Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Heart Lung Circ ; 31(4): 559-565, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34916154

RESUMO

BACKGROUND: Indications for transcatheter aortic valve implantation (TAVI) in aortic stenosis are expanding and the life expectancy of patients following TAVI is increasing. Determining the long-term durability of TAVI valves is therefore important. Rates of long-term (≥5 years) structural valve deterioration (SVD) vary widely and there are currently no comparable data from Australia. The aim herein was to determine the incidence of haemodynamic SVD and bioprosthetic valve failure (BVF) using recently standardised definitions in a Western Australian cohort after at least 5 years. METHODS: This is a retrospective cohort study of consecutive patients undergoing TAVI at Royal Perth Hospital between January 2009 and January 2015. Of 211 patients, 55 survived ≥5 years and had echocardiographic data available for review. Median time to the echocardiogram was 5.9 years (max 7.8 years); 49% male, mean age 83 years. RESULTS: Of the 55 survivors who had echocardiograms available ≥5 years after TAVI, four (9%) had moderate haemodynamic SVD and one (2%) had severe SVD and BVF. CONCLUSIONS: Our results suggest excellent long-term durability of contemporary TAVI valves in an Australian cohort with very low incidence of SVD and BVF. These findings add confidence to the expanding applications of TAVI valves.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Austrália/epidemiologia , Bioprótese/efeitos adversos , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Falha de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Lancet ; 396(10252): 669-683, 2020 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-32593323

RESUMO

BACKGROUND: Randomised trial data assessing the safety and efficacy of the self-expanding intra-annular Portico transcatheter aortic valve system (Abbott Structural Heart, St Paul, MN, USA) compared with any commercially available valves are needed to compare performance among designs. METHODS: In this prospective, multicentre, non-inferiority, randomised controlled trial (the Portico Re-sheathable Transcatheter Aortic Valve System US Investigational Device Exemption trial [PORTICO IDE]), high and extreme risk patients with severe symptomatic aortic stenosis were recruited from 52 medical centres experienced in performing transcatheter aortic valve replacement in the USA and Australia. Patients were eligible if they were aged 21 years or older, in New York Heart Association functional class II or higher, and had severe native aortic stenosis. Eligible patients were randomly assigned (1:1) using permuted block randomisation (block sizes of 2 and 4) and stratified by clinical investigational site, surgical risk cohort, and vascular access method, to transcatheter aortic valve replacement with the first generation Portico valve and delivery system or a commercially available valve (either an intra-annular balloon-expandable Edwards-SAPIEN, SAPIEN XT, or SAPIEN 3 valve [Edwards LifeSciences, Irvine, CA, USA]; or a supra-annular self-expanding CoreValve, Evolut-R, or Evolut-PRO valve [Medtronic, Minneapolis, MN, USA]). Investigational site staff, implanting physician, and study participant were unmasked to treatment assignment. Core laboratories and clinical event assessors were masked to treatment allocation. The primary safety endpoint was a composite of all-cause mortality, disabling stroke, life-threatening bleeding requiring transfusion, acute kidney injury requiring dialysis, or major vascular complication at 30 days. The primary efficacy endpoint was all-cause mortality or disabling stroke at 1 year. Clinical outcomes and valve performance were assessed up to 2 years after the procedure. Primary analyses were by intention to treat and the Kaplan-Meier method to estimate event rates. The non-inferiority margin was 8·5% for primary safety and 8·0% for primary efficacy endpoints. This study is registered with ClinicalTrials.gov, NCT02000115, and is ongoing. FINDINGS: Between May 30 and Sept 12, 2014, and between Aug 21, 2015, and Oct 10, 2017, with recruitment paused for 11 months by the funder, we recruited 1034 patients, of whom 750 were eligible and randomly assigned to the Portico valve group (n=381) or commercially available valve group (n=369). Mean age was 83 years (SD 7) and 395 (52·7%) patients were female. For the primary safety endpoint at 30 days, the event rate was higher in the Portico valve group than in the commercial valve group (52 [13·8%] vs 35 [9·6%]; absolute difference 4·2, 95% CI -0·4 to 8·8 [upper confidence bound {UCB} 8·1%]; pnon-inferiority=0·034, psuperiority=0·071). At 1 year, the rates of the primary efficacy endpoint were similar between the groups (55 [14·8%] in the Portico group vs 48 [13·4%] in the commercial valve group; difference 1·5%, 95% CI -3·6 to 6·5 [UCB 5·7%]; pnon-inferiority=0·0058, psuperiority=0·50). At 2 years, rates of death (80 [22·3%] vs 70 [20·2%]; p=0·40) or disabling stroke (10 [3·1%] vs 16 [5·0%]; p=0·23) were similar between groups. INTERPRETATION: The Portico valve was associated with similar rates of death or disabling stroke at 2 years compared with commercial valves, but was associated with higher rates of the primary composite safety endpoint including death at 30 days. The first-generation Portico valve and delivery system did not offer advantages over other commercially available valves. FUNDING: Abbott.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Mortalidade , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Austrália , Transfusão de Sangue , Causas de Morte , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/terapia , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/terapia , Diálise Renal , Índice de Gravidade de Doença , Resultado do Tratamento , Estados Unidos
3.
Heart Lung Circ ; 29(12): 1839-1846, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32712017

RESUMO

BACKGROUND: To determine the safety and performance of the SAPIEN XT transcatheter heart valve (THV) in Australian patients with severe aortic stenosis (AS) and intermediate surgical risk. METHODS: Eligible patients in this multi-centre, prospective, consecutively enrolled, non-randomised, clinical trial, received transcatheter aortic valve replacement via femoral artery access. Follow-up visits were at discharge, 30 days, and 6, 12, and 24 months. The primary endpoint was Valve Academic Research Consortium-2 composite safety at 30 days: all-cause mortality, all stroke, life-threatening bleeding, acute kidney injury-Stage 3, coronary artery obstruction requiring intervention, major vascular complication, and valve-related dysfunction requiring repeat procedure. Other endpoints were device success (successful vascular access, delivery, and deployment; correct position; intended performance mean aortic valve gradient <20 mmHg, mild or less paravalvular aortic regurgitation [PAR]; and only one valve implanted) and New York Heart Association functional class (NYHA). Kaplan-Meier (KM) estimates were calculated for the primary endpoint. RESULTS: At baseline, mean patient (N=199) age was 85.5 years, mean Society of Thoracic Surgeon score was 5.9, and 78.4% were in NYHA class III/IV. The primary composite endpoint KM estimate was 12.1%. Device success was 88.8%. SAPIEN XT was implanted in the proper location in 98.5% (n=2: valve-in-valve procedures, n=1: no implant due to left main coronary artery occlusion). No device malfunctions were reported. The post procedure PAR was mild or less in 93.8% of patients. Mean aortic gradient decreased from baseline (50.0 mmHg) to 2 years (10.3 mmHg). Most patients (90.9%) were in NYHA class I/II at 30 days. New permanent pacemaker rate was 8.1%. Stroke at 30 days was 3.5% (1.5% disabling). CONCLUSION: SAPIEN XT was safe and improved heart failure symptoms and valve haemodynamics in this cohort of Australian patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Austrália , Ecocardiografia , Feminino , Artéria Femoral , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
5.
Heart Lung Circ ; 24(4): e51-5, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25529837

RESUMO

The limited durability of prosthetic cardiac valves together with an aging population will present ongoing management challenges. This paper describes the case of an 82 year-old male with symptomatic severe regurgitation in an aortic homograft which remains successfully treated with Transcatheter Aortic Valve Replacement (TAVR) at two-year follow-up.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/transplante , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Qualidade de Vida , Idoso de 80 Anos ou mais , Aloenxertos , Insuficiência da Valva Aórtica/etiologia , Humanos , Masculino
6.
Heart Lung Circ ; 24(3): 281-90, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25456213

RESUMO

BACKGROUND: Although numerous studies have reported the safety and effectiveness of transcatheter aortic valve implantation (TAVI), integration of this therapy into standard of care varies widely by region. We evaluated mid-term follow-up in 540 patients with severe symptomatic AS at high risk of surgical AV replacement, enrolled in the ongoing Medtronic CoreValve Australia-New Zealand Study. METHODS: Between August 2008 and July 2013, 10 centres in Australia/New Zealand enrolled 540 patients, which includes initial use of the CoreValve System for all investigators. Patients were deemed suitable for TAVI based on consensus of a multidisciplinary Heart Team. Primary endpoints were cardiovascular death and major adverse cardiovascular and cerebrovascular events (MACCE) at 30 days. Data were fully monitored, and an independent Clinical Events Committee employed. RESULTS: Baseline characteristics include; 45% female, mean age 84 years, EuroSCORE 17.3±10.7%, and 74.9% had New York Heart Association III/IV symptoms. At 30 days, all deaths were cardiovascular (4.1%); MACCE was 11.5%. At one and two years, all-cause mortality was 11.9% and 21.2%; cardiovascular mortality, 9.9% and 15.2%; and stroke, 8.2% and 10.1%, respectively. CONCLUSIONS: Early experience with the CoreValve System in a large cohort of fully-monitored patients was associated with good early- and mid-term safety outcomes.


Assuntos
Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Austrália/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Nova Zelândia , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos
7.
Eur Heart J Case Rep ; 8(6): ytae226, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38845809

RESUMO

Background: Iatrogenic aortic valve injury during cardiovascular catheterization interventions is extremely rare. Severe aortic regurgitation that ensues can be catastrophic and the management is typically with surgical valve replacement or repair. Percutaneous management of native pure aortic regurgitation is difficult due to anatomical challenges and the limitations of current transcatheter heart valve technology to anchor in the absence of leaflet or annular calcification. Case Summary: An 82-year-old female underwent rotational atherectomy (RA) for a severely calcified stenosis of the left anterior descending artery. The patient was discharged well following placement of two drug eluting stents. She represented to hospital 7 days later with acute pulmonary oedema. Bedside transthoracic echocardiography demonstrated new, severe AR with preserved left ventricular size and function. Review of the prior percutaneous coronary intervention revealed significant trauma to the aortic valve during RA, with contrast seen refluxing into the LV during diastole, evolving throughout the procedure. Given the patient was not an operative candidate, an oversized transcatheter aortic valve was successfully implanted. In the post-operative setting, the patient suffered a stroke. Extensive hypoattenuated leaflet thickening (HALT) and thrombus was seen on dedicated 4D CT imaging. She made full neurological recovery and valve function returned to normal following a period of anticoagulation. Conclusion: Although iatrogenic aortic valve laceration is rare, this case highlights several important learning points including the importance of good guide catheter support during RA; the feasibility of Transcatheter Aortic Valve Replacement for pure native AR; and the detection and management of HALT.

8.
JACC Case Rep ; 29(10): 102330, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38601844

RESUMO

This clinical case describes a subacute presentation of decompensated heart failure secondary to an iatrogenic left ventricle-to-coronary sinus fistula after sequential mitral valve surgical procedures. Computed tomography was used to select an unconventional hybrid transapical access approach and facilitate successful closure using a vascular plug.

9.
J Vasc Surg ; 58(4): 1028-36.e1, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23993436

RESUMO

OBJECTIVE: Transcatheter aortic valve implantation (TAVI) has gained increasing global popularity as a minimally invasive option for high-risk cardiac patients. However, this operation is not without risk, particularly of significant vascular complications that increase the morbidity, mortality, and overall cost of the procedure. We aim to present our experience of TAVI-related vascular complications, including the morbidity and cost impacts of these events. METHODS: A case-series study was performed for all patients undergoing TAVI at our center. Vascular complications were defined according to the 2011 Valve Academic Research Consortium standardized end points. The data were prospectively collected from February 2009 to April 2012, and the outcomes were entered into a database and cross-checked with the hospital notes. RESULTS: TAVI was performed on 100 patients in our center during the study period, and the 30-day mortality was 6%. Access approaches included 81 transfemoral, 18 transapical, and one trans-subclavian access. The average patient age was 84.9 years, and 65% of the patients were male. Among the transfemoral procedures, there were 16 vascular access-related complications (VAC), including nine major and seven minor complications. The major complications included aortic dissection, iliac arterial rupture, femoral dissection, false aneurysms, and distal embolization, all of which required surgical or endovascular repair. An apical false aneurysm and an apical tear were major VAC of the transapical group, with the latter resulting in death. Patients with VAC had higher blood transfusion requirements (4.1 ± 4.5 units vs 0.9 ± 2.2 units; P = .004), greater length of hospital stay (16.4 ± 10.7 days vs 6.5 ± 5.1 days; P = .001), and increased cost (A$93,448 ± 21,435 vs A$69,932 ± 15,007; P = .002) compared with the non-VAC group. The predictors of vascular complications using multivariate analysis included European System for Cardiac Operative Risk Evaluation (odds ratio, 1.06; 95% confidence interval, 1.02-1.10; P = .001) and diabetes mellitus (odds ratio, 5.07; 95% confidence interval, 1.17-21.88; P = .03). Occurrence of major VAC did not affect in-hospital or 30-day mortality rates and was not associated with poorer survival. CONCLUSIONS: Vascular complications affect perioperative management and outcomes following TAVI. Our findings show that these complications often require urgent surgical or endovascular repair and result in increased blood transfusions, greater length of hospital stay, and significantly increased costs. Diabetes mellitus and logistic European System for Cardiac Operative Risk Evaluation may be predictive of VAC and should be considered during TAVI patient selection.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Doenças Vasculares/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Diabetes Mellitus/epidemiologia , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Incidência , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Seleção de Pacientes , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Doenças Vasculares/mortalidade , Doenças Vasculares/terapia , Austrália Ocidental/epidemiologia
10.
EuroIntervention ; 19(3): 248-255, 2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-36895190

RESUMO

BACKGROUND: The Navitor transcatheter heart valve (THV) is a self-expanding valve, with an intra-annular leaflet position and an outer cuff intended to reduce paravalvular leak (PVL). AIMS: The aim of the PORTICO NG Study is to assess the safety and performance of the Navitor THV in patients with symptomatic, severe aortic stenosis who are at high or extreme surgical risk. METHODS: PORTICO NG is a prospective, multicentre, global, single-arm, investigational study with follow-up at 30 days, 1 year, and annually up to 5 years. The primary endpoints are all-cause mortality and moderate or greater PVL at 30 days. Valve Academic Research Consortium-2 events and valve performance are assessed by an independent clinical events committee and echocardiographic core laboratory. RESULTS: A total of 120 high- or extreme-risk subjects (age 83.5±5.4 years; 58.3% female; Society of Thoracic Surgeons score 4.0±2.0%) were enrolled in the European conformity (CE) mark cohort. Procedural success was high at 97.5%. At 30 days, the rate of all-cause mortality was 0%, and no subjects had moderate or greater PVL. The rate of disabling stroke was 0.8%, life-threatening bleeding was 2.5%, stage 3 acute kidney injury 0%, major vascular complications 0.8%, and new pacemaker implantation 15.0%. At 1 year, the rates of all-cause mortality and disabling stroke were 4.2% and 0.8%, respectively. The rate of moderate PVL was 1.0% at 1 year. Haemodynamic performance with a mean gradient of 7.5±3.2 mmHg and effective orifice area of 1.9±0.4 cm2 was sustained up to 1 year. CONCLUSIONS: The PORTICO NG Study demonstrates low rates of adverse events and PVL up to 1 year in patients at high or extreme surgical risk, confirming the safety and efficacy of the Navitor THV system.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Desenho de Prótese , Estenose da Valva Aórtica/cirurgia , Acidente Vascular Cerebral/etiologia
11.
JACC Cardiovasc Interv ; 16(6): 681-689, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36990558

RESUMO

BACKGROUND: The self-expanding, intra-annular Navitor (Abbott Structural Heart) valve includes an outer cuff to reduce paravalvular leak (PVL) and large stent cells for future coronary access. OBJECTIVES: The purpose of the PORTICO NG (Evaluation of the Portico NG [Next Generation] Transcatheter Aortic Valve in High and Extreme Risk Patients With Symptomatic Severe Aortic Stenosis) study is to evaluate the safety and effectiveness of the Navitor valve in patients with symptomatic, severe aortic stenosis who are at high or extreme surgical risk. METHODS: PORTICO NG is a prospective, multicenter, global study with follow-up at 30 days, 1 year, and annually through 5 years. The primary endpoints are all-cause mortality and moderate or greater PVL at 30 days. Valve Academic Research Consortium-2 events and valve performance are assessed by an independent clinical events committee and echocardiographic core laboratory. RESULTS: A total of 260 subjects were treated at 26 clinical sites across Europe, Australia, and the United States between September 2019 and August 2022. The mean age was 83.4 ± 5.4 years, 57.3% were female, and the average Society of Thoracic Surgeons score was 3.9% ± 2.1%. At 30 days, the rate of all-cause mortality was 1.9%, and no subjects had moderate or greater PVL. The rate of disabling stroke was 1.9%, life-threatening bleeding was 3.8%, stage 3 acute kidney injury was 0.8%, major vascular complications were 4.2%, and new permanent pacemaker implantation was 19.0%. Hemodynamic performance included a mean gradient of 7.4 ± 3.5 mm Hg and an effective orifice area of 2.00 ± 0.47 cm2. CONCLUSIONS: The Navitor valve is safe and effective for the treatment of subjects with severe aortic stenosis who are at high or greater risk for surgery, which is supported by low rates of adverse events and PVL. (Evaluation of the Portico NG [Next Generation] Transcatheter Aortic Valve in High and Extreme Risk Patients With Symptomatic Severe Aortic Stenosis [PORTICO NG]; NCT04011722).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Estados Unidos , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Desenho de Prótese
12.
Catheter Cardiovasc Interv ; 79(4): 640-3, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21542101

RESUMO

A 58-year-old man underwent an elective coronary bypass graft for severe four-vessel stenosis. Cardiogenic shock developed just after coronary bypass grafting with a left internal mammary artery (LIMA) to left anterior descending (LAD) artery and superficial venous graft to 1st and 2nd obtuse marginal (OM1/OM2) arteries the posterior descending artery (PDA) was too small to graft. Despite significant inotropes and an intra-aortic balloon pump, the patient deteriorated in intensive care unit with cardiogenic shock and ventricular arrhythmia. Urgent coronary angiography revealed a rupture or torn LIMA graft with extravasation of contrast into the left pleural cavity. There was no distal LIMA to LAD flow probably due to graft thrombosis. Revascularisation was performed on the severe ostial native LAD stenosis with a drug eluting stent. The rupture graft was then stented with a polytetrafluoroethylene-covered stent, which stopped the bleeding, and latter, led to total graft thrombosis. The patient improved significantly and supportive inotropes could be weaned down. At 11 month follow-up, the patient had mild left ventricular dysfunction, widely patent ostial LAD stent and thrombosed LIMA graft.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Estenose Coronária/terapia , Stents Farmacológicos , Artéria Torácica Interna/cirurgia , Politetrafluoretileno , Choque Cardiogênico/terapia , Lesões do Sistema Vascular/terapia , Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/cirurgia , Everolimo , Humanos , Masculino , Artéria Torácica Interna/lesões , Pessoa de Meia-Idade , Desenho de Prótese , Ruptura , Índice de Gravidade de Doença , Choque Cardiogênico/etiologia , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia
13.
Catheter Cardiovasc Interv ; 79(5): 794-800, 2012 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21542102

RESUMO

BACKGROUND: Left atrial appendage (LAA) is the main source of left atrial thrombus that causes stroke in patients with non-valvular atrial fibrillation (NVAF). This study reported the initial safety, feasibility, and 1-yr clinical outcomes following AMPLATZER cardiac plug (ACP) implantation in Asia-Pacific region. METHODS: Twenty NVAF patients (16 males, age 68 ± 9 yr) with high risk for developing cardioembolic stroke (CHADS(2) score: 2.3 ± 1.3) and contraindications to warfarin received ACP implants from June 2009 to May 2010. Patients received general anesthesia (n = 9) or controlled propofol sedation (n = 11) and the procedures were guided by fluoroscopy and transesophageal echocardiography (TEE). Clinical follow-up was arranged at 1 month and then every 3 months after implantation, whereas, a TEE was scheduled at 1 month upon completion of dual anti-platelet therapy. RESULTS: The LAA was successfully occluded in 19/20 patients (95%) at two Asian centers. One procedure was abandoned because of catheter-related thrombus formation. Other complications included coronary artery air embolism (n = 1) and TEE-attributed esophageal injury (n = 1). The median procedural and fluoroscopic times were 79 (IQR: 59-100) and 18 (IQR 12-27) minutes, respectively. The mean size of implant was 23.6 ± 3.1 mm. The average hospital stay was 1.8 ± 1.1 days. Follow-up TEE showed all the LAA orifices were sealed without device-related thrombus formation. No stroke or death occurred at a mean follow-up of 12.7 ± 3.1 months. CONCLUSIONS: Our preliminary data suggested LAA closure with ACP is safe, feasible with encouraging 1-yr clinical outcomes. Further large-scaled trials are needed to confirm the efficacy of this device.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/instrumentação , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Cateterismo Cardíaco/métodos , Estudos de Coortes , Ecocardiografia Transesofagiana/métodos , Estudos de Viabilidade , Feminino , Fluoroscopia/métodos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
14.
Nephrology (Carlton) ; 17(5): 445-51, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22390156

RESUMO

AIM: Transcatheter aortic valve implantation (TAVI) poses a significant risk of acute kidney injury (AKI). Little is known of the impact of TAVI and AKI on long-term kidney function and health cost. We explored the predictive factors and prognostic implications of AKI following TAVI. METHODS: Single-centre retrospective analysis of 52 elderly patients undergoing TAVI was conducted. The primary endpoint was renal outcome which included the incidence of AKI and 12-month renal function after TAVI. Secondary endpoints were mortality, the length of hospital stay (LOS) and cost. RESULTS: AKI occurred in 15/52 (28.8%) patients (mean age 84 ± 6) and three patients (6%) required dialysis. Patients with AKI (AKI+) had greater comorbidity (diabetes and cerebrovascular disease) and a trend towards reduced estimated glomerular filtration rate (eGFR) at baseline compared with those without AKI (56.6 vs AKI-: 65.7 mL/min per 1.73 m(2) , P = 0.07). Following TAVI, AKI- patients experienced an immediate improvement in eGFR, which remained significantly higher at all time points compared with AKI+ patients (70.4 vs 46.9 at 6 months and 73.7 vs 53.0 at 12 months, P < 0.001). Cumulative mortality for AKI+versus AKI- group was 26.7% and 2.7% (P = 0.006). LOS doubled (P < 0.001) and average hospitalization cost per patient was 1.5 times higher in the AKI+ group (P < 0.001). Independent predictors of AKI were peri-procedural blood transfusion (OR: 2.4, 95% CI: 2.0-3.1), trans-apical approach (OR: 9.3, 95% CI: 4.3-23.7) and hypertension (OR: 6.4, 95% CI: 2.9-17.3). CONCLUSION: AKI developed in 28.8% of patients after TAVI and was associated with procedural technique and transfusion requirement, and an increased LOS and mortality. However, most patients achieved a significant and sustained improvement in eGFR.


Assuntos
Injúria Renal Aguda/epidemiologia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Injúria Renal Aguda/economia , Injúria Renal Aguda/mortalidade , Injúria Renal Aguda/fisiopatologia , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/economia , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Comorbidade , Feminino , Taxa de Filtração Glomerular , Custos de Cuidados de Saúde , Implante de Prótese de Valva Cardíaca/economia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Hipertensão/epidemiologia , Incidência , Estimativa de Kaplan-Meier , Rim/fisiopatologia , Tempo de Internação , Modelos Logísticos , Masculino , Razão de Chances , Diálise Renal , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Reação Transfusional , Resultado do Tratamento , Austrália Ocidental/epidemiologia
15.
AsiaIntervention ; 8(1): 42-49, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35350794

RESUMO

Aims: Calcified coronary stenoses are a serious impediment to optimal stent expansion and can lead to stent failure and catastrophic adverse outcomes. We hereby present early Australian experience with intravascular lithotripsy for the treatment of calcific lesions in acute and chronic coronary syndromes. Methods and results: This was a single-centre retrospective study of all patients treated with intravascular lithotripsy (IVL) between October 2019 and June 2021. Patient demographics, procedural variables, and treatment safety/efficacy outcomes were evaluated. During this period, there were 40 patients and 41 coronary lesions with IVL-assisted percutaneous coronary intervention (PCI) (70% male; mean age 72.8±9.5 years). Indications for PCI were acute coronary syndromes in 25 patients (62.5%), and stable angina in 15 patients (37.5%). Upfront IVL usage occurred in 5% of cases with the rest being bailout procedures due to suboptimal initial balloon predilatation or stent underexpansion. Angiographic success (<20% residual stenosis) occurred in 37 cases (92.5%), with mean residual stenosis of 8.25%±8.5%. Two patients experienced procedural complications (5%). Conclusions: IVL appears to be a safe and effective modality in modifying coronary calcium to achieve optimal stent expansion in real-world practice. This device obviates the need for more complex lesion preparation strategies such as rotational or orbital atherectomy.

16.
Eur Heart J Case Rep ; 5(12): ytab482, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34993407

RESUMO

BACKGROUND: Despite increasing use of percutaneous coronary intervention and stenting, septic complications such as coronary stent infections are rare. We report a unique case of mitral valve infective endocarditis and associated coronary stent infection which emerged 6 months after index stent insertion. CASE SUMMARY: A 56-year-old previously healthy man underwent percutaneous coronary intervention and stenting of left circumflex (LCx) coronary artery in the setting of non-ST-segment elevation myocardial infarction. Six months later, he represented with inferior ST-segment elevation myocardial infarction and was found to have a coronary pseudoaneurysm of stented segment of LCx. The pseudoaneurysm was treated with insertion of a covered stent, and immediately following that he developed sepsis with methicillin-sensitive Staphylococcus aureus bacteraemia. Comprehensive work-up resulted in the diagnosis of mitral valve endocarditis complicated by coronary stent infection and myocardial abscess formation. He was managed with initial prolonged systemic antibiotic treatment followed by mitral valve replacement. Post-operative course was uneventful with a short duration of oral antibiotics. At 6-year follow-up, the patient was well with the satisfactory echocardiographic result. DISCUSSION: This is a very rare case of mitral valve endocarditis with extensive cardiac involvement including coronary stent infection and surrounding myocardial abscess. Stents can act as an ideal vector for bacterial adherence from which bacteria could spread to the arterial wall and adjacent myocardium. This case suggests a potential complication of delayed endothelialization and risk of infective complication due to bacterial seeding or embolization.

17.
BMJ Case Rep ; 14(11)2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-34815226

RESUMO

A 32-year-old, 11-week pregnant African woman with known rheumatic heart disease presented to the emergency department with worsening shortness of breath on exertion. She had undergone a double bioprosthetic valve replacement and left atrial appendage resection 8 years prior for severe mitral stenosis, moderate mitral regurgitation and moderate aortic regurgitation. A transo-oesophageal echocardiography at this presentation confirmed a morphologically calcified and stenosed mitral bioprosthesis, with moderate stenosis of her aortic bioprosthesis. Her multidisciplinary team, including cardiologists, cardiothoracic surgeons and obstetricians, came to a consensus decision to proceed with a transseptal transcatheter valve implantation within the mitral valve prosthesis (valve-in-valve implantation). Transthoracic echocardiography performed 2 months post procedure showed satisfactory mitral valve gradients and at 30 weeks' gestation, she successfully delivered her fifth child. 2 years later, the valve in valve complex is still functioning well.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Adulto , Cateterismo Cardíaco , Criança , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Gravidez , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 13(21): 2467-2478, 2020 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-33153563

RESUMO

OBJECTIVES: The aim of this study was to characterize the safety profile of an intra-annular self-expanding valve with a next-generation low-profile delivery system (DS). BACKGROUND: Key design modifications to the FlexNav DS include the addition of a hydrophilic-coated, integrated sheath and stability layer to facilitate gradual, controlled deployment in vessels with diameter ≥5 mm. METHODS: Patients were pooled from 2 concurrent prospective, multicenter, single-arm studies (FlexNav DS arm of PORTICO IDE [Portico Re-Sheathable Transcatheter Aortic Valve System U.S. IDE Trial] [n = 134] and the FlexNav EU CE Mark Study [n = 46]) for the analysis. The primary endpoint was Valve Academic Research Consortium-2-defined major vascular complications at 30 days. Clinical outcomes and valve performance were assessed through 30 days by an independent clinical events committee and an echocardiography core laboratory, respectively. RESULTS: One hundred forty high-risk and 40 extreme-risk subjects enrolled between October 15, 2018, and December 10, 2019, from 28 sites in the United States, Australia, and Europe who underwent attempted transfemoral Portico valve implantation were included. The mean age was 85.1 ± 5.6 years, 60% were women, the mean Society of Thoracic Surgeons score was 5.3%, and 96.1% presented with ≥1 frailty factor. Technical device success was 96.7%. At 30 days, the rate of major vascular complications was 5.0%, with 4.4% of complications adjudicated as access site-related (3.3% transcatheter aortic valve replacement DS access site-related). Death (0.6%) and disabling stroke (1.1%) were rare. The rate of new permanent pacemaker implantation was 15.4%. Echocardiography revealed a mean gradient of 7.1 ± 3.2 mm Hg, mean valve area of 1.77 ± 0.41 cm2, and a 4.1% rate of moderate paravalvular leak at 30 days. CONCLUSIONS: Portico valve implantation with the FlexNav DS was associated with an excellent safety profile at 30 days.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Austrália , Europa (Continente) , Feminino , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
19.
Am Heart J ; 157(1): 60.e1-9, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19081397

RESUMO

BACKGROUND: There is uncertainty about the benefit of a higher loading dose (LD) of clopidogrel in patients with non-ST elevation acute coronary syndrome (NSTEACS) undergoing early percutaneous coronary intervention (PCI). METHODS: We compared the effects of a 600- versus a 300-mg LD of clopidogrel on inhibition of platelet aggregation, myonecrosis, and clinical outcomes in patients with NSTEACS undergoing an early invasive management strategy. Patients with NSTEACS (n = 256, mean age 63 years, 81.6% elevated troponin) without thienopyridine for at least 7 days were randomized to receive 600- or 300-mg LD of clopidogrel. Percutaneous coronary intervention was performed in 140 patients, with glycoprotein IIb/IIIa inhibitor use in 68.6%. Adenosine diphosphate (ADP)-induced platelet aggregation was measured by optical platelet aggregometry immediately before coronary angiography. RESULTS: Post-PCI myonecrosis was defined as a next-day troponin I greater than 5 times the upper limit of reference range and greater than baseline levels. Clopidogrel 600-mg LD compared with 300-mg LD was associated with significantly reduced ADP-induced platelet aggregation (49.7% vs 55.7% with ADP 20 micromol/L) but did not reduce post-PCI myonecrosis or adverse clinical outcomes to 6 months. There was no association between preprocedural platelet aggregation and outcome. CONCLUSIONS: These data confirm a modest incremental antiplatelet effect of a 600-mg clopidogrel LD compared with 300-mg LD but provide no support for a clinical benefit in patients with NSTEACS managed with an early invasive strategy including a high rate (69%) of glycoprotein IIb/IIIa inhibitor use during PCI.


Assuntos
Síndrome Coronariana Aguda/terapia , Angioplastia Coronária com Balão , Inibidores da Agregação Plaquetária/administração & dosagem , Ticlopidina/análogos & derivados , Síndrome Coronariana Aguda/sangue , Aspirina/uso terapêutico , Plaquetas/efeitos dos fármacos , Plaquetas/fisiologia , Clopidogrel , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Necrose , Ticlopidina/administração & dosagem , Troponina/sangue
20.
Catheter Cardiovasc Interv ; 74(6): 957-64, 2009 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-19642193

RESUMO

BACKGROUND: During hemodynamic assessment prior to antegrade balloon aortic valvuloplasty (BAV), unanticipated transmitral valve pressure gradients (MVG) were noted frequently. AIM: To determine the prevalence and significance of a significant MVG in patients with aortic stenosis and no previously diagnosed mitral valve stenosis. METHOD: Retrospective chart review of patients with severe aortic stenosis who underwent antegrade BAV. During antegrade BAV, direct transseptal left atrial (LA) and left ventricular (LV) pressure measurements were obtained allowing for accurate assessment of MVG. Significant MVG is defined as a LA-LV gradient of > or =5 mm Hg. RESULTS: Eighty-two BAV patients were reviewed (mean age 84 +/- 8.9 years, mean additive Euroscore 10.5 +/- 2.2). The mean MVG was 5.0 +/- 3.5 mm Hg (range 0-14 mm Hg). A significant MVG was seen in 54.9% and, compared with no significant MVG, was associated at with significantly higher LA mean pressure (26.0 +/- 6.0 mm Hg vs. 16.8 +/- 6.6 mm Hg, P < 0.001), higher pulmonary arterial systolic pressure (59.3 +/- 14.7 mm Hg vs. 43.1 +/- 16.5 mm Hg, P < 0.001), and higher pulmonary mean systolic pressure (37.7 +/- 10.4 mm Hg vs. 28.0 +/- 11.4 mm Hg, P < 0.001). Statistically significant correlations were seen between MVG and LA mean pressure (r = 0.65, P < 0.001), pulmonary arterial systolic (r = 0.49, P < 0.001) and pulmonary arterial mean pressures (r = 0.41, P < 0.001). There was no association with cardiovascular risk factors, with presence or severity of mitral annular calcification (visually assessed on cine-fluoroscopy) or with the presence of mitral regurgitation. CONCLUSIONS: A significant MVG is commonly seen in patients with severe calcific aortic stenosis and is associated with higher pulmonary arterial and left atrial pressures.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Calcinose/fisiopatologia , Hemodinâmica , Valva Mitral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Função do Átrio Esquerdo , Pressão Sanguínea , Calcinose/diagnóstico por imagem , Calcinose/terapia , Cateterismo , Cinerradiografia , Diástole , Feminino , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Função Ventricular Esquerda , Pressão Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA