Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
J Neural Eng ; 20(3)2023 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-37144338

RESUMO

Objective. Therapeutic intervention in neurological disorders still relies heavily on pharmacological solutions, while the treatment of patients with drug resistance remains an unresolved issue. This is particularly true for patients with epilepsy, 30% of whom are refractory to medications. Implantable devices for chronic recording and electrical modulation of brain activity have proved a viable alternative in such cases. To operate, the device should detect the relevant electrographic biomarkers from local field potentials (LFPs) and determine the right time for stimulation. To enable timely interventions, the ideal device should attain biomarker detection with low latency while operating under low power consumption to prolong battery life.Approach. Here we introduce a fully-analog neuromorphic device implemented in CMOS technology for analyzing LFP signals in anin vitromodel of acute ictogenesis. Neuromorphic networks have progressively gained a reputation as low-latency low-power computing systems, which makes them a promising candidate as processing core of next-generation implantable neural interfaces.Main results. The developed system can detect ictal and interictal events with ms-latency and with high precision, consuming on average 3.50 nW during the task.Significance. The work presented in this paper paves the way to a new generation of brain implantable devices for personalized closed-loop stimulation for epilepsy treatment.


Assuntos
Estimulação Encefálica Profunda , Epilepsia , Humanos , Silício , Convulsões/diagnóstico , Epilepsia/diagnóstico , Encéfalo , Estimulação Encefálica Profunda/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-38083592

RESUMO

Within this paper, we demonstrate the feasibility of the FPGA implementation as well as the 180nm CMOS circuit design of a particular biologically plausible supervised learning algorithm (ReSuMe). Based on the Spike-Timing-Dependent Plasticity (STDP) learning phenomenon, this design proposes a fully configurable implementation of STDP learning window function to adjust the learning process for different applications, optimizing results for each use case. The CMOS implementation in 180nm technology node supplied with 1.8V shows a core area of 0.78mm2 and verifies the suitability of an on-chip ReSuMe learning algorithm implementation and its capability of integration with a multitude of external and already designed structures of Spiking Neural Networks (SNNs).


Assuntos
Plasticidade Neuronal , Neurônios , Modelos Neurológicos , Redes Neurais de Computação , Algoritmos
3.
IEEE Trans Biomed Circuits Syst ; 17(5): 1097-1110, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37436854

RESUMO

This article presents a chip designed for wireless intra-cardiac monitoring systems. The design consists of a three-channel analog front-end, a pulse-width modulator featuring output-frequency offset and temperature calibration, and inductive data telemetry. By employing a resistance boosting technique in the instrumentation amplifier feedback, the pseudo-resistor exhibits lower non-linearity, leading to a total harmonic distortion of below 0.1%. Furthermore, the boosting technique enhances the feedback resistance, leading to a reduction in the size of the feedback capacitor and, consequently, the overall size. To make the modulator's output frequency resilient to temperature and process changes, coarse and fine-tuning algorithms are used. The front-end channel is capable of extracting the intra-cardiac signal with an effective number of bits of 8.9, while exhibiting an input-referred noise of less than 2.7 µVrms, and consuming 200 nW per channel. The front-end output is encoded by an ASK-PWM modulator, which drives an on-chip transmitter at 13.56 MHz. The proposed System-on-Chip (SoC) is fabricated in a 0.18 µm standard CMOS technology and consumes 4.5 µW while occupying 1.125 mm2.


Assuntos
Eletrocardiografia , Telemetria , Monitorização Fisiológica , Amplificadores Eletrônicos , Algoritmos , Tecnologia sem Fio , Processamento de Sinais Assistido por Computador , Desenho de Equipamento
4.
IEEE Trans Biomed Circuits Syst ; 12(1): 211-221, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29377809

RESUMO

This paper presents an implantable bio-impedance measurement system for cardiac pacemakers. The fully integrated system features a low power analog front-end and pulse width modulated output. The bio-impedance readout benefits from voltage to time conversion to achieve a very low power consumption for wirelessly transmitting the data outside the body. The proposed IC is fabricated in a 0.18 µm CMOS process and is capable of measuring the bio-impedance at 2 kHz over a wide dynamic range from to with accuracy and maximum current injection while consuming just from a 1 V supply.


Assuntos
Impedância Elétrica , Marca-Passo Artificial , Humanos
5.
IEEE Trans Biomed Circuits Syst ; 12(3): 589-600, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29877822

RESUMO

A low-power mixed-signal IC for implantable pacemakers is presented. The proposed system features three independent intracardiac signal readout channels with pulse-width-modulated outputs. Also, the proposed system is capable of measuring the amplitude and phase of the bioimpedance with pulse-width-modulated outputs for use in rate adaptive pacemakers. Moreover, a stimulation system is embedded, offering 16 different amplitudes from 1 to 7.8 V. A backscattering transmitter transfers the output signals outside the body with very little power consumption. The proposed low-power mixed-signal IC is fabricated in a 0.18-µm HV CMOS process and occupies 2.38 mm2. The biopotential channels extract the heart signals with 9.2 effective number of bits and the bioimpedance channels measure the amplitude and phase of the heart impedance with 1.35 Ωrms accuracy. The complete IC consumes only 4.2 µA from a 1-V power supply.


Assuntos
Marca-Passo Artificial , Telemetria , Tecnologia sem Fio/instrumentação , Telemetria/instrumentação , Telemetria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA