, the model requires reliable estimates of transport velocity and input time. The model is shown to be robust, allows scripted based, automated 2D sensitivity analyses (interplay of two parameters), and can be favourable when distributed numerical models are inappropriate due to insufficient data. Sensitivity analyses illustrate that the model is highly sensitive to the input time, the flow velocity, and the fraction of the mobile fluid region. A conclusive verification approach was performed by applying the method to synthetic data, tracer tests, and event-based field data. Transport distances were correctly modelled for a set of artificial tracer tests using a discharge-velocity relationship that could be established for the respective karst catchment. For the first time such an approach was shown to be applicable to estimate the maximum distance to the contamination source for coliform bacteria in karst spring water combined with microbial source tracking. However, prediction intervals for the transport distance can be large even in well-studied karst catchments mainly related to uncertainties in the flow velocity and the input time. Using a maximum transport distance is proposed to account for less permeable, "slower" pathways. In general, transport-based source tracking might be used wherever transport can be described by the 1D two-region non-equilibrium model, e.g. rivers and fractured or porous aquifers.

16.
ACS ES T Water ; 2(12): 2460-2470, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-37552738

RESUMO

In the context of the COVID-19 pandemic, wastewater-based epidemiology (WBE) emerged as a useful tool to account for the prevalence of SARS-CoV-2 infections on a population scale. In this study, we analyzed wastewater samples from three large (>300,000 people served) and four small (<25,000 people served) communities throughout southern Germany from August to December 2021, capturing the fourth infection wave in Germany dominated by the Delta variant (B.1.617.2). As dilution can skew the SARS-CoV-2 biomarker concentrations in wastewater, normalization to wastewater parameters can improve the relationship between SARS-CoV-2 biomarker data and clinical prevalence data. In this study, we investigated the suitability and performance of various normalization parameters. Influent flow data showed strong relationships to precipitation data; accordingly, flow-normalization reacted distinctly to precipitation events. Normalization by surrogate viruses CrAssphage and pepper mild mottle virus showed varying performance for different sampling sites. The best normalization performance was achieved with a mixed fecal indicator calculated from both surrogate viruses. Analyzing the temporal and spatial variation of normalization parameters proved to be useful to explain normalization performance. Overall, our findings indicate that the performance of surrogate viruses, flow, and hydro-chemical data is site-specific. We recommend testing the suitability of normalization parameters individually for specific sewage systems.

17.
Environ Sci Technol ; 45(15): 6491-7, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21678913

RESUMO

This article for the first time demonstrates successful application of electrochemical processes to stimulate sequential reductive/oxidative microbial degradation of perchloroethene (PCE) in mineral medium and in contaminated groundwater. In a flow-through column system, hydrogen generation at the cathode supported reductive dechlorination of PCE to cis-dichloroethene (cDCE), vinyl chloride (VC), and ethene (ETH). Electrolytically generated oxygen at the anode allowed subsequent oxidative degradation of the lower chlorinated metabolites. Aerobic cometabolic degradation of cDCE proved to be the bottleneck for complete metabolite elimination. Total removal of chloroethenes was demonstrated for a PCE load of approximately 1.5 µmol/d. In mineral medium, long-term operation with stainless steel electrodes was demonstrated for more than 300 days. In contaminated groundwater, corrosion of the stainless steel anode occurred, whereas DSA (dimensionally stable anodes) proved to be stable. Precipitation of calcareous deposits was observed at the cathode, resulting in a higher voltage demand and reduced dechlorination activity. With DSA and groundwater from a contaminated site, complete degradation of chloroethenes in groundwater was obtained for two months thus demonstrating the feasibility of the sequential bioelectro-approach for field application.


Assuntos
Técnicas Eletroquímicas/métodos , Etilenos/química , Biodegradação Ambiental , Precipitação Química , Corrosão , Eletricidade , Eletrodos , Halogenação , Minerais/química , Modelos Químicos , Oxirredução , Solo/química , Aço Inoxidável , Abastecimento de Água
18.
Water Sci Technol ; 64(9): 1796-803, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22020471

RESUMO

Degradation of the lower chlorinated ethenes is crucial to the application of natural attenuation or in situ bioremediation on chlorinated ethene contaminated sites. Recently, within mixtures of several chloroethenes as they can occur in contaminated groundwater inhibiting effects on aerobic chloroethene degradation have been shown. The current study demonstrated that metabolic vinyl chloride (VC) degradation by an enrichment culture originating from groundwater was not affected by an equimolar concentration (50 µM) of cis-1,2-dichloroethene (cDCE). Only cDCE concentrations at a ratio of 2.4:1 (initial cDCE to VC concentration) caused minor inhibition of VC degradation. Furthermore, the degradation of VC was not affected by the presence of trans-1,2-dichloroethene (tDCE), 1,1-dichloroethene (1,1-DCE), trichloroethene (TCE), and tetrachloroethene (PCE) in equimolar concentrations (50 µM). Only cDCE and tDCE were cometabolically degraded in small amounts. The VC-degrading culture demonstrated a broad pH tolerance from 5 to 9 with an optimum between 6 and 7. Results also showed that the culture could degrade VC concentrations up to 1,800 µM (110 mg/L).


Assuntos
Bactérias/citologia , Bactérias/metabolismo , Técnicas de Cultura de Células/métodos , Cloreto de Vinil/metabolismo , Aerobiose , Biodegradação Ambiental , Dicloroetilenos/metabolismo , Concentração de Íons de Hidrogênio
19.
J Contam Hydrol ; 243: 103883, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34479119

RESUMO

Natural Attenuation (NA) processes have been demonstrated to reduce pollutant loads at different contaminated groundwater sites world-wide and are increasingly considered in contaminated site management concepts. However, data are mainly available for steady state groundwater flow and stable redox conditions as well as pollutants listed in standard regulatory schemes. In this study, the influence of transient groundwater flow and redox conditions on NA was examined at a former gas works site near the river Rhine in Germany. The investigated 78 pollutants included 40 mono- and polyaromatic hydrocarbons (MAHs, PAHs) and 38 NSO-heterocyclic aromatic hydrocarbons (NSO-HET). In the highly polluted areas, the MAHs benzene, indene and indane, the PAHs naphthalene, acenaphthene, 1- and 2-methylnaphthalene and the NSO-HET 2-methylquinoline, carbazole, benzothiophene, dibenzofuran and benzofuran were predominant. Pollutant concentrations decreased with increasing distance from the sources of contamination. At the plume fringes, the MAHs benzene and indane, the PAH acenaphthene, the NSO-HET carbazole, 5-methylbenzothiophene, 2- and 3-methylbenzofuran and 2-methyldibenzofuran were predominant, indicating low retention and slow intrinsic biodegradation of these compounds. The influence of surface water on groundwater level, pollutant concentrations, and redox conditions in the monitoring wells was observed with a permanently installed groundwater sensor. The temporary availability of oxygen was observed at the plume fringes, resulting in aerobic and ferric iron reducing biodegradation processes. Field and laboratory data were used to set-up a groundwater flow and reactive transport model used for quantification of the field mass transfer rates. In conclusion, the study demonstrates that NA is effective under transient flow and redox conditions. A conceptual model and reactive transport simulation can facilitate the interpretation of pronounced fluctuations of pollutant concentration in monitoring wells. Based on the analysis of 78 pollutants, indane, indene and several NSO-HET like carbazole, benzothiophene and 2-methyldibenzofuran are recommended for monitoring at tar oil polluted sites, besides EPA-PAHs and BTEX.


Assuntos
Água Subterrânea , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Biodegradação Ambiental , Oxirredução , Hidrocarbonetos Policíclicos Aromáticos/análise , Poluentes Químicos da Água/análise
20.
Front Microbiol ; 12: 619495, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34012424

RESUMO

The detection of fecal viral pathogens in water is hampered by their great variety and complex analysis. As traditional bacterial indicators are poor viral indicators, there is a need for alternative methods, such as the use of somatic coliphages, which have been included in water safety regulations in recent years. Some researchers have also recommended the use of reference viral pathogens such as noroviruses or other enteric viruses to improve the prediction of fecal viral pollution of human origin. In this work, phages previously tested in microbial source tracking studies were compared with norovirus and adenovirus for their suitability as indicators of human fecal viruses. The phages, namely those infecting human-associated Bacteroides thetaiotaomicron strain GA17 (GA17PH) and porcine-associated Bacteroides strain PG76 (PGPH), and the human-associated crAssphage marker (crAssPH), were evaluated in sewage samples and fecal mixtures obtained from different animals in five European countries, along with norovirus GI + GII (NoV) and human adenovirus (HAdV). GA17PH had an overall sensitivity of ≥83% and the highest specificity (>88%) for human pollution source detection. crAssPH showed the highest sensitivity (100%) and specificity (100%) in northern European countries but a much lower specificity in Spain and Portugal (10 and 30%, respectively), being detected in animal wastewater samples with a high concentration of fecal indicators. The correlations between GA17PH, crAssPH, or the sum of both (BACPH) and HAdV or NoV were higher than between the two human viruses, indicating that bacteriophages are feasible indicators of human viral pathogens of fecal origin and constitute a promising, easy to use and affordable alternative to human viruses for routine water safety monitoring.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA