Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Rev Esp Enferm Dig ; 115(11): 655-656, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36779472

RESUMO

Endoscopic retrograde cholangiopancreatography has been widely used in the diagnosis and treatment of biliary and pancreatic diseases. Post-ERCP complications mainly include pancreatitis, infection, bleeding, and perforation. However, post-ERCP left hepatic subcapsular hematoma is a rare and potentially life-threatening complication. A total of five cases have been reported in the literature, including one death due to bleeding from a ruptured hematoma. We report a case of post-ERCP hepatic subcapsular hematoma of the left lobe of the liver in a 29-year-old woman who was diagnosed with a left hepatic subcapsular hematoma 56 hours after ERCP and whose symptoms did not improve after conservative treatment. A CT-guided percutaneous puncture was then performed, and the drainage fluid was a dark red fluid mixed with blood and bile. On days 1, 2, 3, 4, and 5, respectively, following drainage, the drainage flow was 400 ml, 40 ml, 70 ml, 50 ml, and 30 ml.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Hepatopatias , Feminino , Humanos , Adulto , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Hematoma/cirurgia , Drenagem , Hepatopatias/diagnóstico por imagem , Hepatopatias/etiologia , Hepatopatias/cirurgia
2.
Opt Express ; 29(14): 21113-21128, 2021 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-34265905

RESUMO

We investigate a novel two-channel grating encoder that can perform simultaneous measurements of six-degree-of-freedom (DOF) motions of two adjacent sub-components of synthetic-aperture optics such as pulse-compression gratings(PCGs) and telescope-primary mirrors. The grating encoder consists of a reading head and two separate gratings, which are attached to the back of the sub-components, respectively. The reading head is constructed such that there two identical optical probes can share the same optical components. The two probes are guided to hit each of the two gratings and can detect six-DOF motions simultaneously and independently. For each probe, the incident beam propagates through both a three-axes grating interferometry module and a three-axes diffraction integrated autocollimator-module, which detects translational and rotational movement, respectively. By combining the two modules it is possible to perform six-DOF measurement for a single point. The common-path configuration of the two probes enable identical responses to environmental variation, which ensures high accuracy.

3.
Appl Opt ; 60(30): 9358-9364, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34807072

RESUMO

The design, fabrication, and demonstration of a planar two-dimensional-crossed reflective diffractive grating are proposed to construct a novel optical configuration, to the best of our knowledge, potentially applied for atom cooling and trapping in a magneto-optical trap. Based on the proposed single-beam single-exposure scheme by means of an orthogonal two-axis Lloyd's mirrors interferometer, we rapidly patterned a ∼1µm period grating capable of providing a uniform intensity of the diffracted beams. The key structural parameters of the grating including the array square hole's width and depth were determined, aiming at providing a high energy of the diffracted beams to perform the atom cooling and trapping. To guarantee the diffracted beams to be overlapped possibly, we adopted a polarized beam splitter to guide the optical path of the incident and zero-order diffracted beams. Therefore, one zero-order diffracted beam with a retroreflected mode and four first-order diffracted beams with appropriate optical path constructed a three-dimensional optical configuration of three orthogonal pairs of counterpropagating beams. Finally, three pairs of the counterpropagating cooling laser beams with 9 mm diameter and >10% diffraction efficiencies were achieved, and the circular polarization chirality, purity, and compensation of the desired diffracted beams are further evaluated, which preliminarily validated a high applicability for the magneto-optical trap system.

4.
Sensors (Basel) ; 20(8)2020 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-32316231

RESUMO

Among various nanometer-level displacement measurement methods, grating interferometry-based linear encoders are widely used due to their high robustness, relatively low cost, and compactness. One trend of grating encoders is multi-axis measurement capability for simultaneous precision positioning and small order error motion measurement. However, due to both lack of suitable hardware data processing platform and of a real-time displacement calculation system, meeting the requirements of real-time data processing while maintaining the nanometer order resolutions on all these axes is a challenge. To solve above-mentioned problem, in this paper we introduce a design and experimental validation of a field programmable gate array (FPGA)-cored real-time data processing platform for grating encoders. This platform includes the following functions. First, a front-end photodetector and I/V conversion analog circuit are used to realize basic analog signal filtering, while an eight-channel parallel, 16-bit precision, 200 kSPS maximum acquisition rate Analog-to-digital (ADC) is used to obtain digital signals that are easy to process. Then, an FPGA-based digital signal processing platform is implemented, which can calculate the displacement values corresponding to the phase subdivision signals in parallel and in real time at high speed. Finally, the displacement result is transferred by USB2.0 to the PC in real time through an Universal Asynchronous Receiver/Transmitter (UART) serial port to form a complete real-time displacement calculation system. The experimental results show that the system achieves real-time data processing and displacement result display while meeting the high accuracy of traditional offline data solution methods, which demonstrates the industrial potential and practicality of our absolute two-dimensional grating scale displacement measurement system.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA