Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38551698

RESUMO

OBJECTIVES: Objective measurements to predict the position of a cochlear electrode during cochlear implantation surgery may serve to improve the surgical technique and postoperative speech outcome. There is evidence that electrically evoked compound action potentials (ECAP) are a suitable approach to provide information about the site of stimulation. This study aims to contribute to the knowledge about the association between the intraoperative intracochlear ECAP characteristics and the site of stimulation. METHODS: In a retrospective cohort study, patients undergoing cochlear implant surgery with flexible lateral wall electrode arrays (12 stimulating channels) between 2020 and 2022 were analyzed. The CDL was measured using a CT-based clinical planning software. ECAP were measured for all electrode contacts and associated to the CDL as well as to the site of stimulation in degree. RESULTS: Significant differences among the amplitudes and slopes for the individual stimulated electrode contacts at the stimulation sites of 90°, 180°, 270°, 360°, 450° and 540° were found. The values showed a trend for linearity among the single electrodes. CONCLUSIONS: ECAP characteristics correlate with the electrode's position inside the cochlea. In the future, ECAP may be applied to assess the intracochlear position inside the cochlea and support anatomy-based fitting.

2.
Eur Arch Otorhinolaryngol ; 281(1): 43-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37466660

RESUMO

PURPOSE: In cochlear implantation with flexible lateral wall electrode arrays, a cochlear coverage (CC) range between 70% and 80% is considered ideal for optimal speech perception. To achieve this CC, the cochlear implant (CI) electrode array has to be chosen according to the individual cochlear duct length (CDL). Here, we mathematically analyzed the suitability of different flexible lateral wall electrode array lengths covering between 70% and 80% of the CDL. METHODS: In a retrospective cross-sectional study preoperative high-resolution computed tomography (HRCT) from patients undergoing cochlear implantation was investigated. The CDL was estimated using an otosurgical planning software and the CI electrode array lengths covering 70-80% of the CDL was calculated using (i) linear and (ii) non-linear models. RESULTS: The analysis of 120 HRCT data sets showed significantly different model-dependent CDL. Significant differences between the CC of 70% assessed from linear and non-linear models (mean difference: 2.5 mm, p < 0.001) and the CC of 80% assessed from linear and non-linear models (mean difference: 1.5 mm, p < 0.001) were found. In up to 25% of the patients none of the existing flexible lateral wall electrode arrays fit into this range. In 59 cases (49,2%) the models did not agree on the suitable electrode arrays. CONCLUSIONS: The CC varies depending on the underlying CDL approximation, which critically influences electrode array choice. Based on the literature, we hypothesize that the non-linear method systematically overestimates the CC and may lead to rather too short electrode array choices. Future studies need to assess the accuracy of the individual mathematical models.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Estudos Transversais , Dinâmica não Linear , Cóclea/diagnóstico por imagem , Cóclea/cirurgia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38630273

RESUMO

INTRODUCTION: Achieving a slow and smooth electrode array insertion is paramount for preserving structural and functional integrity during cochlear implantation. This controlled study evaluates the efficacy of a metronome-guided insertion technique in enhancing the smoothness and speed of electrode array insertions. METHODS: In a prospective cohort study, patients undergoing cochlear implant surgery between 2022 and 2023 with lateral wall electrode arrays were included. Metronome guidance was delivered through an acoustic signal via headphones during electrode array insertion in cochlear implantation and compared to a control group without metronome-guidance. RESULTS: In total, 37 cases were evaluated, including 25 conventional insertions and 12 metronome-guided insertions. The results indicate that metronome-guided insertions were significantly slower (- 0.46 mm/s; p < 0.001) without extending the overall procedure time. This can be attributed to fewer paused sections observed in the metronome-guided technique. Moreover, metronome-guided insertions exhibited superior performance in terms of insertion smoothness and a reduced number of re-gripping events. CONCLUSIONS: The findings support the recommendation for the systematic application of metronome guidance in the manual insertion of cochlear implant electrode arrays, emphasizing its potential to optimize surgical outcomes.

4.
HNO ; 72(3): 143-153, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38224355

RESUMO

BACKGROUND: In the course of the restructuring of medical studies, practical competencies are clearly defined as learning objectives for the first time. In order to make most effective use of the short attendance time available in otolaryngology, the aim of this study was to teach practical skills with the help of flipped classroom, digital teaching, and a newly established SkillsLab. MATERIALS AND METHODS: During their ENT internship, two groups of students-group A = 93 students (male n = 42, female n = 51) and group B = 113 students (male n = 42, female n = 71)-first worked through material provided online, which explained the individual examinations. This was followed by face-to-face teaching, which consisted of observation and practical exercise of the different examination techniques. While group A practiced on each other or on dummies, group B used structured workstations in the ENT SkillsLab, which was newly built for this purpose. The effects on motivation and subjective competence were measured using a questionnaire developed for this study. RESULTS: After working through the online material, both groups showed a high level of motivation and competence. On the day of face-to-face teaching, there was a gain in motivation and competence, which was statistically significant only in the SkillsLab group (p < 0.001). Although the SkillsLab group was inferior in terms of its subjective competence at the beginning, it was superior to the other group after the face-to-face teaching. CONCLUSION: Combination of digitized teaching in the flipped classroom with structured workstations in the setting of a SkillsLab enables more effective teaching of practical skills, which was reflected by increases in motivation and subjective competence in group B. In particular, the presentation of all collected findings on monitors allows verification of learning success and stimulates discussion.


Assuntos
Aprendizagem , Estudantes de Medicina , Masculino , Humanos , Feminino , Motivação , Inquéritos e Questionários , Currículo , Ensino
5.
Eur Arch Otorhinolaryngol ; 280(5): 2149-2154, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36210370

RESUMO

PURPOSE: A narrow bony internal auditory canal (IAC) may be associated with a hypoplastic cochlear nerve and poorer hearing performances after cochlear implantation. However, definitions for a narrow IAC vary widely and commonly, qualitative grading or two-dimensional measures are used to characterize a narrow IAC. We aimed to refine the definition of a narrow IAC by determining IAC volume in both control patients and patients with inner ear malformations (IEMs). METHODS: In this multicentric study, we included high-resolution CT (HRCT) scans of 128 temporal bones (85 with IEMs: cochlear aplasia, n = 11; common cavity, n = 2; cochlear hypoplasia type, n = 19; incomplete partition type I/III, n = 8/8; Mondini malformation, n = 16; enlarged vestibular aqueduct syndrome, n = 19; 45 controls). The IAC diameter was measured in the axial plane and the IAC volume was measured by semi-automatic segmentation and three-dimensional reconstruction. RESULTS: In controls, the mean IAC diameter was 5.5 mm (SD 1.1 mm) and the mean IAC volume was 175.3 mm3 (SD 52.6 mm3). Statistically significant differences in IAC volumes were found in cochlear aplasia (68.3 mm3, p < 0.0001), IPI (107.4 mm3, p = 0.04), and IPIII (277.5 mm3, p = 0.0004 mm3). Inter-rater reliability was higher in IAC volume than in IAC diameter (intraclass correlation coefficient 0.92 vs. 0.77). CONCLUSIONS: Volumetric measurement of IAC in cases of IEMs reduces measurement variability and may add to classifying IEMs. Since a hypoplastic IAC can be associated with a hypoplastic cochlear nerve and sensorineural hearing loss, radiologic assessment of the IAC is crucial in patients with severe sensorineural hearing loss undergoing cochlear implantation.


Assuntos
Orelha Interna , Perda Auditiva Neurossensorial , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Orelha Interna/diagnóstico por imagem , Orelha Interna/anormalidades , Cóclea/diagnóstico por imagem , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/cirurgia
6.
Eur Arch Otorhinolaryngol ; 280(5): 2155-2163, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36216913

RESUMO

OBJECTIVES: Enlarged vestibular aqueduct (EVA) is a common finding associated with inner ear malformations (IEM). However, uniform radiologic definitions for EVA are missing and various 2D-measurement methods to define EVA have been reported. This study evaluates VA volume in different types of IEM and compares 3D-reconstructed VA volume to 2D-measurements. METHODS: A total of 98 high-resolution CT (HRCT) data sets from temporal bones were analyzed (56 with IEM; [cochlear hypoplasia (CH; n = 18), incomplete partition type I (IPI; n = 12) and type II (IPII; n = 11) and EVA (n = 15)]; 42 controls). VA diameter was measured in axial images. VA volume was analyzed by software-based, semi-automatic segmentation and 3D-reconstruction. Differences in VA volume between the groups and associations between VA volume and VA diameter were assessed. Inter-rater-reliability (IRR) was assessed using the intra-class-correlation-coefficient (ICC). RESULTS: Larger VA volumes were found in IEM compared to controls. Significant differences in VA volume between patients with EVA and controls (p < 0.001) as well as between IPII and controls (p < 0.001) were found. VA diameter at the midpoint (VA midpoint) and at the operculum (VA operculum) correlated to VA volume in IPI (VA midpoint: r = 0.78, VA operculum: r = 0.91), in CH (VA midpoint: r = 0.59, VA operculum: r = 0.61), in EVA (VA midpoint: r = 0.55, VA operculum: r = 0.66) and in controls (VA midpoint: r = 0.36, VA operculum: r = 0.42). The highest IRR was found for VA volume (ICC = 0.90). CONCLUSIONS: The VA diameter may be an insufficient estimate of VA volume, since (1) measurement of VA diameter does not reliably correlate with VA volume and (2) VA diameter shows a lower IRR than VA volume. 3D-reconstruction and VA volumetry may add information in diagnosing EVA in cases with or without additional IEM.


Assuntos
Perda Auditiva Neurossensorial , Aqueduto Vestibular , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Aqueduto Vestibular/diagnóstico por imagem , Aqueduto Vestibular/anormalidades , Cóclea
7.
HNO ; 71(9): 556-565, 2023 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-37422596

RESUMO

BACKGROUND: Chronic otitis media (COM) can lead to significant impairment of health-related quality of life (HRQoL) due to symptoms such as otorrhea, pain, hearing loss, tinnitus, or dizziness. A systematic assessment of HRQoL in COM is becoming increasingly important as it complements (semi-)objective outcome parameters in clinical practice and research. HRQoL is measured by means of patient-reported outcome measures (PROMs). There are two disease-specific validated PROMs available for COM in German-the Chronic Otitis Media Outcome Test (COMOT-15) and the Zurich Chronic Middle Ear Inventory (ZCMEI-21)-which have become increasingly popular in recent years. OBJECTIVE: The purpose of this narrative review is to present the current state of research on measuring HRQoL in COM before and after surgical procedures. RESULTS AND CONCLUSION: Hearing is the most important factor influencing HRQoL in COM. Surgical procedures usually result in a clinically relevant improvement in HRQoL in COM with or without cholesteatoma. However, if cholesteatoma is present, its extent does not correlate with HRQoL. While HRQoL plays a secondary role in establishment of the indication for surgical therapy in COM with cholesteatoma, it plays an important role in terms of relative surgical indications, e.g., a symptomatic open mastoid cavity after resection of the posterior canal wall. We encourage the regular use of disease-specific PROMs preoperatively as well as during follow-up to assess HRQoL in COM in individual patients, in research, and in the context of quality monitoring.


Assuntos
Colesteatoma da Orelha Média , Otite Média , Humanos , Qualidade de Vida , Inquéritos e Questionários , Otite Média/diagnóstico , Otite Média/cirurgia , Otite Média/complicações , Orelha Média , Doença Crônica , Resultado do Tratamento
8.
Eur Radiol ; 32(2): 1014-1023, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34463797

RESUMO

OBJECTIVES: Knowledge about cochlear duct length (CDL) may assist electrode choice in cochlear implantation (CI). However, no gold standard for clinical applicable estimation of CDL exists. The aim of this study is (1) to determine the most reliable radiological imaging method and imaging processing software for measuring CDL from clinical routine imaging and (2) to accurately predict the insertion depth of the CI electrode. METHODS: Twenty human temporal bones were examined using different sectional imaging techniques (high-resolution computed tomography [HRCT] and cone beam computed tomography [CBCT]). CDL was measured using three methods: length estimation using (1) a dedicated preclinical 3D reconstruction software, (2) the established A-value method, and (3) a clinically approved otosurgical planning software. Temporal bones were implanted with a 31.5-mm CI electrode and measurements were compared to a reference based on the CI electrode insertion angle measured by radiographs in Stenvers projection (CDLreference). RESULTS: A mean cochlear coverage of 74% (SD 7.4%) was found. The CDLreference showed significant differences to each other method (p < 0.001). The strongest correlation to the CDLreference was found for the otosurgical planning software-based method obtained from HRCT (CDLSW-HRCT; r = 0.87, p < 0.001) and from CBCT (CDLSW-CBCT; r = 0.76, p < 0.001). Overall, CDL was underestimated by each applied method. The inter-rater reliability was fair for the CDL estimation based on 3D reconstruction from CBCT (CDL3D-CBCT; intra-class correlation coefficient [ICC] = 0.43), good for CDL estimation based on 3D reconstruction from HRCT (CDL3D-HRCT; ICC = 0.71), poor for CDL estimation based on the A-value method from HRCT (CDLA-HRCT; ICC = 0.29), and excellent for CDL estimation based on the A-value method from CBCT (CDLA-CBCT; ICC = 0.87) as well as for the CDLSW-HRCT (ICC = 0.94), CDLSW-CBCT (ICC = 0.94) and CDLreference (ICC = 0.87). CONCLUSIONS: All approaches would have led to an electrode choice of rather too short electrodes. Concerning treatment decisions based on CDL measurements, the otosurgical planning software-based method has to be recommended. The best inter-rater reliability was found for CDLA-CBCT, for CDLSW-HRCT, for CDLSW-CBCT, and for CDLreference. KEY POINTS: • Clinically applicable calculations using high-resolution CT and cone beam CT underestimate the cochlear size. • Ten percent of cochlear duct length need to be added to current calculations in order to predict the postoperative CI electrode position. • The clinically approved otosurgical planning software-based method software is the most suitable to estimate the cochlear duct length and shows an excellent inter-rater reliability.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/diagnóstico por imagem , Ducto Coclear/cirurgia , Tomografia Computadorizada de Feixe Cônico , Eletrodos Implantados , Humanos , Reprodutibilidade dos Testes , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X
9.
Eur Arch Otorhinolaryngol ; 279(5): 2353-2361, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34146149

RESUMO

PURPOSE: Cold water and wind are known to cause exostoses of the external auditory canal. Different prevalences in different sports have been described in the literature. The aim of this study was to investigate the prevalence of external auditory exostosis (EAE) and EAE severity in coastal German wind- and kitesurfers who are exposed to cold water and strong winds. Furthermore, influencing factors such as the total exposure time and frequency of activity as well as the correlations between symptoms and the severity of EAE were investigated. METHODS: In this retrospective cross-sectional study, German non-professional wind- and kitesurfers along the North and Baltic Sea coasts were recruited between September 2020 and November 2020. Each participant was interviewed about exposure time and otological symptoms and underwent bilateral video otoscopic examination to determine EAE severity. RESULTS: A total of 241 ears from 130 subjects were analysed. The prevalence of EAE was 75.1%. In 19.9% of the participants, severe EAE was found. Exposure time and the frequency of activity had significant effects on the severity of EAE. Compared to surfers, EAE growth seems to progress faster in wind- and kitesurfers. The number of symptoms requiring medical treatment increased when two-thirds of the external auditory canal was obstructed. CONCLUSION: The prevalence of EAE in wind- and kitesurfers is high. Total exposure time and the frequency of activity influence EAE growth. EAE growth occurs faster in wind- and kitesurfers than in surfers. The additional influence of wind and the evaporative cooling of the EAC are thought to be responsible. The results of this study should increase awareness of the dynamics of EAE among ENT specialists and improve patient counselling.


Assuntos
Exostose , Esportes Aquáticos , Estudos Transversais , Meato Acústico Externo/cirurgia , Exostose/epidemiologia , Exostose/etiologia , Humanos , Estudos Retrospectivos , Água , Vento
10.
Eur Arch Otorhinolaryngol ; 279(2): 703-711, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33788035

RESUMO

PURPOSE: Evaluating the current health state in chronic otitis media (COM), audiologic results are complemented by subjective outcomes, such as health-related quality of life (HRQoL). Two disease-specific instruments assessing HRQoL in COM in German-speaking patients exist, i.e., the chronic otitis media outcome test (COMOT-15) and the Zurich chronic middle ear inventory (ZCMEI-21). Since the psychometric properties of these questionnaires in a concurrent application are unknown, the aim of this study was to compare the COMOT-15 and the ZCMEI-21. METHODS: HRQoL was assessed in adult COM patients using the COMOT-15 and the ZCMEI-21. Psychometric properties were determined, including response distribution, concurrent validity, internal consistency, correlation to hearing and gender differences. RESULTS: In 173 patients (mean age 51.5 years), both questionnaires showed normally distributed scores without strong floor and ceiling effects. The total scores and subscores of both questionnaires exhibited satisfactory internal consistency (Cronbach's α 0.7-0.9) with the exception of the COMOT-15 hearing subscore (α = 0.94) and the ZCMEI-21 medical resource subscore (α = 0.66). Fair correlations between the air conduction pure-tone average and the total scores were found (COMOT-15: r = 0.36, p < 0.0001; ZCMEI-21: r = 0.34, p < 0.0001). CONCLUSION: In the first study comparing the COMOT-15 and the ZCMEI-21, both questionnaires exhibited satisfactory psychometric properties with several subtle differences. The COMOT-15 has a strong focus on hearing with a probably redundant content of the hearing subscore and may be suited for hearing-focused research questions. The ZCMEI-21 provides a comprehensive assessment of the COM symptom complex and may therefore also be used in research settings, where ear discharge, vertigo or pain should be covered.


Assuntos
Otite Média , Qualidade de Vida , Adulto , Doença Crônica , Humanos , Pessoa de Meia-Idade , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários
11.
Eur Arch Otorhinolaryngol ; 279(6): 2865-2871, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34424381

RESUMO

BACKGROUND: Attendance teaching is the predominant teaching method at universities but needs to be questioned in the context of digital transformation. This study establishes and evaluates a method to accomplish electronic learning to supplement traditional attendance courses. MATERIALS AND METHODS: Surgery was transmitted in real-time conditions via an online live stream from the surgical theater. Visualization was transferred from a fully digital surgical microscope, an endoscope or an environmental camera in high definition quality. Students were able to participate at home from their personal computer. After following the surgery, they participated in an online-evaluation. RESULTS: A total of 65 students participated in the live stream. The majority of students (61.54%) indicated a significant subjective increase in knowledge after participation. The majority of students (53.85%) indicated that live surgeries should be offered as a permanent component in addition to classroom teaching. Likewise, a broader offer was desired by many students (63.08%). CONCLUSIONS: Live streaming of surgery is a promising approach as an alternative or supplement to traditional attendance teaching. An expansion of digital teaching can be explicitly supported on the basis of this study.


Assuntos
Aprendizagem , Estudantes , Humanos , Ensino
12.
HNO ; 70(7): 557-563, 2022 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-35318498

RESUMO

OBJECTIVE: In patients with cleft palate, a high incidence of chronic obstructive Eustachian tube dysfunction (ETD) is assumed after surgery. Consequently, an increased rate of retracted eardrum or cholesteatoma is expected. Even though no common standard for investigating ETD is available, the development of objective tests has increased during the past 10 years. This study aimed to investigate the incidence of persisting chronic obstructive ETD in adult patients with cleft palate surgically treated in early childhood by using a combination of diagnostic tools. METHODS: Adult participants with cleft palate repair in early childhood were invited for a follow-up examination and compared to a control group. Examination included tympanometry, tubomanometry, the Eustachian Tube Dysfunction Questionnaire (ETDQ-7), and the Eustachian Tube Score 7 (ETS-7). RESULTS: A total of 16 adult patients were re-examined after cleft palate surgery and compared to a control group of 40 healthy individuals. Significant differences were found in the median ETS­7 (p < 0.0001) score but not in the median ETDQ­7 (p = 0.09) score. Only 2 of the 32 investigated ears (6%) had pathologic scores in ETS­7 and ETDQ­7 (p = 0.09), whereas 5 (31%) cleft palate patients showed symptoms of chronic obstructive ETD according to ETS­7. No patient had examination findings indicating a requirement for further treatment. CONCLUSION: By combining diagnostic tools for ETD, a lower rate of persisting obstructive ETD in adults after cleft palate surgery was found than previously reported. Successful surgical treatment of cleft palate seems to lead to physiological Eustachian tube function in long-term follow up.


Assuntos
Fissura Palatina , Otopatias , Tuba Auditiva , Testes de Impedância Acústica , Adulto , Pré-Escolar , Fissura Palatina/diagnóstico , Fissura Palatina/cirurgia , Otopatias/diagnóstico , Humanos , Inquéritos e Questionários
13.
HNO ; 70(8): 609-617, 2022 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-35665824

RESUMO

BACKGROUND: The development of technological innovations has not only changed social life and the healthcare system, but also affects medical education. The aim of this pilot study was to evaluate whether students, when observing a microsurgical procedure of the temporal bone, gain an additional understanding of the anatomical structures and surgical site when visualization is used that provides identical views for the surgeon and viewer in 3D. MATERIALS AND METHODS: During regular attendance tutorials, students were randomly assigned to three different groups: control group, 2D group, or 3D group. Evaluation questionnaires and intraoperative student annotation of the surgical view were used to assess the subjective didactic value of different visualization formats and resultant learning experiences for the students. RESULTS: A total of 47 students were included in the investigations during conventional attendance tutorials. The majority indicated a high added value of the 3D visualization in terms of method (70%) and vividness (80%) compared to the 2D group and self-study; 69% of the students fully agreed with the statement that 2D and 3D visualization increases learning motivation and is a very good way to improve recognition of anatomical topography and structures. CONCLUSION: New interactive visualization options in teaching promote learning efficiency and motivation among students. Especially 3D visualization and intraoperative annotation of the surgical view by the student is a useful didactic tool and increases the quality of clinical teaching. It supports the perception of anatomical topography and enables more focused surgical training.


Assuntos
Educação Médica , Estudantes de Medicina , Humanos , Aprendizagem , Motivação , Projetos Piloto , Estudantes
14.
Eur Arch Otorhinolaryngol ; 278(10): 3795-3800, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33242111

RESUMO

PURPOSE: Different types of chronic middle ear disease (CMED) present with differing severity of single symptoms, such as discharge, vertigo or hearing loss, which impair health-related quality of life (HRQoL). Here, we aimed to (i) investigate characteristics of HRQoL and (ii) evaluate the association between HRQoL and hearing among different types of CMED. METHODS: In this prospective longitudinal cohort study, we included adult patients undergoing surgical treatment for CMED. Primary outcomes included HRQoL assessed by the Zurich Chronic Middle Ear Inventory (ZCMEI-21) and hearing assessed by pure-tone audiometry. RESULTS: In the included 108 patients (51% females), CMED were chronic otitis media (COM) with (n = 46) or without (n = 22) cholesteatoma, persistent mastoid cavity (with [n = 15] or without [n = 10] recurrent cholesteatoma), revision ossiculoplasty for hearing restoration (n = 14), and postinflammatory meatal fibrosis (n = 1). Preoperatively, the mean ZCMEI-21 score showed statistically significant differences among different types of CMED (p = 0.007) with persistent mastoid cavity without cholesteatoma exhibiting the highest score (34.1, SD 7.7) indicating poor HRQoL. At a mean follow-up period of 183 days, no statistically significant differences in the ZCMEI-21 scores among different types of CMED were observed (p = 0.67). CONCLUSION: This study objectifies differences in HRQoL among different types of CMED. In patients with indication for functional surgery only, e.g., persistent mastoid cavity without cholesteatoma, the worst HRQoL was observed. Yet, in these types of CMED, HRQoL guides decision for treatment. Moreover, differences in HRQoL among different types of CMED were not closely associated with hearing, but largely depended on other symptoms, such as discharge or vertigo.


Assuntos
Colesteatoma da Orelha Média , Otite Média , Adulto , Colesteatoma da Orelha Média/cirurgia , Doença Crônica , Orelha Média , Feminino , Humanos , Estudos Longitudinais , Masculino , Processo Mastoide , Otite Média/cirurgia , Estudos Prospectivos , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento , Timpanoplastia
15.
Eur Arch Otorhinolaryngol ; 278(5): 1365-1371, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32661718

RESUMO

PURPOSE: To establish a standardized reporting system of cholesteatoma, the ChOLE classification has recently been introduced. We here aimed to systematically investigate the association between the ChOLE classification and (i) hearing, (ii) recidivism rate, and (iii) postoperative complications. These data may increase the utility of the ChOLE classification in clinical practice and research by stratifying patients according to expected outcomes or risks for complications. METHODS: In this prospective multicentric study, we included adult patients undergoing tympanomastoid surgery due to cholesteatoma. Main outcome measures included the association of the ChOLE classification system with (i) audiometric data including air conduction (AC) and bone conduction (BC) pure-tone average (PTA), and the air-bone gap (ABG), (ii) recidivism and complication. RESULTS: A total of 160 patients suffering from cholesteatoma were included. ChOLE stage distribution was stage I in 23 (14%), stage II in 128 (80%), and stage III in 9 (6%) patients. The ChOLE stage was associated with the postoperative AC PTA (p = 0.05) and the postoperative BC PTA (p = 0.02). Further, the status of the ossicular chain after surgery (ChOLE subdivision "O") was associated with both the postoperative ABG (p = 0.0001) and the postoperative AC PTA (p = 0.003). Moreover, we found an association between complications (ChOLE subdivision "L) and both the postoperative BC PTA (p = 0.04) and the postoperative ABG (p = 0.04). No association between the ChOLE stage was found to both cholesteatoma recidivism and surgical complications. CONCLUSION: The ChOLE classification is a new system to classify cholesteatomas. We provide evidence that hearing outcomes vary among different ChOLE stages. In particular, hearing outcomes are associated with the ChOLE subdivision "O" and "L". Thus, the ChOLE classification system has a predictive value regarding hearing outcomes.


Assuntos
Colesteatoma da Orelha Média , Reincidência , Adulto , Audiometria de Tons Puros , Colesteatoma da Orelha Média/cirurgia , Audição , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Timpanoplastia
16.
Eur Arch Otorhinolaryngol ; 278(6): 1773-1779, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32748185

RESUMO

INTRODUCTION: In cochlear implantation, objective fitting methods are needed to optimize audiological results in small children or patients with poor compliance. Intraoperatively measured electrically evoked stapedius reflexes (eSR) can be used as a marker for the patient's discomfort level. The aim of this study was to develop and evaluate an automated detection method for eSR and to compare it to the detection rate of the surgeon and independent observers. METHODS: Cochlear implantation using a fully digital surgical microscope was performed. Movements of the stapedius tendon were recorded and analyzed by means of computer vision technique. Differences in eSR elicited by stimulating electrodes at different cochlear locations (basal, middle and apical) were analyzed. The eSR detection rate of the image processing algorithm was compared to the surgeon's detection rate and to those of two less experienced observers. RESULTS: A total of 387 electrically impulses were applied. The stimulation of middle turn electrodes showed significantly higher detection rates (50.4%) compared to the basal (40.0%; p = 0.001) and apical (43.6%; p = 0.03) turn. The software identified significantly more of the applied stimuli (58.4%) compared to the surgeon (46.3%; p = 0.0007), the intermediate observer (37.7%; p < 0.0001) and the unexperienced observer (41.3%; p < 0.0001). CONCLUSION: The feasibility of an automated intraoperative software-based detection of eSR is demonstrated. By improving the eSR detection methods and their clinical applicability, their utility in objective cochlear implant fitting may be substantially increased.


Assuntos
Implante Coclear , Implantes Cocleares , Limiar Auditivo , Criança , Estimulação Elétrica , Humanos , Reflexo Acústico , Estapédio
17.
Eur Arch Otorhinolaryngol ; 278(4): 1027-1033, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32613353

RESUMO

INTRODUCTION: Improvements of surgical visualization add value to the quality of clinical routine and offer the opportunity to improve surgical education of medical staff. The aim of this study was to determine whether otorhinolaryngology trainees gain additional comprehension of the anatomical structures and the surgical site when 3D visualization is used. METHODS: Data were collected from ENT trainees of microsurgical courses of the middle ear, inner ear and lateral skull base at four university ENT departments (Charité (Berlin), Martin Luther University Halle-Wittenberg (Halle/Saale), Ludwig Maximilian University (Munich) and Rostock University Medical Center). Participants were asked to complete a questionnaire assessing the subjective value of identical surgical field visualization in 3D for surgeon and observer. RESULTS: A total of 112 participants completed the questionnaire. The majority of participants stated a high additional value of 3D visualization compared to 2D visualization, with 75% fully agreeing to the statement that 3D visualization of the surgical field is superior to perceive the anatomical topography and structures compared to 2D representation. Participants encouraged the storage of data in online learning platforms. CONCLUSION: The results show that 3D visualization with identical imaging for surgeon and observer is a useful tool in teaching of microsurgery. It addresses perception of anatomical topography and structures as well as conception of the surgical workflow.


Assuntos
Imageamento Tridimensional , Base do Crânio , Berlim , Humanos
18.
HNO ; 69(12): 1002-1008, 2021 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-33730246

RESUMO

Vestibular schwannomas (VS) are benign tumors that originate from the nerve sheath of one of the two vestibular nerves. VS can have a severe impact on everyday life of the patient and may lead to symptoms such as vertigo, hearing loss (e.g., as sudden deafness), deafness, and tinnitus. Treatment concepts include observational waiting with regular imaging control ("wait and scan"), radiotherapy, or surgical resection. Depending on the size of the tumor and status of functional hearing, the surgical approach may be retrosigmoidal, transtemporal, retrolabyrinthine, or translabyrinthine. The translabyrinthine approach always results in complete deafness due to opening of the bony labyrinth. If the nerve structure of the cochlear nerve is preserved, hearing rehabilitation with a cochlear implant (CI) may be successful. In this article the surgical technique for microsurgical resection of VS using a translabyrinthine approach with simultaneous cochlear implantation under intraoperative monitoring of the cochlear nerve by electrical stimulation is presented.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Súbita , Neuroma Acústico , Nervo Coclear , Humanos , Neuroma Acústico/complicações , Neuroma Acústico/cirurgia , Estudos Retrospectivos
19.
HNO ; 69(Suppl 2): 82-87, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34019139

RESUMO

Vestibular schwannomas (VS) are benign tumors that originate from the nerve sheath of one of the two vestibular nerves. VS can have a severe impact on everyday life of the patient and may lead to symptoms such as vertigo, hearing loss (e.g., as sudden deafness), deafness, and tinnitus. Treatment concepts include observational waiting with regular imaging control ("wait and scan"), radiotherapy, or surgical resection. Depending on the size of the tumor and status of functional hearing, the surgical approach may be retrosigmoidal, transtemporal, retrolabyrinthine, or translabyrinthine. The translabyrinthine approach always results in complete deafness due to opening of the bony labyrinth. If the nerve structure of the cochlear nerve is preserved, hearing rehabilitation with a cochlear implant (CI) may be successful. In this article the surgical technique for microsurgical resection of VS using a translabyrinthine approach with simultaneous cochlear implantation under intraoperative monitoring of the cochlear nerve by electrical stimulation is presented.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Súbita , Neuroma Acústico , Nervo Coclear , Humanos , Neuroma Acústico/complicações , Neuroma Acústico/cirurgia
20.
HNO ; 69(8): 642-649, 2021 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-33537879

RESUMO

BACKGROUND: With increasing access to online teaching materials, traditional teaching methods at universities need to be questioned in the context of digital transformation. The aim of this study was to evaluate whether electronic learning may serve as or replace conventional internship in otorhinolaryngology. MATERIALS AND METHODS: A completely digital electronic learning concept was created and made available at the online learning platform ILIAS. Students were introduced to the program. Four learning units (neck [I], pharynx/larynx [II], nose [III], ear [IV]) were set up, with a topic-related multiple-choice test at the end of each unit. The students took part in the evaluation before and after completion of the course. RESULTS: A total of 105 students participated in the evaluation before and 85 students after the electronic learning program. After completing the courses, the majority of students (52.94%) stated to be more satisfied with the content and the presentation of the learning sequences as well as with their own self-control concerning learning pace and time management compared to the situation before completing the program (34.29%; p < 0.0001). The majority of students (54.12%) stated that they would appreciate the electronic learning program in addition to practical internship. CONCLUSION: The electronic learning program is a promising approach to supplement traditional learning and internships. An expansion of digital teaching proposals should be supported based on this study.


Assuntos
Educação a Distância , Otolaringologia , Eletrônica , Humanos , Aprendizagem , Estudantes , Ensino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA