Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 179
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38568735

RESUMO

RATIONALE: A hemodynamically significant patent ductus arteriosus (hsPDA) in premature infants has been associated with bronchopulmonary dysplasia (BPD) and pulmonary hypertension (PH). However, these associations remain incompletely understood. OBJECTIVES: The aim was to assess the association between hsPDA duration with clinical outcomes, PH, and phenotypic differences on lung MRI. METHODS: This retrospective cohort study identified all infants with BPD <32 weeks gestation who also underwent a research lung MRI <48 weeks postmenstrual age (PMA) from 2014-2022. Clinical echocardiograms were reviewed for hsPDA, and categorized into no hsPDA, hsPDA 1-60 days, and hsPDA >60 days. Outcome variables included BPD severity, PH at 36 weeks PMA, PH after 36 weeks PMA in the absence of shunt (PH-PVD), tracheostomy or death, and lung phenotype by MRI via modified Ochiai score, indexed total lung volume (TLVI), and whole lung hyperdensity (WLH). Logistic regression and ANOVA analysis were used. MEASUREMENTS AND MAIN RESULTS: In total, 133 infants born at 26.2 ± 1.9 weeks and 776 ± 276g were reviewed (47 no hsPDA, 44 hsPDA 1-60 days, 42 hsPDA >60 days). hsPDA duration >60 days was associated with BPD severity (p<0.01), PH at 36 weeks PMA (aOR 9.7 [95% CI: 3.3-28.4]), PH-PVD (aOR 6.5 [95% CI: 2.3-18.3]), and tracheostomy or death (aOR 3.0 [95% CI: 1.0-8.8]). Duration of hsPDA > 60 days was associated with higher Ochiai score (p=0.03) and TLVI (p=0.01), but not WLH (p=0.91). CONCLUSIONS: In infants with moderate or severe BPD, prolonged exposure to hsPDA is associated with BPD severity, PH-PVD, and increased parenchymal lung disease by MRI.

2.
Magn Reson Med ; 89(3): 1117-1133, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36372970

RESUMO

PURPOSE: Xenon-129 (129 Xe) gas-exchange MRI is a pulmonary-imaging technique that provides quantitative metrics for lung structure and function and is often compared to pulmonary-function tests. Unlike such tests, it does not normalize to predictive values based on demographic variables such as age. Many sites have alluded to an age dependence in gas-exchange metrics; however, a procedure for normalizing metrics has not yet been introduced. THEORY: We model healthy reference values for 129 Xe gas-exchange MRI against age using generalized additive models for location, scale, and shape (GAMLSS). GAMLSS takes signal data from an aggregated heathy-reference cohort and fits a distribution with flexible median, variation, skewness, and kurtosis to predict age-dependent centiles. This approach mirrors methods by the Global Lung Function Initiative for modeling pulmonary-function test data and applies it to binning methods widely used by the 129 Xe MRI community to interpret and quantify gas-exchange data. METHODS: Ventilation, membrane-uptake, red blood cell transfer, and red blood cell:membrane gas-exchange metrics were collected on 30 healthy subjects over an age range of 5 to 68 years. A GAMLSS model was fit against age and compared against widely used linear and generalized-linear binning 129 Xe MRI analysis schemes. RESULTS: All 4 gas-exchange metrics had significant skewness, and membrane-uptake had significant kurtosis compared to a normal distribution. Age has significant impact on distribution parameters. GAMLSS-binning produced narrower bins compared to the linear and generalized-linear binning schemes and distributed signal data closer to a normal distribution. CONCLUSION: The proposed "proof-of-concept" GAMLSS-binning approach can improve diagnostic accuracy of 129 Xe gas-exchange MRI by providing a means of modeling voxel distribution data against age.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Criança , Humanos , Adolescente , Adulto Jovem , Pré-Escolar , Adulto , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Isótopos de Xenônio , Testes de Função Respiratória , Respiração , Eritrócitos
3.
Magn Reson Med ; 89(5): 2048-2061, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36576212

RESUMO

PURPOSE: The purpose of this study is to assess the intra- and interscan repeatability of free-breathing phase-resolved functional lung (PREFUL) MRI in stable pediatric cystic fibrosis (CF) lung disease in comparison to static breath-hold hyperpolarized 129-xenon MRI (Xe-MRI) and pulmonary function tests. METHODS: Free-breathing 1-hydrogen MRI and Xe-MRI were acquired from 15 stable pediatric CF patients and seven healthy age-matched participants on two visits, 1 month apart. Same-visit MRI scans were also performed on a subgroup of the CF patients. Following the PREFUL algorithm, regional ventilation (RVent) and regional flow volume loop cross-correlation maps were determined from the free-breathing data. Ventilation defect percentage (VDP) was determined from RVent maps (VDPRVent ), regional flow volume loop cross-correlation maps (VDPCC ), VDPRVent ∪ VDPCC , and multi-slice Xe-MRI. Repeatability was evaluated using Bland-Altman analysis, coefficient of repeatability (CR), and intraclass correlation. RESULTS: Minimal bias and no significant differences were reported for all PREFUL MRI and Xe-MRI VDP parameters between intra- and intervisits (all P > 0.05). Repeatability of VDPRVent , VDPCC , VDPRVent ∪ VDPCC , and multi-slice Xe-MRI were lower between the two-visit scans (CR = 14.81%, 15.36%, 16.19%, and 9.32%, respectively) in comparison to the same-day scans (CR = 3.38%, 2.90%, 1.90%, and 3.92%, respectively). pulmonary function tests showed high interscan repeatability relative to PREFUL MRI and Xe-MRI. CONCLUSION: PREFUL MRI, similar to Xe-MRI, showed high intravisit repeatability but moderate intervisit repeatability in CF, which may be due to inherent disease instability, even in stable patients. Thus, PREFUL MRI may be considered a suitable outcome measure for future treatment response studies.


Assuntos
Fibrose Cística , Humanos , Criança , Fibrose Cística/diagnóstico por imagem , Respiração , Pulmão/diagnóstico por imagem , Testes de Função Respiratória , Isótopos de Xenônio , Imageamento por Ressonância Magnética , Xenônio
4.
Magn Reson Med ; 90(6): 2420-2431, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37526031

RESUMO

PURPOSE: The underlying functional and microstructural lung disease in neonates who are born preterm (bronchopulmonary dysplasia, BPD) remains poorly characterized. Moreover, there is a lack of suitable techniques to reliably assess lung function in this population. Here, we report our preliminary experience with hyperpolarized 129 Xe MRI in neonates with BPD. METHODS: Neonatal intensive care patients with established BPD were recruited (N = 9) and imaged at a corrected gestational age of median:40.7 (range:37.1, 44.4) wk using a 1.5T neonatal scanner. 2D 129 Xe ventilation and diffusion-weighted images and dissolved phase spectroscopy were acquired, alongside 1 H 3D radial UTE. 129 Xe images were acquired during a series of short apneic breath-holds (˜3 s). 1 H UTE images were acquired during tidal breathing. Ventilation defects were manually identified and qualitatively compared to lung structures on UTE. ADCs were calculated on a voxel-wise basis. The signal ratio of the 129 Xe red blood cell (RBC) and tissue membrane (M) resonances from spectroscopy was determined. RESULTS: Spiral-based 129 Xe ventilation imaging showed good image quality and sufficient sensitivity to detect mild ventilation abnormalities in patients with BPD. 129 Xe ADC values were elevated above that expected given healthy data in older children and adults (median:0.046 [range:0.041, 0.064] cm2 s-1 ); the highest value obtained from an extremely pre-term patient. 129 Xe spectroscopy revealed a low RBC/M ratio (0.14 [0.06, 0.21]). CONCLUSION: We have demonstrated initial feasibility of 129 Xe lung MRI in neonates. With further data, the technique may help guide management of infant lung diseases in the neonatal period and beyond.


Assuntos
Displasia Broncopulmonar , Adulto , Recém-Nascido , Criança , Humanos , Displasia Broncopulmonar/diagnóstico por imagem , Estudos de Viabilidade , Isótopos de Xenônio , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
5.
J Magn Reson Imaging ; 58(3): 936-948, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36786650

RESUMO

BACKGROUND: Multiple-breath washout (MBW) 129 Xe MRI (MBW Xe-MRI) is a promising technique for following pediatric cystic fibrosis (CF) lung disease progression. However, its repeatability in stable CF needs to be established to use it as an outcome measure for novel therapies. PURPOSE: To assess intravisit and intervisit repeatability of MBW Xe-MRI in healthy and CF children. STUDY TYPE: Prospective, longitudinal cohort study. SUBJECTS: A total of 18 pediatric subjects (7 healthy, 11 CF). FIELD STRENGTH/SEQUENCE: A 3 T/2D coronal hyperpolarized (HP) 129 Xe images using GRE sequence. ASSESSMENT: All subjects completed MBW Xe-MRI, pulmonary function tests (PFTs) (spirometry, nitrogen [N2 ] MBW for lung clearance index [LCI]) and ventilation defect percent (VDP) at baseline (visit 1) and 1-month after. Fractional ventilation (FV), coefficient of variation (CoVFV ) maps were calculated from MBW Xe-MRI data acquired between intervening air washout breaths performed after an initial xenon breath-hold. Skewness of FV and CoVFV map distributions was also assessed. STATISTICAL TESTS: Repeatability: intraclass correlation coefficients (ICC), within-subject coefficient of variation (CV%), repeatability coefficient (CR). Agreement: Bland-Altman. For correlations between MBW Xe-MRI, VDP and PFTs: Spearman's correlation. Significance threshold: P < 0.05. RESULTS: For FV, intravisit median [IQR] ICC was high in both healthy (0.94 [0.48, 0.99]) and CF (0.83 [0.04, 0.97]) subjects. CoVFV also had good intravisit ICC in healthy (0.92 [0.42, 0.99]) and CF (0.79 [0.02, 0.96]) subjects. Similarly, for FV, intervisit ICC was high in health (0.94 [0.68, 0.99]) and CF (0.89 [0.61, 0.97]). CoVFV also had good intervisit ICC in health (0.92 [0.42, 0.99]) and CF (0.78 [0.26, 0.94]). FV had better intervisit repeatability than VDP. CoVFV correlated significantly with LCI (R = 0.56). Skewness of FV distributions significantly distinguished between cohorts at baseline. DATA CONCLUSION: MBW Xe-MRI had high intravisit and intervisit repeatability in healthy and stable CF subjects. CoVFV correlated with LCI, suggesting the importance of ventilation heterogeneity to early CF. EVIDENCE LEVEL: 1. TECHNICAL EFFICACY: Stage 2.


Assuntos
Fibrose Cística , Humanos , Criança , Fibrose Cística/diagnóstico por imagem , Xenônio , Estudos Prospectivos , Estudos Longitudinais , Testes de Função Respiratória/métodos , Pulmão/diagnóstico por imagem , Isótopos de Xenônio , Imageamento por Ressonância Magnética/métodos
6.
Pediatr Transplant ; 27(8): e14594, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37655840

RESUMO

RATIONALE: Organ size matching is an important determinant of successful allocation and outcomes in lung transplantation. While computed tomography (CT) is the gold standard, it is rarely used in an organ-donor context, and chest X-ray (CXR) may offer a practical and accurate solution in estimating lung volumes for donor and recipient size matching. We compared CXR lung measurements to CT-measured lung volumes and traditional estimates of lung volume in the same subjects. METHODS: Our retrospective study analyzed clinically obtained CXR and CT lung images of 250 subjects without evidence of lung disease (mean age 9.9 ± 7.8 years; 129 M/121F). From CT, each lung was semi-automatically segmented and total lung volumes were quantified. From anterior-posterior CXR view, each lung was manually segmented and areas were measured. Lung lengths from the apices to the mid-basal regions of each lung were measured from CXR. Quantified CT lung volumes were compared to the corresponding CXR lung lengths, CXR lung areas, height, weight, and predicted total lung capacity (pTLC). RESULTS: There are strong and significant correlations between CT volumes and CXR lung areas in the right lung (R2 = .89, p < .0001), left lung (R2 = .87, p < .0001), and combined lungs (R2 = .89, p < .0001). Similar correlations were seen between CT volumes and CXR measured lung lengths in the right lung (R2 = .79, p < .0001) and left lung (R2 = .81, p < .0001). This correlation between anatomical lung volume (CT) and CXR was stronger than lung-volume correlation to height (R2 = .66, p < .0001), weight (R2 = .43, p < .0001), or pTLC (R2 = .66, p < .0001). CONCLUSION: CXR measures correlate much more strongly with true lung volumes than height, weight, or pTLC. The ability to obtain efficient and more accurate lung volume via CXR has the potential to change our current listing practices of using height as a surrogate for lung size, with a case example provided.


Assuntos
Transplante de Pulmão , Pulmão , Humanos , Pré-Escolar , Criança , Adolescente , Estudos Retrospectivos , Raios X , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar/métodos , Transplante de Pulmão/métodos
7.
Circulation ; 144(7): 539-555, 2021 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-34111939

RESUMO

BACKGROUND: Pulmonary hypertension (PH) is a common complication in patients with alveolar capillary dysplasia with misalignment of pulmonary veins (ACDMPV), a severe congenital disorder associated with mutations in the FOXF1 gene. Although the loss of alveolar microvasculature causes PH in patients with ACDMPV, it is unknown whether increasing neonatal lung angiogenesis could prevent PH and right ventricular (RV) hypertrophy. METHODS: We used echocardiography, RV catheterization, immunostaining, and biochemical methods to examine lung and heart remodeling and RV output in Foxf1WT/S52F mice carrying the S52F Foxf1 mutation (identified in patients with ACDMPV). The ability of Foxf1WT/S52F mutant embryonic stem cells to differentiate into respiratory cell lineages in vivo was examined using blastocyst complementation. Intravascular delivery of nanoparticles with a nonintegrating Stat3 expression vector was used to improve neonatal pulmonary angiogenesis in Foxf1WT/S52F mice and determine its effects on PH and RV hypertrophy. RESULTS: Foxf1WT/S52F mice developed PH and RV hypertrophy after birth. The severity of PH in Foxf1WT/S52F mice directly correlated with mortality, low body weight, pulmonary artery muscularization, and increased collagen deposition in the lung tissue. Increased fibrotic remodeling was found in human ACDMPV lungs. Mouse embryonic stem cells carrying the S52F Foxf1 mutation were used to produce chimeras through blastocyst complementation and to demonstrate that Foxf1WT/S52F embryonic stem cells have a propensity to differentiate into pulmonary myofibroblasts. Intravascular delivery of nanoparticles carrying Stat3 cDNA protected Foxf1WT/S52F mice from RV hypertrophy and PH, improved survival, and decreased fibrotic lung remodeling. CONCLUSIONS: Nanoparticle therapies increasing neonatal pulmonary angiogenesis may be considered to prevent PH in ACDMPV.


Assuntos
Técnicas de Transferência de Genes , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Nanopartículas , Síndrome da Persistência do Padrão de Circulação Fetal/complicações , Alvéolos Pulmonares/anormalidades , Fator de Transcrição STAT3/genética , Remodelação das Vias Aéreas/genética , Animais , Biomarcadores , Modelos Animais de Doenças , Suscetibilidade a Doenças , Portadores de Fármacos , Sistemas de Liberação de Medicamentos , Ecocardiografia , Fibrose , Fatores de Transcrição Forkhead/deficiência , Terapia Genética , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/metabolismo , Hipertrofia Ventricular Direita/diagnóstico , Hipertrofia Ventricular Direita/etiologia , Hipertrofia Ventricular Direita/metabolismo , Camundongos , Camundongos Transgênicos , Densidade Microvascular/genética , Miofibroblastos/metabolismo , Síndrome da Persistência do Padrão de Circulação Fetal/genética , Síndrome da Persistência do Padrão de Circulação Fetal/patologia , Fator de Transcrição STAT3/administração & dosagem , Nanomedicina Teranóstica/métodos , Resultado do Tratamento , Remodelação Vascular/genética
8.
Eur Respir J ; 59(3)2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34266943

RESUMO

BACKGROUND: Chest computed tomography (CT) remains the imaging standard for demonstrating cystic fibrosis (CF) airway structural disease in vivo. However, visual scoring systems as an outcome measure are time consuming, require training and lack high reproducibility. Our objective was to validate a fully automated artificial intelligence (AI)-driven scoring system of CF lung disease severity. METHODS: Data were retrospectively collected in three CF reference centres, between 2008 and 2020, in 184 patients aged 4-54 years. An algorithm using three 2D convolutional neural networks was trained with 78 patients' CT scans (23 530 CT slices) for the semantic labelling of bronchiectasis, peribronchial thickening, bronchial mucus, bronchiolar mucus and collapse/consolidation. 36 patients' CT scans (11 435 CT slices) were used for testing versus ground-truth labels. The method's clinical validity was assessed in an independent group of 70 patients with or without lumacaftor/ivacaftor treatment (n=10 and n=60, respectively) with repeat examinations. Similarity and reproducibility were assessed using the Dice coefficient, correlations using the Spearman test, and paired comparisons using the Wilcoxon rank test. RESULTS: The overall pixelwise similarity of AI-driven versus ground-truth labels was good (Dice 0.71). All AI-driven volumetric quantifications had moderate to very good correlations to a visual imaging scoring (p<0.001) and fair to good correlations to forced expiratory volume in 1 s % predicted at pulmonary function tests (p<0.001). Significant decreases in peribronchial thickening (p=0.005), bronchial mucus (p=0.005) and bronchiolar mucus (p=0.007) volumes were measured in patients with lumacaftor/ivacaftor. Conversely, bronchiectasis (p=0.002) and peribronchial thickening (p=0.008) volumes increased in patients without lumacaftor/ivacaftor. The reproducibility was almost perfect (Dice >0.99). CONCLUSION: AI allows fully automated volumetric quantification of CF-related modifications over an entire lung. The novel scoring system could provide a robust disease outcome in the era of effective CF transmembrane conductance regulator modulator therapy.


Assuntos
Inteligência Artificial , Regulador de Condutância Transmembrana em Fibrose Cística , Adolescente , Adulto , Aminopiridinas/uso terapêutico , Criança , Pré-Escolar , Humanos , Pulmão/diagnóstico por imagem , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
9.
NMR Biomed ; 35(3): e4639, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34729838

RESUMO

RATIONALE: Hyperpolarized (HP) 129 Xe-MRI provides non-invasive methods to quantify lung function and structure, with the 129 Xe apparent diffusion coefficient (ADC) being a well validated measure of alveolar airspace size. However, the experimental factors that impact the precision and accuracy of HP 129 Xe ADC measurements have not been rigorously investigated. Here, we introduce an analytical model to predict the experimental uncertainty of 129 Xe ADC estimates. Additionally, we report ADC dependence on age in healthy pediatric volunteers. METHODS: An analytical expression for ADC uncertainty was derived from the Stejskal-Tanner equation and simplified Bloch equations appropriate for HP media. Parameters in the model were maximum b-value (bmax ), number of b-values (Nb ), number of phase encoding lines (Nph ), flip angle and the ADC itself. This model was validated by simulations and phantom experiments, and five fitting methods for calculating ADC were investigated. To examine the lower range for 129 Xe ADC, 32 healthy subjects (age 6-40 years) underwent diffusion-weighted 129 Xe MRI. RESULTS: The analytical model provides a lower bound on ADC uncertainty and predicts that decreased signal-to-noise ratio yields increases in relative uncertainty (ϵADC) . As such, experimental parameters that impact non-equilibrium 129 Xe magnetization necessarily impact the resulting ϵADC . The values of diffusion encoding parameters (Nb and bmax ) that minimize ϵADC strongly depend on the underlying ADC value, resulting in a global minimum for ϵADC . Bayesian fitting outperformed other methods (error < 5%) for estimating ADC. The whole-lung mean 129 Xe ADC of healthy subjects increased with age at a rate of 1.75 × 10-4  cm2 /s/yr (p = 0.001). CONCLUSIONS: HP 129 Xe diffusion MRI can be improved by minimizing the uncertainty of ADC measurements via uncertainty propagation. Doing so will improve experimental accuracy when measuring lung microstructure in vivo and should allow improved monitoring of regional disease progression and assessment of therapy response in a range of lung diseases.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Isótopos de Xenônio , Adolescente , Adulto , Fatores Etários , Criança , Difusão , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Razão Sinal-Ruído , Incerteza , Adulto Jovem
10.
J Magn Reson Imaging ; 56(4): 1207-1219, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35244302

RESUMO

BACKGROUND: 129 Xe gas-transfer MRI provides regional measures of pulmonary gas exchange in adults and separates xenon in interstitial lung tissue/plasma (barrier) from xenon in red blood cells (RBCs). The technique has yet to be demonstrated in pediatric populations or conditions. PURPOSE/HYPOTHESIS: To perform an exploratory analysis of 129 Xe gas-transfer MRI in children. STUDY TYPE: Prospective. POPULATION: Seventy-seven human volunteers (38 males, age = 17.7 ± 15.1 years, range 5-68 years, 16 healthy). Four pediatric disease cohorts. FIELD STRENGTH/SEQUENCE: 3-T, three-dimensional-radial one-point Dixon Fast Field Echo (FFE) Ultrashort Echo Time (UTE). ASSESSMENT: Breath hold compliance was assessed by quantitative signal-to-noise and dynamic metrics. Whole-lung means and standard deviations were extracted from gas-transfer maps. Gas-transfer metrics were investigated with respect to age and lung disease. Clinical pulmonary function tests were retrospectively acquired for reference lung disease severity. STATISTICAL TESTS: Wilcoxon rank-sum tests to compare age and disease cohorts, Wilcoxon signed-rank tests to compare pre- and post-breath hold vitals, Pearson correlations between age and gas-transfer metrics, and limits of normal with a binomial exact test to compare fraction of subjects with abnormal gas-transfer. P ≤ 0.05 was considered significant. RESULTS: Eighty percentage of pediatric subjects successfully completed 129 Xe gas-transfer MRI. Gas-transfer parameters differed between healthy children and adults, including ventilation (0.75 and 0.67) and RBC:barrier ratio (0.31 and 0.46) which also correlated with age (ρ = -0.76, 0.57, respectively). Bone marrow transplant subjects had impaired ventilation (90% of reference) and increased dissolved 129 Xe standard deviation (242%). Bronchopulmonary dysplasia subjects had decreased barrier-uptake (69%). Cystic fibrosis subjects had impaired ventilation (91%) and increased RBC-transfer (146%). Lastly, childhood interstitial lung disease subjects had increased ventilation heterogeneity (113%). Limits of normal provided detection of abnormalities in additional gas-transfer parameters. DATA CONCLUSION: Pediatric 129 Xe gas-transfer MRI was adequately successful and gas-transfer metrics correlated with age. Exploratory analysis revealed abnormalities in a variety of pediatric obstructive and restrictive lung diseases. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Pneumopatias , Isótopos de Xenônio , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Estudos de Viabilidade , Humanos , Imageamento Tridimensional/métodos , Recém-Nascido , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Xenônio , Adulto Jovem
11.
Am J Respir Crit Care Med ; 204(12): e115-e133, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34908518

RESUMO

Background: Premature birth affects millions of neonates each year, placing them at risk for respiratory disease due to prematurity. Bronchopulmonary dysplasia is the most common chronic lung disease of infancy, but recent data suggest that even premature infants who do not meet the strict definition of bronchopulmonary dysplasia can develop adverse pulmonary outcomes later in life. This post-prematurity respiratory disease (PPRD) manifests as chronic respiratory symptoms, including cough, recurrent wheezing, exercise limitation, and reduced pulmonary function. This document provides an evidence-based clinical practice guideline on the outpatient management of infants, children, and adolescents with PPRD. Methods: A multidisciplinary panel of experts posed questions regarding the outpatient management of PPRD. We conducted a systematic review of the relevant literature. The Grading of Recommendations, Assessment, Development, and Evaluation approach was used to rate the quality of evidence and the strength of the clinical recommendations. Results: The panel members considered the strength of each recommendation and evaluated the benefits and risks of applying the intervention. In formulating the recommendations, the panel considered patient and caregiver values, the cost of care, and feasibility. Recommendations were developed for or against three common medical therapies and four diagnostic evaluations in the context of the outpatient management of PPRD. Conclusions: The panel developed recommendations for the outpatient management of patients with PPRD on the basis of limited evidence and expert opinion. Important areas for future research were identified.


Assuntos
Doenças do Prematuro/terapia , Doenças Respiratórias/terapia , Adolescente , Assistência ao Convalescente , Criança , Doença Crônica , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro
12.
Pediatr Radiol ; 52(4): 643-660, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35122130

RESUMO

Bronchopulmonary dysplasia (BPD) is a common long-term complication of preterm birth. The chest radiograph appearance and survivability have evolved since the first description of BPD in 1967 because of improved ventilation and clinical strategies and the introduction of surfactant in the early 1990s. Contemporary imaging care is evolving with the recognition that comorbidities of tracheobronchomalacia and pulmonary hypertension have a great influence on outcomes and can be noninvasively evaluated with CT and MRI techniques, which provide a detailed evaluation of the lungs, trachea and to a lesser degree the heart. However, echocardiography remains the primary modality to evaluate and screen for pulmonary hypertension. This review is intended to highlight the important findings that chest radiograph, CT and MRI can contribute to precision diagnosis, phenotyping and prognosis resulting in optimal management and therapeutics.


Assuntos
Displasia Broncopulmonar , Hipertensão Pulmonar , Nascimento Prematuro , Displasia Broncopulmonar/diagnóstico por imagem , Feminino , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética/efeitos adversos , Gravidez , Tomografia Computadorizada por Raios X/efeitos adversos
13.
Pediatr Radiol ; 52(12): 2306-2318, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35556152

RESUMO

BACKGROUND: Pulmonary arterial hypertension, impaired cardiac function and lung hypoplasia are common in infants with congenital diaphragmatic hernia (CDH) and are associated with increased morbidity and mortality. Robust noninvasive methods to quantify these abnormalities in early infancy are lacking. OBJECTIVE: To determine the feasibility of MRI to quantify cardiopulmonary hemodynamics and function in infants with CDH and to investigate left-right blood flow and lung volume discrepancies. MATERIALS AND METHODS: We conducted a prospective MRI study of 23 neonates (isolated left CDH: 4 pre-repair, 7 post-repair, 3 pre- and post-repair; and 9 controls) performed on a small-footprint 1.5-tesla (T) scanner. We calculated MRI-based pulmonary arterial blood flow, left ventricular eccentricity index, cardiac function and lung volume. Using the Wilcoxon rank sum test for continuous data and Fisher exact test for categorical data, we made pairwise group comparisons. RESULTS: The right-to-left ratios for pulmonary artery blood flow and lung volume were elevated in pre-repair and post-repair CDH versus controls (flow: P<0.005; volume: P<0.05 pre-/post-repair). Eccentricity index at end-systole significantly differed between pre-repair and post-repair CDH (P<0.01) and between pre-repair CDH and controls (P<0.001). CONCLUSION: Cardiopulmonary MRI is a viable method to serially evaluate cardiopulmonary hemodynamics and function in critically ill infants and is useful for capturing left-right asymmetries in pulmonary blood flow and lung volume.


Assuntos
Hérnias Diafragmáticas Congênitas , Recém-Nascido , Lactente , Humanos , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Hérnias Diafragmáticas Congênitas/complicações , Estudos Prospectivos , Pulmão/anormalidades , Medidas de Volume Pulmonar , Imageamento por Ressonância Magnética/métodos
14.
J Allergy Clin Immunol ; 147(6): 2146-2153.e1, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33227317

RESUMO

BACKGROUND: Measurement of regional lung ventilation with hyperpolarized 129Xe magnetic resonance imaging (129Xe MRI) in pediatric asthma is poised to advance our understanding of disease mechanisms and pathophysiology in a disorder with diverse clinical phenotypes. 129Xe MRI has not been investigated in a pediatric asthma cohort. OBJECTIVE: We hypothesized that 129Xe MRI is feasible and can demonstrate ventilation defects that relate to and predict clinical severity in a pediatric asthma cohort. METHODS: Thirty-seven children (13 with severe asthma, 8 with mild/moderate asthma, 16 age-matched healthy controls) aged 6 to 17 years old were imaged with 129Xe MRI. Ventilation defect percentage (VDP) and image reader score were calculated and compared with clinical measures at baseline and at follow-up. RESULTS: Children with asthma had higher VDP (P = .002) and number of defects per image slice (defects/slice) (P = .0001) than children without asthma. Children with clinically severe asthma had significantly higher VDP and number of defects/slice than healthy controls. Children with asthma who had a higher number of defects/slice had a higher rate of health care utilization (r = 0.48; P = .03) and oral corticosteroid use (r = 0.43; P = .05) at baseline. Receiver-operating characteristic analysis demonstrated that the VDP and number of defects/slice were predictive of increased health care utilization, asthma, and severe asthma. VDP correlated with FEV1 (r = -0.35; P = .04) and FEV1/forced vital capacity ratio (r = -0.41; P = .01). CONCLUSIONS: 129Xe MRI correlates with asthma severity, health care utilization, and oral corticosteroid use. Because delineation of clinical severity is often difficult in children, 129Xe MRI may be an important biomarker for severity, with potential to identify children at higher risk for exacerbations and improve outcomes.


Assuntos
Asma/diagnóstico , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio , Adolescente , Asma/terapia , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Curva ROC , Testes de Função Respiratória , Índice de Gravidade de Doença
15.
Magn Reson Med ; 86(2): 907-915, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33665905

RESUMO

PURPOSE: Hyperpolarized xenon (129 Xe) gas-transfer imaging allows different components of pulmonary gas transfer-alveolar air space, lung interstitium/blood plasma (barrier), and red blood cells (RBCs)-to be assessed separately in a single breath. However, quantitative analysis is challenging because dissolved-phase 129 Xe images are often contaminated by off-resonant gas-phase signal generated via imperfectly selective excitation. Although previous methods required additional data for gas-phase removal, the method reported here requires no/minimal sequence modifications/data acquisitions, allowing many previously acquired images to be corrected retroactively. METHODS: 129 Xe imaging was implemented at 3.0T via an interleaved three-dimensional radial acquisition of the gaseous and dissolved phases (using one-point Dixon reconstruction for the dissolved phase) in 46 human subjects and a phantom. Gas-phase contamination (9.5% ± 4.8%) was removed from gas-transfer data using a modified gas-phase image. The signal-to-noise ratio (SNR) and signal distributions were compared before and after contamination removal. Additionally, theoretical gaseous contaminations were simulated at different magnetic field strengths for comparison. RESULTS: Gas-phase contamination at 3.0T was more diffuse and located predominantly outside the lungs, relative to simulated 1.5T contamination caused by the larger frequency offset. Phantom experiments illustrated a 91% removal efficiency. In human subjects, contamination removal produced significant changes in dissolved signal SNR (+7.8%), mean (-1.4%), and standard deviation (-2.3%) despite low contamination. Repeat measurements showed reduced variance (dissolved mean, -1.0%; standard deviation, -8.4%). CONCLUSION: Off-resonance gas-phase contamination can be removed robustly with no/minimal sequence modifications. Contamination removal permits more accurate quantification, reduces radiofrequency stringency requirements, and increases data consistency, providing improved sensitivity needed for multicenter trials.


Assuntos
Artefatos , Isótopos de Xenônio , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Xenônio
16.
Magn Reson Med ; 85(4): 2160-2173, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33017076

RESUMO

PURPOSE: Diffusion and lung morphometry imaging using hyperpolarized gases are promising tools to quantify pulmonary microstructure noninvasively in humans and in animal models. These techniques assume the motion encoded is exclusively diffusive gas displacement, but the impact of cardiac motion on measurements has never been explored. Furthermore, although diffusion morphometry has been validated against histology in humans and mice using 3 He, it has never been validated in mice for 129 Xe. Here, we examine the effect of cardiac motion on diffusion imaging and validate 129 Xe diffusion morphometry in mice. THEORY AND METHODS: Mice were imaged using gradient-echo-based diffusion imaging, and apparent diffusion-coefficient (ADC) maps were generated with and without cardiac gating. Diffusion-weighted images were fit to a previously developed theoretical model using Bayesian probability theory, producing morphometric parameters that were compared with conventional histology. RESULTS: Cardiac gating had no significant impact on ADC measurements (dual-gating: ADC = 0.020 cm2 /s, single-gating: ADC = 0.020 cm2 /s; P = .38). Diffusion-morphometry-generated maps of ADC (mean, 0.0165 ± 0.0001 cm2 /s) and acinar dimensions (alveolar sleeve depth [h] = 44 µm, acinar duct radii [R] = 99 µm, mean linear intercept [Lm ] = 74 µm) that agreed well with conventional histology (h = 45 µm, R = 108 µm, Lm = 63 µm). CONCLUSION: Cardiac motion has negligible impact on 129 Xe ADC measurements in mice, arguing its impact will be similarly minimal in humans, where relative cardiac motion is reduced. Hyperpolarized 129 Xe diffusion morphometry accurately and noninvasively maps the dimensions of lung microstructure, suggesting it can quantify the pulmonary microstructure in mouse models of lung disease.


Assuntos
Imagem de Difusão por Ressonância Magnética , Isótopos de Xenônio , Animais , Teorema de Bayes , Difusão , Hélio , Pulmão/diagnóstico por imagem , Masculino , Camundongos
17.
Magn Reson Med ; 86(6): 2966-2986, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34478584

RESUMO

Hyperpolarized (HP) 129 Xe MRI uniquely images pulmonary ventilation, gas exchange, and terminal airway morphology rapidly and safely, providing novel information not possible using conventional imaging modalities or pulmonary function tests. As such, there is mounting interest in expanding the use of biomarkers derived from HP 129 Xe MRI as outcome measures in multi-site clinical trials across a range of pulmonary disorders. Until recently, HP 129 Xe MRI techniques have been developed largely independently at a limited number of academic centers, without harmonizing acquisition strategies. To promote uniformity and adoption of HP 129 Xe MRI more widely in translational research, multi-site trials, and ultimately clinical practice, this position paper from the 129 Xe MRI Clinical Trials Consortium (https://cpir.cchmc.org/XeMRICTC) recommends standard protocols to harmonize methods for image acquisition in HP 129 Xe MRI. Recommendations are described for the most common HP gas MRI techniques-calibration, ventilation, alveolar-airspace size, and gas exchange-across MRI scanner manufacturers most used for this application. Moreover, recommendations are described for 129 Xe dose volumes and breath-hold standardization to further foster consistency of imaging studies. The intention is that sites with HP 129 Xe MRI capabilities can readily implement these methods to obtain consistent high-quality images that provide regional insight into lung structure and function. While this document represents consensus at a snapshot in time, a roadmap for technical developments is provided that will further increase image quality and efficiency. These standardized dosing and imaging protocols will facilitate the wider adoption of HP 129 Xe MRI for multi-site pulmonary research.


Assuntos
Pulmão , Isótopos de Xenônio , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Multicêntricos como Assunto , Ventilação Pulmonar , Respiração
18.
J Pediatr ; 239: 89-94, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34339729

RESUMO

OBJECTIVES: To assess the feasibility of magnetic resonance imaging (MRI) for postnatal assessment of pulmonary vascularity in infants with congenital diaphragmatic hernia (CDH). STUDY DESIGN: Infants with prenatally diagnosed CDH (n = 24) received postnatal pulmonary MRI. Infants with nonpulmonary birth defects served as controls (n = 5). Semiautomatic segmentation was performed to obtain total vascular volume using time of flight images to assess vascularity. RESULTS: Average vascular density (vascular volume/lung volume) in control infants was 0.23 ± 0.06 mm3/mm3 compared with 0.18 ± 0.06 mm3/mm3 in infants with CDH is (P = .09). When stratified further based on CDH severity, the difference between control infants and moderate CDH group was statistically significant. (0.23 mm3/mm3 vs 0.15 mm3/mm3, P = .01). Ipsilateral vascular density on MRI in infants with CDH significantly correlated with the prenatal pulmonary hypertensive index (P = .0004, Spearman R = +0.87) and with number of days on mechanical ventilation (P = .04, Spearman R = -0.44), total days on inhaled nitric oxide (P = .02, Spearman R = -0.47), use of epoprostenol for acute pulmonary hypertension (PH) (0.14 mm3/mm3 vs 0.20 mm3/mm3, P = .005), and use of sildenafil for chronic PH (0.15 mm3/mm3 vs 0.19 mm3/mm3, P = .03). CONCLUSIONS: Our results suggest that postnatal pulmonary vascularity assessed by MRI strongly correlates with prenatal and postnatal markers of PH severity and that pulmonary vascularity may serve as a direct measure of pulmonary vascular hypoplasia in infants with CDH.


Assuntos
Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Medidas de Volume Pulmonar/métodos , Estudos de Casos e Controles , Feminino , Humanos , Recém-Nascido , Estudos Longitudinais , Imageamento por Ressonância Magnética/métodos , Masculino , Índice de Gravidade de Doença
19.
J Magn Reson Imaging ; 53(6): 1853-1861, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33404085

RESUMO

Infants admitted to the neonatal intensive care unit (NICU) often suffer from multifaceted pulmonary morbidities that are not well understood. Ultrashort echo time (UTE) magnetic resonance imaging (MRI) is a promising technique for pulmonary imaging in this population without requiring exposure to ionizing radiation. The aims of this study were to investigate the effect of neonatal pulmonary disease on R2 * and tissue density and to utilize numerical simulations to evaluate the effect of different alveolar structures on predicted R2 *.This was a prospective study, in which 17 neonatal human subjects (five control, seven with bronchopulmonary dysplasia [BPD], five with congenital diaphragmatic hernia [CDH]) were enrolled. Twelve subjects were male and five were female, with postmenstrual age (PMA) at MRI of 39.7 ± 4.7 weeks. A 1.5T/multiecho three-dimensional UTE MRI was used. Pulmonary R2 * and tissue density were compared across disease groups over the whole lung and regionally. A spherical shell alveolar model was used to predict the expected R2 * over a range of tissue densities and tissue susceptibilities. Tests for significantly different mean R2 * and tissue densities across disease groups were evaluated using analysis of variance, with subsequent pairwise group comparisons performed using t tests. Lung tissue density was lower in the ipsilateral lung in CDH compared to both controls and BPD patients (both p < 0.05), while only the contralateral lung in CDH (CDHc) had higher whole-lung R2 * than both controls and BPD (both p < 0.05). R2 * differences were significant between controls and CDHc within all tissue density ranges (all p < 0.05) with the exception of the 80%-90% range (p = 0.17). Simulations predicted an inverse relationship between alveolar tissue density and R2 * that matches empirical human data. Alveolar wall thickness had no effect on R2 * independent of density (p = 1). The inverse relationship between R2 * and tissue density is influenced by the presence of disease globally and regionally in neonates with BPD and CDH in the NICU. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 2.


Assuntos
Displasia Broncopulmonar , Pulmão , Displasia Broncopulmonar/diagnóstico por imagem , Pré-Escolar , Feminino , Humanos , Imageamento Tridimensional , Lactente , Recém-Nascido , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos
20.
Am J Respir Crit Care Med ; 202(7): 1024-1031, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32459506

RESUMO

Rationale: Bronchopulmonary dysplasia is a heterogeneous lung disease characterized by regions of cysts and fibrosis, but methods for evaluating lung function are limited to whole lung rather than specific regions of interest.Objectives: Respiratory-gated, ultrashort echo time magnetic resonance imaging was used to test the hypothesis that cystic regions of the lung will exhibit a quantifiable Vt that will correlate with ventilator settings and clinical outcomes.Methods: Magnetic resonance images of 17 nonsedated, quiet-breathing infants with severe bronchopulmonary dysplasia were reconstructed into end-inspiration and end-expiration images. Cysts were identified and measured by using density threshold combined with manual identification and segmentation. Regional Vts were calculated by subtracting end-expiration from end-inspiration volumes in total lung, noncystic lung, total-cystic lung, and individual large cysts.Measurements and Main Results: Cystic lung areas averaged larger Vts than noncystic lung when normalized by volume (0.8 ml Vt/ml lung vs. 0.1 ml Vt/ml lung, P < 0.002). Cyst Vt correlates with cyst size (P = 0.012 for total lung cyst and P < 0.002 for large cysts), although there was variability between individual cyst Vt, with 22% of cysts demonstrating negative Vt. Peak inspiratory pressure positively correlated with total lung Vt (P = 0.027) and noncystic Vt (P = 0.015) but not total lung cyst Vt (P = 0.8). Inspiratory time and respiratory rate did not improve Vt of any analyzed lung region.Conclusions: Cystic lung has greater normalized Vt when compared with noncystic lung. Ventilator pressure increases noncystic lung Vt, but inspiratory time does not correlate with Vt of normal or cystic lung.


Assuntos
Displasia Broncopulmonar/diagnóstico por imagem , Cistos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Respiração Artificial/métodos , Volume de Ventilação Pulmonar/fisiologia , Displasia Broncopulmonar/fisiopatologia , Displasia Broncopulmonar/terapia , Cistos/fisiopatologia , Feminino , Humanos , Imageamento Tridimensional , Lactente , Lactente Extremamente Prematuro , Recém-Nascido , Masculino , Técnicas de Imagem de Sincronização Respiratória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA