Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Diagn Interv Imaging ; 101(5): 289-297, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31932228

RESUMO

PURPOSE: To determine the lowest suitable dose level for the detection of pulmonary arteriovenous malformation (PAVM) using a task-based image quality assessment. MATERIAL AND METHODS: A phantom was scanned using the standard chest protocol (STD) and 4 other ultra-low dose protocols (ULD) using various kVp. Raw data were reconstructed using level 5 of the hybrid iterative reconstruction algorithm (iDose4) for the STD protocol, and level 6 of iDose4 and levels 1 to 3 of model-based iterative reconstruction (IMR) for the ULD protocols. Both quantitative criteria and qualitative analysis were used to compare protocols. Noise-power-spectrum and Task-based transfer function were computed using imQuest software. The detectability-index (d') was computed for the detection of PAVM. A subjective analysis was performed by 2 chest radiologists to validate the image-quality obtained on the anthropomorphic phantom for all protocols. RESULTS: Similar d' values were found for ULD-140 using iDose4 6 compared to STD protocol. Greater d' values were found for all ULD protocols using IMR compared to STD. Subjective image quality was rated as acceptable to excellent for ULD-140 and ULD-120 for all reconstruction types, for ULD-100 and ULD-80 using IMR2, and for ULD-100 using IMR1. Image smoothing was poor for IMR3 for ULD-100 and ULD-80. Finally, the ULD-80 protocol reconstructed with IMR2 was chosen for the detection of PAVM. With this protocol, the dose (CTDIvol of 0.3mGy) was reduced by 91% compared with the STD protocol. CONCLUSION: A dose level as low as 0.3mGy reconstructed with IMR2 provides an image quality suitable for the detection of PAVM.


Assuntos
Malformações Arteriovenosas , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Malformações Arteriovenosas/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
2.
Diagn Interv Imaging ; 99(7-8): 483-492, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29452852

RESUMO

PURPOSE: To evaluate the radiation dose reduction, image quality and diagnostic confidence with thoraco-abdominopelvic computed tomography (TACT) using a new organ based dose modulation system (liver dose right index [Liver DRI]), compared to TACT using a standard automatic exposure control adjusting mA according to attenuation. METHODS: A total of 37 patients who had two TACT examinations on 2 different CT scanners, one using standard automatic exposure control (combination of a DoseRight automatic current selection and Z modulation) and one using Liver DRI were included. There were 19 men and 18 women with a mean age of 67.6±11.7 (SD) years (range: 36-85 years) For each patient, volume CT dose index (CTDIvol), size-specific dose estimates (SSDE) and signal-to-noise ratio (SNR) were evaluated at each anatomic level (lung, breast, liver and pelvis area) for each protocol. Two radiologists assessed independently image quality, artifacts and diagnostic confidence. RESULTS: The radiation dose decreased significantly using Liver DRI compared to standard automatic exposure control on the total scan length, lung, breast and pelvis area, with a significant CTDIvol reduction of 27% (P=0.0001), 23% (P=0.0002), 24% (P=0.0002) and 31% (P=0.0001), respectively; and a significant SSDE reduction of 23% (P=0.0001), 28% (P=0.0001), 23% (P=0.0002) and 29% (P=0.0001), respectively. No significant SNR reductions were observed in all measured tissues at the level of the aortic arch, celiac trunk and iliac bifurcation, except in the muscle (P=0.0013) and fat tissue (P=0.0052) at the level of the ureteral meatus. No significant differences were noted between both protocols in overall image quality, artifacts and diagnostic confidence with an excellent inter observer agreement between radiologists (Kappa values of 0.83, 0.85 and 0.88, respectively). CONCLUSION: Liver DRI organ based dose modulation technique allows significant dose reduction compared to standard automatic exposure control while preserving diagnostic image quality in all thoraco-abdominopelvic areas.


Assuntos
Abdome/diagnóstico por imagem , Fígado/diagnóstico por imagem , Pelve/diagnóstico por imagem , Doses de Radiação , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA