Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Exp Eye Res ; : 110045, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39154819

RESUMO

The choroid, which is a highly vascularized layer between the retina and sclera, is essential for supplying oxygen and nutrients to the outer retina. Choroidal vascular dysfunction has been implicated in numerous ocular diseases, including age-related macular degeneration, central serous chorioretinopathy, polypoidal choroidal vasculopathy, and myopia. Traditionally, the in vivo assessment of choroidal blood flow relies on techniques such as laser Doppler flowmetry, laser speckle flowgraphy, pneumotonometry, laser interferometry, and ultrasonic color Doppler imaging. While the aforementioned methods have provided valuable insights into choroidal blood flow regulation, their clinical applications have been limited. Recent advancements in optical coherence tomography and optical coherence tomography angiography have expanded our understanding of the choroid, allowing detailed visualization of the larger choroidal vessels and choriocapillaris, respectively. This review provides an overview of the available techniques that can investigate the choroid and its blood flow in vivo. Future research should combine these techniques to comprehensively image the entire choroidal microcirculation and develop robust methods to quantify choroidal blood flow. The potential findings will provide a better picture of choroidal hemodynamics and its effect on ocular health and disease.

2.
Sci Rep ; 14(1): 17909, 2024 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095380

RESUMO

The effect of diabetes mellitus (DM) on individual retinal layers remains incompletely understood. We evaluated the intra-retinal layer thickness alterations in 71 DM eyes with no diabetic retinopathy (DR), 90 with mild DR, and 63 with moderate DR without macular edema, using spectral-domain optical coherence tomography (SD-OCT) and the Iowa Reference Algorithm for automated retinal layer segmentation. The average thickness of 10 intra-retinal layers was then corrected for ocular magnification using axial length measurements, and pairwise comparisons were made using multivariable linear regression models adjusted for gender and race. In DM no DR eyes, significant thinning was evident in the ganglion cell layer (GCL; p < 0.001), inner nuclear layer (INL; p = 0.001), and retinal pigment epithelium (RPE; p = 0.014) compared to normal eyes. Additionally, mild DR eyes exhibited a thinner inner plexiform layer (IPL; p = 0.008) than DM no DR eyes. Conversely, moderate DR eyes displayed thickening in the INL, outer nuclear layer, IPL, and retinal nerve fiber layer (all p ≤ 0.002), with notably worse vision. These findings highlight distinctive patterns: early diabetic eyes experience thinning in specific retinal layers, while moderate DR eyes exhibit thickening of certain layers and slightly compromised visual acuity, despite the absence of macular edema. Understanding these structural changes is crucial for comprehending diabetic eye complications.


Assuntos
Retinopatia Diabética , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Masculino , Feminino , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/patologia , Pessoa de Meia-Idade , Idoso , Retina/diagnóstico por imagem , Retina/patologia , Edema Macular/diagnóstico por imagem , Edema Macular/patologia , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Epitélio Pigmentado da Retina/patologia , Epitélio Pigmentado da Retina/diagnóstico por imagem , Células Ganglionares da Retina/patologia
3.
Sci Rep ; 14(1): 8724, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622152

RESUMO

The objective of this study is to define structure-function relationships of pathological lesions related to age-related macular degeneration (AMD) using microperimetry and multimodal retinal imaging. We conducted a cross-sectional study of 87 patients with AMD (30 eyes with early and intermediate AMD and 110 eyes with advanced AMD), compared to 33 normal controls (66 eyes) recruited from a single tertiary center. All participants had enface and cross-sectional optical coherence tomography (Heidelberg HRA-2), OCT angiography, color and infra-red (IR) fundus and microperimetry (MP) (Nidek MP-3) performed. Multimodal images were graded for specific AMD pathological lesions. A custom marking tool was used to demarcate lesion boundaries on corresponding enface IR images, and subsequently superimposed onto MP color fundus photographs with retinal sensitivity points (RSP). The resulting overlay was used to correlate pathological structural changes to zonal functional changes. Mean age of patients with early/intermediate AMD, advanced AMD and controls were 73(SD = 8.2), 70.8(SD = 8), and 65.4(SD = 7.7) years respectively. Mean retinal sensitivity (MRS) of both early/intermediate (23.1 dB; SD = 5.5) and advanced AMD (18.1 dB; SD = 7.8) eyes were significantly worse than controls (27.8 dB, SD = 4.3) (p < 0.01). Advanced AMD eyes had significantly more unstable fixation (70%; SD = 63.6), larger mean fixation area (3.9 mm2; SD = 3.0), and focal fixation point further away from the fovea (0.7 mm; SD = 0.8), than controls (29%; SD = 43.9; 2.6 mm2; SD = 1.9; 0.4 mm; SD = 0.3) (p ≤ 0.01). Notably, 22 fellow eyes of AMD eyes (25.7 dB; SD = 3.0), with no AMD lesions, still had lower MRS than controls (p = 0.04). For specific AMD-related lesions, end-stage changes such as fibrosis (5.5 dB, SD = 5.4 dB) and atrophy (6.2 dB, SD = 7.0 dB) had the lowest MRS; while drusen and pigment epithelial detachment (17.7 dB, SD = 8.0 dB) had the highest MRS. Peri-lesional areas (20.2 dB, SD = 7.6 dB) and surrounding structurally normal areas (22.2 dB, SD = 6.9 dB) of the retina with no AMD lesions still had lower MRS compared to controls (27.8 dB, SD = 4.3 dB) (p < 0.01). Our detailed topographic structure-function correlation identified specific AMD pathological changes associated with a poorer visual function. This can provide an added value to the assessment of visual function to optimize treatment outcomes to existing and potentially future novel therapies.


Assuntos
Degeneração Macular , Humanos , Estudos Transversais , Estudos Prospectivos , Degeneração Macular/diagnóstico por imagem , Tomografia de Coerência Óptica , Angiofluoresceinografia , Relação Estrutura-Atividade
4.
Transl Vis Sci Technol ; 13(5): 9, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743409

RESUMO

Purpose: To assess the diagnostic performance and structure-function association of retinal retardance (RR), a customized metric measured by a prototype polarization-sensitive optical coherence tomography (PS-OCT), across various stages of glaucoma. Methods: This cross-sectional pilot study analyzed 170 eyes from 49 healthy individuals and 68 patients with glaucoma. The patients underwent PS-OCT imaging and conventional spectral-domain optical coherence tomography (SD-OCT), as well as visual field (VF) tests. Parameters including RR and retinal nerve fiber layer thickness (RNFLT) were extracted from identical circumpapillary regions of the fundus. Glaucomatous eyes were categorized into early, moderate, or severe stages based on VF mean deviation (MD). The diagnostic performance of RR and RNFLT in discriminating glaucoma from controls was assessed using receiver operating characteristic (ROC) curves. Correlations among VF-MD, RR, and RNFLT were evaluated and compared within different groups of disease severity. Results: The diagnostic performance of both RR and RNFLT was comparable for glaucoma detection (RR AUC = 0.98, RNFLT AUC = 0.97; P = 0.553). RR showed better structure-function association with VF-MD than RNFLT (RR VF-MD = 0.68, RNFLT VF-MD = 0.58; z = 1.99; P = 0.047) in glaucoma cases, especially in severe glaucoma, where the correlation between VF-MD and RR (r = 0.73) was significantly stronger than with RNFLT (r = 0.43, z = 1.96, P = 0.050). In eyes with early and moderate glaucoma, the structure-function association was similar when using RNFLT and RR. Conclusions: RR and RNFLT have similar performance in glaucoma diagnosis. However, in patients with glaucoma especially severe glaucoma, RR showed a stronger correlation with VF test results. Further research is needed to validate RR as an indicator for severe glaucoma evaluation and to explore the benefits of using PS-OCT in clinical practice. Translational Relevance: We demonstrated that PS-OCT has the potential to evaluate the status of RNFL structural damage in eyes with severe glaucoma, which is currently challenging in clinics.


Assuntos
Glaucoma , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Projetos Piloto , Campos Visuais/fisiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico por imagem , Idoso , Células Ganglionares da Retina/patologia , Curva ROC , Testes de Campo Visual/métodos , Adulto , Pressão Intraocular/fisiologia
5.
Br J Ophthalmol ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38719343

RESUMO

BACKGROUND/AIMS: To investigate whether compensating retinal nerve fibre layer (RNFL) thickness measurements for demographic and anatomical ocular factors can strengthen the structure-function relationship in patients with glaucoma. METHODS: 600 eyes from 412 patients with glaucoma (mean deviation of the visual field (MD VF) -6.53±5.55 dB) were included in this cross-sectional study. Participants underwent standard automated perimetry and spectral-domain optical coherence tomography imaging (Cirrus; Carl Zeiss Meditec). Compensated RNFL thickness was computed considering age, refractive error, optic disc parameters and retinal vessel density. The relationship between MD VF and RNFL thickness measurements, with or without demographic and anatomical compensation, was evaluated sectorally and focally. RESULTS: The superior arcuate sector exhibited the highest correlation between measured RNFL and MD VF, with a correlation of 0.49 (95% CI 0.37 to 0.59). Applying the compensated RNFL data increased the correlation substantially to 0.62 (95% CI 0.52 to 0.70; p<0.001). Only 61% of the VF locations showed a significant relationship (Spearman's correlation of at least 0.30) between structural and functional aspects using measured RNFL data, and this increased to 78% with compensated RNFL measurements. In the 10°-20° VF region, the slope below the breakpoint for compensated RNFL thickness demonstrated a more robust correlation (slope=1.66±0.18 µm/dB; p<0.001) than measured RNFL (slope=0.27±0.67 µm/dB; p=0.688). CONCLUSION: Compensated RNFL data improve the correlation between RNFL measurements and VF parameters. This indicates that creating structure-to-function maps that consider anatomical variances may aid in identifying localised structural and functional loss in glaucoma.

6.
Ann N Y Acad Sci ; 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39177491

RESUMO

The study aimed to evaluate the impact of compensating retinal nerve fiber layer (RNFL) thickness for demographic and anatomical factors on glaucoma detection in Chinese and Indian adults. A population-based study included 1995 healthy participants (1076 Chinese and 919 Indians) to construct a multivariable linear regression compensation model. This model was applied to 357 Chinese glaucoma patients, 357 healthy Chinese, and 357 healthy Indians using Cirrus spectral-domain optical coherence tomography (OCT). The compensated RNFL thickness considered age, refractive error, optic disc parameters, and retinal vessel density. Results showed that although the average RNFL thickness was significantly higher in Chinese participants compared to Indians, the compensation model reduced this difference to nonsignificance. Moreover, the compensation model significantly improved the area under the receiver operating characteristic curve (0.90 vs. 0.78; p<0.001), sensitivity (75% vs. 51%), and specificity (67% vs. 32%) in distinguishing Chinese glaucoma patients from healthy Indian individuals. The compensation model significantly enhanced the diagnostic accuracy of RNFL thickness in distinguishing glaucoma in the Chinese ethnic group compared to the OCT instrument's default values. These results suggest that modifying RNFL measurements based on individual characteristics can yield substantial benefits for glaucoma detection across ethnicities.

7.
BMJ Open Diabetes Res Care ; 12(1)2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167606

RESUMO

INTRODUCTION: Diabetic retinopathy (DR) is a leading cause of preventable blindness among working-age adults, primarily driven by ocular microvascular complications from chronic hyperglycemia. Comprehending the complex relationship between microvascular changes in the eye and disease progression poses challenges, traditional methods assuming linear or logistical relationships may not adequately capture the intricate interactions between these changes and disease advances. Hence, the aim of this study was to evaluate the microvascular involvement of diabetes mellitus (DM) and non-proliferative DR with the implementation of non-parametric machine learning methods. RESEARCH DESIGN AND METHODS: We conducted a retrospective cohort study that included optical coherence tomography angiography (OCTA) images collected from a healthy group (196 eyes), a DM no DR group (120 eyes), a mild DR group (71 eyes), and a moderate DR group (66 eyes). We implemented a non-parametric machine learning method for four classification tasks that used parameters extracted from the OCTA images as predictors: DM no DR versus healthy, mild DR versus DM no DR, moderate DR versus mild DR, and any DR versus no DR. SHapley Additive exPlanations values were used to determine the importance of these parameters in the classification. RESULTS: We found large choriocapillaris flow deficits were the most important for healthy versus DM no DR, and became less important in eyes with mild or moderate DR. The superficial microvasculature was important for the healthy versus DM no DR and mild DR versus moderate DR tasks, but not for the DM no DR versus mild DR task-the stage when deep microvasculature plays an important role. Foveal avascular zone metric was in general less affected, but its involvement increased with worsening DR. CONCLUSIONS: The findings from this study provide valuable insights into the microvascular involvement of DM and DR, facilitating the development of early detection methods and intervention strategies.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Adulto , Humanos , Retinopatia Diabética/etiologia , Retinopatia Diabética/diagnóstico , Estudos Retrospectivos , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Microvasos
8.
NPJ Digit Med ; 7(1): 115, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38704440

RESUMO

Spectral-domain optical coherence tomography (SDOCT) is the gold standard of imaging the eye in clinics. Penetration depth with such devices is, however, limited and visualization of the choroid, which is essential for diagnosing chorioretinal disease, remains limited. Whereas swept-source OCT (SSOCT) devices allow for visualization of the choroid these instruments are expensive and availability in praxis is limited. We present an artificial intelligence (AI)-based solution to enhance the visualization of the choroid in OCT scans and allow for quantitative measurements of choroidal metrics using generative deep learning (DL). Synthetically enhanced SDOCT B-scans with improved choroidal visibility were generated, leveraging matching images to learn deep anatomical features during the training. Using a single-center tertiary eye care institution cohort comprising a total of 362 SDOCT-SSOCT paired subjects, we trained our model with 150,784 images from 410 healthy, 192 glaucoma, and 133 diabetic retinopathy eyes. An independent external test dataset of 37,376 images from 146 eyes was deployed to assess the authenticity and quality of the synthetically enhanced SDOCT images. Experts' ability to differentiate real versus synthetic images was poor (47.5% accuracy). Measurements of choroidal thickness, area, volume, and vascularity index, from the reference SSOCT and synthetically enhanced SDOCT, showed high Pearson's correlations of 0.97 [95% CI: 0.96-0.98], 0.97 [0.95-0.98], 0.95 [0.92-0.98], and 0.87 [0.83-0.91], with intra-class correlation values of 0.99 [0.98-0.99], 0.98 [0.98-0.99], and 0.95 [0.96-0.98], 0.93 [0.91-0.95], respectively. Thus, our DL generative model successfully generated realistic enhanced SDOCT data that is indistinguishable from SSOCT images providing improved visualization of the choroid. This technology enabled accurate measurements of choroidal metrics previously limited by the imaging depth constraints of SDOCT. The findings open new possibilities for utilizing affordable SDOCT devices in studying the choroid in both healthy and pathological conditions.

9.
Eye Vis (Lond) ; 11(1): 21, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831465

RESUMO

BACKGROUND: Myopia affects 1.4 billion individuals worldwide. Notably, there is increasing evidence that choroidal thickness plays an important role in myopia and risk of developing myopia-related conditions. With the advancements in artificial intelligence (AI), choroidal thickness segmentation can now be automated, offering inherent advantages such as better repeatability, reduced grader variability, and less reliance for manpower. Hence, we aimed to evaluate the agreement between AI-automated and manual segmented measurements of subfoveal choroidal thickness (SFCT) using two swept-source optical coherence tomography (OCT) systems. METHODS: Subjects aged ≥ 16 years, with myopia of ≥ 0.50 diopters in both eyes, were recruited from the Prospective Myopia Cohort Study in Singapore (PROMYSE). OCT scans were acquired using Triton DRI-OCT and PLEX Elite 9000. OCT images were segmented both automatically with an established SA-Net architecture and manually using a standard technique with adjudication by two independent graders. SFCT was subsequently determined based on the segmentation. The Bland-Altman plot and intraclass correlation coefficient (ICC) were used to evaluate the agreement. RESULTS: A total of 229 subjects (456 eyes) with mean [± standard deviation (SD)] age of 34.1 (10.4) years were included. The overall SFCT (mean ± SD) based on manual segmentation was 216.9 ± 82.7 µm with Triton DRI-OCT and 239.3 ± 84.3 µm with PLEX Elite 9000. ICC values demonstrated excellent agreement between AI-automated and manual segmented SFCT measurements (PLEX Elite 9000: ICC = 0.937, 95% CI: 0.922 to 0.949, P < 0.001; Triton DRI-OCT: ICC = 0.887, 95% CI: 0.608 to 0.950, P < 0.001). For PLEX Elite 9000, manual segmented measurements were generally thicker when compared to AI-automated segmented measurements, with a fixed bias of 6.3 µm (95% CI: 3.8 to 8.9, P < 0.001) and proportional bias of 0.120 (P < 0.001). On the other hand, manual segmented measurements were comparatively thinner than AI-automated segmented measurements for Triton DRI-OCT, with a fixed bias of - 26.7 µm (95% CI: - 29.7 to - 23.7, P < 0.001) and proportional bias of - 0.090 (P < 0.001). CONCLUSION: We observed an excellent agreement in choroidal segmentation measurements when comparing manual with AI-automated techniques, using images from two SS-OCT systems. Given its edge over manual segmentation, automated segmentation may potentially emerge as the primary method of choroidal thickness measurement in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA