Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Chemistry ; : e202401403, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38818578

RESUMO

Our society largely relies on inorganic semiconductor devices which are, so far, fabricated using expensive and complex processes requiring ultra-high vacuum equipment. Here we report on the possibility of growing a p-n junction taking advantage of electrochemical processes based on the use of aqueous solutions. The growth of the junction has been carried out using the Electrochemical Atomic Layer Deposition (E-ALD) technique, which allowed to sequentially deposit two different semiconductors, CdS and Cu2S, on an Ag(111) substrate, in a single procedure. The growth process was monitored in situ by Surface X-Ray Diffraction (SXRD) and resulted in the fabrication of a thin double-layer structure with a high degree of crystallographic order and a well-defined interface. The high-performance electrical characteristics of the device were analysed ex-situ and show the characteristic feature of a diode.

2.
Faraday Discuss ; 250(0): 9-42, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38380468

RESUMO

While a substantial amount of research activity has been conducted in fields related to organic photonics and electronics, including the development of devices such as organic field-effect transistors, organic photovoltaics, and organic light-emitting diodes for applications encompassing organic thermoelectrics, organic batteries, excitonic organic materials for photochemical and optoelectronic applications, and organic thermoelectrics, this perspective review will primarily concentrate on the emerging and rapidly expanding domain of organic bioelectronics and neuromorphics. Here we present the most recent research findings on organic transistors capable of sensing biological biomarkers down at the single-molecule level (i.e., oncoproteins, genomes, etc.) for the early diagnosis of pathological states and to mimic biological synapses, paving the way to neuromorphic applications that surpass the limitations of the traditional von Neumann computing architecture. Both organic bioelectronics and neuromorphics exhibit several challenges but will revolutionize human life, considering the development of artificial synapses to counteract neurodegenerative disorders and the development of ultrasensitive biosensors for the early diagnosis of cancer to prevent its development. Moreover, organic bioelectronics for sensing applications have also triggered the development of several wearable, flexible and stretchable biodevices for continuous biomarker monitoring.


Assuntos
Técnicas Biossensoriais , Eletrônica , Humanos , Biomarcadores , Fontes de Energia Elétrica , Sinapses
3.
Chem Rev ; 122(4): 4636-4699, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35077645

RESUMO

Bioelectronic transducing surfaces that are nanometric in size have been the main route to detect single molecules. Though enabling the study of rarer events, such methodologies are not suited to assay at concentrations below the nanomolar level. Bioelectronic field-effect-transistors with a wide (µm2-mm2) transducing interface are also assumed to be not suited, because the molecule to be detected is orders of magnitude smaller than the transducing surface. Indeed, it is like seeing changes on the surface of a one-kilometer-wide pond when a droplet of water falls on it. However, it is a fact that a number of large-area transistors have been shown to detect at a limit of detection lower than femtomolar; they are also fast and hence innately suitable for point-of-care applications. This review critically discusses key elements, such as sensing materials, FET-structures, and target molecules that can be selectively assayed. The amplification effects enabling extremely sensitive large-area bioelectronic sensing are also addressed.


Assuntos
Técnicas Biossensoriais , Transistores Eletrônicos , Técnicas Biossensoriais/métodos , Nanotecnologia
4.
Anal Bioanal Chem ; 414(18): 5657-5669, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35410389

RESUMO

Early diagnosis in a premalignant (or pre-invasive) state represents the only chance for cure in neoplastic diseases such as pancreatic-biliary cancer, which are otherwise detected at later stages and can only be treated using palliative approaches, with no hope for a cure. Screening methods for the purpose of secondary prevention are not yet available for these cancers. Current diagnostic methods mostly rely on imaging techniques and conventional cytopathology, but they do not display adequate sensitivity to allow valid early diagnosis. Next-generation sequencing can be used to detect DNA markers down to the physical limit; however, this assay requires labeling and is time-consuming. The additional determination of a protein marker that is a predictor of aggressive behavior is a promising innovative approach, which holds the potential to improve diagnostic accuracy. Moreover, the possibility to detect biomarkers in blood serum offers the advantage of a noninvasive diagnosis. In this study, both the DNA and protein markers of pancreatic mucinous cysts were analyzed in human blood serum down to the single-molecule limit using the SiMoT (single-molecule assay with a large transistor) platform. The SiMoT device proposed herein, which exploits an inkjet-printed organic semiconductor on plastic foil, comprises an innovative 3D-printed sensing gate module, consisting of a truncated cone that protrudes from a plastic substrate and is compatible with standard ELISA wells. This 3D gate concept adds tremendous control over the biosensing system stability, along with minimal consumption of the capturing molecules and body fluid samples. The 3D sensing gate modules were extensively characterized from both a material and electrical perspective, successfully proving their suitability as detection interfaces for biosensing applications. KRAS and MUC1 target molecules were successfully analyzed in diluted human blood serum with the 3D sensing gate functionalized with b-KRAS and anti-MUC1, achieving a limit of detection of 10 zM and 40 zM, respectively. These limits of detection correspond to (1 ± 1) KRAS and (2 ± 1) MUC1 molecules in the 100 µL serum sample volume. This study provides a promising application of the 3D SiMoT platform, potentially facilitating the timely, noninvasive, and reliable identification of pancreatic cancer precursor cysts.


Assuntos
Cisto Pancreático , Proteínas Proto-Oncogênicas p21(ras) , Biomarcadores , Humanos , Cisto Pancreático/diagnóstico , Cisto Pancreático/metabolismo , Cisto Pancreático/patologia , Neoplasias Pancreáticas , Plásticos , Impressão Tridimensional , Neoplasias Pancreáticas
5.
Anal Bioanal Chem ; 412(21): 5005-5014, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32185439

RESUMO

Single-molecule sensing is becoming a major driver in biomarker assays as it is foreseen to enable precision medicine to enter into everyday clinical practice. However, among the single-molecule detection methods proposed so far, only a few are fully exploitable for the ultrasensitive label-free assay of biofluids. Firstly introduced single-molecule sensing platforms encompass low-background-noise fluorescent microscopy as well as plasmonic and electrical nanotransducers; these are generally able to sense at the nanomolar concentration level or higher. Label-based single-molecule technologies relying on optical transduction and microbeads that can scavenge and detect a few biomarkers in the bulk of real biofluids, reaching ultralow detection limits, have been recently commercialized. These assays, thanks to the extremely high sensitivity and convenient handling, are new trends in the field as they are paving the way to a revolution in early diagnostics. Very recently, another new trend is the label-free, organic bioelectronic electrolyte-gated large transistors that can potentially be produced by means of large-area low-cost technologies and have been proven capable to detect a protein at the physical limit in real bovine serum. This article offers a bird's-eye view on some of the more significant single-molecule bioanalytical technologies and highlights their sensing principles and figures-of-merit such as limit of detection, need for a labelling step, and possibility to operate, also as an array, directly in real biofluids. We also discuss the new trend towards single-molecule proof-of-principle extremely sensitive technologies that can detect a protein at the zeptomolar concentration level involving label-free devices that potentially offer low-cost production and easy scalability.


Assuntos
Técnicas de Química Analítica/métodos , Imagem Individual de Molécula/métodos , Biomarcadores/análise , Técnicas Biossensoriais/métodos , Limite de Detecção , Microscopia de Fluorescência/métodos , Nanotecnologia , Reprodutibilidade dos Testes , Transistores Eletrônicos
6.
Anal Bioanal Chem ; 412(4): 811-818, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31865415

RESUMO

Early diagnosis of the infection caused by human immunodeficiency virus type-1 (HIV-1) is vital to achieve efficient therapeutic treatment and limit the disease spreading when the viremia is at its highest level. To this end, a point-of-care HIV-1 detection carried out with label-free, low-cost, and ultra-sensitive screening technologies would be of great relevance. Herein, a label-free single molecule detection of HIV-1 p24 capsid protein with a large (wide-field) single-molecule transistor (SiMoT) sensor is proposed. The system is based on an electrolyte-gated field-effect transistor whose gate is bio-functionalized with the antibody against the HIV-1 p24 capsid protein. The device exhibits a limit of detection of a single protein and a limit of quantification in the 10 molecule range. This study paves the way for a low-cost technology that can quantify, with single-molecule precision, the transition of a biological organism from being "healthy" to being "diseased" by tracking a target biomarker. This can open to the possibility of performing the earliest possible diagnosis.


Assuntos
Técnicas Biossensoriais/instrumentação , Proteína do Núcleo p24 do HIV/análise , HIV-1/isolamento & purificação , Transistores Eletrônicos , Anticorpos Imobilizados/química , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Modelos Moleculares
7.
Sensors (Basel) ; 20(13)2020 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-32630091

RESUMO

The continuous improvement of the technical potential of bioelectronic devices for biosensing applications will provide clinicians with a reliable tool for biomarker quantification down to the single molecule. Eventually, physicians will be able to identify the very moment at which the illness state begins, with a terrific impact on the quality of life along with a reduction of health care expenses. However, in clinical practice, to gather enough information to formulate a diagnosis, multiple biomarkers are normally quantified from the same biological sample simultaneously. Therefore, it is critically important to translate lab-based bioelectronic devices based on electrolyte gated thin-film transistor technology into a cost-effective portable multiplexing array prototype. In this perspective, the assessment of cost-effective manufacturability represents a crucial step, with specific regard to the optimization of the bio-functionalization protocol of the transistor gate module. Hence, we have assessed, using surface plasmon resonance technique, a sustainable and reliable cost-effective process to successfully bio-functionalize a gold surface, suitable as gate electrode for wide-field bioelectronic sensors. The bio-functionalization process herein investigated allows to reduce the biorecognition element concentration to one-tenth, drastically impacting the manufacturing costs while retaining high analytical performance.


Assuntos
Técnicas Biossensoriais , Eletrodos , Ouro , Ressonância de Plasmônio de Superfície
9.
Anal Bioanal Chem ; 411(19): 4899-4908, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30923859

RESUMO

In the last decade, saliva has been suggested as non-invasive diagnostic fluid, suitable for clinical use alternatively to blood serum and plasma. However, the clinical applicability of saliva has been hampered so far by the inadequate sensitivity of current methods to detect the lower salivary concentrations of many biomarkers monitored in blood products. Herein, a label-free biosensor based on electrolyte-gated organic thin-film transistor (EGOTFT) has been developed for the detection at the physical limit of C-reactive protein (CRP) in human saliva. CRP is a key relevant biomarker for inflammatory processes and is routinely monitored for many clinical purposes. Herein, an electrolyte-gated thin-film transistor (EGOTFT) has been proposed as a transducer of the biorecognition event taking place at the gate electrode, functionalized with a self-assembled monolayer (SAM) of highly densely packed capturing anti-CRP proteins. Thanks to the SAM, the biosensing platform herein proposed is endowed with ultra-high sensitivity, along with an extremely high selectivity, assessed by measuring the dose curves of CRP interacting with a bovine serum albumin-functionalized gate. Moreover, the biosensing platform is compatible with low-cost fabrication techniques and applicable to the ultra-sensitive detection of a plethora of clinically relevant biomarkers. Therefore, the EGOTFT device herein proposed, being able to operate in physiologically relevant fluids such as saliva, will set the ground to a major revolution in biosensing applications for early clinical detection.


Assuntos
Proteína C-Reativa/análise , Técnicas Eletroquímicas/métodos , Saliva/química , Transistores Eletrônicos , Anticorpos/imunologia , Técnicas Biossensoriais/métodos , Proteína C-Reativa/imunologia , Eletrodos , Eletrólitos , Humanos , Limite de Detecção
10.
Molecules ; 25(1)2019 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-31877834

RESUMO

The rapid spreading of resistance among common bacterial pathogens towards the misused antibiotics/disinfectant agents has drawn much attention worldwide to bacterial infections. In light of this, the present work aimed at the realization of core-shell nanoparticles possessing remarkable antimicrobial properties thanks to the synergistic action of the metal core and the disinfectant shell. Copper nanoparticles stabilized by benzalkonium chloride were prepared, characterized, and implemented in poly-vinyl-methyl ketone to obtain nanoantimicrobial composite coatings. Bioactivity tests are reported, proving the excellent disinfectant properties of the proposed nanomaterials, as compared to one of the well-known and strongest silver-based nanoantimicrobials. Applications are also briefly described.


Assuntos
Antibacterianos/síntese química , Compostos de Benzalcônio/química , Cobre/química , Desinfetantes/síntese química , Antibacterianos/química , Antibacterianos/farmacologia , Compostos de Benzalcônio/farmacologia , Cobre/farmacologia , Desinfetantes/química , Desinfetantes/farmacologia , Escherichia coli/efeitos dos fármacos , Cetonas/química , Nanopartículas Metálicas , Microscopia Eletrônica de Transmissão , Espectroscopia Fotoeletrônica , Staphylococcus aureus/efeitos dos fármacos , Propriedades de Superfície
11.
Phys Chem Chem Phys ; 19(31): 20573-20581, 2017 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-28730189

RESUMO

Electrical double layer (EDL) thin film transistors (TFTs) are an interesting class of transistors that use an electrolyte as the gating medium. Recently it has been demonstrated that pure organic solvents can also be used as gating media for TFTs without the addition of exogenous electrolytes. Here we present a systematic study of the performances of TFTs based on two different semiconductors (P3HT and ZnO) gated through nine different solvents either pure or loaded with NaCl. The nature of the solvent impacts the transfer characteristics of the TFT through a change in the gating capacitance while the threshold voltage remains unaffected. Depending on the polarity of solvents, addition of NaCl gives rise to different responses. TFTs gated through highly polar solvents are unaffected by the salt concentration while for low polarity solvents the output current increases with salt up to a plateau. Furthermore, when the semiconductor surface is covered with a high capacitance thin dielectric layer, the TFT output current becomes dependent on the NaCl concentration also for high polarity solvents. This phenomenology was rationalized considering the different contributions of Helmholtz and Guy-Chapman EDLs to the capacitance and the dielectric saturation that decreases the solvent dielectric constant within the Helmholtz EDL.

12.
Anal Bioanal Chem ; 408(15): 3943-52, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27032409

RESUMO

In this contribution, we propose a label-free immunosensor, based on a novel type of electrolyte-gated field-effect transistor (EGOFET), for ultrasensitive detection of the C-reactive protein (CRP). The recognition layer of the biosensor is fabricated by physical adsorption of the anti-CRP monoclonal antibody onto a poly-3-hexyl thiophene (P3HT) organic semiconductor surface. A supplementary nonionic hydrophilic polymer is used as a blocking agent preventing nonspecific interactions and allowing a better orientation of the antibodies immobilized onto the P3HT surface. The whole biomolecule immobilization procedure does not require any pretreatment of the organic semiconductor surface, and the whole functionalization process is completed in less than 30 min. Surface plasmon resonance (SPR) measurements were performed to assess the amount of biomolecules physisorbed onto the P3HT and to evaluate the CRP binding proprieties of the deposited anti-CRP layer. A partial surface coverage of about 23 % of adsorbed antibody molecules was found to most efficiently sense the CRP. The electrical performance of the EGOFET immunosensor was comparable to that of a bare P3HT EGOFET device, and the obtained CRP calibration curve was linear over six orders of magnitude (from 4 pM to 2 µM). The relative standard deviation of the individual calibration points, measured on immunosensors fabricated on different chips, ranged between 1 and 14 %, and a detection limit of 2 pM (220 ng/L) was established. The novel electronic immunosensor is compatible with low-cost fabrication procedures and was successfully employed for the detection of the CRP biomarker in the clinically relevant matrix serum. Graphical abstract Schematic of the EGOFET immunosensor for CRP detection. The anti-CRP monoclonal antibody layer is physisorbed on the P3HT organic semiconductor and the CRP is directly measured by a label-free electronic EGOFET transducer.


Assuntos
Técnicas Biossensoriais/métodos , Proteína C-Reativa/análise , Imunoensaio/métodos , Adsorção , Anticorpos/química , Anticorpos Imobilizados , Técnicas Biossensoriais/instrumentação , Eletrólitos/química , Imunoensaio/instrumentação , Limite de Detecção , Semicondutores , Tiofenos/química
13.
Anal Chem ; 87(22): 11337-44, 2015 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-26489723

RESUMO

A general method to obtain the efficient entrapment of mixtures of glycoenzymes in calcium alginate hydrogel is proposed in this paper. As a proof of principle, three glycoenzymes acting in series (trehalase, glucose oxidase, and horseradish peroxidase) have been coimmobilized in calcium alginate beads. The release of the enzymes from the hydrogel mesh (leakage) is avoided by exploiting the enzyme's aggregation induced by the concanavalin A. The aggregation process has been monitored by dynamic light scattering technique, while both enzyme encapsulation efficiency and leakage have been quantified spectrophotometrically. Obtained data show an encapsulation efficiency above 95% and a negligible leakage from the beads when enzyme aggregates are larger than 300 nm. Operational stability of "as prepared" beads has been largely improved by a coating of alternated shells of polycation poly(diallyldimethylammonium chloride) and of alginate. As a test for the effectiveness of the overall procedure, analytical bioassays exploiting the enzyme-containing beads have been developed for the optical determination of glucose and trehalose, and limit of detection values of 0.2 and of 40 µM, respectively, have been obtained.


Assuntos
Alginatos/metabolismo , Bioensaio , Enzimas Imobilizadas/metabolismo , Glucose Oxidase/metabolismo , Peroxidase do Rábano Silvestre/metabolismo , Trealase/metabolismo , Alginatos/química , Enzimas Imobilizadas/química , Glucose Oxidase/química , Ácido Glucurônico/química , Ácido Glucurônico/metabolismo , Ácidos Hexurônicos/química , Ácidos Hexurônicos/metabolismo , Peroxidase do Rábano Silvestre/química , Tamanho da Partícula , Propriedades de Superfície , Trealase/química
14.
Proc Natl Acad Sci U S A ; 109(17): 6429-34, 2012 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-22493224

RESUMO

Biosystems integration into an organic field-effect transistor (OFET) structure is achieved by spin coating phospholipid or protein layers between the gate dielectric and the organic semiconductor. An architecture directly interfacing supported biological layers to the OFET channel is proposed and, strikingly, both the electronic properties and the biointerlayer functionality are fully retained. The platform bench tests involved OFETs integrating phospholipids and bacteriorhodopsin exposed to 1-5% anesthetic doses that reveal drug-induced changes in the lipid membrane. This result challenges the current anesthetic action model relying on the so far provided evidence that doses much higher than clinically relevant ones (2.4%) do not alter lipid bilayers' structure significantly. Furthermore, a streptavidin embedding OFET shows label-free biotin electronic detection at 10 parts-per-trillion concentration level, reaching state-of-the-art fluorescent assay performances. These examples show how the proposed bioelectronic platform, besides resulting in extremely performing biosensors, can open insights into biologically relevant phenomena involving membrane weak interfacial modifications.

15.
Angew Chem Int Ed Engl ; 54(43): 12562-76, 2015 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-26420480

RESUMO

Thin-film transistors can be used as high-performance bioelectronic devices to accomplish tasks such as sensing or controlling the release of biological species as well as transducing the electrical activity of cells or even organs, such as the brain. Organic, graphene, or zinc oxide are used as convenient printable semiconducting layers and can lead to high-performance low-cost bioelectronic sensing devices that are potentially very useful for point-of-care applications. Among others, electrolyte-gated transistors are of interest as they can be operated as capacitance-modulated devices, because of the high capacitance of their charge double layers. Specifically, it is the capacitance of the biolayer, being lowest in a series of capacitors, which controls the output current of the device. Such an occurrence allows for extremely high sensitivity towards very weak interactions. All the aspects governing these processes are reviewed here.


Assuntos
Técnicas Biossensoriais/métodos , Eletrônica Médica/métodos , Impressão/métodos , Transistores Eletrônicos , Animais , Técnicas Biossensoriais/instrumentação , Capacitância Elétrica , Eletrólitos/química , Eletrônica Médica/instrumentação , Desenho de Equipamento , Grafite/química , Humanos , Impressão/instrumentação , Termodinâmica , Óxido de Zinco/química
16.
Chem Soc Rev ; 42(22): 8612-28, 2013 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-24018860

RESUMO

The functioning principles of electronic sensors based on organic semiconductor field-effect transistors (OFETs) are presented. The focus is on biological sensors but also chemical ones are reviewed to address general features. The field-induced electronic transport and the chemical and biological interactions for the sensing, each occurring at the relevant functional interface, are separately introduced. Once these key learning points have been acquired, the combined picture for the FET electronic sensing is proposed. The perspective use of such devices in point-of-care is introduced, after some basics on analytical biosensing systems are provided as well. This tutorial review includes also a necessary overview of the OFET sensing structures, but the focus will be on electronic rather than electrochemical detection. The differences among the structures are highlighted along with the implications on the performance level in terms of key analytical figures of merit such as: repeatability, sensitivity and selectivity.

17.
Sensors (Basel) ; 14(9): 16869-80, 2014 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-25215940

RESUMO

Bottom- and top-contact organic thin film transistors (OTFTs) were fabricated, using poly(3-hexylthiophene-2,5-diyl) (P3HT) and poly[2,5-bis(3-tetradecylthiophen-2-yl)thieno[3,2-b]thiophene] (PBTTT-C16) as p-type channel semiconductors. Four different types of OTFTs were fabricated and investigated as gas sensors against three volatile organic compounds, with different associated dipole moments. The OTFT-based sensor responses were evaluated with static and transient current measurements. A comparison between the different architectures and the relative organic semiconductor was made.


Assuntos
Condutometria/instrumentação , Eletrodos , Gases/química , Membranas Artificiais , Polímeros/química , Tiofenos/química , Transistores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento , Compostos Orgânicos Voláteis/análise
18.
Nanoscale Adv ; 6(2): 516-523, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38235094

RESUMO

Herein, we describe a novel method for producing cadmium-selenide nanoparticles (CdSe NPs) with controlled size using apoferritin as a bionanoreactor triggered by local pH change at the electrode/solution interface. Apoferritin is known for its reversible self-assembly at alkaline pH. The pH change is induced electrochemically by reducing O2 through the application of sufficiently negative voltages and bioelectrochemically through O2 reduction catalyzed by laccase, co-immobilized with apoferritin on the electrode surface. Specifically, a Ti electrode is modified with (3-aminopropyl)triethoxysilane, followed by glutaraldehyde cross-linking (1.5% v/v in H2O) of apoferritin (as the bionanoreactor) and laccase (as the local pH change triggering system). This proposed platform offers a universal approach for controlling the synthesis of semiconductor NPs within a bionanoreactor solely driven by (bio)electrochemical inputs. The CdSe NPs obtained through different synthetic approaches, namely electrochemical and bioelectrochemical, were characterized spectroscopically (UV-Vis, Raman, XRD) and morphologically (TEM). Finally, we conducted online monitoring of CdSe NPs formation within the apoferritin core by integrating the electrochemical system with LWs. The quantity of CdSe NPs produced through bioelectrochemical means was determined to be 2.08 ± 0.12 mg after 90 minutes of voltage application in the presence of O2. TEM measurements revealed that the bioelectrochemically synthesized CdSe NPs have a diameter of 4 ± 1 nm, accounting for 85% of the size distribution, a result corroborated by XRD data. Further research is needed to explore the synthesis of nanoparticles using different biological nanoreactors, as the process can be challenging due to the elevated buffer capacitance of biological media.

19.
ACS Appl Mater Interfaces ; 16(17): 22443-22454, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38629300

RESUMO

Herein, a strategy to stamp laser-produced reduced graphene oxide (rGO) onto flexible polymers using only office-grade tools, namely, roll-to-roll thermal stamping, is proposed, proving for the first time its effectiveness for direct bioelectrocatalysis. This straightforward, scalable, and low-cost approach allows us to overcome the limits of the integration of laser-induced rGO-films in bioanalytical devices. Laser-produced rGO has been thermally stamped (TS) onto different polymeric substrates (PET, PVC, and EVA) using a simple roll-laminator; the obtained TS-rGO films have been compared with the native rGO (untransferred) via morphochemical and electrochemical characterization. Particularly, the direct electron transfer (DET) reaction between fructose dehydrogenase (FDH) and TS-rGO transducers has been investigated, with respect to the influence of the amount of enzyme on the catalytic process. Remarkable differences have been observed among TS-rGO transducers; PET proved to be the elective substrate to support the transfer of the laser-induced rGO, allowing the preservation of the morphochemical features of the native material and returning a reduced capacitive current. Noteworthily, TS-rGOs ensure superior electrocatalysis using a very low amount of FDH units (15 mU). Eventually, TS-rGO-based third-generation complete enzymatic biosensors were fabricated via low-cost benchtop technologies. TS-rGOPET exhibited bioanalytical performances superior to the native rGO, allowing a sensitive (0.0289 µA cm-2 µM-1) and reproducible (RSD = 3%, n = 3) d-fructose determination at the nanomolar level (LOD = 0.2 µM). TS-rGO exploitability as a point-of-need device was proved via the monitoring of d-fructose during banana (Musa acuminata) postharvest ripening, returning accurate (recoveries 110-90%; relative error -13/+1%) and reproducible (RSD ≤ 7%; n = 3) data.


Assuntos
Grafite , Lasers , Grafite/química , Transporte de Elétrons , Técnicas Eletroquímicas , Desidrogenases de Carboidrato/química , Desidrogenases de Carboidrato/metabolismo , Técnicas Biossensoriais , Oxirredução
20.
Adv Mater ; 36(13): e2309705, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38108547

RESUMO

Screening asymptomatic organisms (humans, animals, plants) with a high-diagnostic accuracy using point-of-care-testing (POCT) technologies, though still visionary holds great potential. Convenient surveillance requires easy-to-use, cost-effective, ultra-portable but highly reliable, in-vitro-diagnostic devices that are ready for use wherever they are needed. Currently, there are not yet such devices available on the market, but there are a couple more promising technologies developed at readiness-level 5: the Clustered-Regularly-Interspaced-Short-Palindromic-Repeats (CRISPR) lateral-flow-strip tests and the Single-Molecule-with-a-large-Transistor (SiMoT) bioelectronic palmar devices. They both hold key features delineated by the World-Health-Organization for POCT systems and an occurrence of false-positive and false-negative errors <1-5% resulting in diagnostic-selectivity and sensitivity >95-99%, while limit-of-detections are of few markers. CRISPR-strip is a molecular assay that, can detect down to few copies of DNA/RNA markers in blood while SiMoT immunometric and molecular test can detect down to a single oligonucleotide, protein marker, or pathogens in 0.1mL of blood, saliva, and olive-sap. These technologies can prospectively enable the systematic and reliable surveillance of asymptomatic ones prior to worsening/proliferation of illnesses allowing for timely diagnosis and swift prognosis. This could establish a proactive healthcare ecosystem that results in effective treatments for all living organisms generating diffuse and well-being at efficient costs.


Assuntos
Sistemas CRISPR-Cas , Saúde Única , Animais , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , RNA
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA