Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
N Engl J Med ; 386(2): 128-137, 2022 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-34735046

RESUMO

BACKGROUND: Patients with three-vessel coronary artery disease have been found to have better outcomes with coronary-artery bypass grafting (CABG) than with percutaneous coronary intervention (PCI), but studies in which PCI is guided by measurement of fractional flow reserve (FFR) have been lacking. METHODS: In this multicenter, international, noninferiority trial, patients with three-vessel coronary artery disease were randomly assigned to undergo CABG or FFR-guided PCI with current-generation zotarolimus-eluting stents. The primary end point was the occurrence within 1 year of a major adverse cardiac or cerebrovascular event, defined as death from any cause, myocardial infarction, stroke, or repeat revascularization. Noninferiority of FFR-guided PCI to CABG was prespecified as an upper boundary of less than 1.65 for the 95% confidence interval of the hazard ratio. Secondary end points included a composite of death, myocardial infarction, or stroke; safety was also assessed. RESULTS: A total of 1500 patients underwent randomization at 48 centers. Patients assigned to undergo PCI received a mean (±SD) of 3.7±1.9 stents, and those assigned to undergo CABG received 3.4±1.0 distal anastomoses. The 1-year incidence of the composite primary end point was 10.6% among patients randomly assigned to undergo FFR-guided PCI and 6.9% among those assigned to undergo CABG (hazard ratio, 1.5; 95% confidence interval [CI], 1.1 to 2.2), findings that were not consistent with noninferiority of FFR-guided PCI (P = 0.35 for noninferiority). The incidence of death, myocardial infarction, or stroke was 7.3% in the FFR-guided PCI group and 5.2% in the CABG group (hazard ratio, 1.4; 95% CI, 0.9 to 2.1). The incidences of major bleeding, arrhythmia, and acute kidney injury were higher in the CABG group than in the FFR-guided PCI group. CONCLUSIONS: In patients with three-vessel coronary artery disease, FFR-guided PCI was not found to be noninferior to CABG with respect to the incidence of a composite of death, myocardial infarction, stroke, or repeat revascularization at 1 year. (Funded by Medtronic and Abbott Vascular; FAME 3 ClinicalTrials.gov number, NCT02100722.).


Assuntos
Ponte de Artéria Coronária , Estenose Coronária/cirurgia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea/métodos , Idoso , Doenças Cardiovasculares/epidemiologia , Ponte de Artéria Coronária/efeitos adversos , Estenose Coronária/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Reoperação , Stents
2.
Circulation ; 148(12): 950-958, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37602376

RESUMO

BACKGROUND: Previous studies comparing percutaneous coronary intervention (PCI) with coronary artery bypass grafting (CABG) in patients with multivessel coronary disease not involving the left main have shown significantly lower rates of death, myocardial infarction (MI), or stroke after CABG. These studies did not routinely use current-generation drug-eluting stents or fractional flow reserve (FFR) to guide PCI. METHODS: FAME 3 (Fractional Flow Reserve versus Angiography for Multivessel Evaluation) is an investigator-initiated, multicenter, international, randomized trial involving patients with 3-vessel coronary artery disease (not involving the left main coronary artery) in 48 centers worldwide. Patients were randomly assigned to receive FFR-guided PCI using zotarolimus drug-eluting stents or CABG. The prespecified key secondary end point of the trial reported here is the 3-year incidence of the composite of death, MI, or stroke. RESULTS: A total of 1500 patients were randomized to FFR-guided PCI or CABG. Follow-up was achieved in >96% of patients in both groups. There was no difference in the incidence of the composite of death, MI, or stroke after FFR-guided PCI compared with CABG (12.0% versus 9.2%; hazard ratio [HR], 1.3 [95% CI, 0.98-1.83]; P=0.07). The rates of death (4.1% versus 3.9%; HR, 1.0 [95% CI, 0.6-1.7]; P=0.88) and stroke (1.6% versus 2.0%; HR, 0.8 [95% CI, 0.4-1.7]; P=0.56) were not different. MI occurred more frequently after PCI (7.0% versus 4.2%; HR, 1.7 [95% CI, 1.1-2.7]; P=0.02). CONCLUSIONS: At 3-year follow-up, there was no difference in the incidence of the composite of death, MI, or stroke after FFR-guided PCI with current-generation drug-eluting stents compared with CABG. There was a higher incidence of MI after PCI compared with CABG, with no difference in death or stroke. These results provide contemporary data to allow improved shared decision-making between physicians and patients with 3-vessel coronary artery disease. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02100722.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Humanos , Doença da Artéria Coronariana/cirurgia , Seguimentos , Intervenção Coronária Percutânea/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
3.
N Engl J Med ; 385(18): 1643-1655, 2021 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-34449185

RESUMO

BACKGROUND: The appropriate duration of dual antiplatelet therapy in patients at high risk for bleeding after the implantation of a drug-eluting coronary stent remains unclear. METHODS: One month after they had undergone implantation of a biodegradable-polymer sirolimus-eluting coronary stent, we randomly assigned patients at high bleeding risk to discontinue dual antiplatelet therapy immediately (abbreviated therapy) or to continue it for at least 2 additional months (standard therapy). The three ranked primary outcomes were net adverse clinical events (a composite of death from any cause, myocardial infarction, stroke, or major bleeding), major adverse cardiac or cerebral events (a composite of death from any cause, myocardial infarction, or stroke), and major or clinically relevant nonmajor bleeding; cumulative incidences were assessed at 335 days. The first two outcomes were assessed for noninferiority in the per-protocol population, and the third outcome for superiority in the intention-to-treat population. RESULTS: Among the 4434 patients in the per-protocol population, net adverse clinical events occurred in 165 patients (7.5%) in the abbreviated-therapy group and in 172 (7.7%) in the standard-therapy group (difference, -0.23 percentage points; 95% confidence interval [CI], -1.80 to 1.33; P<0.001 for noninferiority). A total of 133 patients (6.1%) in the abbreviated-therapy group and 132 patients (5.9%) in the standard-therapy group had a major adverse cardiac or cerebral event (difference, 0.11 percentage points; 95% CI, -1.29 to 1.51; P = 0.001 for noninferiority). Among the 4579 patients in the intention-to-treat population, major or clinically relevant nonmajor bleeding occurred in 148 patients (6.5%) in the abbreviated-therapy group and in 211 (9.4%) in the standard-therapy group (difference, -2.82 percentage points; 95% CI, -4.40 to -1.24; P<0.001 for superiority). CONCLUSIONS: One month of dual antiplatelet therapy was noninferior to the continuation of therapy for at least 2 additional months with regard to the occurrence of net adverse clinical events and major adverse cardiac or cerebral events; abbreviated therapy also resulted in a lower incidence of major or clinically relevant nonmajor bleeding. (Funded by Terumo; MASTER DAPT ClinicalTrials.gov number, NCT03023020.).


Assuntos
Síndrome Coronariana Aguda/terapia , Hemorragia/induzido quimicamente , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/administração & dosagem , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/mortalidade , Idoso , Doenças Cardiovasculares/mortalidade , Quimioterapia Combinada , Stents Farmacológicos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Infarto do Miocárdio/etiologia , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Trombose/prevenção & controle
4.
Artigo em Inglês | MEDLINE | ID: mdl-38895766

RESUMO

BACKGROUND: In 5%-25% of non-ST-elevation acute coronary syndrome (NSTE-ACS) patients, coronary angiography reveals no obstructive coronary arteries (MINOCA). Coronary microvascular disease (CMD) is a potential causal pathophysiological mechanism in these patients and can be diagnosed by continuous thermodilution assessment. Recently, the microvascular resistance reserve (MRR) has been introduced as a novel index to assess the vasodilatory capacity of the microcirculation. However, continuous thermodilution and MRR have never been investigated in the acute setting in MINOCA patients and invasive assessment of the microcirculation in these patients are currently lacking. AIMS: The objectives of the study were to investigate the incidence of CMD (MRR ≤ 2.7) in patients with MINOCA and to evaluate the feasibility and safety of continuous thermodilution-based assessment during index coronary angiography in the acute setting. METHODS: This study was a prospective, observational, pilot study investigating coronary physiology in the acute setting in MINOCA patients. Patients admitted with a diagnosis of NSTE-ACS were eligible for inclusion. RESULTS: In total, 19 MINOCA patients were included in this analysis; the mean age was 70 ± 9 years, and 79% were females. CMD was present in 6 patients (32%). Qrest was significantly higher in the MRR ≤ 2.7 group compared to the MRR > 2.7 group (0.076 [0.057-0.100] vs. 0.049 [0.044-0.071] L/min, p = 0.03). Rµ,rest was significantly lower in the MRR ≤ 2.7 group compared to the MRR > 2.7 group (1083 [710-1510] vs. 1563 [1298-1970] WU, p = 0.04). No periprocedural complications or hemodynamic instability have occurred during continuous thermodilution assessment during the index coronary angiography. CONCLUSION: In patients admitted for MINOCA undergoing immediate coronary angiography, continuous thermodilution assessment and MRR are feasible and safe in the acute setting, and evidence of functional CMD could be observed in one-third of the MINOCA patients.

5.
Cost Eff Resour Alloc ; 22(1): 24, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38528520

RESUMO

BACKGROUND: There is growing evidence to support the benefits of transcatheter aortic valve implantation (TAVI) over surgical aortic valve replacement (SAVR) in patients with symptomatic severe aortic stenosis (sSAS) who are at high- or intermediate-risk of surgical mortality. The PARTNER 3 trial showed clinical benefits with SAPIEN 3 TAVI compared with SAVR in patients at low risk of surgical mortality. Whether TAVI is also cost-effective compared with SAVR for low-risk patients in the Dutch healthcare system remains uncertain. This article presents an analysis using PARTNER 3 outcomes and costs data from the Netherlands to inform a cost-utility model and examine cost implications of TAVI over SAVR in a Dutch low-risk population. METHODS: A two-stage cost-utility analysis was performed using a published and validated health economic model based on adverse events with both TAVI and SAVR interventions from a published randomized low risk trial dataset, and a Markov model that captured lifetime healthcare costs and patient outcomes post-intervention. The model was adapted using Netherlands-specific cost data to assess the cost-effectiveness of TAVI and SAVR. Uncertainty was addressed using deterministic and probabilistic sensitivity analyses. RESULTS: TAVI generated 0.89 additional quality-adjusted life years (QALYs) at a €4742 increase in costs per patient compared with SAVR over a lifetime time horizon, representing an incremental cost-effectiveness ratio (ICER) of €5346 per QALY gained. Sensitivity analyses confirm robust results, with TAVI remaining cost-effective across several sensitivity analyses. CONCLUSIONS: Based on the model results, compared with SAVR, TAVI with SAPIEN 3 appears cost-effective for the treatment of Dutch patients with sSAS who are at low risk of surgical mortality. Qualitative data suggest broader societal benefits are likely and these findings could be used to optimize appropriate intervention selection for this patient population.

6.
Neth Heart J ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653922

RESUMO

BACKGROUND: During transcatheter aortic valve implantation (TAVI), secondary access is required for angiographic guidance and temporary pacing. The most commonly used secondary access sites are the femoral artery (angiographic guidance) and the femoral vein (temporary pacing). An upper extremity approach using the radial artery and an upper arm vein instead of the lower extremity approach using the femoral artery and femoral vein may reduce clinically relevant secondary access site-related bleeding complications, but robust evidence is lacking. TRIAL DESIGN: The TAVI XS trial is a multicentre, randomised, open-label clinical trial with blinded evaluation of endpoints. A total of 238 patients undergoing transfemoral TAVI will be included. The primary endpoint is the incidence of clinically relevant bleeding (i.e. Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding) of the randomised secondary access site (either diagnostic or pacemaker access, or both) within 30 days after TAVI. Secondary endpoints include time to mobilisation after TAVI, duration of hospitalisation, any BARC type 2, 3 or 5 bleeding, and early safety at 30 days according to Valve Academic Research Consortium­3 criteria. CONCLUSION: The TAVI XS trial is the first randomised trial comparing an upper extremity approach to a lower extremity approach with regard to clinically relevant secondary access site-related bleeding complications. The results of this trial will provide important insights into the safety and efficacy of an upper extremity approach in patients undergoing transfemoral TAVI.

7.
Am J Physiol Heart Circ Physiol ; 325(3): H562-H568, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37477689

RESUMO

When measuring hyperemic and nonhyperemic pressure ratios with traditional sensor-tipped wires, the inevitable hydrostatic pressure gradient (HPG) may influence treatment decisions. This study aimed to simulate and analyze the effect of a hydrostatic pressure gradient on different indices of functional lesion severity. A hypothetical Pd-Pa height difference and subsequent hydrostatic pressure gradient based on previous literature was applied to the pressure measurements from the CONTRAST study. The effect on three indices of functional lesion severity (FFR, Pd/Pa, and dPR) was assessed and possible reclassifications in functional significance by the different indices were analyzed. In 602 pressure tracings, simulated hydrostatic pressure gradients led to an absolute change in Pd of 3.18 ± 1.30 mmHg, resulting in an overall increase in FFR, Pd/Pa, and dPR of 0.02 ± 0.04 for all indices (P = 0.69). Reclassification due to the hydrostatic pressure gradient when using dichotomous cutoff values occurred in 13.4, 22.3, and 20.6% for FFR, Pd/Pa, and dPR, respectively. The effect of hydrostatic pressure gradient correction differed among the coronary arteries and was most pronounced in the left anterior descending. When considering the gray zone for the different functional indices, the hydrostatic pressure gradient resulted in reclassification in only one patient out of the complete patient population (1/602; 0.17%). The hydrostatic pressure gradient can influence functional lesion assessment when using dichotomous cutoff values. When taking the gray zone into account, its effect is limited.NEW & NOTEWORTHY This study systematically simulated the effect of hydrostatic pressure gradients (HPG) on real-world hyperemic and nonhyperemic pressure ratios, showing correction for HPG leads to reclassification in functional significance from 13.4 to 22.3% for different functional indices. This was most pronounced in nonhyperemic pressure ratios. A new pressure guidewire (Wirecath) is unaffected by HPG. The ongoing PW-COMPARE study (NCT04802681) prospectively analyzes the magnitude and importance of HPG by simultaneous FFR measurements.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Humanos , Cateterismo Cardíaco/métodos , Angiografia Coronária/métodos , Vasos Coronários , Pressão Hidrostática , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Estudos Clínicos como Assunto
8.
Am Heart J ; 266: 168-175, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37806333

RESUMO

The optimal treatment strategy for coronary bifurcation lesions by percutaneous coronary intervention (PCI) is complex and remains a subject of debate. Current guidelines advise a stepwise provisional approach with optional two-stent strategy. However, a two-stent strategy, both upfront and stepwise provisional, is technically demanding. Therefore, there is increasing interest in the use of drug-eluting balloons (DEB) in bifurcation lesions, mainly after a provisional approach with unsatisfactory result of the side branch. Some small pilot studies already showed that the use of DEB in bifurcation lesions is safe and feasible. However, a randomized comparison of this hybrid DEB strategy with a two-stent strategy is currently lacking. TRIAL DESIGN: The Hybrid DEB study is a prospective, multicenter, randomized controlled trial investigating noninferiority of a hybrid DEB approach, using a combination of a drug-eluting stent (DES) in the main vessel and DEB in the side branch, compared to stepwise provisional two-stent strategy in patients with true bifurcation lesions. A total of 500 patients with de novo true coronary bifurcation lesions, treated with a stepwise provisional approach and an unsatisfactory result of the side branch after main vessel stenting (≥ 70% stenosis and/or < thrombolysis in myocardial infarction III flow), will be randomized in a 1:1 ratio to receive either treatment with a DEB or with a DES in the side branch. The primary endpoint is a composite endpoint of the occurrence of all-cause death, periprocedural or spontaneous myocardial infarction and/or target vessel revascularization at the anticipated median 2-year follow-up. CONCLUSION: The Hybrid DEB study will compare in a multicenter, randomized fashion a hybrid DEB approach with a stepwise provisional two-stent strategy in patients with true bifurcation lesions. TRIAL REGISTRATION: ClinicalTrials.gov no. NCT05731687.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Stents Farmacológicos/efeitos adversos , Angioplastia Coronária com Balão/efeitos adversos , Estudos Prospectivos , Angiografia Coronária/efeitos adversos , Stents/efeitos adversos , Infarto do Miocárdio/etiologia , Resultado do Tratamento , Doença da Artéria Coronariana/complicações
9.
Neth Heart J ; 31(12): 479-488, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37917382

RESUMO

OBJECTIVE: The aim of this study was to evaluate the reasons for emergent cardiac surgery (ECS) after transcatheter aortic valve implantation (TAVI) and assess outcomes of these patients. METHODS: All patients undergoing ECS following a complicated TAVI procedure at a high-volume TAVI centre in the Netherlands from 1 January 2008 to 1 April 2022 were included. Baseline and procedural characteristics and outcome data (procedural, 30-day and 1­year mortality, in-hospital stroke, 30-day pacemaker implantation, 30-day vascular complications, 30-day deep sternal wound infections and 30-day re-exploration) were collected from patient files and analysed using descriptive statistics. RESULTS: During the study period, 16 of 1594 patients (1.0%) undergoing TAVI required ECS. The main reason for ECS was valve embolisation (n = 9; 56.3%), followed by perforation of the left/right ventricle with guide wire/pacemaker lead (n = 3; 18.8%) and annular rupture (n = 3; 18.8%). Procedural, 30-day and 1­year mortality was 0%, 18.8% (n = 3) and 31.3% (n = 5), respectively. In-hospital stroke occurred in 1 patient (6.3%), a pacemaker was implanted at 30 days in 2 patients (12.5%), and major vascular complications did not occur. CONCLUSION: ECS following complicated TAVI was performed in only a small number of cases. It had a high but acceptable perioperative and 30-day mortality, taking into account the otherwise lethal consequences. In case of valve embolisation, no periprocedural or 30-day mortality was observed for surgical aortic valve replacement (even in a redo setting), which supported the necessity to perform TAVI in centres with cardiac surgical backup on site.

10.
Neth Heart J ; 31(12): 473-478, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37843746

RESUMO

INTRODUCTION: Based on European guidelines, transcatheter aortic valve implementation (TAVI) could be the therapy of choice in patients with severe aortic stenosis aged ≥ 75 years. In the Netherlands, there has been a debate between healthcare providers and the National Health Care Institute regarding reimbursement for TAVI, which resulted in an indication document that defines TAVI patients who are eligible for reimbursement. This document has been effective since 1 January 2021. METHODS: We extracted data from the Netherlands Heart Registry for patients who underwent biological surgical aortic valve replacement (SAVR) or TAVI in the Netherlands from 2018 through 2021. We compared baseline characteristics and variables from the indication document for the subsequent years and age groups. We also analysed the annual SAVR/TAVI ratio. RESULTS: The total number of patients treated with SAVR or TAVI was constant in 2018-2021. Baseline characteristics of patients treated with TAVI did not differ throughout the years. The SAVR/TAVI ratio shifted towards a higher percentage of TAVI from 2018 to 2019. From 2019 to 2020, the TAVI percentage was constant. Since the implementation of the indication document (in 2021), a change in the SAVR/TAVI ratio was not found either. CONCLUSION: Since the implementation of the national indication document for AVR in 2021, no major effect was seen for the SAVR versus TAVI landscape in the Netherlands.

11.
Neth Heart J ; 31(12): 489-499, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37910336

RESUMO

OBJECTIVE: The importance of revascularisation of significant coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is unclear. Despite the lack of randomised controlled trials comparing different revascularisation strategies, guidelines currently recommend percutaneous coronary intervention (PCI) in patients with significant proximal CAD undergoing TAVI. METHODS: In this systematic review and meta-analysis, a systematic search was conducted to identify studies comparing TAVI with and without PCI in patients with significant CAD on pre-TAVI coronary angiography. Endpoints were all-cause mortality, cardiac death, stroke, myocardial infarction and major bleeding. RESULTS: In total, 14 studies were included, involving 3838 patients, of whom 1806 (47%) underwent PCI before TAVI. All-cause mortality did not differ significantly between TAVI with and without preceding PCI at 30 days, 1 year and > 1 year. There were no significant differences in risk of cardiac death, stroke or myocardial infarction between the groups. However, TAVI performed with PCI resulted in a higher risk of major bleeding within 30 days after TAVI (odds ratio: 0.66; 95% confidence interval: 0.46-0.94). CONCLUSION: This systematic review and meta-analysis showed no significant differences in clinical outcomes between patients with concomitant significant CAD who were treated with TAVI with and without preceding PCI at both short- and long-term follow-up. However, there was a higher risk of major bleeding at 30 days in patients undergoing TAVI with preceding PCI. In the context of serious risk of bias in the included studies, results of randomised controlled trials are warranted.

12.
Circulation ; 144(15): 1196-1211, 2021 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-34455849

RESUMO

BACKGROUND: The optimal duration of antiplatelet therapy (APT) in patients at high bleeding risk with or without oral anticoagulation (OAC) after coronary stenting remains unclear. METHODS: In the investigator-initiated, randomize, open-label MASTER DAPT trial (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Standard DAPT Regimen), 4579 patients at high bleeding risk were randomized after 1-month dual APT to abbreviated or nonabbreviated APT strategies. Randomization was stratified by concomitant OAC indication. In this subgroup analysis, we report outcomes of populations with or without an OAC indication. In the population with an OAC indication, patients changed immediately to single APT for 5 months (abbreviated regimen) or continued ≥2 months of dual APT and single APT thereafter (nonabbreviated regimen). Patients without an OAC indication changed to single APT for 11 months (abbreviated regimen) or continued ≥5 months of dual APT and single APT thereafter (nonabbreviated regimen). Coprimary outcomes at 335 days after randomization were net adverse clinical outcomes (composite of all-cause death, myocardial infarction, stroke, and Bleeding Academic Research Consortium 3 or 5 bleeding events); major adverse cardiac and cerebral events (all-cause death, myocardial infarction, and stroke); and type 2, 3, or 5 Bleeding Academic Research Consortium bleeding. RESULTS: Net adverse clinical outcomes or major adverse cardiac and cerebral events did not differ with abbreviated versus nonabbreviated APT regimens in patients with OAC indication (n=1666; hazard ratio [HR], 0.83 [95% CI, 0.60-1.15]; and HR, 0.88 [95% CI, 0.60-1.30], respectively) or without OAC indication (n=2913; HR, 1.01 [95% CI, 0.77-1.33]; or HR, 1.06 [95% CI, 0.79-1.44]; Pinteraction=0.35 and 0.45, respectively). Bleeding Academic Research Consortium 2, 3, or 5 bleeding did not significantly differ in patients with OAC indication (HR, 0.83 [95% CI, 0.62-1.12]) but was lower with abbreviated APT in patients without OAC indication (HR, 0.55 [95% CI, 0.41-0.74]; Pinteraction=0.057). The difference in bleeding in patients without OAC indication was driven mainly by a reduction in Bleeding Academic Research Consortium 2 bleedings (HR, 0.48 [95% CI, 0.33-0.69]; Pinteraction=0.021). CONCLUSIONS: Rates of net adverse clinical outcomes and major adverse cardiac and cerebral events did not differ with abbreviated APT in patients with high bleeding risk with or without an OAC indication and resulted in lower bleeding rates in patients without an OAC indication. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03023020.


Assuntos
Anticoagulantes/uso terapêutico , Hemorragia/tratamento farmacológico , Inibidores da Agregação Plaquetária/uso terapêutico , Stents/normas , Administração Oral , Idoso , Anticoagulantes/farmacologia , Feminino , Humanos , Masculino , Inibidores da Agregação Plaquetária/farmacologia , Fatores de Risco
13.
Catheter Cardiovasc Interv ; 100(3): 378-386, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35819134

RESUMO

OBJECTIVES: To identify angiographic predictors of aberrant left circumflex artery (LCx) by comparing left main (LM) length and bifurcation angle between patients with aberrant LCx and normal anatomy. BACKGROUND: Failure to recognize aberrant LCx during a cardiac catheterization may hamper correct diagnosis, delay intervention in acute coronary syndromes, and result in increased contrast volume, radiation exposure, and infarct size. METHODS: We retrospectively analyzed angiograms of aberrant LCx patients and normal anatomy matched controls, in three-participating centers. LM-length, bifurcation angle between the left anterior descending (LAD) and the first non-LAD branch of the LM, and procedural data were compared. RESULTS: Between 2003 and 2020, 136 patients with aberrant LCx and 135 controls were identified. More catheters (2.4 ± 0.6 vs. 2.2 ± 0.9, p = 0.009), larger contrast volumes (169 ± 94 ml vs. 129 ± 68 ml, p < 0.0005), and prolonged fluoroscopy time (652.9 ± 623.7 s vs. 393.1 ± 332.1 s, p < 0.0005), were required in the aberrant LCx-group compared with controls. Patients with aberrant LCx had a longer LM-length and a more acute bifurcation angle, both in caudal and cranial views, compared with controls (24.7 ± 8.1 vs. 10.8 ± 4.5 mm, p < 0.0005 and 26.7 ± 7.4 vs. 12 ± 5.5 mm, p < 0.0005, respectively, and 45.2° ± 12° vs. 88.8° ± 23°, p < 0.0005 and 51.9° ± 21° vs. 68.2° ± 28.3°, p < 0.0005, respectively). In ROC analysis, LM-length showed the best diagnostic accuracy for detecting aberrant LCx. In multiple logistic regression analysis, a cranially measured LM-length > 17.7 mm was associated with a 5.3 times greater probability of predicting aberrant LCx [95% CI (3.4-8.1), p < 0.0001]. CONCLUSIONS: Our study suggests that a long LM-length and an acute bifurcation angle can indicate the presence of aberrant LCx. We present a practical algorithm for its rapid identification.


Assuntos
Doença da Artéria Coronariana , Malformações Vasculares , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Resultado do Tratamento
14.
N Engl J Med ; 379(3): 250-259, 2018 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-29785878

RESUMO

BACKGROUND: We hypothesized that fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) would be superior to medical therapy as initial treatment in patients with stable coronary artery disease. METHODS: Among 1220 patients with angiographically significant stenoses, those in whom at least one stenosis was hemodynamically significant (FFR, ≤0.80) were randomly assigned to FFR-guided PCI plus medical therapy or to medical therapy alone. Patients in whom all stenoses had an FFR of more than 0.80 received medical therapy and were entered into a registry. The primary end point was a composite of death, myocardial infarction, or urgent revascularization. RESULTS: A total of 888 patients underwent randomization (447 patients in the PCI group and 441 in the medical-therapy group). At 5 years, the rate of the primary end point was lower in the PCI group than in the medical-therapy group (13.9% vs. 27.0%; hazard ratio, 0.46; 95% confidence interval [CI], 0.34 to 0.63; P<0.001). The difference was driven by urgent revascularizations, which occurred in 6.3% of the patients in the PCI group as compared with 21.1% of those in the medical-therapy group (hazard ratio, 0.27; 95% CI, 0.18 to 0.41). There were no significant differences between the PCI group and the medical-therapy group in the rates of death (5.1% and 5.2%, respectively; hazard ratio, 0.98; 95% CI, 0.55 to 1.75) or myocardial infarction (8.1% and 12.0%; hazard ratio, 0.66; 95% CI, 0.43 to 1.00). There was no significant difference in the rate of the primary end point between the PCI group and the registry cohort (13.9% and 15.7%, respectively; hazard ratio, 0.88; 95% CI, 0.55 to 1.39). Relief from angina was more pronounced after PCI than after medical therapy. CONCLUSIONS: In patients with stable coronary artery disease, an initial FFR-guided PCI strategy was associated with a significantly lower rate of the primary composite end point of death, myocardial infarction, or urgent revascularization at 5 years than medical therapy alone. Patients without hemodynamically significant stenoses had a favorable long-term outcome with medical therapy alone. (Funded by St. Jude Medical and others; FAME 2 ClinicalTrials.gov number, NCT01132495 .).


Assuntos
Estenose Coronária/tratamento farmacológico , Estenose Coronária/terapia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Angina Pectoris/terapia , Anti-Hipertensivos/uso terapêutico , Doença das Coronárias/tratamento farmacológico , Doença das Coronárias/mortalidade , Doença das Coronárias/terapia , Estenose Coronária/fisiopatologia , Stents Farmacológicos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/prevenção & controle , Inibidores da Agregação Plaquetária/uso terapêutico , Retratamento/estatística & dados numéricos
15.
Catheter Cardiovasc Interv ; 98(6): 1204-1209, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34137483

RESUMO

OBJECTIVES: We aimed to determine the safety and efficacy of the Allegra transcatheter heart valve (THV) for the treatment of severe aortic valve stenosis in a large patient population treated under real-world conditions. BACKGROUND: The Allegra is a novel self-expanding THV with supra-annular bovine leaflets. The valve is available in three different sizes (23, 27, and 31 mm), all are delivered through an 18F sheath. METHODS: Consecutive patients undergoing TAVR with the Allegra THV were enrolled in a multicenter-registry. Data were collected throughout initial hospital-stay and at 30-day follow-up. Clinical endpoints were defined according to the updated definitions of the Valve-Academic-Research-Consortium. RESULTS: This registry included 255 patients (mean age 83 ± 6 years, 48% women) from four European centers. Median European System for Cardiac Operative Risk Evaluation II score (EuroSCORE II) was 3.3% (IQR 1.9-5.8%). Acute device success was 95.7%. The remaining 11 patients had either moderate paravalvular regurgitation immediately after the procedure (7 patients) or the device could not be optimal positioned requiring implantation of a second THV (4 patients). Major vascular complications and major/life-threatening bleedings occurred in 10 (3.9%) and 12 (4.7%) patients, respectively. At 30 day follow-up, mean effective orifice area was 2.2 ± 0.5 cm2 , mean gradient was 6.9 ± 3.8 mmHg, 7 (3.3%) patients had more than mild paravalvular leakage, 3 patients (1.2%) had died, 6 patients (2.4%) had a stroke and 30 (12.8%) patients had required implantation of a new permanent pacemaker. CONCLUSIONS: Transfemoral implantation of the Allegra THV resulted in favorable clinical and echocardiographic outcomes during hospitalization and short-term follow up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bovinos , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Terfenadina/análogos & derivados , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 97(6): 1270-1278, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33347739

RESUMO

OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug-based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.


Assuntos
Aneurisma da Aorta Abdominal , Estenose da Valva Aórtica , Implante de Prótese Vascular , Cateterismo Periférico , Procedimentos Endovasculares , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Sistema de Registros , Resultado do Tratamento
17.
Lancet ; 393(10175): 987-997, 2019 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-30827782

RESUMO

BACKGROUND: Supraflex is a sirolimus-eluting stent with a biodegradable polymer coating and ultra-thin struts. We aimed to compare Supraflex with the standard of care, Xience, an everolimus-eluting stent with a durable polymer coating, regarding clinical outcomes with a randomised trial in an all-comer population. METHODS: We did a prospective, randomised, single-blind, multicentre study (TALENT) across 23 centres in Europe (the Netherlands, Poland, the UK, Spain, Bulgaria, Hungary, and Italy). Eligible participants were aged 18 years or older, had one or more coronary artery stenosis of 50% or greater in a native coronary artery, saphenous venous graft, or arterial bypass conduit, and had a reference vessel diameter of 2·25-4·50 mm. Patients underwent percutaneous coronary intervention in an all-comer manner. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting stent with a biodegradable polymer coating and ultra-thin struts (Supraflex) or an everolimus-eluting stent with a durable polymer coating (Xience). Randomisation was done by local investigators by use of a web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between groups at 12 months after the procedure, assessed in an intention-to-treat population. On assumption of 1-year composite endpoint prevalence of 8·3%, a margin of 4·0% was defined for non-inferiority of the Supraflex group compared with the Xience group. This trial is registered with ClinicalTrials.gov, number NCT02870140. FINDINGS: Between Oct 21, 2016, and July 3, 2017, 1435 patients with 1046 lesions were randomly assigned to Supraflex, of whom 720 received the index procedure, and 715 patients with 1030 lesions were assigned to Xience, all receiving the index procedure. At 12 months, the primary endpoint had occurred in 35 patients (4·9 %) in the Supraflex group and in 37 patients (5·3%) in the Xience group (absolute difference -0·3% [one-sided 95% upper confidence bound 1·6%], pnon-inferiority<0·0001). Definite or probable stent thrombosis prevalence, a safety indicator, was low in both groups and did not differ between them. INTERPRETATION: The Supraflex stent was non-inferior to the Xience stent for a device-oriented composite clinical endpoint at 12 months in an all-comer population. Supraflex seems a safe and effective alternative drug-eluting stent to other stents in clinical practice. FUNDING: European Cardiovascular Research Institute.


Assuntos
Aterosclerose/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Imunossupressores/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Stents Farmacológicos/efeitos adversos , Determinação de Ponto Final , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Método Simples-Cego , Trombose/etiologia
18.
Catheter Cardiovasc Interv ; 95(1): 128-135, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31020797

RESUMO

OBJECTIVES: This study aimed to prospectively investigate intra-aortic balloon pump counterpulsation (IABP) support in large myocardial infarction complicated by persistent ischemia after primary percutaneous coronary intervention (PCI). BACKGROUND: Use of IABP is suggested to be effective by increasing diastolic aortic pressure, thereby improving coronary blood flow. This can only be expected with exhausted coronary autoregulation, typical in acute myocardial infarction complicated by persistent ischemia. In this situation, augmented diastolic pressure is expected to increase myocardial oxygenation. METHODS: One hundred patients with large STEMI complicated by persistent ischemia after primary PCI were randomized to treatment with or without IABP therapy on top of standard care. IABP support was initiated following primary PCI, immediately after inclusion. Primary end point was all-cause mortality, need for (additional) mechanical hemodynamic support, or readmission for heart failure within 6 months. RESULTS: Mean age was 63 ± 10 years, 76% were male. Mean systolic and diastolic blood pressure were 120 ± 25 mmHg and 73 ± 17 mmHg. Mean heart rate was 75 ± 18 mmHg. Before PCI, mean summed ST-deviation was 21 ± 8 mm with only minimal ST-resolution after PCI. One patient in the IABP group reached the primary end point versus four patients in the control group (2% vs. 8%; p = 0.16). After primary PCI, resolution of ST-deviation was significantly more pronounced in the IABP group (73 ± 17%) compared to the control group (56 ± 26%; p < 0.01). CONCLUSIONS: In this pilot study, in patients with large STEMI and persistent ischemia after primary PCI, use of IABP showed a nonsignificant decrease in mortality, necessity for (additional) mechanical hemodynamic support or readmission for heart failure at 6 months, and resulted in more rapid ST-resolution.


Assuntos
Circulação Coronária , Hemodinâmica , Balão Intra-Aórtico , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Idoso , Causas de Morte , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/mortalidade , Masculino , Pessoa de Meia-Idade , Países Baixos , Readmissão do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Projetos Piloto , Estudos Prospectivos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
19.
J Interv Cardiol ; 2020: 4603169, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32774184

RESUMO

With the increasing prevalence of aortic stenosis (AS) due to a growing elderly population, a proper understanding of its physiology is paramount to guide therapy and define severity. A better understanding of the microvasculature in AS could improve clinical care by predicting left ventricular remodeling or anticipate the interplay between epicardial stenosis and myocardial dysfunction. In this review, we combine five decades of literature regarding microvascular, coronary, and aortic valve physiology with emerging insights from newly developed invasive tools for quantifying microcirculatory function. Furthermore, we describe the coupling between microcirculation and epicardial stenosis, which is currently under investigation in several randomized trials enrolling subjects with concomitant AS and coronary disease. To clarify the physiology explained previously, we present two instructive cases with invasive pressure measurements quantifying coexisting valve and coronary stenoses. Finally, we pose open clinical and research questions whose answers would further expand our knowledge of microvascular dysfunction in AS. These trials were registered with NCT03042104, NCT03094143, and NCT02436655.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Circulação Coronária , Microcirculação/fisiologia , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/terapia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Gerenciamento Clínico , Humanos
20.
J Interv Cardiol ; 2020: 5024971, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33293902

RESUMO

During the last two decades, there has been a sharp increase in both interest and knowledge about the coronary microcirculation. Since these small vessels are not visible by the human eye, physiologic measurements should be used to characterize their function. The invasive methods presently used (coronary flow reserve (CFR) and index of microvascular resistance (IMR)) are operator-dependent and mandate the use of adenosine to induce hyperemia. In recent years, a new thermodilution-based method for measurement of absolute coronary blood flow and microvascular resistance has been proposed and initial procedural problems have been overcome. Presently, the technique is easy to perform using the Rayflow infusion catheter and the Coroventis software. The method is accurate, reproducible, and completely operator-independent. This method has been validated noninvasively against the current golden standard for flow assessment: Positron Emission Tomography-Computed Tomography (PET-CT). In addition, absolute flow and resistance measurements have proved to be safe, both periprocedurally and at long-term follow-up. With an increasing number of studies being performed, this method has great potential for better understanding and quantification of microvascular disease.


Assuntos
Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Microcirculação , Isquemia Miocárdica/diagnóstico , Termodiluição/métodos , Humanos , Reprodutibilidade dos Testes , Resistência Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA