Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Pediatr Radiol ; 54(6): 965-976, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38609702

RESUMO

BACKGROUND: Congenital mesoblastic nephroma is the most common solid renal tumor in neonates. Therefore, patients <3 months of age are advised to undergo upfront nephrectomy, whereas invasive procedures at diagnosis in patients ≥3 months of age are discouraged by the International Society of Pediatric Oncology-Renal Tumor Study Group (SIOP-RTSG). Nevertheless, discriminating congenital mesoblastic nephroma, especially from the more common Wilms tumor, solely based on imaging remains difficult. Recently, magnetic resonance imaging (MRI) has become the preferred modality. Studies focusing on MRI characteristics of congenital mesoblastic nephroma are limited. OBJECTIVE: This study aims to identify diagnostic MRI characteristics of congenital mesoblastic nephroma in the largest series of patients to date. MATERIALS AND METHODS: In this retrospective multicenter study, five SIOP-RTSG national review radiologists identified 52 diagnostic MRIs of histologically proven congenital mesoblastic nephromas. MRI was performed following SIOP-RTSG protocols, while radiologists assessed their national cases using a validated case report form. RESULTS: Patients (24/52 classic, 11/52 cellular, and 15/52 mixed type congenital mesoblastic nephroma, 2/52 unknown) had a median age of 1 month (range 1 day-3 months). Classic type congenital mesoblastic nephroma appeared homogeneous with a lack of hemorrhage, necrosis and/or cysts, showing a concentric ring sign in 14 (58.3%) patients. Cellular and mixed type congenital mesoblastic nephroma appeared more heterogeneous and were larger (311.6 and 174.2 cm3, respectively, versus 41.0 cm3 for the classic type (P<0.001)). All cases were predominantly T2-weighted isointense and T1-weighted hypointense, and mean overall apparent diffusion coefficient values ranged from 1.05-1.10×10-3 mm2/s. CONCLUSION: This retrospective international collaborative study showed classic type congenital mesoblastic nephroma predominantly presented as a homogeneous T2-weighted isointense mass with a typical concentric ring sign, whereas the cellular type appeared more heterogeneous. Future studies may use identified MRI characteristic of congenital mesoblastic nephroma for validation and for exploring the discriminative non-invasive value of MRI, especially from Wilms tumor.


Assuntos
Neoplasias Renais , Imageamento por Ressonância Magnética , Nefroma Mesoblástico , Humanos , Nefroma Mesoblástico/diagnóstico por imagem , Estudos Retrospectivos , Neoplasias Renais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Lactente , Masculino , Feminino , Recém-Nascido , Diagnóstico Diferencial
2.
BMC Biol ; 20(1): 14, 2022 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-35027054

RESUMO

BACKGROUND: Infectious diseases of farmed and wild animals pose a recurrent threat to food security and human health. The macrophage, a key component of the innate immune system, is the first line of defence against many infectious agents and plays a major role in shaping the adaptive immune response. However, this phagocyte is a target and host for many pathogens. Understanding the molecular basis of interactions between macrophages and pathogens is therefore crucial for the development of effective strategies to combat important infectious diseases. RESULTS: We explored how porcine pluripotent stem cells (PSCs) can provide a limitless in vitro supply of genetically and experimentally tractable macrophages. Porcine PSC-derived macrophages (PSCdMs) exhibited molecular and functional characteristics of ex vivo primary macrophages and were productively infected by pig pathogens, including porcine reproductive and respiratory syndrome virus (PRRSV) and African swine fever virus (ASFV), two of the most economically important and devastating viruses in pig farming. Moreover, porcine PSCdMs were readily amenable to genetic modification by CRISPR/Cas9 gene editing applied either in parental stem cells or directly in the macrophages by lentiviral vector transduction. CONCLUSIONS: We show that porcine PSCdMs exhibit key macrophage characteristics, including infection by a range of commercially relevant pig pathogens. In addition, genetic engineering of PSCs and PSCdMs affords new opportunities for functional analysis of macrophage biology in an important livestock species. PSCs and differentiated derivatives should therefore represent a useful and ethical experimental platform to investigate the genetic and molecular basis of host-pathogen interactions in pigs, and also have wider applications in livestock.


Assuntos
Vírus da Febre Suína Africana , Doenças Transmissíveis , Vírus da Febre Suína Africana/genética , Animais , Interações Hospedeiro-Patógeno/genética , Macrófagos , Células-Tronco , Suínos
3.
Radiology ; 303(1): 173-181, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34874199

RESUMO

Background Children with pediatric inflammatory syndrome temporally associated with SARS-CoV-2 (PIMS-TS), also known as multisystem inflammatory syndrome in children, present with abdominal pain among other nonspecific symptoms. Although initial imaging features of PIMS-TS have been reported, the duration of sonographic features remains unknown. Purpose To describe the abdominal US features of PIMS-TS at initial presentation and follow-up. Materials and Methods A retrospective review of children and young adults presenting with clinical features suspicious for PIMS-TS between April 2020 and June 2021 was carried out. US features were documented and reviewed at initial presentation and follow-up. Descriptive statistics were used and interobserver variability was calculated. Results Of 140 children and young adults presenting with suspected PIMS-TS, 120 had confirmed PIMS-TS (median age, 9 years; interquartile range, 7-12 years; 65 male patients) and 102 underwent abdominal US at presentation. PIMS-TS was present as a single abnormality in 109 of the 120 patients (91%) and abdominal symptoms were present in 104 of the 109 (95%). US examinations were abnormal in 86 of 102 patients (84%), with ascites being the most common abnormality in 65 (64%; 95% CI: 54, 73). Bowel wall thickening was present at US in 14 of the 102 patients (14%; 95% CI: 7, 20) and mesenteric inflammation was present in 16 (16%; 95% CI: 9, 23); all of these patients presented with abdominal symptoms. Among the patients with bowel wall thickening, the distal and terminal ileum were most involved (eight of 14 patients, 57%). Abdominal symptoms decreased to seven of 56 patients (13%) in those followed up at 6 months. Thirty-eight patients underwent follow-up US, and the presence of bowel inflammation had decreased to three of 27 patients (11%; 95% CI: -1, 23) in those followed up for less than 2 months and 0 of 17 (0%) in those followed up for more than 2 months. Conclusion Of 102 patients with pediatric inflammatory multisystem syndrome temporally associated with SARS-CoV-2 who underwent US at presentation, 14 (14%) had abdominal US findings of bowel inflammation and 16 (16%) had mesenteric edema. All US abnormalities resolved after 2 months. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by van Rijn and Pajkrt in this issue.


Assuntos
COVID-19 , COVID-19/complicações , COVID-19/diagnóstico por imagem , Criança , Humanos , Masculino , Estudos Retrospectivos , SARS-CoV-2 , Síndrome de Resposta Inflamatória Sistêmica/complicações , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico por imagem
4.
J Magn Reson Imaging ; 55(2): 543-552, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34363274

RESUMO

BACKGROUND: The SIOP-Renal Tumor Study Group (RTSG) does not advocate invasive procedures to determine histology before the start of therapy. This may induce misdiagnosis-based treatment initiation, but only for a relatively small percentage of approximately 10% of non-Wilms tumors (non-WTs). MRI could be useful for reducing misdiagnosis, but there is no global consensus on differentiating characteristics. PURPOSE: To identify MRI characteristics that may be used for discrimination of newly diagnosed pediatric renal tumors. STUDY TYPE: Consensus process using a Delphi method. POPULATION: Not applicable. FIELD STRENGTH/SEQUENCE: Abdominal MRI including T1- and T2-weighted imaging, contrast-enhanced MRI, and diffusion-weighted imaging at 1.5 or 3 T. ASSESSMENT: Twenty-three radiologists from the SIOP-RTSG radiology panel with ≥5 years of experience in MRI of pediatric renal tumors and/or who had assessed ≥50 MRI scans of pediatric renal tumors in the past 5 years identified potentially discriminatory characteristics in the first questionnaire. These characteristics were scored in the subsequent second round, consisting of 5-point Likert scales, ranking- and multiple choice questions. STATISTICAL TESTS: The cut-off value for consensus and agreement among the majority was ≥75% and ≥60%, respectively, with a median of ≥4 on the Likert scale. RESULTS: Consensus on specific characteristics mainly concerned the discrimination between WTs and non-WTs, and WTs and nephrogenic rest(s) (NR)/nephroblastomatosis. The presence of bilateral lesions (75.0%) and NR/nephroblastomatosis (65.0%) were MRI characteristics indicated as specific for the diagnosis of a WT, and 91.3% of the participants agreed that MRI is useful to distinguish NR/nephroblastomatosis from WT. Furthermore, all participants agreed that age influenced their prediction in the discrimination of pediatric renal tumors. DATA CONCLUSION: Although the discrimination of pediatric renal tumors based on MRI remains challenging, this study identified some specific characteristics for tumor subtypes, based on the shared opinion of experts. These results may guide future validation studies and innovative efforts. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 3.


Assuntos
Neoplasias Renais , Radiologia , Tumor de Wilms , Técnica Delphi , Imagem de Difusão por Ressonância Magnética , Humanos , Neoplasias Renais/diagnóstico por imagem
5.
Eur Radiol ; 31(2): 775-784, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32833090

RESUMO

OBJECTIVES: Investigate the relationship between quantified terminal ileal (TI) motility and histopathological activity grading, Crohn Disease MRI Index (CDMI) and faecal calprotectin. METHODS: Retrospective review of children with Crohn disease or unclassified inflammatory bowel disease, who underwent MR enterography. Dynamic imaging for 25 patients (median age 12, range 5 to 16) was analysed with a validated motility algorithm. The TI motility score was derived. The primary reference standard was TI Endoscopic biopsy Assessment of Inflammatory Activity (eAIS) within 40 days of the MR enterography. Secondary reference standards: (1) the Crohn Disease MRI Index (CDMI) and (2) faecal calprotectin levels. RESULTS: MR enterography median motility score was 0.17 a.u. (IQR 0.12 to 0.25; range 0.05 to 0.55), and median CDMI was 3 (IQR 0 to 5.5). Forty-three percent of patients had active disease (eAIS > 0) with a median eAIS score of 0 (IQR 0 to 2; range 0 to 5). The correlation between eAIS and motility was r = - 0.58 (p = 0.004, N = 23). Between CDMI and motility, r = - 0.42 (p = 0.037, N = 25). Motility score was lower in active disease (median 0.12 vs 0.21, p = 0.020) while CDMI was higher (median 5 vs 1, p = 0.04). In a subset of 12 patients with faecal calprotectin within 3 months of MR enterography, correlation with motility was r = - 0.27 (p = 0.4). CONCLUSIONS: Quantified terminal ileum motility decreases with increasing histopathological abnormality in children with Crohn disease, reproducing findings in adults. TI motility showed a negative correlation with an MRI activity score but not with faecal calprotectin levels. KEY POINTS: • It is feasible to perform MRI quantified bowel motility assessment in children using free-breathing techniques. • Bowel motility in children with Crohn disease decreases as the extent of intestinal inflammation increases. • Quantified intestinal motility may be a candidate biomarker for treatment efficacy in children with Crohn disease.


Assuntos
Doença de Crohn , Adulto , Criança , Doença de Crohn/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Íleo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Retrospectivos
6.
Pediatr Radiol ; 51(4): 554-569, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33743039

RESUMO

We present the case for subspecialisation in paediatric gastrointestinal and hepato-pancreatico-biliary radiology. We frame the discussion around a number of questions: What is different about the paediatric patient and paediatric gastrointestinal system? What does the radiologist need to do differently? And finally, what can be translated from these subspecialty areas into everyday practice? We cover conditions that the sub-specialist might encounter, focusing on entities such as inflammatory bowel disease and hepatic vascular anomalies. We also highlight novel imaging techniques that are a focus of research in the subspecialties, including contrast-enhanced ultrasound, MRI motility, magnetisation transfer factor, and magnetic resonance elastography.


Assuntos
Radiologia , Criança , Humanos , Imageamento por Ressonância Magnética , Radiografia , Radiologistas , Ultrassonografia
7.
Pediatr Radiol ; 49(6): 777-783, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30868197

RESUMO

BACKGROUND: The usefulness of acoustic shadowing as a feature of pediatric kidney stone ultrasound (US) may be underestimated. OBJECTIVE: The hypothesis was that the majority of stones in children have acoustic shadowing and that its specificity is high (>90%) in pediatric kidney stones. MATERIALS AND METHODS: Our retrospective observational study included children who had undergone abdominal non-enhanced computed tomography (CT) for kidney stones in a pediatric renal stone referral centre between 2015 and 2016. US examinations prior to CT were retrospectively assessed for US features such as acoustic shadowing, twinkle artifact and stone size. These features were compared to CT as reference standard. RESULTS: Thirty-one patients (median age: 13 years, range: 1-17 years) with 77 suspected kidney stones were included. The median stone size was 5 mm (interquartile range [IQR]: 5 mm). For acoustic shadowing, sensitivity was 70% (95% confidence interval [CI] 56-80%) and specificity was 100% (95% CI 56-100%). All kidney stones with a diameter ≥9 mm demonstrated shadowing. Sensitivity for twinkle artifact was 88% (95% CI 72-96%), but specificity for twinkle artifact could not be calculated due to the lack of true negatives. All false-positive stones on US demonstrated twinkle artifact, but none showed shadowing. CONCLUSION: Acoustic shadowing was demonstrated in the majority of pediatric kidney stones. Specificity was high, but this was not significant. Twinkle artifact is a sensitive US tool for detecting (pediatric) kidney calculi, but with a risk of false-positive findings.


Assuntos
Cálculos Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Adolescente , Artefatos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Pediatr Radiol ; 49(6): 841-848, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30915515

RESUMO

Very early onset inflammatory bowel disease (VEO-IBD) is defined as disease presenting before the age of 6. These children require a tailored imaging approach because conventional imaging studies can be difficult to perform at such a young age. Unlike inflammatory bowel disease in older children and adults, colonic disease predominates in VEO-IBD, and small-bowel disease is rare. Distinguishing Crohn disease from ulcerative colitis is challenging both clinically and on histology. Radiology offers the greatest utility for detecting small-bowel disease because it helps to distinguish the two main disease entities and guide clinical management. Small-bowel ultrasound is recommended as the first-line investigation because it requires relatively little preparation, is readily available and is generally well tolerated in young children. We present these recommendations, based on the current evidence for radiologic management in this group, and propose an imaging algorithm for investigating VEO-IBD.


Assuntos
Doenças Inflamatórias Intestinais/diagnóstico por imagem , Algoritmos , Criança , Diagnóstico Diferencial , Europa (Continente) , Feminino , Humanos , Masculino
10.
AAPS PharmSciTech ; 21(1): 2, 2019 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-31713019

RESUMO

The abuse of prescription opioid drugs is a well-documented and very serious problem. One of the typical first steps an abuser will take is to manipulate a tablet into to a fine powder. To deter this behavior, formulators use crush-resistant technologies like polyethylene oxide (PEO). When heat-treated, PEO creates a hard, flexible tablet that cannot be easily ground down into a fine powder. We investigated the effects of PEO molecular weight (MW), annealing temperature, and annealing time on tablet compression deformation behavior and fracture resistance. These tests were designed to represent an abuser's attempt to smash and grind a tablet, respectively. Annealing temperatures above the melting point of PEO showed the most improvement in mechanical properties compared with that in unannealed tablets. The minimum annealing time was dependent on the polymer MW and annealing temperature. Tablets were manipulated using a coffee grinder, and the particle size of the resulting powders was measured. The particle size correlated well with fracture toughness, demonstrating that increasing fracture toughness increases the manipulation resistance of a PEO tablet.


Assuntos
Polietilenoglicóis/química , Transtornos Relacionados ao Uso de Substâncias/prevenção & controle , Comprimidos , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/química , Composição de Medicamentos , Excipientes , Testes de Dureza , Temperatura Alta , Peso Molecular , Tamanho da Partícula , Solubilidade , Temperatura
11.
Transp Res Part A Policy Pract ; 128: 149-159, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31582879

RESUMO

BACKGROUND: Planners and politicians in many countries seek to increase the proportion of trips made by cycling. However, this is often challenging. In England, a national target to double cycling by 2025 is likely to be missed: between 2001 and 2011 the proportion of commutes made by cycling barely grew. One important contributory factor is continued low investment in cycling infrastructure, by comparison to European leaders. METHODS: This paper examines barriers to cycling investment, considering that these need to be better understood to understand failures to increase cycling level. It is based on qualitative data from an online survey of over 400 stakeholders, alongside seven in-depth interviews. RESULTS: Many respondents reported that change continues to be blocked by chronic barriers including a lack of funding and leadership. Participants provided insights into how challenges develop along the life of a scheme. In authorities with little consideration given to cycling provision, media and public opposition were not reported as a major issue. However, where planning and implementation have begun, this can change quickly; although examples were given of schemes successfully proceeding, despite this. The research points to a growing gap between authorities that have overcome key challenges, and those that have not.

12.
Nephrol Dial Transplant ; 33(10): 1863-1869, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29757424

RESUMO

Background: Current reliance on clinical, laboratory and Doppler ultrasound (DUS) parameters for monitoring kidney transplant perfusion in the immediate post-operative period in children risks late recognition of allograft hypoperfusion and vascular complications. Near-infrared spectroscopy (NIRS) is a real-time, non-invasive technique for monitoring tissue oxygenation percutaneously. NIRS monitoring of kidney transplant perfusion has not previously been validated to the gold standard of DUS. We examined whether NIRS tissue oxygenation indices can reliably assess blood flow in established paediatric kidney transplants. Methods: Paediatric kidney transplant recipients ages 1-18 years with stable allograft function were eligible. Participants underwent routine DUS assessment of kidney transplant perfusion, including resistive index (RI) and peak systolic velocity at the upper and lower poles. NIRS data [tissue oxygenation index (TOI%)] were recorded for a minimum of 2 min with NIRS sensors placed on the skin over upper and lower allograft poles. Results: Twenty-nine subjects with a median age of 13.3 (range 4.8-17.8) years and a median transplant vintage of 26.5 months participated. Thirteen (45%) were female and 20 (69%) were living donor kidney recipients. NIRS monitoring was well tolerated by all, with 96-100% valid measurements. Significant negative correlations were observed between NIRS TOI% and DUS RI at both the upper and lower poles (r = -0.4 and -0.6, P = 0.04 and 0.001, respectively). Systolic blood pressure but not estimated glomerular filtration rate also correlated with NIRS TOI% (P = 0.01). Conclusions: NIRS indices correlate well with DUS perfusion and haemodynamic parameters in established paediatric kidney transplant recipients. Further studies are warranted to extend NIRS use for continuous real-time monitoring of early post-transplant perfusion status.


Assuntos
Transplante de Rim/métodos , Rim/fisiopatologia , Monitorização Fisiológica/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Taxa de Filtração Glomerular , Humanos , Lactente , Rim/diagnóstico por imagem , Testes de Função Renal , Masculino , Período Pós-Operatório , Circulação Renal , Ultrassonografia
13.
Pediatr Radiol ; 48(6): 843-851, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29651607

RESUMO

BACKGROUND: Magnetic resonance enterography (MRE) is the current gold standard for imaging in inflammatory bowel disease, but ultrasound (US) is a potential alternative. OBJECTIVE: To determine whether US is as good as MRE for the detecting inflamed bowel, using a combined consensus score as the reference standard. MATERIALS AND METHODS: We conducted a retrospective cohort study in children and adolescents <18 years with inflammatory bowel disease (IBD) at a tertiary and quaternary centre. We included children who underwent MRE and US within 4 weeks. We scored MRE using the London score and US using a score adapted from the METRIC (MR Enterography or Ultrasound in Crohn's Disease) trial. Four gastroenterologists assessed an independent clinical consensus score. A combined consensus score using the imaging and clinical scores was agreed upon and used as the reference standard to compare MRE with US. RESULTS: We included 53 children. At a whole-patient level, MRE scores were 2% higher than US scores. We used Lin coefficient to assess inter-observer variability. The repeatability of MRE scores was poor (Lin 0.6). Agreement for US scoring was substantial (Lin 0.95). There was a significant positive correlation between MRE and clinical consensus scores (Spearman's rho = 0.598, P=0.0053) and US and clinical consensus scores (Spearman's rho = 0.657, P=0.0016). CONCLUSION: US detects as much clinically significant bowel disease as MRE. It is possible that MRE overestimates the presence of disease when using a scoring system. This study demonstrates the feasibility of using a clinical consensus reference standard in paediatric IBD imaging studies.


Assuntos
Doenças Inflamatórias Intestinais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Adolescente , Criança , Feminino , Humanos , Doenças Inflamatórias Intestinais/patologia , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
Pediatr Radiol ; 47(7): 877-883, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28386628

RESUMO

MR enterography is the accepted imaging reference standard for small bowel assessment in inflammatory bowel disease. There is an increasing cohort of children with inflammatory bowel disease presenting at an early age (<5 years) with severe disease. Younger children present a technical challenge for enterography because of the need for sedation/general anaesthesia to allow image optimisation and the need for oral contrast to allow adequate luminal assessment. Through our experiences, MR enteroclysis under general anaesthesia has proven to be a successful imaging technique for the work-up of these patients. In this paper, we present our institutional practice for performing MR enteroclysis under general anaesthesia.


Assuntos
Anestesia Geral , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Criança , Pré-Escolar , Meios de Contraste , Feminino , Fluoroscopia , Humanos , Lactente , Masculino
17.
Pediatr Radiol ; 46(5): 646-52, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26867608

RESUMO

BACKGROUND: Pediatric inflammatory bowel disease frequently affects the colon. MR enterography is used to assess the small bowel but it also depicts the colon. OBJECTIVE: To compare the accuracy of MR enterography and direct visualization at endoscopy in assessing the colon in pediatric inflammatory bowel disease. MATERIALS AND METHODS: We included children with inflammatory bowel disease who had undergone both MR enterography and endoscopy, and we restrospectively assessed the imaging and endoscopic findings. We scored the colonic appearance at MR using a total colon score. We then compared scores for the whole colon and for its individual segments with endoscopy and histology. RESULTS: We included 15 children. An elevated MR colonic segmental score predicted the presence of active inflammation on biopsy with a specificity of 90% (95% confidence interval [CI] 79.5-96.2%) and sensitivity of 60% (CI 40.6-77.3%); this compares reasonably with the predictive values for findings at colonoscopy - specificity 85% (CI 73.4-92.9%) and sensitivity 53.3% (CI 34.3%-71.6%). Accuracy did not change significantly with increasing bowel distension. CONCLUSION: MR-derived scores had comparable accuracy to those derived during visualization at colonoscopy for detecting biopsy-proven inflammation in our patient group. MR enterography might prove useful in guiding biopsy or monitoring treatment response. Collapse of a colonic segment did not impair assessment of inflammation.


Assuntos
Doenças Inflamatórias Intestinais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Biópsia , Criança , Pré-Escolar , Colonoscopia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
J Pediatr Gastroenterol Nutr ; 61(2): 253-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25688480

RESUMO

OBJECTIVE: The aetiology of biliary liver disease in children with intestinal failure treated with long-term parenteral nutrition (PN) is multifactorial. Risks include the lipid component of PN. The aim of the study was to compare prevalence and outcome of gallstones with different types of intravenous lipids. METHODS: Liver and biliary tract imaging and relevant clinical details were reviewed in 71 patients (37, 52% boys) treated with PN for >3 months. Types of lipid infused were compared with regard to hepatobiliary abnormalities. RESULTS: In total 369 abdominal ultrasounds were performed in 71 patients of age between 3 months and 17 years. Underlying diagnoses were short bowel syndrome in 20 (28%), small intestinal enteropathy in 34 (48%), and motility disorder in 17 (24%). A total of 67 (94%) children had 362/369 scans on lipid-containing PN. Of the total, 15 (21%) patients had gallstones, 8 (11%) had sludge, and both were detected in 7 (10%) children. The gallstones/sludge resolved in 7 patients (10%) and persisted in 10 (13%). In 6 patients, sludge progressed to form discrete gallstones, and in 9 children, gallstones led to biliary duct dilatation. Four (6%) patients underwent cholecystectomy. Fewer children had abnormalities with the newer mixed lipid emulsion (P = 0.005). There was a higher prevalence of sludge (P = 0.01) on pure soya lipid. Predictors for sludge were young age at PN (P = 0.001), lack of enteral feed (P < 0.001), and motility disorder with stoma (P = 0.002). CONCLUSIONS: Hepatobiliary pathology is common in children on PN. The use of mixed lipid was associated with less biliary complications and should be the first choice of treatment in children.


Assuntos
Emulsões Gordurosas Intravenosas/administração & dosagem , Cálculos Biliares/epidemiologia , Enteropatias/terapia , Nutrição Parenteral/efeitos adversos , Adolescente , Bile/diagnóstico por imagem , Doenças Biliares/diagnóstico por imagem , Doenças Biliares/epidemiologia , Criança , Pré-Escolar , Emulsões Gordurosas Intravenosas/efeitos adversos , Emulsões Gordurosas Intravenosas/uso terapêutico , Feminino , Cálculos Biliares/diagnóstico por imagem , Humanos , Lactente , Intestino Delgado/patologia , Hepatopatias/diagnóstico por imagem , Hepatopatias/epidemiologia , Masculino , Nutrição Parenteral/métodos , Síndrome do Intestino Curto/terapia , Ultrassonografia
20.
Pediatr Radiol ; 45(2): 273-82, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25179564

RESUMO

Interpreting complex paediatric body MRI studies requires the integration of information from multiple sequences. Image processing software, some freely available, allows the radiologist to use simple and rapid post-processing techniques that may aid diagnosis. We demonstrate the use of fusion and subtraction post-processing techniques with examples from four areas of application: enterography, oncological imaging, musculoskeletal imaging and MR fistulography.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Doenças Inflamatórias Intestinais/diagnóstico , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Sinovite/diagnóstico , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Software , Técnica de Subtração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA