Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País/Região como assunto
Intervalo de ano de publicação
1.
Phys Rev Lett ; 103(14): 142501, 2009 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-19905565

RESUMO

We report the first confirmation of the predicted inversion between the pi2p3/2 and pi1f5/2 nuclear states in the nu(g)9/2 midshell. This was achieved at the ISOLDE facility, by using a combination of in-source laser spectroscopy and collinear laser spectroscopy on the ground states of 71,73,75Cu, which measured the nuclear spin and magnetic moments. The obtained values are mu(71Cu)=+2.2747(8)mu(N), mu(73Cu)=+1.7426(8)mu(N), and mu(75Cu)=+1.0062(13)mu(N) corresponding to spins I=3/2 for 71,73Cu and I=5/2 for 75Cu. The results are in fair agreement with large-scale shell-model calculations.

2.
Rev Sci Instrum ; 86(12): 123510, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26724030

RESUMO

The high current cyclotron C-80 capable of producing 40-80 MeV proton beams with a current of up to 200 µA has been constructed at Petersburg Nuclear Physics Institute. One of the main goals of the C-80 is the production of a wide spectrum of medical radionuclides for diagnostics and therapy. The project development of the radioisotope complex RIC-80 (radioisotopes at the cyclotron C-80) at the beam of C-80 has been completed. The RIC-80 complex is briefly discussed in this paper. The combination of the mass-separator with the target-ion source device, available at one of the new target stations for on-line or semi on-line production of a high purity separated radioisotopes, is explored in greater detail. The results of target and ion source tests for a mass-separator method for the production of high purity radioisotopes (82)Sr and (223,224)Ra are also presented.


Assuntos
Ciclotrons/instrumentação , Marcação por Isótopo/instrumentação , Física Nuclear/instrumentação , Radioisótopos/isolamento & purificação , Geradores de Radionuclídeos/instrumentação , Academias e Institutos , Desenho de Equipamento , Radioisótopos/química , Federação Russa
3.
Rev Sci Instrum ; 83(2): 02B306, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380285

RESUMO

New laser installation for the resonance ionization spectroscopy in a laser ion source and for rare isotope production has been recently put into operation at the IRIS (Investigation of Radioactive Isotopes on Synchrocyclotron) facility (Petersburg Nuclear Physics Institute, Gatchina). This is a significant improvement of a previous target-laser ion source device of the IRIS mass-separator, working on-line with 1 GeV proton beam of PNPI (Petersburg Nuclear Physics Institute) synchrocyclotron. It makes possible for us to get the isobarically clean radioactive isotope beams of a great number of chemical elements. New laser setup provides the two- or three-resonance step ionization in the range of wavelength of 265-850 nm. The first results obtained at the laser setup for Tl isotopes are presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA