Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Dig Endosc ; 34(6): 1214-1221, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35108413

RESUMO

OBJECTIVES: Ultrasound speed (USS) correction improves image quality by estimating the optimal USS correcting the deviation from a predetermined USS. This study assessed USS differences between chronic pancreatitis (CP), early CP (ECP), and normal pancreas when using endoscopic ultrasound (EUS). The usefulness of measuring optimal USS was evaluated for patients with CP, including early stage patients. METHODS: This study enrolled 116 consecutive patients for whom USS was measured using an EUS system. The USS correction principle is generation of a B-mode image by changing the USS in all ranges while correcting the delay in the received data. Final diagnoses were made according to the Japanese diagnostic criteria for CP in 2019. They were classified as CP, ECP, or normal. We compared USS applied for these three groups. RESULTS: The medians and ranges of USS values for patients in the normal, ECP, and CP groups were 1506.0 (1407-1600) m/s, 1580.0 (1520-1630) m/s, and 1574.0 (1537-1610) m/s, respectively. The USS values of the ECP and CP groups were significantly higher than those of the normal group (P < 0.001). Analyses of the receiver operating characteristic curve in the normal pancreas, ECP, and CP revealed the area as 0.957, with specificity and sensitivity of 95.9% and 87.5%, respectively, using the USS of 1535 m/s as a cut-off. CONCLUSION: Measurement of USS might be particularly useful for distinguishing between normal and ECP imaging.


Assuntos
Pancreatite Crônica , Endossonografia , Humanos , Pancreatite Crônica/diagnóstico por imagem , Curva ROC , Ultrassonografia
2.
Medicina (Kaunas) ; 58(3)2022 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-35334586

RESUMO

A 60-year-old woman was diagnosed with nonfunctional pancreatic neuroendocrine neoplasm with multiple liver metastases and was administered everolimus. Due to persistent epigastric pain and diarrhea, a colonoscopy was performed on the 14th day after the start of everolimus administration, which revealed small bleeding ulcers in the ileocecal region, transverse colon, and rectum. These adverse effects were attributed to the everolimus; it was immediately discontinued, and the patient's clinical symptoms and imaging findings improved. We concurred that the administration of calcium channel blockers resulted in the inhibition of everolimus metabolism and the disease onset. The everolimus was discontinued. There was no subsequent recurrence of hemorrhagic colitis.


Assuntos
Antineoplásicos , Colite , Neoplasias Pancreáticas , Antineoplásicos/uso terapêutico , Colite/induzido quimicamente , Everolimo/efeitos adversos , Feminino , Hemorragia Gastrointestinal/induzido quimicamente , Humanos , Pessoa de Meia-Idade , Neoplasias Pancreáticas/complicações , Neoplasias Pancreáticas/tratamento farmacológico
3.
Digestion ; 102(2): 289-297, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-31801132

RESUMO

BACKGROUND: The diagnosis of chronic pancreatitis (CP) using endoscopic ultrasound (EUS) criteria, referred to as the Rosemont classification (RC), has been widely performed. However, the validity of the RC, which was based on expert opinion, is still controversial. If EUS findings are associated with CP, then they should be associated with risk factors for CP. In this study, to verify the appropriateness of the RC and each EUS finding, we performed a retrospective analysis from the viewpoint of risk factors for CP. SUMMARY: Three hundred and forty-four patients were enrolled in this study. Clinical background characteristics that associate with CP were alcohol intake, smoking, history of acute pancreatitis (AP), and age. The correlation between EUS criteria for CP and clinical background was investigated. All EUS findings except the presence of cysts showed significant correlations with one or 2 of the 3 following factors: ethanol (EtOH) intake, smoking status, and history of AP. Results of the univariate and multivariate analyses showed that 3 factors (EtOH intake, smoking, and history of AP) other than age were positively correlated with the RC. Moreover, the risk of progression from normal to consistent CP to indeterminate and suggestive CP was found to increase with increasing EtOH intake. Key Messages: The RC and each EUS finding was validated from the viewpoint of risk factors for CP.


Assuntos
Pancreatite Crônica , Doença Aguda , Endossonografia , Humanos , Pancreatite Crônica/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco
4.
Dig Endosc ; 32(7): 1100-1104, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32147871

RESUMO

The purpose of the present study is to report our experience of endoscopic ultrasound-guided coil deployment with sclerotherapy (EUS-CS) for isolated gastric varices (IGV) through a case series. Eight consecutive patients who had risky IGV were prospectively enrolled. EUS-CS was performed according to the following procedures: (i) several coils were first deployed in the IGV under EUS guidance; (ii) contrast medium was subsequently injected without removing the needle; (iii) if the infused contrast medium stayed in the IGV and feeding vein, sclerosant was then injected to obliterate the IGV and feeders. Coil deployment in the IGV was successfully performed in all cases. Sclerosant was injected both into the IGV and feeders in seven patients (87.5%). There was no adverse event during the procedure. During a median follow-up of 57 months, one patient who could not inject the sclerosant into IGV and feeders had an early hemorrhagic recurrence. Our case series showed that EUS-CS could be a feasible and safe procedure for the treatment of IGV.


Assuntos
Varizes Esofágicas e Gástricas , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Varizes Esofágicas e Gástricas/terapia , Estudos de Viabilidade , Seguimentos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Humanos , Escleroterapia/efeitos adversos , Resultado do Tratamento , Ultrassonografia de Intervenção
5.
Dig Endosc ; 32(1): 114-126, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31166046

RESUMO

OBJECTIVES: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for solid pancreatic lesions has high diagnostic yield. However, few prospective multicenter studies have been performed. We performed a prospective cohort study to evaluate the efficacy and safety of EUS-FNA for diagnosis of solid pancreatic lesions. METHODS: This prospective cohort study involved five hospitals in Japan. The primary outcome was sensitivity of EUS-FNA for diagnosing malignant lesions. We also evaluated parameters of diagnostic sufficiency and the safety of EUS-FNA. RESULTS: In total, 246 patients were enrolled. The absolute values of the parameters evaluated showed no significant differences; however, the percentage changes in the white blood cell counts and C-reactive protein levels after examination were significantly higher, and the percentage change in hemoglobin concentrations was significantly lower. The minor and major complication rates at the time of puncture, 24 h, 7 days and 28 days were 4.1%, 2.8%, 1.6%, and 0.0%, respectively. The true complication rate was 1.2%. The diagnostic sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 97.2%, 88.0%, 96.2%, 100%, and 81.4%, respectively. CONCLUSIONS: EUS-FNA for solid pancreatic lesions has high diagnostic yield and is safe, consistent with previously studies.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Pâncreas/patologia , Neoplasias Pancreáticas/patologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatopatias/patologia , Estudos Prospectivos , Resultado do Tratamento
6.
J Clin Med ; 12(8)2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37109253

RESUMO

INTRODUCTION: Wire-guided cannulation (WGC) during endoscopic retrograde cholangiopancreatography (ERCP) is a selective biliary cannulation technique aimed at improving the successful selective biliary cannulation rate and reducing the rate of post-ERCP pancreatitis (PEP) incidence. This study aimed to evaluate the effectiveness of angled-tip guidewires (AGW) vs. straight-tip guidewires (SGW) for biliary cannulation via WGC by a trainee. METHODS: We conducted a prospective, single-center, open-labeled, randomized, and controlled trial. Fifty-seven patients were enrolled in this study and assigned randomly to two groups (Group A to S and Group S to A). In this study, we started selective biliary cannulation via WGC with an AGW or an SGW for 7 min. If cannulation was unsuccessful, the other guidewire was used, and cannulation was continued for another 7 min (cross-over method). RESULTS: The selective biliary cannulation success rate over 14 min was significantly higher with an AGW compared with an SGW over 14 min (57.8% vs. 34.3%, p = 0.04) and for the second 7-min segment (36.4% vs. 0%, p = 0.04). No significant difference was found for adverse events such as pancreatitis between the two guidewires. CONCLUSIONS: Our results suggest that an AGW is recommended for WGC performed by a trainee.

8.
Healthcare (Basel) ; 10(7)2022 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-35885720

RESUMO

Red color sign-positive (RC-positive) esophageal varices present a high bleeding risk, necessitating prophylactic treatment. Among RC-positive esophageal varices, those classified morphologically as small straight varices (Form level 1: F1) are difficult to treat. Moreover, the appropriate time for therapeutic intervention remains undefined. This study assessed the bleeding risk in RC-positive F1 esophageal varices. After extracting 541 cases of F1 esophageal varices diagnosed during 1 January 2012−29 February 2020, 76 cases of RC-positive F1 esophageal varices were divided into two groups in terms of treatment intervention at diagnosis: 49 cases with (treatment group) and 27 cases without (follow-up group). We assessed the bleeding rates, bleeding-associated factors, and early-bleeding-associated factors. The treatment group's bleeding rate was 10% (5/49). The follow-up group's bleeding rate was 78% (21/24). The subsequent bleeding rate was low in the treatment group (p < 0.001). The median period of sustained absence of bleeding was longer in the treatment group than in the follow-up group (1156 [274−1582] days vs. 105 [1−336] days; p < 0.001). In the follow-up group, a significant number of bleedings had varices that included a hematocystic spot (HCS) as RC or combined with RC (p = 0.017). Early bleeding occurred often in varices that included HCS or combined with RC (p = 0.024). Red wale marking (RWM) only was not a factor of early bleeding (p = 0.012). In conclusion, RC-positive varices should be treated even as F1 varices. Patients with RWM only show the possibility of not accepting early treatment intervention. A fast response is crucially important in HCS cases because of its associated bleeding and early bleeding.

9.
J Hepatobiliary Pancreat Sci ; 29(12): 1274-1282, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34826207

RESUMO

BACKGROUND/PURPOSE: The aim of this study is to clarify the relation between the incision size for endoscopic sphincterotomy (EST) and common bile duct stone (CBDS) recurrence. METHODS: Patients who underwent elective endoscopic treatment for CBDS between January 2013 and December 2017 were enrolled, excluding those who met the exclusion criteria. The clinical characteristics were investigated using propensity score matching analysis. RESULTS: A total of 243 patients were investigated. Propensity scores were calculated using multinomial logistic regression with five relevant variables (age, gender, follow-up time, maximum stone size, and bile duct diameter), which led to extraction of 188 cases to compose cohorts of the small and medium EST incision groups. The CBDS recurrence rate was 17.0% in the small incision group and 6.4% in the medium incision group. Multivariate analysis identified the medium incision as an independent predictor of CBDS recurrence (hazard ratio 0.350, 95% confidence interval 0.133-0.922, P = .034). The CBDS non-recurrence rate of the medium incision group was significantly higher than that of the small incision group (log-rank test P = .019). CONCLUSIONS: Our findings suggest that the CBDS recurrence rate was lower in EST with medium incision size than with small incision size.


Assuntos
Coledocolitíase , Cálculos Biliares , Humanos , Esfinterotomia Endoscópica , Colangiopancreatografia Retrógrada Endoscópica , Pontuação de Propensão , Coledocolitíase/cirurgia , Fatores de Risco , Estudos Retrospectivos , Cálculos Biliares/cirurgia , Ducto Colédoco/cirurgia , Resultado do Tratamento
10.
Intern Med ; 61(3): 291-301, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34373374

RESUMO

Objective To evaluate the effectiveness and safety of the double-guidewire technique (DGT) using a new double-guidewire-supported sphincterotome (MagicTome) for patients who required endoscopic retrograde cholangiopancreatography (ERCP) for biliary cannulation. Methods This prospective multicenter randomized feasibility trial involved patients with difficult biliary cannulation at any of the three study sites from June 2017 to October 2018. Patients were assigned to the DGT with MagicTome (MDGT) initially performed group and the conventional DGT (CDGT) initially performed group. The success rates of biliary cannulation by MDGT and CDGT and the ERCP-related complications were evaluated. Results Twenty-eight patients were included in this study. No significant difference was observed in the success rates of first attempts and crossover attempts between the groups (p=0.69 and p=1.00). Furthermore, no significant difference was observed in the success rate of biliary cannulation between MDGT and CDGT (62.5% and 75.0%, respectively; p=0.48). CDGT was successful in two of four patients with malignant biliary obstruction. MDGT was successful in all four patients with malignant biliary obstruction, including the two for whom CDGT was unsuccessful. Post-ERCP pancreatitis occurred in only one MDGT case. Conclusion MDGT is safe for biliary cannulation and can be used in cases where biliary cannulation by CDGT is difficult.


Assuntos
Cateterismo , Pancreatite , Cateterismo/efeitos adversos , Cateterismo/métodos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Estudos de Viabilidade , Humanos , Pancreatite/etiologia , Estudos Prospectivos
12.
J Clin Med ; 10(14)2021 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-34300215

RESUMO

A prospective study was conducted in patients with early-stage gastric cancer to determine the efficacy and safety of acupuncture stimulation as an antispasmodic compared with conventional medication during the procedure of endoscopic submucosal dissection (ESD) of the upper gastrointestinal tract. This study was a prospective single blinded quasi-randomized controlled trial. Seventy-three patients who were scheduled to undergo ESD for gastric cancer at Aizu Medical Center between 19 February 2016 and 30 June 2016 were assessed for eligibility for the study. Sixty out of 73 patients were included in the study and assigned into two intervention groups: medication group (MG) and acupuncture group (AG). Ease of the procedure was evaluated using modified NIWA classification (MNC) by endoscopist considering the frequency and amplitude of the upper gastrointestinal peristalsis. For the statistical analysis, Mann-Whitney test was used to compare the differences of MNC values (baseline and end of procedure) between two groups. The difference of MNC found in the AG (-2.00 (-3.0 to -2.0)) was significantly greater than that in the MG (-1.00 (-2.0 to -1.0), p < 0.0001, Mann-Whitney test). We consider that acupuncture to the abdomen could be an alternative antispasmodic method during upper gastrointestinal endoscopic procedure.

13.
J Clin Med ; 10(16)2021 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-34442035

RESUMO

Ultrasonographic elastography is a modality used to visualize the elastic properties of tissues. Technological advances in ultrasound equipment have supported the evaluation of elastography (EG) in endosonography (EUS). Currently, the usefulness of not only EUS-strain elastography (EUS-SE) but also EUS-shear wave elastography (EUS-SWE) has been reported. We reviewed the literature on the usefulness of EUS-EG for various diseases such as chronic pancreatitis, pancreatic solid lesion, autoimmune pancreatitis, lymph node, and gastrointestinal and subepithelial lesions. The importance of this new diagnostic parameter, "tissue elasticity" in clinical practice might be applied not only to the diagnosis of liver fibrosis but also to the elucidation of the pathogeneses of various gastrointestinal diseases, including pancreatic diseases, and to the evaluation of therapeutic effects. The most important feature of EUS-EG is that it is a non-invasive modality. This is an advantage not found in EUS-guided fine needle aspiration (EUS-FNA), which has made remarkable progress in the field of diagnostics in recent years. Further development of artificial intelligence (AI) is expected to improve the diagnostic performance of EUS-EG. Future research on EUS-EG is anticipated.

14.
Biomed Mater Eng ; 32(2): 63-71, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33720871

RESUMO

BACKGROUND: Endoscopic transpapillary stenting is commonly performed in patients with obstructive jaundice caused by a biliary stricture. Although the plastic stent (PS) is widely used for biliary drainage because of the low-cost and easy procedure, patency is short after placement in the bile duct because of the small diameter. Dysfunction of PS is primarily caused by biliary sludge that forms as a result of bacterial adhesion and subsequent biofilm formation on the inner surface of the stent. It is well known that silver ions have excellent antibacterial activity against a wide range of microorganisms. OBJECTIVE: This review provides an overview and perspective of the significance of silver-coated biliary stents. METHODS: We collected literature regarding silver-coated biliary stents, reviewed the current research/development status and discussed their possible usefulness. RESULTS: To date, several in vivo/vitro studies evaluated the patency of silver-blended or silver-coated biliary stents. These studies suggested that the silver coating on a PS was likely to prolong the patency period. CONCLUSION: The development of biliary stents using silver is expected to prolong stent patency and prevent frequent stent replacement.


Assuntos
Prata , Antibacterianos , Colestase , Drenagem , Humanos , Stents , Resultado do Tratamento
15.
Diagnostics (Basel) ; 11(3)2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33802623

RESUMO

In 2009, diagnostic criteria for early chronic pancreatitis (DCECP2009) were proposed by the Japan Pancreas Society. This study aimed to evaluate the interobserver reliability (IOR) of endoscopic ultrasound (EUS) criteria for diagnosis of early chronic pancreatitis (ECP) between DCECP2009 and 2019 diagnostic criteria for ECP (DCECP2019) to assess the validity of the revision from the perspective of EUS findings. Among patients who underwent a detailed observation of the pancreas by EUS at our institution between January 2018 and March 2019, EUS images of 97 patients were extracted. Images were reviewed by 12 gastrointestinal endoscopy experts (eight pancreatologists, group A and four nonpancreatologists, group B). The overall kappa (K)-values for the IOR of the DCECP2009 EUS criteria were 0.424 and 0.563:0.231 for groups A:B, whereas the overall K-values for the DCECP2019 criteria were 0.618, and 0.733:0.442 for groups A:B. Regarding changes in the final diagnosis of ECP based on clinical features and EUS findings, 20 cases were definite ECP, 53 were probable ECP, and 24 were normal according to DCECP2009. In contrast, seven were definite ECP, 19 were probable ECP, and 71 were normal according to DECEP2019. IOR of DCECP2019 was higher than that of DCECP2009, which indicates an improvement in precision.

16.
J Clin Med ; 10(5)2021 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-33800779

RESUMO

Success rates of balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography (BE-ERCP) for patients with a reconstructed intestinal tract after surgical procedures are unsatisfactory. We retrospectively investigated the factors associated with unsuccessful BE-ERCP. Ninety-one patients who had a reconstructed intestinal tract after gastrectomy or choledochojejunostomy were enrolled. Age, sex, operative method, malignancy, endoscope type, endoscopist's skill, emergency procedure, and time required to reach the papilla/anastomosis were examined. The primary endpoints were the factors associated with unsuccessful BE-ERCP selective cannulation, while the secondary endpoints were the rate of reaching the papilla/anastomosis, causes of failure to reach the papilla/anastomosis, cannulation success rate, procedure success rate, and rate of adverse events. Younger age (odds ratio, 0.832; 95% CI, 0.706-0.982; p = 0.001) and Roux-en-Y partial gastrectomy (odds ratio, 54.9; 95% CI, 1.09-2763; p = 0.045) were associated with unsuccessful BE- ERCP. The rate of reaching the papilla/anastomosis was 92.3%, the success rate of biliary duct cannulation was 90.5%, procedure success rate was 78.0%, and the rate of adverse events was 5.6%. In conclusion, Roux-en-Y partial gastrectomy and younger age were associated with unsuccessful BE-ERCP. If BE-ERCP is extremely difficult to perform in such patients after Roux-en-Y partial gastrectomy, alternative procedures should be considered early.

17.
Intern Med ; 59(21): 2725-2728, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32669492

RESUMO

A 78-year-old man had been undergoing treatment with Cefamezin for pyogenic spondylitis. Because of complication of a urinary tract infection, the medication was switched to ceftriaxone (CTRX) 2 g/day. On day 18 after starting CTRX, the patient began experiencing abdominal pain. Computed tomography (CT) and endoscopic ultrasound led to the identification of calculi in the gallbladder and extrahepatic bile duct with a peculiar formation. We suspected CTRX-associated pseudo-cholecystolithiasis and pseudo-choledocholithiasis, although CT performed at admission had shown no such findings. Therefore, CTRX was discontinued. By day 17 after CTRX cessation, both the pseudo-cholecystolithiasis and pseudo-choledocholithiasis had disappeared.


Assuntos
Antibacterianos/efeitos adversos , Ductos Biliares Extra-Hepáticos/fisiopatologia , Ceftriaxona/efeitos adversos , Colecistolitíase/induzido quimicamente , Coledocolitíase/induzido quimicamente , Doenças da Vesícula Biliar/induzido quimicamente , Cálculos Renais/induzido quimicamente , Idoso , Antibacterianos/uso terapêutico , Cefazolina/uso terapêutico , Ceftriaxona/uso terapêutico , Colecistolitíase/terapia , Coledocolitíase/terapia , Humanos , Cálculos Renais/diagnóstico , Masculino , Espondilite/tratamento farmacológico , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Clin Med Insights Case Rep ; 13: 1179547620919453, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32425628

RESUMO

An 83-year-old man was referred to our hospital for a detailed evaluation for vomiting. Esophagogastroduodenoscopy and abdominal computed tomography showed duodenal stenosis with wall thickness. Biopsy including endoscopic ultrasound-guided fine-needle aspiration of the thickened wall showed inflammation without malignancy. During the clinical course, wall thickening of the distal bile duct appeared. Biopsy under endoscopic retrograde cholangiography showed papillary adenocarcinoma. Surgery revealed that the tumor had widely invaded the duodenal wall from the outside; therefore, only gastrojejunostomy was performed. It was hypothesized that the cholangiocarcinoma had progressed to the serosal side, disseminated in the peritoneum, infiltrated the duodenal serosa, and caused duodenal stenosis.

19.
Diagnostics (Basel) ; 10(11)2020 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-33203069

RESUMO

Endoscopic ultrasonography (EUS) has been applied to the diagnosis of various digestive disorders. Although it has been widely accepted and its diagnostic value is high, the dependence of EUS diagnosis on image interpretation done by the endosonographer has persisted as an important difficulty. Consequently, high interobserver reliability (IOR) in EUS diagnosis is important to demonstrate the reliability of EUS diagnosis. We reviewed the literature on the IOR of EUS diagnosis for various diseases such as chronic pancreatitis, pancreatic solid/cystic mass, lymphadenopathy, and gastrointestinal and subepithelial lesions. The IOR of EUS diagnosis differs depending on the disease; moreover, EUS findings with high IOR and those with IOR that was not necessarily high were used as diagnostic criteria. Therefore, to further increase the value of EUS diagnosis, EUS diagnostic criteria with high diagnostic characteristics based on EUS findings with high IOR must be established.

20.
Diagnostics (Basel) ; 10(12)2020 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-33255736

RESUMO

Esophageal varices are caused by the development of collateral circulation in the esophagus as a result of portal hypertension. It is important to administer appropriate preventive treatment because bleeding varices can be fatal. Esophageal varices have complex and diverse hemodynamics, and there are various variations for each case. Endoscopic ultrasound (EUS) can estimate the hemodynamics of each case. Therefore, observation by EUS in esophageal varices provides useful information, such as safe and effective treatment selection, prediction of recurrence, and appropriate follow-up after treatment. Although treatment for the esophagogastric varices can be performed without EUS imaging, understanding the local hemodynamics of the varices using EUS prior to treatment will lead to more safe and effective treatment. EUS observation is an indispensable tool for thorough variceal care.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA