Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Stroke ; 55(3): e77-e90, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38284265

RESUMO

Cerebral venous thrombosis accounts for 0.5% to 3% of all strokes. The most vulnerable populations include young individuals, women of reproductive age, and patients with a prothrombotic state. The clinical presentation of cerebral venous thrombosis is diverse (eg, headaches, seizures), requiring a high level of clinical suspicion. Its diagnosis is based primarily on magnetic resonance imaging/magnetic resonance venography or computed tomography/computed tomographic venography. The clinical course of cerebral venous thrombosis may be difficult to predict. Death or dependence occurs in 10% to 15% of patients despite intensive medical treatment. This scientific statement provides an update of the 2011 American Heart Association scientific statement for the diagnosis and management of cerebral venous thrombosis. Our focus is on advances in the diagnosis and management decisions of patients with suspected cerebral venous thrombosis. We discuss evidence for the use of anticoagulation and endovascular therapies and considerations for craniectomy. We also provide an algorithm to optimize the management of patients with cerebral venous thrombosis and those with progressive neurological deterioration or thrombus propagation despite maximal medical therapy.


Assuntos
Trombose Intracraniana , Trombose dos Seios Intracranianos , Trombose Venosa , Humanos , Feminino , American Heart Association , Trombose Intracraniana/diagnóstico por imagem , Trombose Intracraniana/terapia , Angiografia por Ressonância Magnética , Cavidades Cranianas , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/terapia , Trombose dos Seios Intracranianos/tratamento farmacológico
2.
Eur J Vasc Endovasc Surg ; 63(4): 546-555, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35241374

RESUMO

OBJECTIVE: A systematic review and meta-analysis of the peri-operative outcomes of carotid endarterectomy (CEA) on dual antiplatelet therapy (DAPT) vs. aspirin monotherapy was carried out, to determine optimal peri-operative management with these antiplatelet agents. DATA SOURCES: The Web of Science, Pubmed, and Embase databases were searched from inception to July 2021. The corresponding authors of excluded articles were contacted to obtain additional data for possible inclusion. REVIEW METHODS: The main outcomes included ischaemic complications (stroke, transient ischaemic attack [TIA], and transcranial Doppler [TCD] measured micro-emboli), haemorrhagic complications (haemorrhagic stroke, neck haematoma, and re-operation for bleeding), and composite outcomes. Pooled estimates using odds ratios (ORs) were combined using a random or fixed effects model based on the results of the chi square test and calculation of I2. RESULTS: In total, 47 411 patients were included in 11 studies, with 14 345 (30.2%) receiving DAPT and 33 066 (69.7%) receiving aspirin only. There was no significant difference in the rates of peri-operative stroke (OR 0.87, 95% confidence interval [CI] 0.72 - 1.05) and TIA (OR 0.78, 95% CI 0.52 - 1.17) despite a significant reduction in TCD measured micro-emboli (OR 0.19, 95% CI 0.10 - 0.35) in the DAPT compared with the aspirin monotherapy group. Subgroup analysis did not reveal any significant difference in ischaemic stroke risk between patients with asymptomatic and symptomatic carotid artery stenosis. DAPT was associated with an increased risk of neck haematoma (OR 2.79, 95% CI 1.87 - 4.18) and re-operation for bleeding (OR 1.98, 95% CI 1.77 - 2.23) vs. aspirin. Haemorrhagic stroke was an under reported outcome in the literature. CONCLUSION: This meta-analysis found that CEA while on DAPT increased the risk of haemorrhagic complications, with similar rates of ischaemic complications, vs. aspirin monotherapy. This suggests that the risks of performing CEA on DAPT outweigh the benefits, even in patients with symptomatic carotid stenosis. The overall quality of studies was low, and improved reporting of CEA outcomes in the literature is necessary.


Assuntos
Isquemia Encefálica , Estenose das Carótidas , Endarterectomia das Carótidas , Acidente Vascular Cerebral Hemorrágico , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Aspirina/efeitos adversos , Isquemia Encefálica/etiologia , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Hematoma/etiologia , Hemorragia/induzido quimicamente , Humanos , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Inibidores da Agregação Plaquetária/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
3.
J Stroke Cerebrovasc Dis ; 31(6): 106456, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35390729

RESUMO

OBJECTIVES: Ischemic stroke has been estimated to occur in up to 26% of patients with blunt cerebrovascular injury (BCVI). Antithrombotic therapy (AT) may be used for stroke prevention, but the role of endovascular treatment (ET) remains unclear. We systematically reviewed the literature on AT and ET for the treatment of patients with BCVIs. MATERIALS AND METHODS: PubMed, EMBASE, Web of Science, and Cochrane were searched upon the PRISMA guidelines to include studies reporting the use of ET in BCVI patients. Post-ET neurologic outcomes, radiographic responses, and complication rates were assessed. A fixed-effect model meta-analysis was performed to compare treatment-related post-BCVI ischemic stroke rates between AT and ET protocols. RESULTS: We included 16 studies comprising 352 patients undergoing ET for BCVI. Mean post-ET rates of good neurologic outcomes and radiologic responses were 86.9% (range, 63.6-100%) and 94.0% (range 57.1-100%), respectively. Mean post-ET complication rate was 5.2% (range, 0-66.7%). Seven studies compared the roles of AT (delivered in 805 patients) and ET (performed in 235 patients) for preventing the onset of post-BCVI ischemic strokes. No significant difference in rates of post-BCVI ischemic stroke was found between patients receiving AT vs patients undergoing ET (OR 0.71, 95% CI: 0.35-1.42, p = 0.402). CONCLUSION: AT and ET may be comparable in preventing the occurrence of ischemic stroke following BCVIs. AT may be preferred as the less-invasive first-line therapy, but ET showed favorable rates of post-treatment clinical and radiologic outcomes, coupled with low rates of treatment-related complications.


Assuntos
Traumatismo Cerebrovascular , AVC Isquêmico , Acidente Vascular Cerebral , Ferimentos não Penetrantes , Traumatismo Cerebrovascular/complicações , Fibrinolíticos/efeitos adversos , Humanos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/prevenção & controle , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/terapia
4.
Neurosurg Focus ; 51(1): E3, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34198250

RESUMO

OBJECTIVE: Mechanical endovascular thrombectomy (EVT) is an increasingly relied-on treatment for clot retrieval in the context of ischemic strokes, which otherwise are associated with significant morbidity and mortality. Despite several known risks associated with this procedure, there is a high degree of technical heterogeneity across both centers and operators. The most common procedural complications occur at the point of transfemoral access (the common femoral artery), and include access-site hematomas, dissections, and pseudoaneurysms. Other interventional fields have previously popularized the use of ultrasound to enhance the anatomical localization of structures relevant to vascular access and thereby reducing access-site complications. In this study, the authors aimed to describe the ultrasound-guided EVT technique performed at a large, quaternary neurovascular referral center, and to characterize the effects of ultrasound guidance on access-site complications. METHODS: A retrospective chart review of all patients treated with EVT at a single center between January 2013 and August 2020 was performed. Patients in this cohort were treated using a universal, unique, ultrasound-guided, single-wall puncture technique, which bears several theoretical advantages over the standard technique of arterial puncture via palpation. RESULTS: There were 479 patients treated with EVT within the study period. Twenty patients in the cohort were identified as having experienced some form of access-site complication. Eight (1.67%) of these patients experienced minor access-site complications, all of which were groin hematomas and none of which were clinically significant, as defined by requiring surgical or interventional management or transfusion. The remaining 12 patients experienced arterial dissection (n = 5), arterial pseudoaneurysm (n = 4), retroperitoneal hematoma (n = 2), or arterial occlusion (n = 1), with only 1.04% (5/479) requiring surgical or interventional management or transfusion. CONCLUSIONS: The authors found an overall reduction in total access-site complications as well as minor access-site complications in the study cohort compared with previously published randomized controlled trials and observational studies in the recent literature. The findings suggested that there may be a role for routine use of ultrasound-guided puncture techniques in EVT to decrease rates of complications.


Assuntos
Procedimentos Endovasculares , Trombectomia , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Estudos Retrospectivos , Ultrassonografia de Intervenção
5.
Can J Neurol Sci ; 47(4): 479-485, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32138792

RESUMO

BACKGROUND AND PURPOSE: Large prospective observational studies have cast doubt on the common assumption that endovascular thrombectomy (EVT) is superior to intravenous thrombolysis for patients with acute basilar artery occlusion (BAO). The purpose of this study was to retrospectively review our experience for patients with BAO undergoing EVT with modern endovascular devices. METHODS: All consecutive patients undergoing EVT with either a second-generation stent retriever or direct aspiration thrombectomy for BAO at our regional stroke center from January 1, 2013 to March 1, 2019 were included. The primary outcome measure was functional outcome at 1 month using the modified Rankin Scale (mRS) score. Multivariable logistic regression was used to assess the association between patient characteristics and dichotomized mRS. RESULTS: A total of 43 consecutive patients underwent EVT for BAO. The average age was 67 years with 61% male patients. Overall, 37% (16/43) of patients achieved good functional outcome. Successful reperfusion was achieved in 72% (31/43) of cases. The median (interquartile range) stroke onset to treatment time was 420 (270-639) minutes (7 hours) for all patients. The procedure-related complication rate was 9% (4/43). On multivariate analysis, posterior circulation Alberta stroke program early computed tomography score and Basilar Artery on Computed Tomography Angiography score were associated with improved functional outcome. CONCLUSION: EVT appears to be safe and feasible in patients with BAO. Our finding that time to treatment and successful reperfusion were not associated with improved outcome is likely due to including patients with established infarcts. Given the variability of collaterals in the posterior circulation, the paradigm of utilizing a tissue window may assist in patient selection for EVT. Magnetic resonance imaging may be a reasonable option to determine the extent of ischemia in certain situations.


Assuntos
Artéria Basilar/diagnóstico por imagem , Artéria Basilar/cirurgia , Procedimentos Endovasculares/tendências , Trombectomia/tendências , Insuficiência Vertebrobasilar/diagnóstico por imagem , Insuficiência Vertebrobasilar/cirurgia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Trombectomia/métodos , Resultado do Tratamento
6.
Can J Neurol Sci ; 46(1): 87-95, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30688207

RESUMO

BACKGROUND: Computer-assisted navigation (CAN) improves the accuracy of spinal instrumentation in vertebral fractures and degenerative spine disease; however, it is not widely adopted because of lack of training, high capital costs, workflow hindrances, and accuracy concerns. We characterize shifts in the use of spinal CAN over time and across disciplines in a single-payer health system, and assess the impact of intra-operative CAN on trainee proficiency across Canada. METHODS: A prospectively maintained Ontario database of patients undergoing spinal instrumentation from 2005 to 2014 was reviewed retrospectively. Data were collected on treated pathology, spine region, surgical approach, institution type, and surgeon specialty. Trainee proficiency with CAN was assessed using an electronic questionnaire distributed across 15 Canadian orthopedic surgical and neurosurgical programs. RESULTS: In our provincial cohort, 16.8% of instrumented fusions were CAN-guided. Navigation was used more frequently in academic institutions (15.9% vs. 12.3%, p<0.001) and by neurosurgeons than orthopedic surgeons (21.0% vs. 12.4%, p<0.001). Of residents and fellows 34.1% were fully comfortable using spinal CAN, greater for neurosurgical than orthopedic surgical trainees (48.1% vs. 11.8%, p=0.008). The use of CAN increased self-reported proficiency in thoracic instrumentation for all trainees by 11.0% (p=0.036), and in atlantoaxial instrumentation for orthopedic trainees by 18.0% (p=0.014). CONCLUSIONS: Spinal CAN is used most frequently by neurosurgeons and in academic centers. Most spine surgical trainees are not fully comfortable with the use of CAN, but report an increase in technical comfort with CAN guidance particularly for thoracic instrumentation. Increased education in spinal CAN for trainees, particularly at the fellowship stage and, specifically, for orthopedic surgery, may improve adoption.


CONTEXTE: La chirurgie assistée par ordinateur (CAO) permet d'améliorer la précision de l'exploration instrumentale employée dans le cas de fractures vertébrales et de maladies dégénératives de la colonne vertébrale. Cela dit, elle n'a pas encore été adoptée à grande échelle en raison d'un manque de formation, de coûts d'immobilisation considérables, d'obstacles liés à l'organisation du travail et de doutes quant à son exactitude. C'est dans cette perspective que nous voulons décrire, parmi divers champs de pratique, les transformations se rapportant au fil du temps à l'utilisation de la CAO de la colonne vertébral dans le cadre d'un régime de santé universel à payeur unique. Qui plus est, nous voulons aussi évaluer l'impact de la CAO en ce qui a trait aux compétences des stagiaires partout au Canada. MÉTHODES: Pour ce faire, nous avons passé en revue de façon rétrospective une base de données tenue à jour prospectivement au sujet de patients ontariens ayant été soumis de 2005 à 2014 à une exploration instrumentale de la colonne vertébrale. Les données obtenues portaient sur le type de pathologie traitée, sur la région de la colonne vertébrale visée, sur l'approche chirurgicale privilégiée, sur le type d'établissement et sur la spécialité du chirurgien ayant intervenu. Les compétences des stagiaires en matière de CAO ont également été évaluées à l'aide d'un questionnaire en ligne diffusé au sein de 15 programmes canadiens de chirurgie orthopédique et de neurochirurgie. RÉSULTATS: En tout, 16,8 % des fusions instrumentées réalisées au sein de notre cohorte ontarienne l'ont été à l'aide de la technique de la CAO. Cette dernière a été utilisée plus fréquemment dans des établissements d'enseignement universitaire (15,9 % par opposition à 12,3 % pour les autres; p<0,001) mais aussi plus souvent par des neurochirurgiens (21,0 % par opposition à 12,4 % par des chirurgiens orthopédiques; p<0,001). En outre, 34,1 % des résidents et des médecins suivant une formation complémentaire étaient parfaitement à l'aise dans l'utilisation de la CAO de la colonne vertébrale (48,1 % de ceux se spécialisant en neurochirurgie par opposition à 11,8 % de ceux se spécialisant en chirurgie orthopédique; p = 0,008). L'utilisation de la CAO a par ailleurs entraîné une augmentation, auto-déclarée, de 11,0 % de l'aptitude à faire usage de l'exploration instrumentale thoracique chez tous les stagiaires (p = 0,036); dans le cas de l'exploration instrumentale atlanto-axiale, cette augmentation a été de 18,0 % (p = 0,014) chez les stagiaires en chirurgie orthopédique. CONCLUSIONS: La CAO de la colonne vertébrale est employée le plus souvent par les neurochirurgiens dans des établissements d'enseignement universitaire. La plupart des stagiaires en chirurgie de la colonne vertébrale ne sont pas entièrement à l'aise en ce qui concerne l'utilisation de la CAO. Toutefois, ils ont signalé une augmentation de leur aisance à utiliser la CAO et à bénéficier de son assistance, en particulier dans des cas d'exploration instrumentale thoracique. En somme, une plus ample formation en matière de CAO de la colonne vertébrale offerte aux stagiaires, particulièrement à ceux suivant une formation complémentaire et dans le champ de la chirurgie orthopédique, pourrait favoriser son adoption.


Assuntos
Internato e Residência , Neurocirurgiões , Procedimentos Neurocirúrgicos/métodos , Ortopedia/métodos , Doenças da Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Canadá , Planejamento em Saúde Comunitária , Bases de Dados Factuais/estatística & dados numéricos , Feminino , Humanos , Masculino , Sistemas On-Line , Estudos Retrospectivos
7.
Appl Opt ; 58(13): 3401-3409, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31044835

RESUMO

We present a differential phase standard-deviation (DPSD)-based optical coherence tomographic (OCT) angiography (OCTA) technique to calculate the angiography images of the human retina. The standard deviation was calculated along the depth direction on the differential phase image of two B-scans (from the same position, at different times) to contrast dynamic vascular signals. The performance of a DPSD was verified by both phantom and in vivo experiments. When compared to other OCTA algorithms such as phase variance OCT, speckle variance OCT, and optical microangiography, we showed that a DPSD achieved improved image contrast and higher sensitivity. Furthermore, we also found the improved signal-to-noise ratio and contrast-to-noise ratio of 1.6 dB and 0.5, respectively, in large scanning range images.


Assuntos
Angiofluoresceinografia/métodos , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Algoritmos , Humanos , Disco Óptico/irrigação sanguínea , Imagens de Fantasmas , Vasos Retinianos/diagnóstico por imagem , Razão Sinal-Ruído
8.
Br J Neurosurg ; 33(1): 92-93, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28436277

RESUMO

Acute concomitant occlusions of the extracranial internal carotid artery and intracranial vessels frequently require multiple passes with stent-retrievers for mechanical thrombectomy. Due to the large clot burden associated with these occlusions, their response to intravenous thrombolysis is poor. We herein report a successful case of evacuating a massive clot (>14 cm) in a single-pass using a stent-retrieval device.


Assuntos
Arteriopatias Oclusivas/terapia , Artéria Carótida Interna , Estenose das Carótidas/terapia , Doenças Arteriais Cerebrais/terapia , Trombólise Mecânica/métodos , Estenose das Carótidas/cirurgia , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Acidente Vascular Cerebral/terapia , Resultado do Tratamento
9.
Opt Express ; 25(7): 7761-7777, 2017 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-28380895

RESUMO

In this paper, a multi-beam scanning technique is proposed to optimize the microvascular images of human skin obtained with Doppler effect based methods and speckle variance processing. Flow phantom experiments were performed to investigate the suitability for combining multi-beam data to achieve enhanced microvascular imaging. To our surprise, the highly variable spot sizes (ranging from 13 to 77 µm) encountered in high numerical aperture multi-beam OCT system imaging the same target provided reasonably uniform Doppler variance and speckle variance responses as functions of flow velocity, which formed the basis for combining them to obtain better microvascular imaging without scanning penalty. In vivo 2D and 3D imaging of human skin was then performed to further demonstrate the benefit of combining multi-beam scanning to obtain improved signal-to-noise ratio (SNR) in microvascular imaging. Such SNR improvement can be as high as 10 dB. To our knowledge, this is the first demonstration of combining different spot size, staggered multiple optical foci scanning, to achieve enhanced SNR for blood flow OCT imaging.


Assuntos
Aumento da Imagem/métodos , Microvasos/diagnóstico por imagem , Unhas/diagnóstico por imagem , Pele/irrigação sanguínea , Tomografia de Coerência Óptica/métodos , Algoritmos , Humanos , Unhas/irrigação sanguínea , Imagens de Fantasmas , Razão Sinal-Ruído , Pele/diagnóstico por imagem , Tomografia de Coerência Óptica/instrumentação
10.
Can J Neurol Sci ; 44(3): 235-245, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28434425

RESUMO

Augmented reality (AR) superimposes computer-generated virtual objects onto the user's view of the real world. Among medical disciplines, neurosurgery has long been at the forefront of image-guided surgery, and it continues to push the frontiers of AR technology in the operating room. In this systematic review, we explore the history of AR in neurosurgery and examine the literature on current neurosurgical applications of AR. Significant challenges to surgical AR exist, including compounded sources of registration error, impaired depth perception, visual and tactile temporal asynchrony, and operator inattentional blindness. Nevertheless, the ability to accurately display multiple three-dimensional datasets congruently over the area where they are most useful, coupled with future advances in imaging, registration, display technology, and robotic actuation, portend a promising role for AR in the neurosurgical operating room.


Assuntos
Processamento de Imagem Assistida por Computador/tendências , Procedimentos Neurocirúrgicos/tendências , Cirurgia Assistida por Computador/tendências , Interface Usuário-Computador , Realidade Virtual , Encefalopatias/diagnóstico por imagem , Encefalopatias/cirurgia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Procedimentos Neurocirúrgicos/métodos , Doenças da Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos
12.
Opt Express ; 24(15): 16674-86, 2016 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-27464121

RESUMO

A surgical laser soft tissue ablation system based on an adjustable 1942 nm single-mode all-fiber Tm-doped fiber laser operating in pulsed or CW mode with nitrogen assistance is demonstrated. Ex vivo ablation on soft tissue targets such as muscle (chicken breast) and spinal cord (porcine) with intact dura are performed at different ablation conditions to examine the relationship between the system parameters and ablation outcomes. The maximum laser average power is 14.4 W, and its maximum peak power is 133.1 W with 21.3 µJ pulse energy. The maximum CW power density is 2.33 × 106 W/cm2 and the maximum pulsed peak power density is 2.16 × 107 W/cm2. The system parameters examined include the average laser power in CW or pulsed operation mode, gain-switching frequency, total ablation exposure time, and the input gas flow rate. The ablation effects were measured by microscopy and optical coherence tomography (OCT) to evaluate the ablation depth, superficial heat-affected zone diameter (HAZD) and charring diameter (CD). Our results conclude that the system parameters can be tailored to meet different clinical requirements such as ablation for soft tissue cutting or thermal coagulation for future applications of hemostasis.


Assuntos
Hemostasia , Terapia a Laser/instrumentação , Animais , Terapia a Laser/métodos , Lasers , Fenômenos Físicos , Suínos
13.
Br J Neurosurg ; 30(2): 269-71, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26168301

RESUMO

BACKGROUND: Bone flap re-approximation during cranioplasty can be complicated by underlying pseudomeningocele or meningoencephalocele. A technique for controlled reduction duraplasty to aid bone flap positioning is suggested. METHODS: A simple method using bipolar electrocautery in a predetermined radial pattern from the center of defect is described. Localized tissue contraction allows controlled reduction in the surface area and degree of protrusion. This in turn facilitates bone flap positioning. RESULTS: The main advantage of this technique is slow and evenly distributed pressure conferred by controlled tissue contraction using multiple radial coagulation lines. No technical difficulties or complications have occurred with this method during cranioplasty for 11 patients. CONCLUSION: This simple technique for controlled reduction duraplasty can provide an easy and efficient method for bone flap re-approximation, and add to the existing techniques for a commonly performed procedure.


Assuntos
Craniotomia , Encefalocele/cirurgia , Procedimentos de Cirurgia Plástica , Crânio/cirurgia , Retalhos Cirúrgicos , Craniotomia/métodos , Feminino , Humanos , Masculino , Procedimentos de Cirurgia Plástica/métodos
16.
Opt Express ; 22(7): 7399-415, 2014 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-24718115

RESUMO

We report a technique for blood flow detection using split spectrum Doppler optical coherence tomography (ssDOCT) that shows improved sensitivity over existing Doppler OCT methods. In ssDOCT, the Doppler signal is averaged over multiple sub-bands of the interferogram, increasing the SNR of the Doppler signal. We explore the parameterization of this technique in terms of number of sub-band windows, width and overlap of the windows, and their effect on the Doppler signal to noise in a flow phantom. Compared to conventional DOCT, ssDOCT processing has increased flow sensitivity. We demonstrate the effectiveness of ssDOCT in-vivo for intravascular flow detection within a porcine carotid artery and for microvascular vessel detection in human pulmonary imaging, using rotary catheter probes. To our knowledge, this is the first report of visualizing in-vivo Doppler flow patterns adjacent to stent struts in the carotid artery.


Assuntos
Algoritmos , Velocidade do Fluxo Sanguíneo/fisiologia , Catéteres , Fluxometria por Laser-Doppler/instrumentação , Imagens de Fantasmas , Tomografia de Coerência Óptica/instrumentação , Animais , Humanos , Suínos
17.
Opt Lett ; 39(12): 3638-41, 2014 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-24978556

RESUMO

We report a polarization diversity detection scheme for optical coherence tomography with a new, custom, miniaturized fiber coupler with single mode (SM) fiber inputs and polarization maintaining (PM) fiber outputs. The SM fiber inputs obviate matching the optical lengths of the X and Y OCT polarization channels prior to interference and the PM fiber outputs ensure defined X and Y axes after interference. Advantages for this scheme include easier alignment, lower cost, and easier miniaturization compared to designs with free-space bulk optical components. We demonstrate the utility of the detection system to mitigate the effects of rapidly changing polarization states when imaging with rotating fiber optic probes in Intralipid suspension and during in vivo imaging of human airways.


Assuntos
Tomografia de Coerência Óptica/métodos , Emulsões , Endoscopia/instrumentação , Endoscopia/métodos , Desenho de Equipamento , Tecnologia de Fibra Óptica , Humanos , Miniaturização , Fibras Ópticas , Fenômenos Ópticos , Fosfolipídeos , Sistema Respiratório/anatomia & histologia , Óleo de Soja , Tomografia de Coerência Óptica/instrumentação
18.
Opt Express ; 21(20): 24076-86, 2013 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-24104316

RESUMO

Temperature-compensated 3D fiber shape sensing is demonstrated with femtosecond laser direct-written optical and Bragg grating waveguides that were distributed axially and radially inside a single coreless optical fiber. Efficient light coupling between the laser-written optical circuit elements and a standard single-mode fiber (SMF) was obtained for the first time by 3D laser writing of a 1 × 3 directional coupler to meet with the core waveguide in the fusion-spliced SMF. Simultaneous interrogation of nine Bragg gratings, distributed along three laterally offset waveguides, is presented through a single waveguide port at 1 kHz sampling rate to follow the Bragg wavelength shifts in real-time and thereby infer shape and temperature profile unambiguously along the fiber length. This distributed 3D strain and thermal sensor is freestanding, flexible, compact, lightweight and opens new directions for creating fiber cladding photonic devices for a wide range of applications from shape and thermal sensing to guidance of biomedical catheters and tools in minimally invasive surgery.

19.
Catheter Cardiovasc Interv ; 81(3): 494-507, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22566368

RESUMO

OBJECTIVE: To demonstrate the feasibility of imaging human coronary atherosclerosis using a novel hybrid intravascular ultrasound (IVUS) and optical coherence tomography (OCT) imaging catheter. BACKGROUND: IVUS and OCT have synergistic advantages and recent studies involving both modalities suggest the use of a hybrid imaging catheter may offer improved guidance of coronary interventions and plaque characterization. METHODS: A 1.3 m custom hybrid IVUS-OCT imaging probe was built within a 4F catheter using a 42 MHz ultrasound transducer and an OCT imaging fiber. Coplanar images were simultaneously acquired ex vivo by both modalities in 31 arterial segments from 11 cadaveric human coronaries. IVUS and OCT images were acquired at 250 µm intervals, of which 13 of the arterial segments were selected as representative of a diverse set of pathological findings. The selected segments were then imaged with either digital X-ray or micro-CT, processed for histological analysis and compared with the corresponding IVUS and OCT images. RESULTS: Images of human coronary atherosclerosis using the hybrid IVUS-OCT catheter demonstrated a range of vascular pathologies that were confirmed on histology. The anticipated synergistic advantages of each modality were qualitatively apparent, including the deeper tissue penetration of IVUS and the superior contrast, resolution and near-field image quality of OCT. CONCLUSIONS: Preliminary ex vivo images using a hybrid IVUS-OCT catheter demonstrated feasibility in using the device for intracoronary imaging of atherosclerosis. Future studies will include in vivo imaging and larger samples sizes to enable quantitative comparisons of tissue characterization and feature identification using hybrid imaging catheters versus standalone IVUS and OCT imaging techniques. © 2012 Wiley Periodicals, Inc.


Assuntos
Catéteres , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Placa Aterosclerótica/diagnóstico , Tomografia de Coerência Óptica/instrumentação , Ultrassonografia de Intervenção/instrumentação , Cadáver , Desenho de Equipamento , Humanos
20.
J Orthop Surg Res ; 18(1): 706, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37730623

RESUMO

Robotics in medicine is associated with precision, accuracy, and replicability. Several robotic systems are used in spine surgery. They are all considered shared-control systems, providing "steady-hand" manipulation instruments. Although numerous studies have testified to the benefits of robotic instrumentations, they must address their true accuracy. Our study used the Mazor system under several situations and compared the spatial accuracy of the pedicle screw (PS) insertion and its planned trajectory. We used two cadaveric specimens with intact spinal structures from C7 to S1. PS planning was performed using the two registration methods (preopCT/C-arm or CT-to-fluoroscopy registration). After planning, the implant spatial orientation was defined based on six anatomic parameters using axial and sagittal CT images. Two surgical open and percutaneous access were used to insert the PS. After that, another CT acquisition was taken. Accuracy was classified into optimal, inaccurate and unacceptable according to the degree of screw deviation from its planning using the same spatial orientation method. Based on the type of spatial deviation, we also classified the PS trajectory into 16 pattern errors. Seven (19%) out of 37 implanted screws were considered unacceptable (deviation distances > 2.0 mm or angulation > 5°), and 14 (38%) were inaccurate (> 0.5 mm and ≤ 2.0 mm or > 2.5° and ≤ 5°). CT-to-fluoroscopy registration was superior to preopCT/C-arm (average deviation in 0.9 mm vs. 1.7 mm, respectively, p < 0.003), and percutaneous was slightly better than open but did not reach significance (1.3 mm vs. 1.7 mm, respectively). Regarding pattern error, the tendency was to have more axial than sagittal shifts. Using a quantitative method to categorize the screw 3D position, only 10.8% of the screws were considered unacceptable. However, with a more rigorous concept of inaccuracy, almost half were non-optimal. We also identified that, unlike some previous results, the O-arm registration delivers more accurate implants than the preopCT/C-arm method.


Assuntos
Parafusos Pediculares , Cirurgia Assistida por Computador , Humanos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X , Fluoroscopia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA