Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Phys Rev Lett ; 129(11): 111801, 2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-36154394

RESUMO

CUPID-0, an array of Zn^{82}Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers' technology. The first project phase (March 2017-December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, ^{82}Se, to be set. After a six month long detector upgrade, CUPID-0 began its second and last phase (June 2019-February 2020). In this Letter, we describe the search for neutrinoless double beta decay of ^{82}Se with a total exposure (phase I+II) of 8.82 kg yr^{-1} of isotope. We set a limit on the half-life of ^{82}Se to the ground state of ^{82}Kr of T_{1/2}^{0ν}(^{82}Se)>4.6×10^{24} yr (90% credible interval), corresponding to an effective Majorana neutrino mass m_{ßß}<(263-545) meV. We also set the most stringent lower limits on the neutrinoless decays of ^{82}Se to the 0_{1}^{+}, 2_{1}^{+}, and 2_{2}^{+} excited states of ^{82}Kr, finding 1.8×10^{23} yr, 3.0×10^{23} yr, and 3.2×10^{23} yr (90% credible interval) respectively.

2.
Phys Rev Lett ; 123(3): 032501, 2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31386478

RESUMO

CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0νDBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a ^{82}Se exposure of 5.29 kg×yr. In this Letter we present the phase-I results in the search for 0νDBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: (3.5_{-0.9}^{+1.0})×10^{-3} counts/(keV kg yr). Monitoring 3.88×10^{25} ^{82}Se nuclei×yr we reach a 90% credible interval median sensitivity of T_{1/2}^{0ν}>5.0×10^{24} yr and set the most stringent limit on the half-life of ^{82}Se 0νDBD: T_{1/2}^{0ν}>3.5×10^{24} yr (90% credible interval), corresponding to m_{ßß}<(311-638) meV depending on the nuclear matrix element calculations.

3.
Phys Rev Lett ; 123(26): 262501, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31951429

RESUMO

We report on the measurement of the two-neutrino double-ß decay of ^{82}Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0 experiment. With an exposure of 9.95 kg yr of Zn^{82}Se, we determine the two-neutrino double-ß decay half-life of ^{82}Se with an unprecedented precision level, T_{1/2}^{2ν}=[8.60±0.03(stat) _{-0.13}^{+0.19}(syst)]×10^{19} yr. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such a process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5σ.

4.
Phys Rev Lett ; 120(23): 232502, 2018 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-29932707

RESUMO

We report the result of the search for neutrinoless double beta decay of ^{82}Se obtained with CUPID-0, the first large array of scintillating Zn^{82}Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr ^{82}Se exposure, and we set the most stringent lower limit on the 0νßß ^{82}Se half-life T_{1/2}^{0ν}>2.4×10^{24} yr (90% credible interval), which corresponds to an effective Majorana neutrino mass m_{ßß}<(376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of α particles and allows us to suppress the background in the region of interest down to (3.6_{-1.4}^{+1.9})×10^{-3} counts/(keV kg yr), an unprecedented level for this technique.

5.
Nat Commun ; 12(1): 2733, 2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-33980835

RESUMO

As quantum coherence times of superconducting circuits have increased from nanoseconds to hundreds of microseconds, they are currently one of the leading platforms for quantum information processing. However, coherence needs to further improve by orders of magnitude to reduce the prohibitive hardware overhead of current error correction schemes. Reaching this goal hinges on reducing the density of broken Cooper pairs, so-called quasiparticles. Here, we show that environmental radioactivity is a significant source of nonequilibrium quasiparticles. Moreover, ionizing radiation introduces time-correlated quasiparticle bursts in resonators on the same chip, further complicating quantum error correction. Operating in a deep-underground lead-shielded cryostat decreases the quasiparticle burst rate by a factor thirty and reduces dissipation up to a factor four, showcasing the importance of radiation abatement in future solid-state quantum hardware.

6.
Eur Phys J C Part Fields ; 81(8): 722, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720725

RESUMO

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of α - α delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the α decay position.

7.
Clin Microbiol Infect ; 24(1): 72-77, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28583738

RESUMO

OBJECTIVES: To evaluate predictors of mortality in patients residing in nursing-homes (NHs) or long-term care facilities (LTCFs) with diagnosis of NH-acquired pneumonia (NHAP). METHODS: We conducted an observational, prospective study (December 2013-December 2015) of patients residing in nine NHs/LTCFs of Central and Northern Italy with diagnosis of NHAP. Data on demographics, comorbidities, microbiology, and therapies were entered into an electronic database. To identify risk factors associated with 30-day mortality, we performed univariable and multivariable analyses, and predictors were internally validated using a bootstrap resampling procedure. We derived a prediction rule using the coefficients obtained from the multivariable logistic regression. The model obtained was assessed using the area under the receiver operating characteristic curve (AUROC). RESULTS: Overall, 446 patients with NHAP were included in the final cohort. The median age was 80 (IQR 75-87) years. A definite aetiology was obtained in 120 (26.9%) patients; of these, 66 (55%) had a culture positive for a multidrug-resistant pathogen. The 30-day mortality was 28.7%. On multivariate analysis, malnutrition (OR 7.8; 95% CI 3-20.2, 2 points), bilateral pneumonia (OR 3.7; 95% CI 1.4-9.8, 1 point), acute mental status deterioration (OR 6.2; 95% CI 2.2-17.6, 2 points), hypotension (OR 7.7; 95% CI 2.3-24.9, 2 points), and PaO2/FiO2 ratio ≤250 (OR 7.4; 95% CI 2.2-24.2, 2 points) were independently associated with 30-day mortality. The derived prediction rule showed an AUROC of 0.83 (95% CI 0.78-0.87, p <0.001). CONCLUSIONS: NH residents with pneumonia have specific risk factors associated with 30-day mortality. Malnutrition and acute mental change appear as major determinants of death in this population.


Assuntos
Antibacterianos/uso terapêutico , Infecção Hospitalar/tratamento farmacológico , Infecção Hospitalar/mortalidade , Farmacorresistência Bacteriana Múltipla , Pneumonia Bacteriana/tratamento farmacológico , Pneumonia Bacteriana/mortalidade , Idoso , Idoso de 80 Anos ou mais , Disfunção Cognitiva/complicações , Infecção Hospitalar/epidemiologia , Idoso Fragilizado , Humanos , Itália/epidemiologia , Assistência de Longa Duração , Desnutrição/complicações , Casas de Saúde , Pneumonia Bacteriana/epidemiologia , Estudos Prospectivos
8.
Eur Phys J C Part Fields ; 78(5): 428, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30996670

RESUMO

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of 82 Se neutrinoless double-beta decay ( 0 ν ß ß ). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0 ν ß ß at the level of 10 - 3  counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn 82 Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here.

9.
Eur Phys J C Part Fields ; 78(9): 734, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30839752

RESUMO

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn 82 Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the α background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.

10.
Eur Phys J C Part Fields ; 78(11): 888, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30881205

RESUMO

The CUPID-0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95 % enriched in 82 Se and two natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of 82 Se into the 0 1 + , 2 1 + and 2 2 + excited states of 82 Kr with an exposure of 5.74 kg · yr (2.24 × 10 25  emitters · yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: Γ ( 82 Se → 82 Kr 0 1 + )8.55 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 1 + ) < 6.25 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 2 + )8.25 × 10 - 24  yr - 1 (90 % credible interval).

11.
Eur Phys J C Part Fields ; 76(7): 364, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28280442

RESUMO

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in [Formula: see text]Se, the Zn[Formula: see text]Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn[Formula: see text]Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.

12.
Eur Phys J C Part Fields ; 75(1): 12, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25983645

RESUMO

CUORE, an array of 988 TeO[Formula: see text] bolometers, is about to be one of the most sensitive experiments searching for neutrinoless double-beta decay. Its sensitivity could be further improved by removing the background from [Formula: see text] radioactivity. A few years ago it was pointed out that the signal from [Formula: see text]s can be tagged by detecting the emitted Cherenkov light, which is not produced by [Formula: see text]s. In this paper we confirm this possibility. For the first time we measured the Cherenkov light emitted by a CUORE crystal, and found it to be 100 eV at the [Formula: see text]-value of the decay. To completely reject the [Formula: see text] background, we compute that one needs light detectors with baseline noise below 20 eV RMS, a value which is 3-4 times smaller than the average noise of the bolometric light detectors we are using. We point out that an improved light detector technology must be developed to obtain TeO[Formula: see text] bolometric experiments able to probe the inverted hierarchy of neutrino masses.

13.
Eur Phys J C Part Fields ; 75(8): 353, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26269692

RESUMO

Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10[Formula: see text]. CUORE , an array of 988 TeO[Formula: see text] bolometers being commissioned at Laboratori Nazionali del Gran Sasso, features an expected sensitivity of 50-130[Formula: see text] at 90 % C.L. The background is expected to be dominated by [Formula: see text] radioactivity, and can be in principle removed by detecting the small amount of Cherenkov  light emitted by the [Formula: see text] signal. The Cryogenic wide-Area Light Detectors with Excellent Resolution project aims at developing a small prototype experiment consisting of TeO[Formula: see text] bolometers coupled to high-sensitivity light detectors based on kinetic inductance detectors. The R&D is focused on the light detectors in view of the implementation in a next-generation neutrinoless double-beta decay experiment.

14.
Artigo em Inglês | MEDLINE | ID: mdl-26705394

RESUMO

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of [Formula: see text]Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched [Formula: see text]Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched [Formula: see text]Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of [Formula: see text]Th, [Formula: see text]U and [Formula: see text]U are respectively: [Formula: see text]61, [Formula: see text]110 and [Formula: see text]74 [Formula: see text]Bq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the [Formula: see text]Se allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of [Formula: see text]Se to 0[Formula: see text], 2[Formula: see text] and 2[Formula: see text] excited states of [Formula: see text]Kr of 3.4[Formula: see text]10[Formula: see text], 1.3[Formula: see text]10[Formula: see text] and 1.0[Formula: see text]10[Formula: see text] y, respectively, with a 90 % C.L.

15.
Environ Health Perspect ; 105 Suppl 6: 1569-73, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9467084

RESUMO

Many epidemiologic studies suggest a relationship between incidence of diseases like cancer and leukemia and exposure to 50/60 Hz magnetic fields. Some studies suggest a relationship between leukemia incidence in populations residing near high-voltage lines and the distance to these lines. Other epidemiologic studies suggest a relationship between leukemia incidence and exposure to 50/60 Hz magnetic fields (measured or estimated) and distance from the main system (220 or 120 V). The present work does not question these results but is intended to draw attention to a possible concurrent cause that might also increase the incidence of this disease; the presence on an electric grid of radiofrequency currents used for communications and remote control. These currents have been detected on high- and medium-voltage lines. In some cases they are even used on the main system for remote reading of electric meters. This implies that radiofrequency (RF) magnetic fields are present near the electric network in addition to the 50/60 Hz fields. This intensity of these RF fields is low but the intensity of currents induced in the human body by exposure to magnetic fields increases with frequency. Because scientific research has not yet clarified whether the risk is related to the value of magnetic induction or to the currents this kind of exposure produces in the human body, it is reasonable to suggest that the presence of the RF magnetic fields must be considered in the context of epidemiologic studies.


Assuntos
Exposição Ambiental , Ondas de Rádio , Eletrofisiologia , Humanos , Itália , Músculo Esquelético/efeitos da radiação , Suécia
16.
Ann Ist Super Sanita ; 30(1): 109-18, 1994.
Artigo em Italiano | MEDLINE | ID: mdl-7832392

RESUMO

Some practical items, concerning the safety of workers employed in clinical NMR sites are described. In particular, the connections between safety, and arrangement of some installations, like electric system and cryogenic system, are pointed out. The consideration of the physical properties of the cryogens used in such sites can determine different designing criteria of these plants. Furthermore, the connections among properties of cryogens, characteristics of electric system, and prevention of fire are considered.


Assuntos
Ocupações em Saúde , Espectroscopia de Ressonância Magnética , Segurança , Humanos , Fenômenos Físicos , Física
17.
Pediatr Med Chir ; 10(5): 489-92, 1988.
Artigo em Italiano | MEDLINE | ID: mdl-2977222

RESUMO

In this study we have tried to examine retrospectively all the babies born to HBsAg + mothers in the past nine years, in order to evaluate which is the real incidence of perinatal transmission of HBsAg, and then if the actual politic to vaccinate only these babies is right and sufficient. The results demonstrate that the perinatal transmission is not a major problem in our country, so we suggest that for improvement of public health is more advised the vaccination of all infants: those born to HBsAg + mothers at the birth, the others in the third month of life.


Assuntos
Antígenos de Superfície da Hepatite B/imunologia , Hepatite B/transmissão , Vacinas contra Hepatite Viral , Adulto , Feminino , Hepatite B/imunologia , Hepatite B/prevenção & controle , Vacinas contra Hepatite B , Humanos , Recém-Nascido , Estudos Retrospectivos
18.
Electrophoresis ; 19(10): 1631-41, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9719538

RESUMO

We describe a new protocol for denaturant gradient gel electrophoresis, namely the migration of proteins across transverse sodium dodecyl sulfate (SDS)-gradients. We show how such gradients may be reproducibly cast, and demonstrate their stability with time once an appropriate SDS reservoir is arranged at the cathode. SDS affects both size and surface charge of the molecules, and influences the secondary and tertiary structure to a variable extent, even in opposite directions. Hence, distinct, sometimes complex, denaturation patterns may be observed for different proteins.


Assuntos
Eletroforese/métodos , Proteínas/análise , Dodecilsulfato de Sódio , Dicroísmo Circular , Cinética , Muramidase/análise , Desnaturação Proteica
19.
Electrophoresis ; 19(8-9): 1484-92, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9694300

RESUMO

In the present investigation, we have identified 56 major spots, or spot rows, corresponding to 22 proteins, in the 2-DE pattern of adult male rats. This was done mainly by applying two complementary techniques, namely immunoblotting and high performance liquid chromatography-mass spectrometry (HPLC-MS) peptide mapping. Glycoproteins were characterized by affinity blotting with six lectins. We have also detailed how rat serum differs from human serum in two main respects: (i) relative abundance of individual proteins, which amounts in some cases to a complete absence in either sample, and (ii) varying molecular parameters for homologous proteins. It was thus possible to establish a first-generation reference map of rat serum proteins, which can be accessed through http://weber.u.washington.edu/ruedilab/aebersold++ +.html. We hope the present database will be a useful reference for the evaluation of changes in serum protein distribution in the course of pharmacological and toxicological studies. The recognition of species-specific proteins appears of special relevance in this respect.


Assuntos
Proteínas Sanguíneas/normas , Cromatografia Líquida de Alta Pressão , Eletroforese em Gel Bidimensional , Immunoblotting , Mapeamento de Peptídeos/métodos , Animais , Proteínas Sanguíneas/análise , Humanos , Masculino , Espectrometria de Massas , Camundongos , Ratos , Ratos Sprague-Dawley , Padrões de Referência
20.
Electrophoresis ; 19(8-9): 1493-500, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9694301

RESUMO

This report complements the database already detailed for serum proteins of healthy adult male rats (P. Haynes et al., Electrophoresis 1998, 19, 1484-1492). The influence on the two-dimensional electrophoresis (2-DE) pattern of certain physiological conditions (sex, age) was studied as well as of changes in thyroid metabolism. We have extended the information about the major components of rat serum by identifying the proteins typical for the response to acute inflammation. Analyzing 27 spots, six proteins not found in control sera could be recognized; migration at overlapping or close positions with five already characterized proteins was observed for some. A compilation of all our rat data can be accessed through: http://weber.u.washington.edu/ruedilab/ aebersold.html.


Assuntos
Proteínas Sanguíneas/análise , Eletroforese em Gel Bidimensional , Animais , Eletroforese em Gel Bidimensional/métodos , Feminino , Masculino , Ratos , Ratos Sprague-Dawley , Caracteres Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA