Resultados 1 - 20 de 168
Filtrar
1.
Respir Res ; 24(1): 226, 2023 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-37742015

RESUMO

BACKGROUND: Small airways disease plays a key role in the pathogenesis of chronic obstructive pulmonary disease (COPD) and is a major cause of obstruction; therefore, it is a critical pharmacotherapy target. This study evaluated lung deposition of two inhaled corticosteroid (ICS)/long-acting ß2-agonist/long-acting muscarinic antagonist single-inhaler triple therapies using in silico functional respiratory imaging (FRI). Deposition was assessed using real-world inhalation profiles simulating everyday use where optimal inhalation may be compromised. METHODS: Three-dimensional airway models were produced from 20 patients with moderate-to-very severe COPD. Total, central, and regional small airways deposition as a percentage of delivered dose of budesonide/glycopyrronium/formoterol fumarate dihydrate (BGF) 160/7.2/5 µg per actuation and fluticasone furoate/umeclidinium/vilanterol (FF/UM/VI) 100/62.5/25 µg were evaluated using in silico FRI based on in vitro aerodynamic particle size distributions of each device. Simulations were performed using multiple inhalation profiles of varying durations and flow rates representing patterns suited for a pressurized metered-dose inhaler or dry-powder inhaler (four for BGF, two for FF/UM/VI, with one common profile). For the common profile, deposition for BGF versus FF/UM/VI was compared post-hoc using paired t-tests. RESULTS: Across inhalation profiles, mean total lung deposition was consistently higher with BGF (47.0-54.1%) versus FF/UM/VI (20.8-22.7%) and for each treatment component, with greater deposition for BGF also seen in the central large airways. Mean regional small airways deposition was also greater across inhalation profiles with BGF (16.9-23.6%) versus FF/UM/VI (6.8-8.7%) and for each treatment component. For the common profile, total, central, and regional small airways deposition were significantly greater for BGF versus FF/UM/VI (nominal p < 0.001), overall and for treatment components; notably, regional small airways deposition of the ICS components was approximately five-fold greater with budesonide versus fluticasone furoate (16.1% vs. 3.3%). CONCLUSIONS: BGF was associated with greater total, central, and small airways deposition for all components versus FF/UM/VI. Importantly, using an identical inhalation profile, there was an approximately five-fold difference in small airways deposition for the ICS components, with only a small percentage of the ICS from FF/UM/VI reaching the small airways. Further research is needed to understand if the enhanced delivery of BGF translates to clinical benefits.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Fluticasona , Budesonida , Inaladores de Pó Seco , Pulmão/diagnóstico por imagem
2.
BMC Pulm Med ; 23(1): 302, 2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37592263

RESUMO

BACKGROUND: Correct inhaler use depends on a complex interplay of factors, including device preparation and generating sufficient inspiratory flow. It is currently unknown which inhalation technique errors can be considered critical in Chronic Obstructive Pulmonary Disease (COPD) patients on Dry Powder Inhaler (DPI) maintenance therapy. OBJECTIVE: To investigate the association between inhalation technique errors and health status or exacerbations in patients with COPD. Additionally, the association between the number of errors and COPD outcomes was determined. METHODS: The PIFotal study is a cross-sectional multi-country observational study in a primary care setting, including 1434 COPD patients aged ≥ 40 years (50.1% female; mean age 69.2 yrs) using a DPI for their maintenance therapy. Inhalation technique was video recorded and scored by two independent researchers using inhaler-specific checklists. Health status was assessed with two questionnaires; the Clinical COPD Questionnaire (CCQ) and the COPD Assessment Test (CAT). The number of moderate and severe exacerbations in the past 12 months was recorded. Critical errors were identified based on their association with health status or exacerbations through multi-level prediction models adjusted for identified confounding. RESULTS: Errors in inhalation technique steps 'Breathe in', 'Hold breath', and 'Breathe out calmly after inhalation' were significantly associated with poorer CCQ and CAT outcomes and thus deemed critical. None of the errors were significantly associated with moderate exacerbations. Patients with errors 'Preparation', 'Hold inhaler in correct position during inhalation', and 'Breathe in' had significantly more severe exacerbations, and therefore these errors were also deemed critical. 81.3% of patients with COPD made at least one critical error. Specific combinations of errors were associated with worse outcomes. The more inhalation technique errors identified, the poorer the health status and the higher the exacerbation rate. CONCLUSION: In this study, we identified multiple critical inhalation technique errors in COPD patients using DPIs each associated with poorer outcomes. Explorative analysis revealed that specific combinations of errors may be of clinical relevance, especially those related to the inhalation manoeuvre. COPD outcomes worsened with increasing error count. These results warrant further prospective longitudinal studies to establish the effect of correcting these errors on COPD control. TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT04532853 (31/08/2020).


Assuntos
Inaladores de Pó Seco , Doença Pulmonar Obstrutiva Crônica , Feminino , Masculino , Humanos , Estudos Transversais , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Nível de Saúde , Lista de Checagem
3.
Eur Respir J ; 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35169025

RESUMO

Although asthma is very common affecting 5-10% of the population, the diagnosis of asthma in adults remains a challenge in the real world that results in both over- and under-diagnosis. A task force (TF) was set up by the European Respiratory Society to systematically review the literature on the diagnostic accuracy of tests used to diagnose asthma in adult patients and provide recommendation for clinical practice.The TF defined eight PICO (Population, Index, Comparator, and Outcome) questions that were assessed using the GRADE (Grading of Recommendations, Assessment, Development and Evaluation) approach, The TF utilised the outcomes to develop an evidenced-based diagnostic algorithm, with recommendations for a pragmatic guideline for everyday practice that was directed by real-life patient experiences.The TF support the initial use of spirometry followed, and if airway obstruction is present, by bronchodilator reversibility testing. If initial spirometry fails to show obstruction, further tests should be performed in the following order: FeNO, PEF variability or in secondary care, bronchial challenge. We present the thresholds for each test that are compatible with a diagnosis of asthma in the presence of current symptoms.The TF reinforce the priority to undertake spirometry and recognise the value of measuring blood eosinophils and serum IgE to phenotype the patient. Measuring gas trapping by body plethysmography in patients with preserved FEV1/FVC ratio deserves further attention. The TF draw attention on the difficulty of making a correct diagnosis in patients already receiving inhaled corticosteroids, the comorbidities that may obscure the diagnosis, the importance of phenotyping, and the necessity to consider the patient experience in the diagnostic process.

4.
BMC Med Educ ; 22(1): 81, 2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35125094

RESUMO

BACKGROUND: Imperial College London launched a new, spiral undergraduate medical curriculum in September 2019. Clinical & Scientific Integrative cases (CSI) is an innovative, flagship module, which uses pioneering methodology to provide early-years learning that [1] is patient-centred, [2] integrates clinical and scientific curriculum content, [3] develops advanced team-work skills and [4] provides engaging, student-driven learning. These aims are designed to produce medical graduates equipped to excel in a modern healthcare environment. METHODS: CSI has adopted a novel educational approach which utilises contemporary digital resources to deliver a collaborative case-based learning (CBL) component, paired with a team-based learning (TBL) component that incorporates both learning and programmatic assessment. This paper serves to explore how first-year students experienced CSI in relation to its key aims, drawing upon quantitative and qualitative data from feedback surveys from CSI's inaugural year. It provides a description and analysis of the module's design, delivery, successes and challenges. RESULTS: Our findings indicate that CSI has been extremely well-received and that the majority of students agree that it met its aims. Survey outputs indicate success in integrating multiple elements of the curriculum, developing an early holistic approach towards patients, expediting the development of important team-working skills, and delivering authentic and challenging clinical problems, which our students found highly relevant. Challenges have included supporting students to adapt to a student-driven, deep learning approach. CONCLUSIONS: First-year students appear to have adopted a patient-centred outlook, the ability to integrate knowledge from across the curriculum, an appreciation for other team members and the self-efficacy to collaboratively tackle challenging, authentic clinical problems. Ultimately, CSI's innovative design is attractive and pertinent to the needs of modern medical students and ultimately, future doctors.


Assuntos
Educação de Graduação em Medicina , Práticas Interdisciplinares , Estudantes de Medicina , Currículo , Retroalimentação , Humanos , Autoeficácia
5.
Am J Physiol Lung Cell Mol Physiol ; 320(1): L73-L83, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33146567

RESUMO

Despite advances in the pathophysiology of chronic obstructive pulmonary disease (COPD), there is a distinct lack of biochemical markers to aid clinical management. Microvesicles (MVs) have been implicated in the pathophysiology of inflammatory diseases including COPD, but their association to COPD disease severity remains unknown. We analyzed different MV populations in plasma and bronchoalveolar lavage fluid (BALF) taken from 62 patients with mild to very severe COPD (51% male; mean age: 65.9 yr). These patients underwent comprehensive clinical evaluation (symptom scores, lung function, and exercise testing), and the capacity of MVs to be clinical markers of disease severity was assessed. We successfully identified various MV subtype populations within BALF [leukocyte, polymorphonuclear leukocyte (PMN; i.e., neutrophil), monocyte, epithelial, and platelet MVs] and plasma (leukocyte, PMN, monocyte, and endothelial MVs) and compared each MV population to disease severity. BALF neutrophil MVs were the only population to significantly correlate with the clinical evaluation scores including forced expiratory volume in 1 s, modified Medical Research Council dyspnea score, 6-min walk test, hyperinflation, and gas transfer. BALF neutrophil MVs, but not neutrophil cell numbers, also strongly correlated with BODE index. We have undertaken, for the first time, a comprehensive evaluation of MV profiles within BALF/plasma of COPD patients. We demonstrate that BALF levels of neutrophil-derived MVs are unique in correlating with a number of key functional and clinically relevant disease severity indexes. Our results show the potential of BALF neutrophil MVs for a COPD biomarker that tightly links a key pathophysiological mechanism of COPD (intra-alveolar neutrophil activation) with clinical severity/outcome.


Assuntos
Líquido da Lavagem Broncoalveolar/química , Micropartículas Derivadas de Células/patologia , Neutrófilos/patologia , Alvéolos Pulmonares/patologia , Doença Pulmonar Obstrutiva Crônica/patologia , Índice de Gravidade de Doença , Idoso , Micropartículas Derivadas de Células/metabolismo , Citocinas/metabolismo , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Neutrófilos/metabolismo , Alvéolos Pulmonares/metabolismo , Doença Pulmonar Obstrutiva Crônica/etiologia , Doença Pulmonar Obstrutiva Crônica/metabolismo , Testes de Função Respiratória
6.
Respir Res ; 22(1): 261, 2021 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-34620167

RESUMO

BACKGROUND: Triple therapy with inhaled corticosteroids/long-acting muscarinic antagonists/long-acting ß2-agonists (ICS/LAMA/LABA) is recommended for patients with chronic obstructive pulmonary disease (COPD) with continued symptoms or exacerbations, despite treatment with LAMA/LABA or ICS/LABA. The pulmonary, extrathoracic, and regional lung deposition patterns of a radiolabeled ICS/LAMA/LABA triple fixed-dose combination budesonide/glycopyrrolate/formoterol fumarate (BGF 320/18/9.6 µg), delivered via a single Aerosphere metered dose inhaler (MDI) were previously assessed in healthy volunteers and showed good deposition to the central and peripheral airways (whole lung deposition: 37.7%). Here, we report the findings assessing BGF in patients with moderate-to-very severe COPD. METHODS: This phase I, single-dose, open-label gamma scintigraphy imaging study (NCT03906045) was conducted in patients with moderate-to-very severe COPD. Patients received two actuations of BGF MDI (160/9/4.8 µg per actuation) radiolabeled with technetium­99­pertechnetate, not exceeding 5 MBq per actuation. Immediately following each inhalation, patients performed a breath-hold of up to 10 s, then exhaled into an exhalation filter. Gamma scintigraphy imaging of the anterior and posterior views of the lungs and stomach, and a lateral head and neck view, were performed immediately after exhalation. The primary objective of the study was to assess the pulmonary deposition of BGF. Secondary objectives assessed the deposited dose of radiolabeled BGF in the oropharyngeal and stomach regions, on the actuator, and on the exhalation filter in addition to regional airway deposition patterns in the lungs. RESULTS: The mean BGF emitted dose deposited in the lungs was 32.1% (standard deviation [SD] 15.6) in patients with moderate-to-very severe COPD, 35.2% (SD 12.8) in patients with moderate COPD, and 28.7% (SD 18.4) in patients with severe/very severe COPD. Overall, the mean normalized outer/inner ratio was 0.55 (SD 0.19), while the standardized central/peripheral ratio was 2.21 (SD 1.64). CONCLUSIONS: Radiolabeled BGF 320/18/9.6 µg was efficiently delivered and deposited throughout the entire lung, including large and small airways, in patients with moderate-to-very severe COPD, with similar deposition in patients with moderate COPD and patients with severe/very severe COPD. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03906045. Registered 8 April 2019, https://clinicaltrials.gov/ct2/show/NCT03906045.


Assuntos
Agonistas de Receptores Adrenérgicos beta 2 , Broncodilatadores , Glucocorticoides , Pulmão , Antagonistas Muscarínicos , Doença Pulmonar Obstrutiva Crônica , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Administração por Inalação , Agonistas de Receptores Adrenérgicos beta 2/administração & dosagem , Agonistas de Receptores Adrenérgicos beta 2/efeitos adversos , Broncodilatadores/administração & dosagem , Broncodilatadores/efeitos adversos , Meios de Contraste , Glucocorticoides/administração & dosagem , Glucocorticoides/efeitos adversos , Pulmão/diagnóstico por imagem , Pulmão/efeitos dos fármacos , Pulmão/fisiopatologia , Inaladores Dosimetrados , Antagonistas Muscarínicos/administração & dosagem , Antagonistas Muscarínicos/efeitos adversos , Valor Preditivo dos Testes , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Cintilografia , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Pertecnetato Tc 99m de Sódio , Fatores de Tempo , Resultado do Tratamento
7.
Chron Respir Dis ; 18: 1479973120986228, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33522304

RESUMO

PLAIN LANGUAGE SUMMARY: Inhalers are often used to treat patients with chronic obstructive pulmonary disease (COPD). However, there are many available, which can lead to confusion and poor inhaler technique. It is important for a patient to be happy with their inhaler. This study looked at how patients liked the re-usable Respimat® Soft Mist™ inhaler vs. their previous inhaler. It also asked whether they would be willing to continue using the device at the end of the study period.After 4-6 weeks of using the re-usable device, patients reported that they were happy with the inhaler and most would be willing to carry on using it.Overall, these results show that doctors can prescribe Respimat re-usable to patients, even if the patient has not used the inhaler before.


Assuntos
Broncodilatadores , Doença Pulmonar Obstrutiva Crônica , Administração por Inalação , Broncodilatadores/uso terapêutico , Humanos , Nebulizadores e Vaporizadores , Percepção , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico
8.
Handb Exp Pharmacol ; 260: 143-159, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31792683

RESUMO

Inhalation therapy is one of the oldest approaches to the therapy of diseases of the respiratory tract. It is well recognised today that the most effective and safe means of treating the lungs is to deliver drugs directly to the airways. Surprisingly, the delivery of therapeutic aerosols has a rich history dating back more than 2,000 years to Ayurvedic medicine in India, but in many respects, the introduction of the first pressurised metered-dose inhaler (pMDI) in 1956 marked the beginning of the modern pharmaceutical aerosol industry. The pMDI was the first truly portable and convenient inhaler that effectively delivered drug to the lung and quickly gained widespread acceptance. Since 1956, the pharmaceutical aerosol industry has experienced dramatic growth. The signing of the Montreal Protocol in 1987 to reduce the use of CFCs as propellants for aerosols led to a surge in innovation that resulted in the diversification of inhaler technologies with significantly enhanced delivery efficiency, including modern pMDIs, dry powder inhalers and nebuliser systems. There is also great interest in tailoring particle size to deliver drugs to treat specific areas of the respiratory tract. One challenge that has been present since antiquity still exists, however, and that is ensuring that the patient has access to the medication and understands how to use it effectively. In this article, we will provide a summary of therapeutic aerosol delivery systems from ancient times to the present along with a look to the future.


Assuntos
Sistemas de Liberação de Medicamentos/história , Pulmão/efeitos dos fármacos , Inaladores Dosimetrados , Nebulizadores e Vaporizadores , Administração por Inalação , Aerossóis , História do Século XX , História do Século XXI , Humanos
10.
Respir Res ; 19(1): 10, 2018 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-29338792

RESUMO

BACKGROUND: Inhaled drug delivery is the cornerstone treatment for asthma and chronic obstructive pulmonary disease (COPD). However, use of inhaler devices can be challenging, potentially leading to critical errors in handling that can significantly reduce drug delivery to the lungs and effectiveness of treatment. METHODS: A systematic review was conducted to define 'critical' errors and their impact on health outcomes and resource use between 2004 and 2016, using key search terms for inhaler errors in asthma and COPD (Search-1) and associated health-economic and patient burden (Search-2). RESULTS: Search-1 identified 62 manuscripts, 47 abstracts, and 5 conference proceedings (n = 114 total). Search-2 identified 9 studies. We observed 299 descriptions of critical error. Age, education status, previous inhaler instruction, comorbidities and socioeconomic status were associated with worse handling error frequency. A significant association was found between inhaler errors and poor disease outcomes (exacerbations), and greater health-economic burden. CONCLUSIONS: We have shown wide variations in how critical errors are defined, and the evidence shows an important association between inhaler errors and worsened health outcomes. Given the negative impact diminished disease outcomes impose on resource use, our findings highlight the importance of achieving optimal inhaler technique, and a need for a consensus on defining critical and non-critical errors.


Assuntos
Antiasmáticos/administração & dosagem , Asma/tratamento farmacológico , Inaladores Dosimetrados/normas , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Asma/diagnóstico , Asma/epidemiologia , Humanos , Inaladores Dosimetrados/tendências , Nebulizadores e Vaporizadores/tendências , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Resultado do Tratamento
11.
Respir Res ; 19(1): 25, 2018 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-29409488

RESUMO

BACKGROUND: Our aim was to investigate total and regional lung delivery of salbutamol in subjects with idiopathic pulmonary fibrosis (IPF). METHODS: The TOPICAL study was a 4-period, partially-randomised, controlled, crossover study to investigate four aerosolised approaches in IPF subjects. Nine subjects were randomised to receive 99mTechnetium-labelled monodisperse salbutamol (1.5 µm or 6 µm; periods 1 and 2). Subjects also received radio-labelled salbutamol using a polydisperse nebuliser (period 3) and unlabelled salbutamol (400 µg) using a polydisperse pressurized metered dose inhaler with volumatic spacer (pMDI; period 4). RESULTS: Small monodisperse particles (1.5 µm) achieved significantly better total lung deposition (TLD, mean % ± SD) than larger particles (6 µm), where polydisperse nebulisation was poor; (TLD, 64.93 ± 10.72; 50.46 ± 17.04; 8.19 ± 7.72, respectively). Small monodisperse particles (1.5 µm) achieved significantly better lung penetration (mean % ± SD) than larger particles (6 µm), and polydisperse nebulisation showed lung penetration similar to the small particles; PI (mean ± SD) 0.8 ± 0.16, 0.49 ± 0.21, and 0.73 ± 0.19, respectively. Higher dose-normalised plasma salbutamol levels were observed following monodisperse 1.5 µm and 6 µm particles, compared to polydisperse pMDI inhalation, while lowest plasma levels were observed following polydisperse nebulisation. CONCLUSION: Our data is the first systematic investigation of inhaled drug delivery in fibrotic lung disease. We provide evidence that inhaled drugs can be optimised to reach the peripheral areas of the lung where active scarring occurs in IPF. TRIAL REGISTRATION: This trial was registered on clinicaltrials.gov ( NCT01457261 ).


Assuntos
Albuterol/administração & dosagem , Broncodilatadores/administração & dosagem , Sistemas de Liberação de Medicamentos/métodos , Fibrose Pulmonar Idiopática/tratamento farmacológico , Administração por Inalação , Administração Tópica , Idoso , Idoso de 80 Anos ou mais , Albuterol/metabolismo , Estudos Cross-Over , Relação Dose-Resposta a Droga , Feminino , Humanos , Fibrose Pulmonar Idiopática/metabolismo , Masculino , Pessoa de Meia-Idade
12.
Curr Opin Pulm Med ; 24(1): 63-69, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29036020

RESUMO

PURPOSE OF REVIEW: The article aims to provide an updated and evidence-based review of the innovative electronic health interventions to monitor and improve inhaler technique and adherence to recommended therapy in asthma. RECENT FINDINGS: Out of the 290 articles identified by the search strategy, 23 manuscripts fulfilled the review inclusion criteria. Included studies mainly addressed m-health, electronic reminders, telemedicine, and inhaler tracker interventions. Investigations were performed both in adults and children. Remarkably, the majority of studies were performed in the most recent years, showing a progressively increasing interest for this field. Existing findings appear to be of moderate-high quality. A significant number of papers, however, were published in scientific journals with a low impact factor (<2). Furthermore, extremely high heterogeneity was found in the considered study endpoints. Collected evidence supports a relevant role for e-health in monitoring and improving inhaler use and treatment adherence in asthma. The patients' acceptance and satisfaction towards assessed interventions were also found to be positive. SUMMARY: E-health represents a highly valuable tool for achieving optimal and personalized asthma management. Unanimously agreed and adopted standards for conducting trials and reporting results on e-health in asthma are however needed to fully understand its real added value.


Assuntos
Antiasmáticos/administração & dosagem , Asma/tratamento farmacológico , Adesão à Medicação/estatística & dados numéricos , Nebulizadores e Vaporizadores , Telemedicina , Terapia Diretamente Observada , Medicina Baseada em Evidências , Humanos , Educação de Pacientes como Assunto , Sistemas de Alerta
13.
Eur Respir J ; 49(5)2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28461291

RESUMO

Mobile healthcare (mHealth) has the potential to revolutionise the self-management of long-term medical conditions such as asthma. A user-centred design is integral if mHealth is to be embraced by patients and healthcare professionals.The aim of this study was to determine the perspectives of individuals with asthma and healthcare professionals on the use of mHealth for asthma self-management.We used a sequential exploratory mixed methods design; focus groups informed the development of questionnaires, which were disseminated to individuals with asthma and healthcare professionals.Focus group participants (18 asthma patients and five healthcare professionals) identified 12 potential uses of mHealth. Questionnaire results showed that individuals with asthma (n=186) most frequently requested an mHealth system to monitor asthma over time (72%) and to collect data to present to healthcare teams (70%). In contrast, healthcare professionals (n=63) most frequently selected a system alerting patients to deteriorating asthma control (86%) and advising them when to seek medical attention (87%). Individuals with asthma were less likely than healthcare professionals (p<0.001) to believe that assessing medication adherence and inhaler technique could improve asthma control.Our data provide strong support for mHealth for asthma self-management, but highlight fundamental differences between the perspectives of patients and healthcare professionals.


Assuntos
Asma/terapia , Atitude do Pessoal de Saúde , Autogestão , Telemedicina/estatística & dados numéricos , Adulto , Estudos de Avaliação como Assunto , Feminino , Grupos Focais , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Países Baixos , Inquéritos e Questionários , Reino Unido , Adulto Jovem
14.
Pulm Pharmacol Ther ; 47: 93-98, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28476638

RESUMO

This review reflects upon the management of cough in primary, secondary and tertiary care settings. It reviews the burden of cough, the diagnostic tools employed to investigate the cause of cough and pragmatic treatment strategies. A clinical case vignette presenting in primary care highlights the challenges of managing cough by family practitioners. An approach to establishing a persistent cough clinic service in secondary care is described. Finally, the entity of idiopathic cough in tertiary care and the specialist approaches to treating recalcitrant cough are addressed.


Assuntos
Efeitos Psicossociais da Doença , Tosse/terapia , Atenção Primária à Saúde/métodos , Animais , Tosse/diagnóstico , Tosse/fisiopatologia , Humanos , Atenção Secundária à Saúde/métodos , Atenção Terciária à Saúde/métodos
16.
Breast J ; 23(6): 647-655, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28397344

RESUMO

Patients with a diagnosis of invasive breast cancer are increasingly undergoing breast magnetic resonance imaging (MRI) for preoperative staging including evaluation of axillary lymph node metastases (ALNM). This retrospective study aims to evaluate the utility of adding axillary ultrasound (AUS) in the preoperative setting when an MRI is planned or has already been performed. This IRB approved, HIPAA compliant study reviewed a total of 271 patients with a new diagnosis of invasive breast cancer at a single institution, between June 1, 2010 and June 30, 2013. The study included patients who received both AUS and MRI for preoperative staging. Data were divided into two cohorts, patients who underwent MRI prior to AUS and those who underwent AUS prior to MRI. AUS and MRI reports were categorized according to BI-RADS criteria as "suspicious" or "not suspicious" for ALNM. In the setting of a negative MRI and subsequent positive AUS, only one out of 25 cases (4%) were positive for metastases after correlating with histologic pathology. MRI detected metastatic disease in four out of 27 (15%) patients who had false-negative AUS performed prior to MRI. Our results indicate the addition of AUS after preoperative MRI does not contribute significantly to increased detection of missed disease. MRI could serve as the initial staging imaging method of the axilla in the setting that AUS is not initially performed and may be valuable in identification of lymph nodes not identified on AUS.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Axila/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Reações Falso-Negativas , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Estudos Retrospectivos , Biópsia de Linfonodo Sentinela , Ultrassonografia
17.
BMC Med Inform Decis Mak ; 17(Suppl 3): 173, 2017 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-29297393

RESUMO

BACKGROUND: Chronic obstructive pulmonary disease (COPD) and asthma are considered as the two most widespread obstructive lung diseases, whereas they affect more than 500 million people worldwide. Unfortunately, the requirement for detailed geometric models of the lungs in combination with the increased computational resources needed for the simulation of the breathing did not allow great progress to be made in the past for the better understanding of inflammatory diseases of the airways through detailed modelling approaches. In this context, computational fluid dynamics (CFD) simulations accompanied by fluid particle tracing (FPT) analysis of the inhaled ambient particles are deemed critical for lung function assessment. Also they enable the understanding of particle depositions on the airways of patients, since these accumulations may affect or lead to inflammations. In this direction, the current study conducts an initial investigation for the better comprehension of particle deposition within the lungs. More specifically, accurate models of the airways obstructions that relate to pulmonary disease are developed and a thorough assessment of the airflow behavior together with identification of the effects of inhaled particle properties, such as size and density, is conducted. Our approach presents a first step towards an effective personalization of pulmonary treatment in regards to the geometric characteristics of the lungs and the in depth understanding of airflows within the airways. METHODS: A geometry processing technique involving contraction algorithms is established and used to employ the different respiratory arrangements associated with lung related diseases that exhibit airways obstructions. Apart from the normal lung case, two categories of obstructed cases are examined, i.e. models with obstructions in both lungs and models with narrowings in the right lung only. Precise assumptions regarding airflow and deposition fraction (DF) over various sections of the lungs are drawn by simulating these distinct incidents through the finite volume method (FVM) and particularly the CFD and FPT algorithms. Moreover, a detailed parametric analysis clarifies the effects of the particles size and density in terms of regional deposition upon several parts of the pulmonary system. In this manner, the deposition pattern of various substances can be assessed. RESULTS: For the specific case of the unobstructed lung model most particles are detected on the right lung (48.56% of total, when the air flowrate is 12.6 L/min), a fact that is also true when obstructions arise symmetrically in both lungs (51.45% of total, when the air flowrate is 6.06 L/min and obstructions occur after the second generation). In contrast, when narrowings are developed on the right lung only, most particles are pushed on the left section (68.22% of total, when the air flowrate is 11.2 L/min) indicating that inhaled medication is generally deposited away from the areas of inflammation. This observation is useful when designing medical treatment of lung diseases. Furthermore, particles with diameters from 1 µm to 10 µm are shown to be mainly deposited on the lower airways, whereas particles with diameters of 20 µm and 30 µm are mostly accumulated in the upper airways. As a result, the current analysis indicates increased DF levels in the upper airways when the particle diameter is enlarged. Additionally, when the particles density increases from 1000 Kg/m3 to 2000 Kg/m3, the DF is enhanced on every generation and for all cases investigated herein. The results obtained by our simulations provide an accurate and quantitative estimation of all important parameters involved in lung modeling. CONCLUSIONS: The treatment of respiratory diseases with inhaled medical substances can be advanced by the clinical use of accurate CFD and FPT simulations and specifically by evaluating the deposition of inhaled particles in a regional oriented perspective in regards to different particle sizes and particle densities. Since a drug with specific characteristics (i.e. particle size and density) exhibits maximum deposition on particular lung areas, the current study provides initial indications to a qualified physician for proper selection of medication.


Assuntos
Administração por Inalação , Simulação por Computador , Pneumopatias Obstrutivas , Modelos Biológicos , Humanos , Hidrodinâmica , Pneumopatias Obstrutivas/tratamento farmacológico , Tamanho da Partícula